Calculate Solar Cost For Your Home - geni.us/solar_reviews Power Kit I Used - geni.us/uRL6gJ Correction: PVC should be buried 18 inches deep not 12 inches as noted in the video. If you need to go shallower consider installing galvanized metal electrical conduit which can be buried 6 inches deep. DISCLAIMER: This video is for entertainment purposes only. Also, this video and description contain affiliate links, which means that if you click on one of the product links, I’ll receive a small commission.
@MrWotok10 ай бұрын
Thanks for the video! Great explanations on the various steps of your project. Before plugging in the EcoFlow, however, I would have connected the panels and did one final polarity test on the connector. It could save some headaches for some DIY'ers if they had the pos and neg backwards.
@Moes_Prep_and_Tech10 ай бұрын
if you were to have panels on the shed roof is it possible to connect it with the trenched connection?
@AaronBrand2 ай бұрын
I’ve read that it’s best to have the array switched if you are using quick connect ends; over time, arcing can damage the interior of the connector if you are connecting or disconnecting while the panels are generating any current.
@ronaldnaeyaert365310 ай бұрын
Did you use schedule 80 for part of conduit run above ground
@ididitallforthechinookie6 ай бұрын
Thanks!
@Electronzap10 ай бұрын
Cool project.
@Jiangster10 ай бұрын
Did you consider mounting the panels on the roof of your shed?
@JohnBaker300010 ай бұрын
Be sure to add slip joints if your area frost issues.
@everydaysolar10 ай бұрын
Thanks for the feedback 👍
@FelixtheMetalcat10 ай бұрын
Great video and easier than I expected. I CAN DO THIS!!
@andrewdunham897310 ай бұрын
What sort of pliers(?) are you using at 6:40 to strip the wire?
@Paulwilliams20310 ай бұрын
Brilliant, very informative and great subject to cover 👍🏻
@philsmock494310 ай бұрын
Ok, you lost me on why you switched the colored wires around in the shed. Black to red and red to black. Is it because you have two black male mp4 jumper connectors and two red female jumper connectors? Otherwise, you would have needed one black male and one black female jumper to keep the black wire the same throughout the run. Same for the red. As I'm writing this, I am kind of figuring out why myself. Your wires from the solar panel both need a mail connector on one end and a female connector on the other end to work like an extension cord. I think I got it now. Thanks for putting this video out there.
@AlarmProGuy10 ай бұрын
You need to run an equipment ground wire and ground the frames of the panels …
@embp164710 ай бұрын
Hey, what type of PVC conduit are you using, and where in the code allows for 12 inches? That will save me so much work. Thanks.a
@kayakingphotos10 ай бұрын
And please provide code reference to this question as well.
@everydaysolar10 ай бұрын
I used schedule 40 and I was mistaken the PVC should be 18 inches deep not 12 inches.
@shelley13110 ай бұрын
Why did you connect the black and red wire together?. Sorry , did not understand,
@rcguymike10 ай бұрын
For 200W worth of panels it'll take like 50yrs just to offset the cost of the conduit? Seems like a perfect scenario for direct bury. Although you probably just did this as a demonstration?
@everydaysolar10 ай бұрын
Yeah, this one was a bit more for demonstration for those times where the grid is not close or convenient. 👍