I’m a new electrician going to college you explain me better than my professor I’m very glad I found this video
@handydadtv Жыл бұрын
Wow thanks 😊
@gretzkyz2 ай бұрын
I second this comment, lol.
@jessicavega98562 жыл бұрын
Best video I’ve watched on this! Thank you so much for explaining not only the “how” but the “why”!
@handydadtv2 жыл бұрын
Thanks so much 😊
@franciscovillarreal1177 Жыл бұрын
Man I been a electrician 3 years going on 4. Let me tell you sir, Not a lot of people like to explain or teach for job security but man I love the way you explain your work. I’ve watched other videos as some are good you are damn good at teaching and explaining. Your calling was definitely a electrician but also a teacher/instructor 🤙🏽
@handydadtv Жыл бұрын
Would you believe I’m neither an electrician nor a teacher? My day job is an IT project manager. 😊 Thanks for the compliments. 👍🏻
@JeffMWar11 ай бұрын
Thanks for the exceptional explanation
@handydadtv11 ай бұрын
Glad it was helpful 👍🏻
@RapTalesRewind10 күн бұрын
I am just new to electrical so Im gonna watch this again and take notes. Thank you.
@handydadtv9 күн бұрын
Glad it was helpful 👍🏻
@yanniklabbee28514 ай бұрын
Excellent video, thank's for lighting me up,your time, patience and great explanations. My wife will not believe me when she'll come home and that the three way switch is working well. You should have see/heard me yesterday trying!!! 😇
@handydadtv4 ай бұрын
Glad it was helpful 👍🏻
@raza69687 ай бұрын
Hi Chris- Thank you so much for sharing this video it really helped me chance the entire fixture off your video.
@handydadtv7 ай бұрын
Glad it was helpful 👍🏻
@swaggerdo72317 күн бұрын
I have a setup exactly like your demonstrated. Wired as per your instructions, works perfectly. I have two kasa switches, yet without a separate neutral in the far box, I had to use one smart, one dumb switch. all connected to Alexa, another honey do task done.
@handydadtv7 күн бұрын
Glad it was helpful 👍🏻
@sarahhardy3828 Жыл бұрын
This is such a helpful video! Thank you!!!
@handydadtv Жыл бұрын
Glad it was helpful 👍🏻
@carlz77776 ай бұрын
You deserve ever positive comment!! Believe me, as I have watched a number of videos to try and find a solution. I have two 3-way switches in a 4-inch box in my garage (that we never use) that I want to replace with outlets and just control the lights with the switches inside the house. Maybe the solution is in this video and I just need a good night's sleep to help my head stop spinning long enough for it to register!
@handydadtv6 ай бұрын
Thanks 😊 I find diagrams helpful as well. This video may help you draw the solution: kzbin.info/www/bejne/l5LNqpuNpbpsnNE
@carlz77776 ай бұрын
@@handydadtv Thanks so much Chris! I fully agree as I have done exactly that when laying out our home network and TV with a bunch of other components. I'm confident that I will have to pigtail some wires to maintain the circuit for the lights and then just use the hot and neutral (which I have identified) for my outlets. Thanks for taking the time!
@felixgarcia8393 Жыл бұрын
Great, thank you for taking the time to help people understand. Very, very helpful info.
@handydadtv Жыл бұрын
Glad it was helpful 👍🏻
@noeponce46907 ай бұрын
You are awesome teaching and make me feel like I can do this. And I did, you help me be confident and comfortable doing electrical stuff around my house. Because of people like you I think more people are more confident doing things on their own (at least in my case). The only thing that I have to do is little more research is when you connected the second switch, you didn’t specify or show where the he wires go( like the white ones from the light and the power source) since I am not an electrician, I had to do a little digging. But overall awesome work and thank you so much for the videos that you make. God bless you.
@handydadtv7 ай бұрын
Glad you worked it out!
@seattlebest7910 ай бұрын
Great video. Can you add additional lights to the 3-way switch? Example, 2 lights for 3-way switch? Thanks
@handydadtv10 ай бұрын
Yes
@richardrecker57511 ай бұрын
Great instruction…thank you!
@handydadtv11 ай бұрын
Glad it was helpful 👍🏻
@jerrywillis18004 ай бұрын
Chris thank you for your time in explaining the ever confusing 3-way 👍. Unlike others I am not an electrician by no means of the word but you broke this down to even I understood the process. I am puting in 3 led ceiling lights and an exhaust fan in my bathroom and I am wanting to put them all on the same circuit and wire them with all on two 3-way switches. Can I run a 12/3 wire between the switches and then daisy chain the lights and exhaust fan with 12/2 wire? I am wanting to wire them with 3-way because I have 2 doors for the master bath
@handydadtv4 ай бұрын
First cardinal rule is to keep outlets and lighting on separate circuits. Otherwise your LED lights will flicker from the blow dryer, etc. Trust me. Don’t wire those lights from an outlet circuit. Yes, you can put all the lights on the 3-way circuit. Makes perfect sense. Personally, I would never wire the fan to always be on with the lights. I’d give it a separate switch near the shower. And I’d install a timer switch that has buttons for different times. Push the 15-minute button when you get in the shower so you can walk away and never forget to turn it off.
@jerrywillis18004 ай бұрын
@@handydadtv Chris thanks for the feedback much appreciated. Yeah I didnt think it would be too big of any issue putting the outlets on the same circuit because this is an older model house built in the 80's. However, after reading what you said and going back to find a solution I had to take out more drywall. This served to being a good thing due to the fact I found more electrical issues. To fix it I will have to rewire a few more fixtures so I will be able to put lights on one circuit and my outlets on another. Again thanks for letting me pick your brain and giving me a better solution Keep up the good work my friend
@handydadtv4 ай бұрын
@jerrywillis1800 Ah the 80s. I remember them well. No cell phones. No Internet. No HD flat screens.
@Talachachannel11 ай бұрын
Muchas gracias Ahora tienes un Nuevo subscriptor Gracias por compartir tu experiencia
@handydadtv11 ай бұрын
👍🏻
@satwantsingh198010 ай бұрын
I just installed a 3 way switch. Thanks to you
@handydadtv10 ай бұрын
Glad it was helpful 👍🏻
@edgararcega3046 Жыл бұрын
Are these the circuits typically used in stairways where the upstairs and down stairs switches control the same light?
@handydadtv Жыл бұрын
Yes and two entrances of big rooms.
@macsterguy2 жыл бұрын
Nice job. Best I’ve seen. Makes total sense to me 👍🏼
@handydadtv2 жыл бұрын
Thanks so much 😊
@chrisbanzali9971 Жыл бұрын
Great video and explanation! I currently have the same set-up in the 2nd scenario, except my switches power an outlet. How can I change this to a constant hot outlet and then use switches for a light source?
@handydadtv Жыл бұрын
Think it through. I think you’d need to abandon the 3-way circuit.
@Compwib9 ай бұрын
Thanks for teaching about how travellers wires works. While troubleshooting i found the wires were going from the back of switch where one has release them white , red and black another black which is main or hot wire was passing through screw. Can we put red and white on the travel golden screws . The third black wire will from the back of switch position near release hole
@handydadtv9 ай бұрын
Hard to follow. You can use white as a traveler, but wrap a piece of tape at both ends to indicate that it’s hot instead of neutral.
@MelodieEdmund Жыл бұрын
Hi there, great video. You showed the setup for two different ways when kight fixture is last in line and when light fixture is in middle. How do you know which way yours is setup?
@handydadtv Жыл бұрын
Thanks! You need to open everything up and use a non-contact voltage tester to find the power source.
@MelodieEdmund Жыл бұрын
@HandyDadTV Thank you. Do you have a video just like this one, but with smart light 3way switches?
@handydadtv Жыл бұрын
Not yet, but in the works.
@johncolon244 Жыл бұрын
Thank you for you tutorial.
@handydadtv Жыл бұрын
My pleasure
@jasonlopez7480 Жыл бұрын
I came across your videos and love them. I do have an issue with my ceiling fan and can lights in my living room. I have two switches just in the video and both of them control the fan and lights. We can’t just turn the lights off and leave the fan on and vice versa. Do you have any ideas what it could be? I’ve racked my brain so many times trying to figure this out and I’m a do it myself kinda of guy.
@handydadtv Жыл бұрын
I don’t know how old your house is, but odds are, your 3-way switches originally powered a light fixture in the middle of the ceiling. Then somebody replaced the light with a ceiling fan. Then somebody decided they needed more light so they wire the can lights from the box in the ceiling because that was the easiest thing to do. How close am I? At this point, it makes sense for the switches to control the lights but I’d rather see the fan have constant power so you can just use the pull chains or a remote to control it. That could be easy or hard depending on how the 3-way circuit is wired. If power comes into the ceiling box and then loops through the switches, you can easily change the fan to have constant power. If the power comes into a switch, flows to the other, then to the fan box, you’ll need to find a new power source for the fan. You need to open the fan box and use a voltage tester to figure this out.
@jasonlopez7480 Жыл бұрын
@@handydadtv My house was built in 1972 but I think you’re spot on with my situation. The only issue is I have a vaulted ceiling and in the center the fan hangs down but it’s 13’ from the center of the room. So checking on the fan to see how it’s wired is kinda out of the question. Can’t I pull out both light switches and see if there’s more than one set of wires running to the switches? I would think that the can lights are on one wire anyways and spit between the two switches.
@handydadtv Жыл бұрын
@jasonlopez7480 Sure you can do look in the switches, but I can pretty much guarantee you’re not going to be happy. With a vaulted ceiling, I highly doubt the electrician ran power to the fan first. I’d bet it comes into one of the switches first.
@jasonlopez7480 Жыл бұрын
@@handydadtv That sucks.. I took the can light bulbs out so we can run the fan but I know it’s not safe for that. So I’m pretty much screwed unless I rewire the entire thing.
@handydadtv Жыл бұрын
@jasonlopez7480 I had NO fan box in my great room with a vaulted ceiling. Even I hired an electrician to do that install! kzbin.info/www/bejne/jHnWYot4mdN2rtU
@jramos2010 күн бұрын
This is a great video. But I was trying to install the Kasa HS210 v3 switch and the white/neutral wire and the ground are already ore connected to the switch still leaving 2 slots for travelers and 1 for line/load. Can you explain if I can still do this since the white wire is already prep connected into the switch
@handydadtv10 күн бұрын
Whenever a white wire is connected to a switch, it is NOT a neutral. You need to follow the wiring diagram that came with the switch. Coincidentally, I have an HS210 waiting to be installed for a video. Hopefully sometime in January.
@jramos2010 күн бұрын
@handydadtv thanks. This is a newly created switch so the second switch is a dead end so only 4 wires come out of it. That's why I'm confused on what to do.
@laifsalvadori99526 ай бұрын
Now can you do one with a motion sensor on one side for stain wells? Leviton does one but only for single pole. One question I want to know is if the distance it too long for just one sensor then does my second sensor need to be a companion sensor or a slave sensor or just two of the same? Thank you for teaching this subject.
@handydadtv6 ай бұрын
I don’t know of any 3-way motion sensor switches. I’d opt to use home automation instead.
@lgrullon8546 ай бұрын
I agree, I am still trying to understand 3-way after more than 2 years trying to figure it out on my own...I still have my stairs light only powering on one side....need to take time to fix it and make it work both, upstairs and downstairs 🙂
@handydadtv6 ай бұрын
This may also be helpful kzbin.info/www/bejne/l5LNqpuNpbpsnNE
@RobertConnollyOATS4 ай бұрын
Just curious if I add an power outlet in the center instead of a light would it wire differently?
@handydadtv4 ай бұрын
No, it’s the same for outlets.
@jordanmccugh883811 ай бұрын
Great video! I am looking for wiring diagram that can help me troubleshoot 3-way circuit. Actually this might be considered a 4-way circuit, I'm not sure. I have two switches controlling two lights. One switch and one light at the bottom of the stairs and the other light with the other switch at the top of the stairs. The switches control the lights in the same way you described in this video, and the lights turn off and on together as if they were one light, the lights turn on together and turn off together. Recently the light fixture at the bottom of the stairs stopped working, tried several bulbs, no luck. The switch at the bottom of the stairs still works, it can still turn the light at the top on and off. Anyways I just wanted to find some sort of a relevant diagram before I did anything to it. Any advice?
@handydadtv11 ай бұрын
You can use Google Images to get diagrams, but chances are your electrician deviated from the standard method to use the least amount of wire. When you drop the light, you may see a lot of other wires. Don’t waste your time trying to figure it out; just do a direct replacement using the same wires from the original light.
@jordanmccugh883811 ай бұрын
Thank you! I appreciate the input. Im not in a hurry to work on it, just a project near the bottom of the list. It has been like this for a while now.
@genevievecadet49563 күн бұрын
Do you have one where one of the 3 way switch has a toggle with a regular switch. I have an existing light in my hallway but I am adding two sconce light. I am using a toggle switch opposing to having to change to a 2 gang box.
@handydadtv3 күн бұрын
I have one with a double toggle switch (kzbin.info/www/bejne/e4nIp6ywrbV_hLc) but you can also buy a double 3-way switch.
@genevievecadet49563 күн бұрын
@ thank you
@umiskan58197 ай бұрын
What do you do with the white wire comming from the light to the first switch box( in the first senario)! Thank you!
@handydadtv7 ай бұрын
Sorry it wasn’t clear. The two white wires are neutrals; they get connected together.
@umiskan58197 ай бұрын
@@handydadtv Got it, thank you!
@CGIConvMode4 ай бұрын
Great video. You should turn on super thanks.
@handydadtv4 ай бұрын
Thanks so much
@andrewstradley8365 Жыл бұрын
I like the second way it’s much more simple for a guy coming from commercial/industrial.
@handydadtv Жыл бұрын
It’s more common as well
@jeffdieli889810 ай бұрын
Hi there, great tutorial videos! I have 3 switches that control one light but have an issue when turning off as when i turn off one switch the light will turn off momentarily but will turn back on which I would need to go to the other switch and flip that one off to keep the light off. Its a real head scratcher and cant seem to figure it out, any suggestions?
@handydadtv10 ай бұрын
Sounds like a defective switch.
@angelocontreras86652 жыл бұрын
Thanks for the explanation. It was very helpful. My question is how would I take power from a 3 way to add a separate light and switch?
@handydadtv2 жыл бұрын
You could only do that from the box where power comes into the circuit. You need to identify the always hot wire. Then follow this kzbin.info/www/bejne/roC9p2Rtd7WHkKM
@clava44189 ай бұрын
What did you do with the neutral from the power source? I am currently trying to create a new 3-way, but the only wires going to my switch are a hot and one to the light.
@handydadtv9 ай бұрын
This may help: kzbin.info/www/bejne/baTLgIeXeapnoJY
@bobhuston3894 Жыл бұрын
Hello! I have a laundry room that I enter from a garage. There are two three-way switches, and the light worked great. I thought a motion sensing automatic switch would be a great idea, so I put it in place of one of the switches. I only worked inside that one box. However, now that its all done, the sensing switch only works if the switch I didn't work on is in one position. For the life of me, I can't seem to figure which wire is wrong inside the box with the sensing switch. Any ideas would be greatly appreciated. Thanks
@handydadtv Жыл бұрын
You need to remove the other switch so the motion sensor has constant power.
@bobhuston3894 Жыл бұрын
But it's a three way sensor switch. It's a Lutron Maestro, with three way option.
@bobhuston3894 Жыл бұрын
And what would I do with those wires, in that unused box, if I eliminated it.
@handydadtv Жыл бұрын
@bobhuston3894 Ok in that case, it sounds like you reversed the line with one of the travelers.
@mattwalters2590 Жыл бұрын
Let’s say you are adding in a hanging light above a kitchen island and there happens to be a 3 way switch for the kitchen lights can you designate one of those switches to the new light ?
@handydadtv Жыл бұрын
Not without rewiring the circuit. I’d leave the 3-way circuit alone and add a switch for the new light. Not easy, but that’s the best long term solution.
@samjaga71684 ай бұрын
You explained it best
@handydadtv4 ай бұрын
Thanks so much 😊
@dale36687 ай бұрын
How do you add a new light, switch, and then receptacle (in that order), when the power source is in the light at the top of the wall from attic? Is there a video with this scenario?
@handydadtv7 ай бұрын
No video for that specific situation, but these will help: kzbin.info/www/bejne/Y4jYl5WpqcipiNk kzbin.info/www/bejne/roC9p2Rtd7WHkKM kzbin.info/www/bejne/rYO2mJijft2Uo7c
@ld825811 ай бұрын
Question: I have an existing flood light on a switch. I want to change fixture to a motion flood light. Do I have to have the switch on all the time? Or is there a way to tap into the hot wire and allow the new motion flood light to be active and at the same time be able to turn on with the switch on demand. Not sure if that is possible. Sue
@handydadtv11 ай бұрын
The best practice is to simply leave the switch on all the time. Most motion floodlights have a manual override so you can turn it on by toggling the switch off and on.
@ecarpentry Жыл бұрын
Nice Video.. My issue is I have a three way coming into the light from a switch thats hot. and I need to put another light switch on the other wall coming from that light box. Any idea I've searched all over and cant find any video of a three wire coming into the light switch from another switch. Any help from someone would be greatfully appreciated.
@handydadtv Жыл бұрын
Do you mean the light will be wired *in between* the two switches?
@ecarpentry Жыл бұрын
Yes I shoud of said its a three wire with a ground , whats strange is they have a single blue wire hooked to the first switch on the bottom screw to the right, I did test the black and white and it does work off the first switch but I'm left with the red and this blue wire. I need to run a three wire to another switch from that light. After looking more into it just now the three wire is hooked up to the first switch and there is another wire looks like the hot, So I have a switch the red wire is hooked to the left side top, the black from the three wire is hooked to the top right and the hot and this blue wire is hooked to the bottom together, as I said this one single blue wire is running to the light. its an older house built in 1970 @@handydadtv
@ecarpentry Жыл бұрын
Somebody else was messing with it and never took a picture how it was wired when he took the light down because it was cracked. if so I wouldnt be posting this. he said there was a white wire not hooked up it was just in the box with no wire nut.🤨
@estishomeservices22 күн бұрын
In the scenario with the power and light in the same box, what do you do with the white wire from the light, you don't tell where that one goes.
@handydadtv22 күн бұрын
That’s for the light to have a neutral, which is always required to complete the circuit.
@nickpanhead7209 Жыл бұрын
I watch this video you sent me, but I'm still a little confused, my circuit breaker panel is downstairs. Making me believe that the source of the power is going to the lower switch, then the travel wires brings it up to the top of the stairs switch. That's the one I'm tapping off of to add that outlet. Is there any way to make that outlet hot all the time. Not shut off when either upper or lower switch is turned on for over head light
@handydadtv Жыл бұрын
You could abandon the traveler and change them to smart switches. That’s the only way to have a constant hot at the top switch.
@nickpanhead7209 Жыл бұрын
@@handydadtv I appreciate you getting back to me, but I'll probably just leave it the way it is. I'm fine with it, my main reason to put the outlet in was just to put a night light there, to light up the first couple of steps at the top of the landing. Then once I turn the switch on to put over head light on, I really don't need it anymore, because the the whole stairway is lit up. But thank you again for your quick response
@aluminummovie69735 ай бұрын
Hi love the content! Need help bad. My daughter would like to replace a light in the kitchen but I can’t figure out the sequences of wires. 3 ground wires 3 black ( one is hot) 1 red 3 white I hooked them light to them lights on but can’t shut it off. The other two lights don’t come on. Or two lights come on.and switch works. But the light I’m working on is off.
@handydadtv5 ай бұрын
When replacing a fixture, always reconnect the new light to the same wires as the old one. I’m assuming she didn’t mark those wires and she doesn’t remember how it was wired. Glad to hear you have a voltage tester! If you connect all the black wires, is the red hot only when the switch is on? If so, connect that to the black wire on the light.
@joegalligher17702 ай бұрын
When using the white for hot what's used for neutral?
@handydadtv2 ай бұрын
In that scenario, there won’t be a neutral in that switch box.
@vincentperry4765 Жыл бұрын
I noticed that on the switches the red and black wires were transposed at the top. Would it make a difference if, say both black were on the left side?
@handydadtv Жыл бұрын
The brass screws are for the travelers and they are reversible.
@sure71055 Жыл бұрын
Do you have a video showing how to take one light and make it two on the same switch? I would like to take my one bathroom light that's in the center and create two side sconces instead.
@handydadtv Жыл бұрын
No specific video on adding lights (yet) but they just get added in parallel to the original light: white to white and black to black.
@brianb336 Жыл бұрын
thx buddy you are awesome.
@handydadtv Жыл бұрын
Thanks so much 😊
@jaimeav66342 жыл бұрын
Good video
@handydadtv2 жыл бұрын
Thanks 😊
@Concerned_Citizen11111 ай бұрын
I was always taught the second way you did it.
@handydadtv11 ай бұрын
Thanks
@carloscolipi56536 ай бұрын
How can you add and extra light to that 3 ways switch?
@carloscolipi56536 ай бұрын
Great video by the way 👍🏼
@handydadtv6 ай бұрын
It’s easier to wire another light from the existing light.
@thoughtsfromaidiot59289 ай бұрын
So do you need 3 wire from the breaker?
@handydadtv9 ай бұрын
No
@samsen39652 жыл бұрын
In a previously installed 3-way switch house, What is the easiest way to find which of the two is the one that is first connected to the circuit? I need this to replace only one with the WiFi 3-way, instead of changing both as I am told it will work and save me an extra wifi socket that way.
@handydadtv Жыл бұрын
Pull them out and inspect the wires. Find the hot leg and the one that goes to the light. Then adapt it for your new switch. They’re all different.
@MoeinEsther8 ай бұрын
just perfect . TNX
@handydadtv8 ай бұрын
Glad it was helpful 👍🏻
@VisualQC75 Жыл бұрын
Need help, so I have the 3 way setting. I'm replacing one switch with a combo (switch + outlet). In that switch, I have 2 traveller wires. that will power the light depending on the switch position. And 1 cable that brings the power to the light bulb. I installed the switch + combo. The 3 ways work normally but I don't know how to bring power to the outlet. i want them to be separated. so I need power at all times in the outlet. suggestions?
@handydadtv Жыл бұрын
You can only use that switch/outlet combo in the switchbox where you have constant power.
@sambathbunkh11 ай бұрын
Best video sharing
@handydadtv11 ай бұрын
Thanks so much 😊
@joshdifilippo7176 ай бұрын
I have a light in a hallway wired just like your intro diagram and I assumed I could add multiple fixtures from the original light and that isn’t working
@handydadtv6 ай бұрын
Ignore the switches and how the circuit is wired. You can always add lights by wiring them to the same hot and neutral on an existing light.
@MelodieEdmund Жыл бұрын
Hi again! I know you are doing a video about this, but I need help. I have a 3-way smart switch. Specifically, the Kasa 3way wifi smart switch and every single diagram I see, the assumption is the power goes from 1st switch to 2nd switch then to the light fixture. My switches are run differently, my power runs to 1st switch then to the light fixture and then to 2nd switch. None of the examples show this type of setup, and I am wondering if 3way smart switches only work when power goes to switch 1 then switch 2 then fixture? And not any other way.
@handydadtv Жыл бұрын
The issue in your scenario is the second switch doesn’t have a neutral. I believe Kasa switches always require a neutral.
@MelodieEdmund Жыл бұрын
@@handydadtv Hi there, thanks for responding. We have neutrals in both locations. All our switch boxes have neutrals
@handydadtv Жыл бұрын
If the second 3-way switch has the white wire connected to it, that’s NOT a neutral.
@MelodieEdmund Жыл бұрын
Ok sorry, the box has neutral wire. The main switch for the 3way is in a two gang box (main switch has a neutral required) the satellite or companion switch is in a 4 gang box, but the satellite switch requires traveler 2 and load on one screw, traveler 1 on 2nd screw and ground wire that needs to be tied into other ground wires.
@handydadtv Жыл бұрын
Wow. I think I got it but it’s really hard to grasp. I might have to buy that kit to play with it. One thing to note, however, is that you’re talking about “borrowing” the neutral that didn’t originate with your light. You can’t do that if it’s on a different circuit because it creates a shock hazard when working on either circuit unless both are off.
@myrickgordon8046 Жыл бұрын
I have a switch box with two yellow and a red wire connected to the switch I am adding recessed lights how do I connect the new white and black wire to that switch for correct operation?
@handydadtv Жыл бұрын
That’s non-standard wiring. Please call an electrician.
@hakmok55798 ай бұрын
You can fix pilot lamp for all switches, we can know the light on if the switches in different area
@handydadtv8 ай бұрын
Not sure that’s possible without smart switches.
@jackh993419 күн бұрын
I have 2 lights in my garage that are controlled by a switch going out into the garage can i just cut in-between the 2 lights and add another light
@handydadtv18 күн бұрын
Yes you can add another light to an existing one.
@rmodalitad47495 ай бұрын
What if each switch box has a connection to a light. Switch box 1 has 14-2 to a light, and switch box 2 has 14-2 to a light. And 14-3 goes from sw box 1 to sw box 2. Also, the hot 14-2 comes into sw box 1. How do you wire 3-way switches so either switch can still control both lights?
@handydadtv4 ай бұрын
If power comes into box 1, the other 14/2 probably goes elsewhere down the circuit, not to the light.
@GailUrge-vq6qn3 ай бұрын
three way switches are all the same; they work as a variable switch; a first switch(line switch) receives current at the separate end terminal; the second switch(load switch) feeds current from its separate end terminal over to the light; "HandyDadTV" wasn't at all handy explaining the necessity and functionality of the two Hot wires needed between the switches - "travel wires", "travelers" or "pared wires"
@01redcrew2 жыл бұрын
Could you make a video on putting a timer on a 3 way switch?
@handydadtv2 жыл бұрын
Timer, no. But I’ll be doing a smart switch soon that supposedly works with 3-way circuits.
@spotlightnutrient6618 Жыл бұрын
HELP please hello is there any way you can explain to me what to do if the light will not come on. I removed the switch and light fixture and checked the wiring and everything looks correct. They were connected to a single pole switch I went and got 3-way switches and rewired. Am I doing something wrong. Do I have to go in the ceiling to check... I know power runs from receptacle outlet to switch from switch to light fixture and the light fixture will not come on. Not sure what to do HELP please
@handydadtv Жыл бұрын
It’s impossible to say. You need to get a voltage tester and figure it out. Sorry.
@jimspy1001 Жыл бұрын
Thanks to you, I'm understanding this concept. Now...I don't suppose you could do a video on hooking up a 4-way, using all Insteon switches? I have what has to be the most confusing situation of all time. Three switches all operating the fluorescents in my garage, and two of them are ganged together with switches that control other loads. Worst of all, I detect hot on TWO of the fluorescent switches - not one, but TWO. And the kicker is, I once had this all wired correctly, but I had to replace a bad switch, and it all went south. Actually, never mind. I need to bite the bullet and hire an electrician!
@handydadtv Жыл бұрын
The 4-way is in my queue but I know it won’t get many views.
@jimspy1001 Жыл бұрын
@@handydadtv Well, you can count on mine! ...if that's any solace...
@LloydChapman-h9o Жыл бұрын
explain diffrent switches identifiying what is needed
@handydadtv Жыл бұрын
I don’t understand
@kennethlewsader8247 ай бұрын
My problem is everything is hooked up. I took down a ligh. I have central air. The room is 6 × 9. It get hot with use of the oven or washing the dishes. No room for a dish washer. I installed a ceiling fan with a light. The light switch doesn't turn on the light. When you pull on the fan the light barely comes on & wouldn't stay on. The fan works well. One switch is in the kitchen. The other one is on the wall going to the basement or a side door going outside or to Come in. The 1st switch has a black wire on every screw. One goes towards the other switch in the kitchen. The other 2 goes to a different switch for the landing light & the other one turn on the basement light. The big oval light I took down connect black wires together with what would call lead wires then the white wires were done the sane. That's how did it too what do I need to do to fix this. Plus the 2 nd switch isn't a three way just 2 screw on the right side & green ground screw on the left side. Thanks for you awesome video & explaining it. I am just so lost. You hep would be greatly appreciated!!
@handydadtv7 ай бұрын
I’m lost too.
@GailUrge-vq6qn3 ай бұрын
It sounds like it wasn't wired correctly for a 3-way switch setup. Get a test light or a meter and troubleshoot it or call an electrician.
@bayandamabuza6587 Жыл бұрын
That's was one of my Physics 201 practical in Year 2
@handydadtv Жыл бұрын
Good job
@patobrien70099 ай бұрын
I have a confusing problem with a 3 way circuit.when the light is on it can be turned off from either switch, when it is off it can only be turned on by the switch it was turned on with. Help!
@handydadtv9 ай бұрын
It sounds like it wasn’t wired correctly for a 3-way circuit. Get a meter and troubleshoot it, or call an electrician.
@johncolon244 Жыл бұрын
How dou know wish is 15amp and wish 12 amp. What happen if you put the Wrong amp in the wrong Cable
@handydadtv Жыл бұрын
Find the circuit breaker and look at the number on it.
@kennethlewsader8247 ай бұрын
I am sorry. On the kitchen ceiling was a bid oval light. So I got a ceiling fan with a light on it. I took it down the bottom had two black & to white . One on each side they were wire ca🎉
@kennethlewsader8247 ай бұрын
Sorry cap twisted but a lead wire was added to be connected to the wires in the ceiling. So I did the exact same set up! The only thing I did that they didn't. They used one nail to hang the plastic outlet box. I got a metal one took a 9" lag bolt & 6 " one too. The 9" went into te rafters & the other one went sidewalk into a board.. it was a moving fan & light too!! Didn't want anything to happen.. I am sure the wires aren't connected to the Proper one's ! Is there a way I could send pictures of the outlet boxes & the bottom of the light I removed & the Wires hanging from the ceiling. I rent the house. I took down two ceiling lights up stairs & put a fan & lights kit up no problem whatsoever! Thec switch the wall going down or out has agreed way switch . the one in the kitchen isn't a three way.
@handydadtv7 ай бұрын
@kennethlewsader824 I can’t follow. Please call an electrician, especially in a rental.
@bradvuong Жыл бұрын
I have a 3-way switch setup connected by a 12/2, not 12/3, wire. The neutral in one box is capped and the neutral in the other box is also capped. But, somehow the 3-way switch works.
@handydadtv Жыл бұрын
Sounds like they used the black wire from the second cable as a red. That’s why you don’t need the extra neutral.
@bradvuong Жыл бұрын
@@handydadtv I'm trying to install a smart light switch that requires a neutral wire. Should I just go ahead and cap off the neutral wire from the new switch since the neutral wire in the box is not being used?
@handydadtv Жыл бұрын
It’s impossible to answer in a comment because wiring has many variations. You can watch videos to learn the basics, but you need to develop the skill to troubleshoot and figure things out. Don’t hesitate to contact an electrician for a complex situation.
@stevenewton70283 ай бұрын
There are 3 switches in my bedroom. Each switch can turn on or off the ligh bulb. (Only 1 light bulb) 1 switch doesn't work. I bought a Legrand switch to replace it. There are only 2 cables coming out of the wall, one blue (N) one white (L). The new switch works OK but now the other two do not. Can anybody help please?
@handydadtv3 ай бұрын
I have no idea what kind of circuit that is. Three switches means it’s a 4-way circuit, but you should have more than 2 wires.
@samsen39652 жыл бұрын
1:09 14G wire = 15 Amp circuit 12G wire = 20 Amp
@handydadtv Жыл бұрын
Yes
@pearlperlitavenegas2023 Жыл бұрын
It's ok to use 12 wire on a 15amp circuit?
@handydadtv Жыл бұрын
Yes, you can always exceed the minimum specs.
@pearlperlitavenegas2023 Жыл бұрын
@@handydadtv Thanks your videos are IMMENSELY HELPFUL
@kennethlewsader8247 ай бұрын
I do have a extra 3 way switch. I don't have any extra wires in the back of outlet Box.
I have 6 different pairs of switches like this in my house. 1 at either end of mud room controlling 1 light, 1at btm of stairs on main and its pair at top of stairs at 2nd floor for 1 stair light,, 1at top and base of basement stairs for 1 stair light, one in same box at base of basement stairs and its match on other side of room for celing lights, 1 on either sided of my kitchen contolling kitchen ceiling lights, and finally 1 at front door and one by kitchen that contold the entry hall. The Problem is ALL OF THEM work out of sync with its pair. Neither switch of each pair can be in the same position at the same time. If light is on, one is up and one is down. if light is off, one swith is up and one is down. How can I fix this??? It drives me N-U-T-S
@handydadtv Жыл бұрын
Turn one of them over.
@thekylefrick Жыл бұрын
@@handydadtv You're telling me that all of these switches are just installed upside down??? Or is there really a wiring miscue? If they are just upside down, is it best to always have the grounding screw at bottom? Basically, which one is best to flip? Funny thing is, I was joking with my wife a few days ago that I should just flip the switches upside down. She laughed at me. HA! Whos laughing now?
@handydadtv Жыл бұрын
3-way switches have no “top” or “bottom”. It doesn’t matter which way the ground screw points. Just turn one over, change no wiring, and you’ll immediately sleep better at night.
@jasonmorgan281710 ай бұрын
You never said where to put the white wire from the power wire.
@handydadtv10 ай бұрын
The white wire is neutral and just passes through to the light.
@Mike-01234Ай бұрын
I'm not a fan of relabeling conductors I know it's legal in a NM cabling. Black and red are suppose to be the traveler wires.
@handydadtvАй бұрын
Agree
@eliascruz9757 Жыл бұрын
Good for it.. you are so sweet
@handydadtv Жыл бұрын
Thanks 😊
@eliascruz9757 Жыл бұрын
@@handydadtv thank you for your help you have self my problem. You have great communication skills. Many Blessings
@anthonyparker94298 ай бұрын
Why skip. Walk everything through it make it easier.
@handydadtv8 ай бұрын
Glad it was helpful 👍🏻
@BruceHill-rm4vw2 жыл бұрын
Code violation the white wire can no longer be used in a switch loop per the NEC.
@handydadtv2 жыл бұрын
Which method was wrong? What should be done differently?
@BruceHill-rm4vw2 жыл бұрын
@@handydadtv The first one, the white conductor is the grounded conductor, which must be present in all switch boxes ( if used or not). You would have to use 14/4, or 12/4 to feed and return from the same box. One of your other videos covered the white wire being in the switch box is correct this is now a code requirement, as you stated for future use.
@handydadtv2 жыл бұрын
Wow thanks for pointing this out!
@RJScott2 жыл бұрын
@@handydadtv Based on @BruceHill I should just use your second example, which actually seems a bit easier to do?
@handydadtv2 жыл бұрын
Yes, if you’re doing a new installation, use the second method.
@clarenceghammjr1326 Жыл бұрын
I’m doing a four way, both three ways work if four way in one position, but nothing if you flip it😂
@handydadtv Жыл бұрын
That video is on my to-do list.
@bigdaddy3181 Жыл бұрын
I can't make it work. There is either power at all times at the second switch or no power at the second switch.
@handydadtv Жыл бұрын
Keep trying. You’ll get it.
@bigdaddy3181 Жыл бұрын
@handydadtv I've stopped at each step on the video and have mirrored each step. The only difference is my switch is a paddle switch.
@bigdaddy3181 Жыл бұрын
And the brass screws are on opposite ends with the black screw next to the brass .
@bigdaddy3181 Жыл бұрын
Well I figured it out. I guess you have to have the light fixtures installed Works
@handydadtv Жыл бұрын
@bigdaddy3181 Are you 100% sure it’s a 3-way switch? It should have 4 screws, including ground.
@jensschroder82144 ай бұрын
Why is this a 3-way switch? 1st way: Common contact connected to contact A 2nd way: Common contact connected to contact B Where is the 3rd way?
@handydadtv4 ай бұрын
I believe they call it a 3-way switch because it requires three conductors.
@JesseBusby-g7s4 ай бұрын
Just used 12/2 with a seperate neutral, didnt have 12/3
@handydadtv4 ай бұрын
Make sure to mark the non-neutral white wire so it’s redesigned as a hot.
@tibby24Ай бұрын
Ok, now I’m confused 😂
@handydadtvАй бұрын
3-ways are confusing.
@dingding86622 жыл бұрын
Soo confusing
@handydadtv2 жыл бұрын
I tried 🤷🏻♂️
@surferdude6422 жыл бұрын
Another way is to connect your travelers on your 14/3 to the gold screws on the switches, red and black to the respective locations on each switch. The black from the power (14/2) to the common (black screw). The black from the light (14/2) to the common on the other switch. The white wires remain neutral and will be connected together in each switch box. The white wires (neutral) are now connected directly from the power to the light and no need to make a white wire reconfigured as hot. This will also satisfy the code requirement that a neutral wire remains available in at least one box for the potential future upgrade to wifi switch/dimmer.
Quick question . I’m replacing a pre wired dimmer switch with a regular toggle switch . The pre wired dimmer has 2 red and 1 black . There is only 1 line coming into the box which contains black, red, white . The switch is wired black to black , red to red and red to white .? I can’t figure it out . Of course the switch doesn’t work but I’m not sure if the switch is bad or just the wiring is bad .. any help would be great
@handydadtv Жыл бұрын
So the dimmer died and that’s why you’re replacing it? Sounds like a 3-way dimmer. You need a voltage tester to figure out where each wire goes. If you can’t, please call a handyman or electrician.