No video

How to wire a Blauberg Bathroom Extractor Fan with timer and humidity sensor to a lighting circuit

  Рет қаралды 6,680

Blauberg UK

Blauberg UK

10 ай бұрын

A step-by-step guide on how to correctly wire a bathroom extractor fan to your home lighting circuit.
The video importantly shows how to wire the live, switch live, and neutral electrical connections, from the fan, through the isolator switch. The wiring continues up to the lighting ceiling rose, on to the fan and pull cord switch.
The video also explains how to correctly set up Blauberg fans with run on timer and humidity sensor control options.
** THIS VIDEO IS FOR ENTERTAINMENT & INFORMATION PURPOSES ONLY - IF YOU CHOOSE TO RECREATE ANYTHING SHOWN IN THIS VIDEO YOU DO SO AT OUR OWN RISK **
Calm Fan Facts
German Blauberg Motor
Mixed flow impeller design
Fitted with anti-back draught shutter
Wall or ceiling mounting
IP45 rated for bathroom zones 1&2
Available in 4 colours
The Blauberg Calm Fan Is perfect for any bathroom or wetroom and can be mounted in zones 1 and 2.
Extractor fans designed for use in zones 1 and 2 must be at least IPX4 or IPX5, where water jets are likely to be used for cleaning purposes. A 30mA RCD must also be provided to the electrical circuit.

Пікірлер: 8
@josejoselete6156
@josejoselete6156 4 ай бұрын
The fans in our toilets had timing control and matches your video as regards wiring etc. however one of the units needs to be replaced The new fan I bought blauberg line100 slim has only 2 wire connectors. What should I do should I return it? What model should I go for.
@blauberguk
@blauberguk 3 ай бұрын
Hi You would need either www.blauberg.co.uk/100mm-4-blauberg-line-powerful-slimline-extractor-fan-bathroom-kitchen-wet-shower-room-run-on-timer or www.blauberg.co.uk/blauberg-calm-low-noise-energy-efficient-bathroom-extractor-fan-100mm For the Calm Fan you will need to select the timer option. This Video relates to the Calm Fan and can be put in both zones 1 and 2
@TonyMontana-os8ri
@TonyMontana-os8ri 10 ай бұрын
Can I install fan separate? I take shower during the day time and no need to light to be on. Instead of light switch I would use fan isolator as a fan pulling switch.
@blauberguk
@blauberguk 8 ай бұрын
There is a version that can just be operated by a switch/pullcord, for example the Calm S range. Or if they want to run it through an isolator switch, the basic Calm range. Take a look at www.blauberg.co.uk.
@harveylinney
@harveylinney 4 ай бұрын
Mine was ceiling mounted. Had to remove the humidity sensor. Not great for ceiling installation.
@blauberguk
@blauberguk 3 ай бұрын
This may be due to the installation. It's best not to have the ducting going vertical. it's best to have at least 2 x 90 degree bends and a drainage trap to stop condensation running back into the fan
@nimit2535
@nimit2535 10 ай бұрын
What happens if an isolator switch is not applied for the fan and the fan and light wiring has been put together with one switch? Can this cause safety issues?
@blauberguk
@blauberguk 8 ай бұрын
Fans must be installed with the correct isolators. if the required isolators for the fan are not installed, it is recommended to contact a qualified electrician for installation.
Joker can't swim!#joker #shorts
00:46
Untitled Joker
Рет қаралды 37 МЛН
女孩妒忌小丑女? #小丑#shorts
00:34
好人小丑
Рет қаралды 10 МЛН
黑天使遇到什么了?#short #angel #clown
00:34
Super Beauty team
Рет қаралды 37 МЛН
Lighting Circuits Part 1
24:18
John Ward
Рет қаралды 1,5 МЛН
How to connect up 1-way and 2-way lighting with a fan
18:52
Pure Electrical Training - by Adrian Davey
Рет қаралды 2,6 М.
Wiring a Blauberg Turbo-E Timer fan
1:41
Blauberg UK
Рет қаралды 43 М.