Learn how to test your refrigeration unit without removing it from the machine. Check to see if there is a probelm with your deck or if the problem is somewhere else in the machine by using an external power source and gauging the results.

Пікірлер: 103
@ericschwa1479
@ericschwa1479 5 жыл бұрын
Great instruction! Enthusiastic and knowledgeable.
@pinqueenmartin9582
@pinqueenmartin9582 3 жыл бұрын
Nice! Replaced capacitor, charged the system, and now it looks like I have a good unit! Excellent easy test!
@AdamZeroGalusha
@AdamZeroGalusha Ай бұрын
How did you determine how much charge it took
@jlee1480
@jlee1480 2 жыл бұрын
I am so happy i found your channel! So much great information here! Thanks for this video!!
@ToddDemers-u4s
@ToddDemers-u4s Жыл бұрын
Thank you for your video. It was very good. I have a used 501e pop machine and the evaporator fans run all the time. My machine is located indoors and I can hear when the condenser kicks on and off. Is there a way to quiet the evaporator fans when is is not cooling down the cold box?
@albertarguelles3262
@albertarguelles3262 4 жыл бұрын
Hi Great Video Do you know how to Disconnect the Window Heater on these combo vend machines? Thanks
@trogers8180
@trogers8180 8 ай бұрын
I’m doing this test currently. Do you have a video on how to recharge the system?
@Tay-vk3et
@Tay-vk3et Жыл бұрын
Did this. compressor came on when plugged in however there was no ice around evaporator and it was warm to touch. potential compressor replacement?
@Vendingworks
@Vendingworks Жыл бұрын
Sounds more like there is a leak and no refrigerant left in the system
@Tay-vk3et
@Tay-vk3et Жыл бұрын
@@Vendingworks thank you!
@XxPyschoFarmerxX
@XxPyschoFarmerxX Жыл бұрын
Hi Amy, I recently acquired a Dixie Narco 501e 9select, doing the same testing as you did in this video. Mine is cold but did not frost in those 15mins, I’m going on 20 mins now just starting to frost, also I have a digital temp control is this preset to the cold temp It keeps reading 65 degrees pls help
@kyleyates5774
@kyleyates5774 4 жыл бұрын
hi quick question-what if you get the same results (frost on the accumulator, etc) when the machine is fully plugged in (evaporator fans running)?
@Vendingworks
@Vendingworks 4 жыл бұрын
Sorry for the delayed response! The problem you are describing would be caused by a bad thermostat, because its not shutting the deck off at the proper time. The good news is, that's generally the cheapest problem to resolve.
@MatTodd-hp2sm
@MatTodd-hp2sm 6 ай бұрын
Hello - what model Dixie is this? I have the exact same one but the ID plate is missing and I don’t know how to identify it! Thank you
@Vendingworks
@Vendingworks 6 ай бұрын
I think it's a 368
@MarioPerez-df9gx
@MarioPerez-df9gx Жыл бұрын
Hello, I have a dixie narco 501E, which the compressor tries to turn on and only works for a few seconds and then the compressor and the condenser fan stop. I would like to know what could be the cause?
@carmillamartin8035
@carmillamartin8035 2 жыл бұрын
Thanks for the video . I did the test exactly how you said . Cooling deck is good . What is the next step in diagnosing why the cooling deck is not kicking on !
@Vendingworks
@Vendingworks 2 жыл бұрын
Your machine most likely just has a bad thermostat
@carmillamartin8035
@carmillamartin8035 2 жыл бұрын
@@Vendingworks Thanks for your quick response . I am very appreciative .what is the best place to get one from fast and reasonablely priced ?
@Vendingworks
@Vendingworks 2 жыл бұрын
@@carmillamartin8035 link: vendingworks.com/collections/refrigeration-parts-1/products/brand-new-dixie-narco-soda-pop-machine-thermostat-fits-coke-pepsi-machines
@carmillamartin8035
@carmillamartin8035 2 жыл бұрын
@@Vendingworks 👌👍Thanks
@michaelmelendez9576
@michaelmelendez9576 2 жыл бұрын
I have a Dixie narco exactly like this and it does not stop cooling every few month it does it. What I do is I unplug the thermostat and plug it back in and it starts to shut off and on like normal. Could it be the thermostat going bad? It has done it 3 times now.
@heribertopinon5317
@heribertopinon5317 2 жыл бұрын
My royal vendors blows the breaker when the compressor kicks on . Would that need a compressor change ? And a fan ?
@windturbineclimber5412
@windturbineclimber5412 Жыл бұрын
This is a good video. Thank you. But I have a different problem. All of the drinks in my machine are freezing up. What could be the problem? How can I fix this? Also, I see that you have a lot of units in the background, do you sell parts? Where can I find a schematic for this machine?
@Vendingworks
@Vendingworks Жыл бұрын
If the drinks are freezing then you just need to replace the thermostat. Schematic for the machine you can usually find on the inner door of the machine. We sell coin mechs, bill validators, and refrigeration decks for vending machines.
@windturbineclimber5412
@windturbineclimber5412 Жыл бұрын
@@Vendingworks Thank you that helps alot. The schematics are missing on this machine. I have looked everywhere. Do you have a website or somewhere I can order parts from yall online?
@Vendingworks
@Vendingworks Жыл бұрын
@@windturbineclimber5412 Vendingworks.net is our website
@pyrocat1150
@pyrocat1150 Жыл бұрын
I have a Royal 552-8, the condenser is frosted over heavily. I've unplugged machine for a few days and turned it back on. The top 2/3 of condenser has thick layer of frost. Door seals are good. We have duplicate machine that has clear condenser so we are wondering what's wrong. It does cool just fine
@matthewpreston8374
@matthewpreston8374 Жыл бұрын
Bad evaporater fan motor? check amp load
@garymeyer5335
@garymeyer5335 3 жыл бұрын
my evaporator is cool but not cold. when i plug it into an extention cord it gets good frost so the unit is good. is my problem a bad thermostat?
@Vendingworks
@Vendingworks 3 жыл бұрын
If the entire evaporator is frosted up then yes the unit is good and you probably have a bad thermostat. If the evaporator only frosts up partially then it is low on refrigerant.
@garymeyer5335
@garymeyer5335 3 жыл бұрын
@@Vendingworks thank you so much
@garymeyer5335
@garymeyer5335 3 жыл бұрын
@@Vendingworks would it be ok to keep the soda machine plugged in and the cooling deck plugged into an extension cord so i can make money while i wait for the parts? the only problem i can see is it might get too cold....
@davidfarrar3666
@davidfarrar3666 2 жыл бұрын
Help! I have a machine identical to the one in the video except there is no thermostat either where yours is or by the evaporator...I don't know how the temperature is controlled. Anyway, when I perform this test the deck functions correctly. When I plug the machine into the wall and close the door, the compressor starts in a few minutes but then after a few more minutes it kicks off, gets hot, no cooling. I thought it might be the refrigerant relay and ordered one but now I'm not sure because like I said, the compressor does start - just doesn't stay running.
@Vendingworks
@Vendingworks 2 жыл бұрын
It would help to know what model machine you have. There is either a thermostat or a temperature sensor depending on what model you have. It sounds like you may have a polarity issue, double check your wiring. If the plug on your machine (that plugs into the wall) has ever been changed, check to make sure polarity is correct. Black (hot) wire to small blade, white (neutral) wire to fatter blade, and green to ground
@CartellaGlassandGlazing
@CartellaGlassandGlazing 4 жыл бұрын
Hi I have carried out the test you have advised i am getting no ice what so ever, can you advise is it worth trying to replace the relay/thermostat maybe install the superstar 3 in 1? Or beat to just replace the full unit?
@Vendingworks
@Vendingworks 4 жыл бұрын
Hello! This test bypasses the thermostat, so if you do replace it, you will still have another issue. If you send me a video of the unit running, I can help verify if your unit would be a candidate for a 3 in 1, or if it needs replacing altogether. Email to Vendingworks@yahoo.com
@johnhorchler667
@johnhorchler667 3 ай бұрын
I just found your channel and off to bed this video 📹 is from 4 years ago do you still make new video clips?
@wisconsinbush2940
@wisconsinbush2940 18 күн бұрын
Can’t you measure your superheat and sub cooling to figure out if it’s working properly?
@Vendingworks
@Vendingworks 18 күн бұрын
Sure can, just add a couple of valves to the sealed system and hook up your gauges. Because everybody knows how to do that and has a set of gauges laying around
@timsmith4194
@timsmith4194 2 ай бұрын
Mine continues to run and the top coils are freezing like a block of ice. Is this a bad thermostat?
@Vendingworks
@Vendingworks 2 ай бұрын
It means there is a leak in the system and it is low on refrigerant
@deronaldbaggett3828
@deronaldbaggett3828 2 ай бұрын
Excellent!
@howtobrandon1576
@howtobrandon1576 2 жыл бұрын
Relay is getting 24 volts so it’s getting power to the switch any help ?
@winners12345
@winners12345 3 жыл бұрын
Quick question. My unit gets cold but it stays running 24/7 and after about 12 to 15 hrs it is still running but is now warm not at all cold. I just completed your check in your video and my compressor works just as yours did. Any possible troubleshooting suggestions?
@Vendingworks
@Vendingworks 3 жыл бұрын
After running for 12 hours is the evaporator solid ice, or is it (the evaporator) not cold at all? pictures would help me diagnose
@egmac100
@egmac100 Жыл бұрын
Bad fan
@edochamp
@edochamp Жыл бұрын
Thanks for the info
@iramillender1974
@iramillender1974 3 жыл бұрын
I have older model coke machine with cooling problems
@rioraton
@rioraton 2 жыл бұрын
how do you replace condenser fan motor on this unit
@davidingalls796
@davidingalls796 3 жыл бұрын
I have a Vendo 90 coke machine. (1960's) Can I use this same process to test the refrigeration system? Thanks.
@Vendingworks
@Vendingworks 3 жыл бұрын
Yes you can use the same process for any soda machine.
@davidingalls796
@davidingalls796 3 жыл бұрын
@@Vendingworks Great thanks! How do I determine what type of freon to use in order to recharge it? I've done a little research and it sounds like r12?
@Vendingworks
@Vendingworks 3 жыл бұрын
@@davidingalls796 R-12 is no longer available but there are plenty of R-12 replacements out there. We are currently using R-417c (Hot Shot 2)
@davidingalls796
@davidingalls796 3 жыл бұрын
@@Vendingworks Thank you. I just want to make sure I use the correct type of freon to recharge a Vendo 90 Coke machine. I may end up needing to replace the cooling system.
@iramillender1974
@iramillender1974 3 жыл бұрын
Would love advice on how to fix
@Vendingworks
@Vendingworks 3 жыл бұрын
I would need more information. If it is an electrical issue (compressor not running) I would try a 3 in 1. if the compressor (and fan) runs but system doesn't get cold then most likely there is a leak that would need to be repaired
@curtisramsey2219
@curtisramsey2219 Жыл бұрын
How much to replace the coolant mine isn't getting cold
@Vendingworks
@Vendingworks Жыл бұрын
If it is low on refrigerant then there is a leak in the system that must be fixed first
@Johnny-ip4mk
@Johnny-ip4mk 3 жыл бұрын
Mine is encased in frost/ice. I tried defrosting it and it eventually just gets encased again. What am I looking at here? Thanks!
@jonfloyd1160
@jonfloyd1160 3 жыл бұрын
Probably a bad thermostat
@hg2.
@hg2. 3 жыл бұрын
Well done - thanks.
@instafixies8208
@instafixies8208 11 ай бұрын
Hi, Good work with the video. Just have a quick question. We have vending machines and some of them have ice formation on evaporator. We have tried every possible thing but no solution. Last we’ve asked by OEM to replace evaporator fans with higher RPM ones. Will that help? Btw: it’s hot food vending machine with target temp @ 3-4 degrees. Hope I didn’t bother. 😊
@Vendingworks
@Vendingworks 11 ай бұрын
If ice is forming on only part of the evaporator then that usually means there is a leak and it's low on charge. If you could send some pictures I'm sure I could diagnose it for you vendingworks@yahoo.com
@paulbunyun4479
@paulbunyun4479 2 жыл бұрын
instead of unplugging the refrigeration deck and getting a extension cord, just unplug one of the electrical connectors to the evaporator fan motor, you will get the same results, Ive been working on the stuff for 37yrs
@bcsbbq7829
@bcsbbq7829 Жыл бұрын
Are you located in Texas by chance?
@birdynest8232
@birdynest8232 3 жыл бұрын
What is the best # level in the vending machine cooling
@charlesedmonds7054
@charlesedmonds7054 2 жыл бұрын
What is happening if the evaporator is freezing up
@jamestolbert6528
@jamestolbert6528 3 жыл бұрын
my unit is cooling but the fan is very noisy how do i replace the fan?
@marcustaylor2401
@marcustaylor2401 3 жыл бұрын
My machine keeps building ice on the evaporator,and then the sodas get warm,can you help?
@jonfloyd1160
@jonfloyd1160 3 жыл бұрын
The entire evaporator ices up, or just part of it?
@lnajsh
@lnajsh 3 жыл бұрын
The accumulator in my machine has ice in it but the sodas in the machine itself are not super cold. Why is that?
@Vendingworks
@Vendingworks 3 жыл бұрын
Probably bad evaporator fan, maybe bad thermostat
@jetstar1961
@jetstar1961 4 жыл бұрын
hello, my compressor, like buzzis for a sec. and stops. p.s.i. is okay, any id.
@dennissmith5865
@dennissmith5865 Жыл бұрын
Purple valve located where's the valve located
@ksomsouthi
@ksomsouthi 4 жыл бұрын
My machine builds ice & will not stay cold. Help!
@Vendingworks
@Vendingworks 4 жыл бұрын
Definitely sounds like a bad thermostat.
@FuquarProductions
@FuquarProductions Жыл бұрын
My evaporator is completely turning into a block of ice.... Low refrigerant possibly?
@Vendingworks
@Vendingworks Жыл бұрын
If it is completly covered with ice then the refrigerant charge is fine. The problem is going to be a bad thermostat or bad evaporator fan. If the evaporator is only partially covered with ice then there is a leak in the system and it is low on refrigerant
@FuquarProductions
@FuquarProductions Жыл бұрын
@Vendingworksnet as it turns out I moved the thermostat all the way up and down a few times then back to set temp and the problem cleared up.
@JorgeVictoria
@JorgeVictoria 4 жыл бұрын
Hermosa
@gregmusselman7466
@gregmusselman7466 5 жыл бұрын
Who is she?
@rogergordon63
@rogergordon63 4 ай бұрын
lovely figure
@carissafollis
@carissafollis 4 жыл бұрын
My compresser on my machine keeps turning on but then after about a minute will turn off, would you know what the problem is?
@Vendingworks
@Vendingworks 4 жыл бұрын
Well if it's a Royal or AMS machine it could be a bad refrigeration relay. If it's any other machine, it could be a bad compressor or a bad electrical component. I would start by installing a 3 in 1.
@kilogrammountain3453
@kilogrammountain3453 3 жыл бұрын
It is low of freon
@11dayzjourney
@11dayzjourney 2 жыл бұрын
My coke vending machine is freezing my drinks? What could it be?
@jay863betta
@jay863betta Жыл бұрын
She’s cute
@Analytics_Com
@Analytics_Com 2 жыл бұрын
I will try to transform a vending machine like this into a refrigerator.
@rigobertodimas8014
@rigobertodimas8014 2 жыл бұрын
My dickcy narco 501 has ice across the top of the coils not all the coils just the top half and tubs on the side
@danjustus1
@danjustus1 2 жыл бұрын
I was a bit distracted while trying to learn.
@susandaley3713
@susandaley3713 5 ай бұрын
Do buy pop machines
@howtobrandon1576
@howtobrandon1576 2 жыл бұрын
I have a ams 39 vcb my ac just blows hot air
@Vendingworks
@Vendingworks 2 жыл бұрын
You probably have a bad refrgeration relay, very common in AMS machines
@howtobrandon1576
@howtobrandon1576 2 жыл бұрын
I’ve tested it and it has 24 volts coming out
@howtobrandon1576
@howtobrandon1576 2 жыл бұрын
Is it still possible for it to be not working even though it gets power
@Vendingworks
@Vendingworks 2 жыл бұрын
@@howtobrandon1576 you need to test the 110 volt side of the relay
@Vendingworks
@Vendingworks 2 жыл бұрын
@@howtobrandon1576 Unplug the compressor from the machine and plug it directly into a wall socket. this bypasses the relay, if it works then your relay is bad
@fredfrappe
@fredfrappe 2 жыл бұрын
4/10
@pimpstar2
@pimpstar2 Жыл бұрын
good info.....
How to troubleshooting drink vending machine's cooling system while on location
13:04
How to fix a Vending Machine that won't Cool
10:01
Do It Yourself
Рет қаралды 76 М.
龟兔赛跑:好可爱的小乌龟#short #angel #clown
01:00
Super Beauty team
Рет қаралды 68 МЛН
Osman Kalyoncu Sonu Üzücü Saddest Videos Dream Engine 269 #shorts
00:26
兔子姐姐最终逃走了吗?#小丑#兔子警官#家庭
00:58
小蚂蚁和小宇宙
Рет қаралды 9 МЛН
DIY Vapor Compression Refrigeration System
28:06
Hyperspace Pirate
Рет қаралды 1,2 МЛН
How to Change A Dixie Narco Soda Machine Vend Motor
16:29
Happy Vending
Рет қаралды 6 М.
Which Vending Machine Is The Best To Buy
10:14
Amy Allen
Рет қаралды 57 М.
Customer Fired Other Company! Can I Figure This No Cooling Out?
18:25
Jeff’s HVAC Adventures
Рет қаралды 529 М.
What's Inside a Dehumidifier?
9:02
Zach Fields
Рет қаралды 176 М.
Switching from Cans to Bottles in a Soda Machine
25:17
Happy Vending
Рет қаралды 32 М.
HVAC 128 Recovery most used but slowest
10:43
Love2HVAC with Ty Branaman
Рет қаралды 85 М.
What to look for when buying used vending machines ✅
13:45
Let's Talk About It
Рет қаралды 43 М.
Replacing a Bad Cooling Deck in a Soda Machine
26:50
Happy Vending
Рет қаралды 19 М.
Refrigeration Unit (Full Service)
16:48
Vendnet USA
Рет қаралды 100 М.
龟兔赛跑:好可爱的小乌龟#short #angel #clown
01:00
Super Beauty team
Рет қаралды 68 МЛН