Пікірлер: 28
@sumantbayanker7353
@sumantbayanker7353 7 жыл бұрын
excellent training material, have sent it on to my colleagues who run a Shipping company, well appreciated. Thanks
@absalomachieshatumbu8235
@absalomachieshatumbu8235 6 жыл бұрын
Happy to be part of this
@lukekilele5289
@lukekilele5289 3 жыл бұрын
I love this , it's make it easy to understand. plz continue
@academicmistakegaming
@academicmistakegaming Жыл бұрын
Brilliant content, so easy to understand!
@georgezorbalas3619
@georgezorbalas3619 7 жыл бұрын
Great videos
@gauravrade8908
@gauravrade8908 3 жыл бұрын
You are AWESOME👍👍👍👍👍
@chuckp2989
@chuckp2989 4 жыл бұрын
System pressure question. About 3:25 min into the video, the system is set up with the center 100 PSI check valve closed. This leaves the upper left 100 PSI check valve in series with the 300 PSI check valve in parallel with the 100 PSI and 200 PSI check valves. It takes 100 PSI to crack the first check valve and another 300 PSI to crack the 300 PSI valve for a total of 400 PSI. The 400 PSI fluid pressure hits BOTH the 100 PSI and 200 PSI check valves simultaneously opening them both up. The flow through each check valve in parallel will differ but there should be flow through both none the less because it takes 400 PSI just to get to them. If simplified valve resistance is calculated like electrical resistance, then you would use the product-sum rule [(200*100)/(200+100)] to find the total resistance of the parallel valves. In this case, the parallel resistance adds 66 PSI to the system. Shouldn't the total system pressure be 466 PSI not 500 PSI?
@michaelfinck4994
@michaelfinck4994 4 жыл бұрын
In the scenario you mention, no flow is going through the 200psi valve. Work from right to left. The right segment will not reach the 200psi needed because in parallel, flow take the easiest path and the 100psi valve will open first, preventing the valve above ever seeing the pressure needed to open. Moving left, you add the pressure needed to open the 300psi valve, making the segment to its left be at 400psi. Moving left again, also in series we add the next 100psi, hence 500psi at the gauge. The resistor analogy works for flow through parallel pipes of different diameters, but not for parallel check valves. They are either open or closed, as soon as the 100 psi is reached, ALL the flow takes that path.
@migueljrgalutan5090
@migueljrgalutan5090 3 жыл бұрын
Sir gud am, I would like to ask the normal reading of hydraulic pump of the excavator (psi) Thank you.
@justinn7777
@justinn7777 4 жыл бұрын
what is the last two check valves are 100 Psi EACH INSTEAD OF 100 AND 200 PSI ?? PLEASE REPLY !!!
@vasiledan539
@vasiledan539 3 жыл бұрын
I like
@Grunzaa
@Grunzaa 3 жыл бұрын
God the music is intense with headphones
@MrAlamanaseer
@MrAlamanaseer 7 жыл бұрын
what software do you use to simulate hydraulics??
@lunchboxsessions
@lunchboxsessions 7 жыл бұрын
Our team of artists/animators/programmers draw the graphics in a vector drawing program (like Adobe Flash or Adobe Illustrator), and then write the the code (JavaScript) that drives the simulation. The simulations run right in a web browser, like any web page. In other words, we build them from scratch! I hope you've been enjoying our videos, and thanks for the question.
@MrAlamanaseer
@MrAlamanaseer 7 жыл бұрын
fantastic really good job and keep making this, especially about hydraulics
@jordiperez2519
@jordiperez2519 5 жыл бұрын
Congrats, great work !
@shoebahmed7980
@shoebahmed7980 3 жыл бұрын
How to solve hydraulic high pressure problem.
@JLPaper7
@JLPaper7 3 жыл бұрын
it isn't possible for the flow to go for both branches? What will be the pressure then, that is something isn't clear.
@MrAbhinavgour
@MrAbhinavgour 3 жыл бұрын
In reality flow will go through both lines but it will be very small through the top branch.
@gauravrade8908
@gauravrade8908 3 жыл бұрын
It is already stated in the video that each line is large enough to allow whole pump flow through any on loop
@zabidi59
@zabidi59 10 ай бұрын
Do like to share this video please.
@hrishikeshghare4610
@hrishikeshghare4610 2 жыл бұрын
🤠🤠
@johnaugustesen1962
@johnaugustesen1962 4 жыл бұрын
God video but annoying drum sound
@michaelzajac5284
@michaelzajac5284 7 жыл бұрын
Use to help that Math?
@lunchboxsessions
@lunchboxsessions 7 жыл бұрын
Did you spot a mistake in the video? At which time?
@michaelzajac5284
@michaelzajac5284 7 жыл бұрын
Not at all. I understand, I was read my book.
Why Pressure Depends on Piston Surface Area
2:37
LunchBox Sessions
Рет қаралды 23 М.
How To Read Hydraulic Power Unit Schematics
9:16
LunchBox Sessions
Рет қаралды 353 М.
快乐总是短暂的!😂 #搞笑夫妻 #爱美食爱生活 #搞笑达人
00:14
朱大帅and依美姐
Рет қаралды 13 МЛН
Из какого города смотришь? 😃
00:34
МЯТНАЯ ФАНТА
Рет қаралды 2,6 МЛН
When u fight over the armrest
00:41
Adam W
Рет қаралды 32 МЛН
Мама у нас строгая
00:20
VAVAN
Рет қаралды 11 МЛН
The Difference Between Pressure and Flow
7:34
Jack Weeks
Рет қаралды 533 М.
Pressure Drops in Series Circuits
5:11
LunchBox Sessions
Рет қаралды 179 М.
Hydraulic System Inspection & Troubleshooting Session 2
24:10
Hydraulic System Inspection & Troubleshooting Session 1
22:33
How To Adjust a Pressure Switch
7:58
R.C. Worst & Co., Inc.
Рет қаралды 5 МЛН
Pressure Reducing Valves (Full Lecture)
21:21
Jim Pytel
Рет қаралды 77 М.
Hydraulic Power Pack - how it works
6:16
learnchannel
Рет қаралды 413 М.
REXROTH LOAD SENSING DRF DFR PUMP CONTROL EXPLAINED PART 1
10:48
What is Hydraulic Systems? (subtitles | animation)
10:23
Ms. Pneumatic
Рет қаралды 135 М.
快乐总是短暂的!😂 #搞笑夫妻 #爱美食爱生活 #搞笑达人
00:14
朱大帅and依美姐
Рет қаралды 13 МЛН