How To Test - Air Conditioner Fan Motor

  Рет қаралды 259,165

More350Power

More350Power

11 жыл бұрын

typical window unit fan motor

Пікірлер: 67
@More350Power
@More350Power 11 жыл бұрын
Thank you, hope things are going well your direction.
@805ROADKING
@805ROADKING 11 жыл бұрын
Good stuff Mate!!☺
@froberson
@froberson 9 жыл бұрын
Great video. Thanks. Tested just as you indicated. Bad motor. Replaced and we're back up and running. Very helpful.
@More350Power
@More350Power 8 жыл бұрын
+F Rob glad it helped, thanks !
@jollyscaria1922
@jollyscaria1922 2 жыл бұрын
Thankyou gues
@More350Power
@More350Power 11 жыл бұрын
Thanks, it is easy once you know the usual wire colors..... sometimes they do change.
@justin91476
@justin91476 11 жыл бұрын
really cool stuff!! Now lets get some video of you blowing some stuff up lol ;)
@bridchvtruck568
@bridchvtruck568 11 жыл бұрын
good vid thanks :-)
@More350Power
@More350Power 11 жыл бұрын
Thank you.
@AlchemistLair
@AlchemistLair 11 жыл бұрын
Electric motors are fascinating!!
@More350Power
@More350Power 11 жыл бұрын
thanks lol, I gotta work on getting some stuff..... I hate to kill a good motor.
@RobsPackanShine
@RobsPackanShine 11 жыл бұрын
Good stuff
@RodderFiles
@RodderFiles 11 жыл бұрын
stuff i didnt know b4 kool.
@More350Power
@More350Power 11 жыл бұрын
Appreciate the comment, its hard to keep up on comments on vids..... will pm you my addy here in a sec, thanks !
@More350Power
@More350Power 10 жыл бұрын
this one isnt, being its from a large window unit, most of them are now, especially the central ac units
@More350Power
@More350Power 11 жыл бұрын
Is that how you get your hair to stand on end ?
@More350Power
@More350Power 11 жыл бұрын
I am tempted....
@driverx57
@driverx57 6 жыл бұрын
Erm that motor didn't have a start capacitor? Seems it's not at full speed without it? Most A/C units do have one.
@More350Power
@More350Power 6 жыл бұрын
surprisingly this one did not require one. I thought the same thing but the wiring schematic and the way it was wired when I tore the guts out of the window unit didnt have one in it, just for the compressor.
@Dive-Bar-Casanova
@Dive-Bar-Casanova 6 жыл бұрын
Called a shaded pole motor.
@caru3257
@caru3257 6 жыл бұрын
Run cap is the one they use. I replace many a cooling season.
@hextremelydesirable1648
@hextremelydesirable1648 2 ай бұрын
@@Dive-Bar-Casanovathe only thing that is shaded is your crypto wallet after all these years. It’s not too late for you with PULSECHAIN $0.00008
@BM-jh3gx
@BM-jh3gx 9 жыл бұрын
Can a bad fan motor damage a new capacitor? My fan stopped spinning in my ac unit. I put in a 40/5/440 capacitor (made by different company than what was in unit...both are 40/5/440). The fan ran for about 45 min then stopped and would not turn on again. Both capacitors are rated -6% +6%...whatever that means.
@More350Power
@More350Power 9 жыл бұрын
Bryan McDaniel the plus and minus 6 percent is the tolerance range so when you test them if they are plus or minus 6 of what they are rated, they are considered ok. I believe. a bad motor can damage a capacitor though sometimes you can get a bad cap to begin with......
@bchaveezy
@bchaveezy 9 жыл бұрын
That thing needs some 220V power!!
@More350Power
@More350Power 9 жыл бұрын
Brandon Chavez yup !
@suhailasaba1051
@suhailasaba1051 4 жыл бұрын
Good video Question : I have a one and a half ton 220volts split unit AC. After few seconds of turning it on the clamp meter reads 22A then rise to reach 37A for few seconds then it stops and the clamp meter reads zero or 0.1A What could be the problem?
@More350Power
@More350Power 4 жыл бұрын
It sounds like something could be fried, capacitor, motor..... hard to say without seeing it. Do you know what the RLA is on the unit ?
@suhailasaba1051
@suhailasaba1051 4 жыл бұрын
@@More350Power Thank you for your answer I will check the capacitor. I will try to find out the RLA of the motor. Thank you.
@tnridge
@tnridge 11 жыл бұрын
no gasoline or torches were used in this video..LOL
@LubaLuba1
@LubaLuba1 10 жыл бұрын
I have an old 20 year old YORK condenser unit I think its a 3 ton anyway I want to wire it up I have 4 wires on motor white and black and two brown one of the browns has a white strip. My question which side of the capacitor takes the brown wire with the strip??? or does it matter because I have a capacitor without markings.
@More350Power
@More350Power 10 жыл бұрын
Usually it doesnt matter which side of the run capacitor the leads go to. I have an air handler blower that has two brown leads going to its run capacitor but no markings on the cap itself as to polarity. There is usually a schematic inside the condenser units themselves. I have been trying to get ahold of a york unit for years... more specifically the york stellar series that has the letters Y O R K cutout in the metal going down the side of the unit. Old, but good units they are.
@LubaLuba1
@LubaLuba1 10 жыл бұрын
so is it possible to have a two capacitors I am so confused which of the four wires go where Blk, white, brown and brown w/white strip
@More350Power
@More350Power 10 жыл бұрын
Danny Diet you usually have two or one combined capacitor in a condenser unit. The compressor uses one and the fan motor uses the other. Usually the fan motor capacitor is about 5 microfarads and the compressor 30 to 45 give or take. There should be a diagram on the motor or the inside of the electric compartment on the condenser to state where the wires go. If I had to guess, I would say the two brown leads go to the capacitor and your white and black are your two hots as with 220, you are combining two hots. It is possible the fan motor is 120 volts as well, as usually a white and black lead indicates neutral and hot on 120 volt electric items and red & black or black & black is common on 220 volt items. There are a lot of configurations out there.... if you can find a model number of the motor or condenser you should be able to find a diagram which would tell you for sure how things go together.
@LubaLuba1
@LubaLuba1 10 жыл бұрын
So all seems to work good except AC unit outside stays on after thermostat turns off. What could this be? I did not change contactor with switch yet. Could this be the problem?
@More350Power
@More350Power 10 жыл бұрын
It could be or the wiring could be wired in such a way its bypassing the contactor. Also, sometimes the contactors burn contacts and even when they seem to withdraw from closed position carbon from arcing or melting of the contacts can keep it closed and thus the condenser keeps running. Or, the relay in the air handler and or furnace is not ceasing to send the 24 volts to the contactor, though that command is usually done by the thermostat via the yellow wire.
@myideas2765
@myideas2765 6 жыл бұрын
hello there, When I turn on my air conditioner fan starts working, and the house starts cooling, but after running for about 10 minutes the fan make a squeaky noise and stops working and the compressor overheats. Somebody came here and said that it was the fan motor going bad and that I need a new motor. Can you let me know if motor starts what could be the reasons it stops? Thank you.
@More350Power
@More350Power 6 жыл бұрын
It sounds like the bearings are going bad in the fan motor. That would probably be the source of the squeaking noise and as the motor heats up it seizes. I had an ac unit like that. Would run fine cold, but once the motor got warm it wouldnt spin. In fact after the compressor would over heat, the breaker would trip as well.
@ZanesFacebook
@ZanesFacebook 2 жыл бұрын
I had this with the blower motor in my furnace in a central air setup. When the heat was on, it would make a squeaking sound. Replaced the motor (very easy), for about $54 on my unit, and it's silent now. Fwiw my furnace is about 22 years old and I believe the fan motor was the original
@More350Power
@More350Power 11 жыл бұрын
thanks for watching appreciated !
@More350Power
@More350Power 11 жыл бұрын
thanks for watching !
@eppakayalanaresh818
@eppakayalanaresh818 7 жыл бұрын
Hi my air cooler motor isnt working what i need to check pls let me know it was rotating slow in the morning and later it stopped working, later it was making hum sound and now i dont even here now. 1) is it shorted 2) capacitor fail or ....?
@More350Power
@More350Power 4 ай бұрын
It could have burned up or a bad capacitor if it has one
@Kevinrevenger
@Kevinrevenger 9 жыл бұрын
My one has a black orange and brown can I wire it to my plug which is blue white and black
@More350Power
@More350Power 8 жыл бұрын
+Kevin Ramdial Without knowing the voltage of the motor and the schematic that is sometimes on it..... I wouldnt advise it.......
@sweetypathak5731
@sweetypathak5731 7 жыл бұрын
Hii fan winding connection test kese krte he
@mardoniegojr132
@mardoniegojr132 4 жыл бұрын
what capacitor amperes you used on that fan bro..
@More350Power
@More350Power 4 жыл бұрын
This one did not require a capacitor, but if you find one that does and does not have one attached to it, usually it is listed on the motor label.
@Kevinrevenger
@Kevinrevenger 9 жыл бұрын
Can this hook up to a pulley to move a convey belt?
@More350Power
@More350Power 8 жыл бұрын
+Kevin Ramdial possibly, though it doesnt have much torque.....
@okokc11
@okokc11 10 жыл бұрын
damm that's a good job man
@More350Power
@More350Power 10 жыл бұрын
i like this kind of stuff lol, thanks !
@HeavensProtocol
@HeavensProtocol 10 жыл бұрын
My old GE motor has two wires. What does that mean?
@More350Power
@More350Power 10 жыл бұрын
Probably a single speed motor, but make sure of the voltage 120 / 220.... and the ground usually goes to the casing of the motor
@More350Power
@More350Power 11 жыл бұрын
Thanks for watching !
@VWBusache
@VWBusache 11 жыл бұрын
Cool, thanks.
@More350Power
@More350Power 11 жыл бұрын
Heck yea they are.... im a motor nut so to speak lol
@More350Power
@More350Power 10 жыл бұрын
that is correct..... the motor would either just hum or burn up if you tried it that way....
@More350Power
@More350Power 11 жыл бұрын
speed ?? it will just sit there and smoke...... like you on jumper cables :)
@manuelalvarez7843
@manuelalvarez7843 10 жыл бұрын
look like 220 v motor????
@More350Power
@More350Power 5 жыл бұрын
Nope, suprisingly.... was stamped 115VAC 60hz
@More350Power
@More350Power 11 жыл бұрын
lol, didnt wanna blow anything up yet.... lol
@jonesy4588
@jonesy4588 3 жыл бұрын
I could tell you in 10 seconds with an ohm meter
@More350Power
@More350Power 2 жыл бұрын
That is another way of checking it too, thank you for watching !
Diagnosing a Bad Blower Motor (8 Easy Things To Check)
6:51
Fox Family Heating and Air Conditioning
Рет қаралды 161 М.
Электродвигатель от кондиционера БК - 1500
3:41
Сергей Цебренко
Рет қаралды 45 М.
Wait for the last one! 👀
00:28
Josh Horton
Рет қаралды 119 МЛН
КАРМАНЧИК 2 СЕЗОН 7 СЕРИЯ ФИНАЛ
21:37
Inter Production
Рет қаралды 393 М.
Must-have gadget for every toilet! 🤩 #gadget
00:27
GiGaZoom
Рет қаралды 11 МЛН
TROUBLESHOOTING Wall & WIndow A/C Units(Step By Step)
29:40
electronicsNmore
Рет қаралды 726 М.
Testing Condenser Fan Motor Winding From No AC Callback Video
14:14
The HVAC Hacker
Рет қаралды 21 М.
Fix Air Conditioner Fan Not Spinning
5:56
The Apprentice Survival Guide
Рет қаралды 16 М.
Replacing Air Conditioner Fan Motor Bearings
25:00
Air Conditioners Exposed
Рет қаралды 7 М.
How to repair aircon fan motor
16:12
KAFIX Vlogs
Рет қаралды 14 М.
How to Replace a condenser fan motor
7:29
SuperCool Slide Rule
Рет қаралды 157 М.
RV Air Conditioner or Fan Won’t Start? DIY Easy Fix
9:35
Doing Things Dan's Way
Рет қаралды 159 М.
Ценовая война на рынке электрокаров
1:00
Кик Брейнс
Рет қаралды 718 М.
Choose a car for Daughter ❤️ #car #automobile #viral
0:16
Drive Vibes
Рет қаралды 3,3 МЛН