Dude, your videos are saving my ass, I'm new to the business and your videos have helped me greatly. Thank you for what you do.
@GlitchedAngel21 Жыл бұрын
Thank you as a new vending machine owner who’s machine stopped cooling I greatly appreciate this because I don’t wanna pay someone a but load to come out and take a look and now thanks to this I have the confidence to check for myself!
@koutakleinschmidt343 Жыл бұрын
Wow, must be a very good refrigeration mechanic you got there!
@VendingMachineSupport Жыл бұрын
I like to think I do.
@SandipMehta-q6e11 ай бұрын
Great video and very helpful information. I did the tests and condenser and evaporator fan works fine along with thermostat. I noticed next to evaporator coil - notice a chunk of ice build up. After thawing it, ran the 15 mins test as you recommended, I see some frost. What would cause the ice build up next to Evaporator coils (looks like kidney bean)?
@albertespinoza13902 ай бұрын
I have a GO-380 combo vending machine. Compressor and condenser blower run, the thermostat stat turns the compressor off when turned off but it take a long while to turn it back on. What could be the problem? Drinks are warm by the way
@wallysensei Жыл бұрын
Hello, recently my 501e went warm and the machine is tripping the outlet whenever the compressor is plugged in within the machine.. Is it time for a new compressor? Thanks for all the info you provide
@flawlesssnipes6308 ай бұрын
So it looks like it’s my compressor fan do you have a video of a replacement ?
@beatricecarrizales22968 ай бұрын
I have a vendo 721 and my evap is completely frozen when i open machine cond fan isnt on but wondering if i have a eco system machine how would i be able to tell?
@h.b45179 ай бұрын
I have a KM series machine. It's only a year old and its getting louder. From your video I believe it's the evaporator fan. The one that is always on, what should I look for if it is getting louder? I removed the back and made sure it's not sure it's not sucking up dust. I just don't know what to do now.
@josephburns1037 Жыл бұрын
Great video. Thanks Alex.
@aedinquinn8687 Жыл бұрын
Dud refrigeration tech replace compressor? What was diagnosis? Aedin
@d.o.cthebarber90965 ай бұрын
Hello there and thank you for your very very helpful videos. So my question is checked the condenser fan and it was good then the evaporator fan and it did not turn on so did the evaporator coil test and it froze up like in the video does that mean it needs to be charged too or is that caused due to the fan not working?
@FunnyRandomz4U5 ай бұрын
It either means the fan has gone bad or the relay has gone bad. You can check to see if your evaporator fan is running in the back. That will be a pretty clear sign it is time to replace your evaporator fan.
@Era_JustBelieve Жыл бұрын
My location lost power recently and reset my whole Royal 650 drink machine. Prices went to .50 cents and now it’s cooling warm air. What’s the exact settings for this machine to get it cold ?
@jasmingresham210811 ай бұрын
This is such an informative video. My machine is triggering the breaker making it go out at its location. Do you know if that is because of the fan or the condenser?
@dustymorrison674411 ай бұрын
Just watchedbuour video very helpful after the tests i come to learn my compressor is not turning off. Inthought it wasnthe thermostat. So i replaced it and found this problem. Does that mean i need a new compressor? Im new to vending machines.
@sampatel2021 Жыл бұрын
Thanks for the video and info. I checked my Dixie narco 276e machine and evaporator and condenser fan is fine but not cooling. I did the 15 mins test as per video and no frost in the evaporator coil. Does this signify the compressor is bad or leak?
@lentil6110 ай бұрын
Thank you for your videos. They are awesome. I have a Vendo 720 and the evaporator it's icing over. I'm not sure how to test the thermostat to see if it's bad before I have to replace the compressor. Any help?
@fields50036 ай бұрын
Did you ever figure it out?
@MichaelBeechy-zn8vo4 ай бұрын
who do you call to come out and service them
@christoffer48624 ай бұрын
The owner of course
@MichaelBeechy-zn8vo4 ай бұрын
@@christoffer4862 course?
@UFObuilder Жыл бұрын
Thanks for the information 👍
@VendingMachineSupport Жыл бұрын
Happy to learn that you found this useful.
@franciscaramirez2342 Жыл бұрын
Hello sir so i got a beat up choice vendo machine and i mean the i had to do body work to it the door was bend Ll bad anyways i was real proud of my self cus i fix the door i also got the compressor and the fan aslo the condenser n fans anyways so i was excited right but once i check it to see if it was cold i was shocked it was not cold becus everything was good any ways i been try to see whats up with that and my guess is could the capillary tube need to be replaced cus its look bad its all original from the late 1960s any ways hope to hear from you sir gracias
@richardbohnert1140 Жыл бұрын
Ok one thing that we should do with these machines is blow out your condenser coils. This should be the first thing that you do. I work on ice boxes for a ice company. If you can't see thru them it's not a good sign.
@VendingMachineSupport Жыл бұрын
Excellent tip Richard. I should have mentioned that. Thank you for sharing.
@RandyNO611 ай бұрын
Hey when you say blow them out what do you mean? And what would you suggest doing that with?
@richardbohnert114011 ай бұрын
You can do that with compressed air.
@judycruz6023 Жыл бұрын
Hi. My Royal 650 has a lot of ice build up around the entire evaporator coil. How can I thaw it out while preventing any leaks at the location? Where should drip pans be placed? Should I remove the chute like you did in your test?
@VendingMachineSupport Жыл бұрын
You will want to unplug the machine and let the ice melt off while keeping a towel near the bottom of the machine to soak up any overflow water. You can also use a hair dryer to help accelerate melting the ice. Please do not chisel or poke at the ice as this can damage the evap coil.
@Oasis_Vending Жыл бұрын
@@VendingMachineSupporthow do you test the electronic temperature sensor on a Royal 650?
@amason9801 Жыл бұрын
hey do you have anymore info on the vendos I just bought one and would like to find more info or videos on it
@VendingMachineSupport Жыл бұрын
I hope to have some recorded in the future.
@austingrant5660 Жыл бұрын
Same here bro there no videos on them i got my compressor working right ,i can,find the evaporator fan well I mean I can't find a way to get to it , anyways. You should,post a video of your vendo machine
@burnoutawd Жыл бұрын
I have a dixie narco 276 just restored the entire machine. Replaced the compressor housing with a new compressor and rebuilt evaporator and condenser. I noticed the compressor will run 15min on and 15min off ranging from 35°-37° new thermostat. This unit is installed in my basement which is about 65°. Is this the normal cycle? Or should I start looking for some kind of air leak? I also for the first time fully stocked the machine full of room temp cans and it took almost 6 hours to reach 35 degrees. My evaporator in 15 minutes looks exactly like the one in your video. I found quite a few other videos that say that is perfectly normal, including the company that I bought the refurbished compressor deck from lol. When you had yours looked at, did they say there was something wrong with it??
@VendingMachineSupport Жыл бұрын
From your description it sounds that everything is working ok in your machine cooling wise. Drink vending machines are not energy efficient like your typical modern refrigerator.
@raulperez5471 Жыл бұрын
Compressor seems to work and the evaporator coil is getting cold but I don't see The frost built as seen on your video. I can see light frost on the sides and on the tube in the front.
@VendingMachineSupport Жыл бұрын
Your unit may be low on charge or has a blockage in the lines. Might want to call in a HVAC mechanic.
@nelsonrosado42155 ай бұрын
The magnets aren't spinning fast enough on my vendor jet spray machine. What can I do to speed them up
@nicholasdcarlson Жыл бұрын
My compressor is hot and the soda isn’t cooling but the tubing feels cold thanks for your help!
@VendingMachineSupport Жыл бұрын
Is your Evap fan working as shown in the video?
@ethanirwin36152 жыл бұрын
I’m try to diagnose my Dixie-Narco and it fails the thermostat test but it also doesn’t get frosty on the coils. Should I replace the thermostat and try the frost test again?
@VendingMachineSupport2 жыл бұрын
@Ethan Irwin If the evaporator coils did not get frosted over within 15 minuted when connecting the compressor directly to power (which bypasses the thermostat). Then replacing the thermostat will not produce a different result. Make sure when you tested the compressor you did this with the machine unplugged from the wall and the compressor connected directly to power via an extension cord.
@joewilliams5283 Жыл бұрын
I recently purchased a Vendo 516. The condenser isn't getting cold. I can't find ANY information on replacements. Do you have any suggestions or if there are replacements for it?
@VendingMachineSupport Жыл бұрын
The Vendo 516 is an older Vendo unit and new units are hard to come by. I would look for a locally owned and independent HVAC mechanic or appliance repair to have a look at the unit. These cooling decks are very simple in the grand scheme of cooling units.
@soup3rd609 Жыл бұрын
The whole back part and pipes are just pure frost and it’s not warming up the drinks. What might be the exact issue for that?
@VendingMachineSupport Жыл бұрын
Check to make sure the evap fan is running.
@raulperez5471 Жыл бұрын
My condenser fan takes time to turn on is that a concern? When it turned on, I moved the Thermostat to 0/0ff and the fan turned off. Does the fan take a while to turn on or is it supposed to be immediate
@VendingMachineSupport Жыл бұрын
Typically the condenser fan should start as soon as power is applied to it. Unless there is a time delay device which I have only seen once. If the condenser fan is taking some time to start up there is a good chance that it is also not running at full RPM. In turn reducing the amount of air that is pulled through the condenser coil and over the compressor head. This causes overheating and problematic cooling issues.
@donnieb78182 жыл бұрын
I just bought a royal 660-9 & having the same problem with the machine , I can't get the compressor to turn on when it's plugged into the power harness but when I unplug the compressor & plug it into an extension cord the compressor kicks on no problem, I'm brand new to this vending business & would appreciate your expertise, Thanks!!!
@VendingMachineSupport2 жыл бұрын
@Donnie B From your description and trouble shooting steps. It sounds like you could have a faulty refrigeration relay. The Royal 660 was designed by Coke-Cola but manufactured by Royal Vendors for Coke Asset Operators. The 660 shares some similarities to the Royal 650. I have several videos about the Royal 650. Two of which deal with the refrigeration relay. This relay can be tested from the control board to determine if it opens and closes. The 660 uses a four button programing as the Royal 650 uses the a three button programing. Though the concept I show in the videos can be applied to the 660. How to test the Royal FRIG relay: kzbin.info/www/bejne/r3rKdax5p6eearM Troubleshooting a Royal FRIG relay with a voltmeter: kzbin.info/www/bejne/a4S8iqV_o5inj9U If the relay opens and closes when tested with a voltmeter then the issue is the actual power junction assembly that the compressor plugs in to. I hope the gets you pointed in the right direction. Thank you for watching and supporting.
@donnieb78182 жыл бұрын
@@VendingMachineSupport Thank you sir, I'm gonna take a look at it today, I appreciate the info Thanks 👍
@ricktumaniec6820 Жыл бұрын
I have an 85 coke machine, cools great but the condensation won't drain to the pan or through the hose to the pan. how do I unclog it?
@VendingMachineSupport Жыл бұрын
Try running a long brush through the pipe.
@brianiswrong Жыл бұрын
Or connect a few cable ties together and poke it down the drain hole (under the evaperator) until you see it poke out the end of the tube.
@thirdgearboogie2210 Жыл бұрын
AMS 39 VCF That keeps leaking water on the floor. How do I fix this.
@VendingMachineSupport Жыл бұрын
There is a drain hose that takes the water coming from the pan that sits beneath the evap coil and deliveries it to the drain pan. Check to make sure the hose is attached correctly or not clogged. Also make sure the hose is actually sitting in the drain pan.
@josedavidgamez5026 Жыл бұрын
So what is happening when the coke cans are over freezing literally lost like 40 cans due to them bursting in machine . It was winter in Texas but last month could drinks have over froze due to outside temperatures?
@VendingMachineSupport Жыл бұрын
You need to establish what is the temp inside you machine. Stick a thermometer in the machine. You are looking for temps between 40F to 36F. Diet drinks freeze at 34F while other type of drinks and water will freeze at 32F. If the temp in your machine balances out between 40F and 36F after letting the machine run for a few hours. Then the freezing cold be due to outside temps.
@scottytroublefield205 Жыл бұрын
Mine is freezing up can you tell me what may be causing it??? DN 501e
@scottytroublefield205 Жыл бұрын
My motors at bottom and top are working.
@VendingMachineSupport Жыл бұрын
Possible could be the thermostat not shutting down the compressor or the machine is leaking outside air in.
@jamalhinds1 Жыл бұрын
So my Coils are froze up in a block of ice, I check the thermostat like you said in the video turning it until the compressor kicks on and off. While the compressor is off I was able to hear the blower fan behind the block of ice also I can see the compressor fan spinning. I shut the machine down for a day to let ice thaw to visually inspect the coils there was some slight browning at the bottom but not much. With the machine back on for a day I returned and the ice started build back up, please help.
@VendingMachineSupport Жыл бұрын
What happened to the evap coils after running the compressor directly to power for 15 minutes with the machine unplugged?
@jamalhinds1 Жыл бұрын
The pass through is on the left side of my machine. Will the deep refrigeration unit on DSV still work