How to Test Air Conditioner sensor / Easy to Check Air Temperatur & Coil sensor with cool water/HVAC

  Рет қаралды 32,961

Chill Tech AIRCON

Chill Tech AIRCON

3 жыл бұрын

AC SENSOR
How to Test Air Conditioner sensor
Easy to Check Air Temperatur & Coil sensor with cool water
Inverter ac are now inverter ac sensor
how to analyse the sensor complaint
sensor check with cool and hot water
ac no cooling problem
air conditioner sensor testing best trick with digital multi meter
#CHILL #TECH #AIRCON
Subscribe my KZbin channel link
/ @mohammedsiddiq.s1111
How to do Air Conditions filter service in home
• How to do Air Conditio...
Air Conditioning cycle working principle in Tamil
• Air Conditioning cycle...
Ac outdoor Fan motor Connection of 4 wire
• Ac outdoor Fan motor C...
AIR CONDITIONER RUNS BUT DOESN'T COOL
*sometimes the air conditioner can run and you don't feel any cool air.
-it is important to check the therostat although it might not be the problem.
-check whether the condenser is dirty,clean it and remove any dirt.
-inadequate amount of refrigerant in the system can be the cause of this problem and it can be addressed by a professiona.
-check the air compressor whether it is running by listening to it and checking for the power light.
-check the compressor or condenser coil whethe it is blocked or damaged

Пікірлер: 64
@miyankaja257
@miyankaja257 Жыл бұрын
Very clear demo and super 👌 Electronic companance banfits bathi oru video bannunga Ac la vara parts Spilt,cassat,Fcu,Vrf
@rajasekarv5474
@rajasekarv5474 Жыл бұрын
fine demo thankyou.
@jayaramanthangarajan6020
@jayaramanthangarajan6020 2 жыл бұрын
Very clear explanation. I had a experience like in lecture's teaching. Thank you.
@Mohammedsiddiq.s1111
@Mohammedsiddiq.s1111 2 жыл бұрын
TQ 😍
@Arunkumar....7683
@Arunkumar....7683 Жыл бұрын
Super really great 👍
@yuvisiddh1650
@yuvisiddh1650 3 ай бұрын
Clear explanation 👍 Good work. But please correct clamp meter not it's multimeter. I think you know that clamp and multimeter different.
@kuttyraja1
@kuttyraja1 Жыл бұрын
Nice explanation, we have old Panasonic ac, in this no display provided ,can we fix separate display for knowing temperature
@sivakavigobalakrishnan1166
@sivakavigobalakrishnan1166 Жыл бұрын
Ethu pol niraiya video podunga Ji, thanks 🙏
@Mohammedsiddiq.s1111
@Mohammedsiddiq.s1111 Жыл бұрын
OK 😊
@Basithmohammed-if6cn
@Basithmohammed-if6cn Жыл бұрын
Supper bro ❤
@RasikpaPoovathungal-cn7wd
@RasikpaPoovathungal-cn7wd 6 ай бұрын
❤👍 thanks
@gvnithi8905
@gvnithi8905 3 жыл бұрын
Nice! Bro,. Please upload trouble shoot about inverter ac.
@Mohammedsiddiq.s1111
@Mohammedsiddiq.s1111 3 жыл бұрын
Ok bro I will trying 😊
@mohamedaashikn3335
@mohamedaashikn3335 6 ай бұрын
One suggestion: Please mention “in tamil” in every video you made in tamil. Because oru vela hindi ah irukumo.. seri irundhutu potum nu tha ulla vandhen. But tamil la irundha odane I am very happy. So please mention it.
@harikrishnankannan6386
@harikrishnankannan6386 5 ай бұрын
Super bro
@gowthamcomrade7758
@gowthamcomrade7758 3 жыл бұрын
Good explanation do well my dear
@Mohammedsiddiq.s1111
@Mohammedsiddiq.s1111 3 жыл бұрын
TQ DEAR🥰
@rangaranga2526
@rangaranga2526 4 ай бұрын
Good
@rajkumarsumathi4278
@rajkumarsumathi4278 Жыл бұрын
Super bro. Onida inverter split AC E5 next 5E error code what is the complaint how to solve the problem
@suraj1297Ss
@suraj1297Ss 3 жыл бұрын
Superb Macha
@Mohammedsiddiq.s1111
@Mohammedsiddiq.s1111 3 жыл бұрын
TQ FRIEND 😍
@rameshkumark3947
@rameshkumark3947 3 жыл бұрын
I support bro. Super
@Mohammedsiddiq.s1111
@Mohammedsiddiq.s1111 3 жыл бұрын
TQ BRO😍😍😍
@yashiha2020
@yashiha2020 3 жыл бұрын
Super bro...
@Mohammedsiddiq.s1111
@Mohammedsiddiq.s1111 3 жыл бұрын
TQ Anna 😍
@elanchezhian.selanchezhian2374
@elanchezhian.selanchezhian2374 Ай бұрын
நன்றி
@fishandpets7866
@fishandpets7866 Ай бұрын
Bro coil sensor and room sensor value renduma 7.5 sama irrukuma
@msraghul3648
@msraghul3648 Жыл бұрын
Hi bro my one year old lg 1.5ton convertible AC is not colling to my set temperature (eg) if i set my ac at 22 even after 8hrs of running room temperature is remain in 28°
@bilalhasan1369
@bilalhasan1369 11 ай бұрын
Super bro my ac EC error code what is this tell me bro
@rangaranga2526
@rangaranga2526 4 ай бұрын
Bro remote and indoor unit sensor check
@yonam4299
@yonam4299 2 жыл бұрын
Super bro and what's happened f3 error starting time 2 r 3 times showing after working good voltas inverter split ac
@Mohammedsiddiq.s1111
@Mohammedsiddiq.s1111 2 жыл бұрын
Outdoor unit pcb IBM module fault bro
@shahuls5463
@shahuls5463 Жыл бұрын
Bro split ac oru 5 minutes run anathuku apuram.. Automatica off aguthu.. Then marupadiyum running agula appo enna problem bro ithu..
@jayalakshmi4524
@jayalakshmi4524 Жыл бұрын
Sensor enna rate varum sir
@MdRizwan-yw9ti
@MdRizwan-yw9ti 5 ай бұрын
Bro Inverter split AC ka indoor aur Temprature sensor aur coil sensor ka value kitna hona chahiye.please reply
@arunswamy7155
@arunswamy7155 5 ай бұрын
Super❤
@Mohammedsiddiq.s1111
@Mohammedsiddiq.s1111 5 ай бұрын
THANKS YOU
@karthikrajah6775
@karthikrajah6775 2 жыл бұрын
👌Super bro, my AC voltas 1.5 ton coil sensor is dead, but which value sensor I have to change 10k, 15k, 20k? Please tell me, thank you
@Mohammedsiddiq.s1111
@Mohammedsiddiq.s1111 2 жыл бұрын
8K to 10k bro
@Mohammedsiddiq.s1111
@Mohammedsiddiq.s1111 2 жыл бұрын
TQ 😊
@muhileswaran7831
@muhileswaran7831 2 жыл бұрын
Hii bro godrej ac la work aagite irukum bodhu sudden ah light twice blink aagitu E2 nu display la kaatuthu apdiye wings close aaiduthu......user manual la the fault of indoor pipe temperature sensor nu iruku ithu epdi solve pananum ??
@Mohammedsiddiq.s1111
@Mohammedsiddiq.s1111 2 жыл бұрын
Indoor sensor is fault you change same value sensor
@shanmugamshanmugam7697
@shanmugamshanmugam7697 3 жыл бұрын
I support ji
@Mohammedsiddiq.s1111
@Mohammedsiddiq.s1111 3 жыл бұрын
TQ ANNA😍
@dowlathmohammed8585
@dowlathmohammed8585 3 жыл бұрын
Super
@Mohammedsiddiq.s1111
@Mohammedsiddiq.s1111 3 жыл бұрын
TQ 😍
@dowlathmohammed8585
@dowlathmohammed8585 3 жыл бұрын
super KZbin enjoy
@thameemansari5108
@thameemansari5108 9 ай бұрын
Hi bro AC compressor continuesly running not cut off
@jmanibharathyjmanibharathy3649
@jmanibharathyjmanibharathy3649 11 ай бұрын
Sir ethu multimeter
@uvanmusik5590
@uvanmusik5590 2 жыл бұрын
Bro my normal split ac (Not inverter type) automatically changing modes and switched off automatically.. for the past 2 days.. Its running and cooling also coming but suddenly modes are changing and switched off. What may be the problem.. Any solution??
@Mohammedsiddiq.s1111
@Mohammedsiddiq.s1111 2 жыл бұрын
Bro you check indoor PCB board
@BeingConscious2705
@BeingConscious2705 Жыл бұрын
Haier service sensor cost they cost 950? Is the real price?
@vijayvenkatesan9773
@vijayvenkatesan9773 4 ай бұрын
Hi bro
@Mohammedsiddiq.s1111
@Mohammedsiddiq.s1111 4 ай бұрын
Hi bro
@devinchan7531
@devinchan7531 Жыл бұрын
Athu clamp meter illa multi meter correcting from 🇲🇾
@therasemagdalin4334
@therasemagdalin4334 2 жыл бұрын
O.k
@Mohammedsiddiq.s1111
@Mohammedsiddiq.s1111 2 жыл бұрын
😍
@gunavenkatesan7875
@gunavenkatesan7875 Жыл бұрын
MY AC NOT ON , WHAT PROBLEM BROTHER
@Mohammedsiddiq.s1111
@Mohammedsiddiq.s1111 Жыл бұрын
Hmm call me 9715181086
@bharathsekarkalai866
@bharathsekarkalai866 Жыл бұрын
Super bro
@dhanushdhanush2592
@dhanushdhanush2592 2 жыл бұрын
Super bro
@Mohammedsiddiq.s1111
@Mohammedsiddiq.s1111 2 жыл бұрын
TQ 😍
Anyone can repair PCB now!!
13:29
Engineering Facts
Рет қаралды 702 М.
THEY made a RAINBOW M&M 🤩😳 LeoNata family #shorts
00:49
LeoNata Family
Рет қаралды 43 МЛН
39kgのガリガリが踊る絵文字ダンス/39kg boney emoji dance#dance #ダンス #にんげんっていいな
00:16
💀Skeleton Ninja🥷【にんげんっていいなチャンネル】
Рет қаралды 8 МЛН
🤔Какой Орган самый длинный ? #shorts
00:42
THERMISTOR Operation and Testing! Inverter and Mini Split Training!
5:41
AC Service Tech LLC
Рет қаралды 105 М.
Easy To Check Air Conditioner Temperature Sensor With Cool Water
8:25
9 major reason of AC compressor overheat and trip problem in Tamil
4:29
Tamil Thedal vettai
Рет қаралды 20 М.