Thanks for the video!, looks like there is a mistake on 9:34 , the min is 0 and the max is 27648 is it ?
@plcgoods3 жыл бұрын
Thanks so much for watching our videos carefully. You're right and I mentioned this matter before testing (Time 15:20)
@nareshsekar48072 жыл бұрын
Hi Sir, (At Time = 14:45). What will happen if we didn't right the line "Move "0" to Electric Valve" if the level is not below 5. Will the Electric Valve still be open for 16mA current. If the level is not below 5 then the MOVE instruction will not move any value to the Electric Valve so the output analog current will be zero right then why should we have wright this line?
@plcgoods2 жыл бұрын
Hi there, If the MOVE instruction is not enabled, then it won't do anything. In this condition, If "Electric Valve" is open, it remains open, and if it is closed, it remains closed as well. So, I needed to write the line "Move 0".
@nareshsekar48072 жыл бұрын
@@plcgoods Thank you so much sir
@lessspeech71294 жыл бұрын
Very Good!Thanks
@plcgoods4 жыл бұрын
Thank you too! :)
@SLEtec-e3 жыл бұрын
Nice work
@plcgoods3 жыл бұрын
Thank you! Cheers! and welcome to the channel!
@Dirson20013 жыл бұрын
Hi all, vhen I have a defective Analog I/O module Sinad 6ES7232-4HB32-0XB0, the red LED starts blinking to show me the fault. Can I simply substitute the old defective to a new one or we must manage the soft for the new module recognization? thanks a lot.
@plcgoodsmentor92233 жыл бұрын
Hi there, I've never had your problem, but In my opinion, you can substitute the defective module to a new one with the same model. one time, I changed my CPU module with a similar CPU, and then transferred my project without adjusting the CPU model inside my program. it worked correctly.
@plcgoodsmentor92233 жыл бұрын
Also, If you want to use another type of analog module (with the same input type), you can transfer the PLC program to your computer, modify the selected analog module inside the hardware configuration window, and then transfer the modified program to your PLC
@plcgoods3 жыл бұрын
thanks for checking out the channel
@msizingcobo99502 жыл бұрын
Thank you for the tutorial but how to do the conversion blocks using s7 300 cpu since the norm_X & scale_X don't appear when selecting s7 300 cpu
@plcgoodsteam89342 жыл бұрын
Hi there, note that each PLC may support some instructions that maybe are not used with the others. Also, now we are preparing a course about S7 300. It can help you to use analog signals with S7-300 PLCs.
@plcgoods2 жыл бұрын
Thanks for checking the channel out!
@irelandlotelugufamily20194 жыл бұрын
Hi Can you please help me as i am new to this programming world What is the difference between |RAW value and Scaled value do they need to be same always
@plcgoodsmentor92234 жыл бұрын
Hi, usually they are not the same. If you have a 13-bit resolution analog input channel, your raw input range is 0 to 2^13 = 8192, 0 representing the minimum value of your analog signal, 8192 representing the maximum value. analog input modules are suitable for a specific range. If you set it up for 0-20mA, and you connect a 4-20mA sensor, you won't have 0 as a raw value when the sensor output is minimum (4mA). If you want the 4-20mA to represent a water level between 10 and 300 cm, then that is your engineering range, also referred to as scaled range. usually, PLCs have some instructions to scale the received RAW value according to the next formula scaled value = (raw value * factor +offset) * unit of measurement
@plcgoods4 жыл бұрын
thanks for the inquiry
@irelandlotelugufamily20194 жыл бұрын
@@plcgoodsmentor9223 Thanks very much for you reply So basically i am an Automation Validation Engineer, While performing FAT f on one of the systems on the HMI they are displaying RAW value and Scaled value for all the analogs of same make and model and signals are coming from same Festo but i see the difference between them is ns 3 deg and for some transmitters it is 0.2 deg . My concern is which is actual field value . If we consider Raw value as actual field value, then i will ask them to calibrate the Instruments . Sorry for this long reply
@abdalishah87212 жыл бұрын
Sir how to create bridge saw machine plc program?
@plcgoods2 жыл бұрын
Answered already!
@abdalishah87212 жыл бұрын
Verry Good Sir please tell me abot multi blade bridg saw machine plc
@plcgoods2 жыл бұрын
this question is already answered!
@ahmedafifi29844 жыл бұрын
Very good 👍 Wanna be friends!!
@plcgoods4 жыл бұрын
we are already friends, do not be worry!
@dispositivosautomatizados2 жыл бұрын
👍🇧🇷
@plcgoods2 жыл бұрын
Glad to help! Thanks for your comment and concern
@chrismerani53303 жыл бұрын
the terrible ai voice is unbearable.
@plcgoods3 жыл бұрын
Thanks for checking the channel, it seems to me you paid more attention to the voice-over than the content quality. I am using Babalola which I guess is an excitingly fabulous program.
@chrismerani53303 жыл бұрын
@@plcgoods that's the point, I can't get past the voice over to even appreciate the content. I would rather hear a real human's broken English than a terrible robotic ai voice that sounds like it is from 1987