How to Wire an Extractor Fan or a Second Light From a Ceiling Rose and Pendant

  Рет қаралды 70,500

GSH Electrical

GSH Electrical

Күн бұрын

How to add a 3 core and CPC cable (supply) from a light to feed a bathroom extractor fan or take the supply and switch wire to another light. In this video we look at the layout of a ceiling rose and its connections - loop, neutral and switching line and how best to lay them out the new 3 core cable conductors. At college we often have only 2 twin and CPC (twin and earth) cables at the lighting points during training but often in the real world this would be 3 cables. With 3 cables already installed within a ceiling rose it can look full but you can still add cables to it. The connections in the ceiling rose are for the 3 plate method of wiring a lighting point explained in this video.
🔔 Subscribe for more free electrical training videos kzbin.info?s...
== 🕐 Time Stamps - Cut to the action 🕕 ==
00:00 - Wiring to an extractor fan
00:23 - 2 lights coming on at the same time
01:08 - 3 core and CPC cable
01:58 - Black or grey as neutral?
03:04 - Connecting the CPCs
03:36 - Screw on the floor is a screw I will see no more
03:52 - Connecting our grey neutral
05:00 Connecting our line
05:36 - Connecting our black switch line
06:25 - Finished connections
Videos are training aids for City and Guilds (C and G) and EAL courses Level 1, 2, 3 plus AM2, AM2S and AM2E.
You can follow me day by day on Facebook, Instagram, Twitter and TikTok lookout for "GSH Electrical”.
▶️ FACEBOOK / gshelectrical
▶️ INSTAGRAM / brihzmraygdtmjmdb9lunq...
▶️ TWITTER / gsh_electrical
▶️ TikTok vm.tiktok.com/ZMRBLFdhe/
#GSHElectrical #Electricaltrainingvideos #wiring #electricalwiring #howtowire

Пікірлер: 52
@awladali8149
@awladali8149 3 ай бұрын
You are extremely good tutor, keep up the good work. Thank you.
@AfricanSouthernCross
@AfricanSouthernCross Жыл бұрын
A master at his job !
@Bari_Khan_CEng_CMarEng
@Bari_Khan_CEng_CMarEng 11 ай бұрын
Great guidance and tuition, much appreciated
@GSHElectrical
@GSHElectrical 9 ай бұрын
Thanks
@jameslawrie3082
@jameslawrie3082 10 ай бұрын
These videos are brilliant.
@GSHElectrical
@GSHElectrical 9 ай бұрын
Thanks 👍🏻
@stephenguckel9329
@stephenguckel9329 6 ай бұрын
Well that helped me a lot. Thanks...😊👍
@sergiofernandez3725
@sergiofernandez3725 Жыл бұрын
Good stuff Gaz
@GSHElectrical
@GSHElectrical Жыл бұрын
Thanks 👍🏻
@johnwaby4321
@johnwaby4321 Жыл бұрын
I always fit fuse protection now to extract fans
@Dog-whisperer7494
@Dog-whisperer7494 Жыл бұрын
Excellent demonstration Gaz , but I have to bust your chops on one minor point, you put the earth in a separate terminal hole from the existing two earths you should have doubled the end over you the so called rule if a a single conductor is terminated on its own double the end over . Fantastic video as always GAz👍
@GSHElectrical
@GSHElectrical Жыл бұрын
If you have watched the series I talk about when to double over and the reason for it and when I don’t
@Dog-whisperer7494
@Dog-whisperer7494 Жыл бұрын
@@GSHElectrical dose it matter if you double the end over or not on a ceiling roses? I not sure it does , as the terminals are small enough to accept a single conductor without doubling the ends over so it probably a personal choice. Don’t think I was having a pop at you Gaz , I wasn’t ,I was just saying that the so called rule is we should double the ends over on single conductor . Personally I never do on lighting except for the switch. So it was a great demonstration Gaz. and to get a three core into an already fully occupied ceiling roses and make it look that neat and tidy is hard enough without doubling over the ends .
@Dog-whisperer7494
@Dog-whisperer7494 Жыл бұрын
@@GSHElectrical it was a question more than a statement. And not a reflection on you or how you made the connections .
@mustaf1987
@mustaf1987 Жыл бұрын
Hi... To rewire a bathroom extractor fan do you have to break down the wall or ceiling?please answer
@henrytwigger2245
@henrytwigger2245 Жыл бұрын
We're not in the EU anymore so can we have our old colors back ?
@ThomasJoe..
@ThomasJoe.. Жыл бұрын
Could you possibly do a video how to do this using the 2 plate method?
@GSHElectrical
@GSHElectrical Жыл бұрын
👍🏻
@GSHElectrical
@GSHElectrical Жыл бұрын
👍🏻
@ThomasJoe..
@ThomasJoe.. Жыл бұрын
@@GSHElectrical Thank you. The videos are great and very helpful
@barryford7135
@barryford7135 Жыл бұрын
I would be grateful for this as well.
@sergiofernandez3725
@sergiofernandez3725 Жыл бұрын
Question. Should that fan isolator not have a 3A fuse?
@GSHElectrical
@GSHElectrical Жыл бұрын
See manufacturers instructions and link in comments to another video Sergio 👍🏻
@sergiofernandez3725
@sergiofernandez3725 Жыл бұрын
@@GSHElectrical Cheers Gaz. As always you are a legend. Keep up the great work.
@mars6394
@mars6394 11 ай бұрын
How would you wire a fan if the feeds loop at the switches and not the ceiling rose
@neiltrevatt
@neiltrevatt 27 күн бұрын
Wire from switch you should have permanent feed and neutral plus switch feed and earth
@henrytwigger2245
@henrytwigger2245 Жыл бұрын
Now do it it above your head while you're balancing on step ladders in a dark room !
@johnwayne5984
@johnwayne5984 8 ай бұрын
Where do I buy tge wires that contain the black and grey? They were not even in B & q
@josh214haigh
@josh214haigh 6 ай бұрын
Try CEF. Three core and earth cable. I think I saw it in Wickes recently as well.
@triplex9732
@triplex9732 2 ай бұрын
Why they changed black as neutral i Don know
@johngrannan
@johngrannan Жыл бұрын
Hi Gaz. You’re getting your feed presumably from a 6A protected lighting circuit. However, most fan installations indicate that the fan should be protected by a 3A fuse. Hence, just checking that you wouldn’t feed to the fan via a FSU fitted with a 3A cartridge fuse and then through a 3-pole Fan isolator switch? Personally I wouldn’t use a FSU but ‘technically’ you’re then not following manufacturer’s instructions 😶
@GSHElectrical
@GSHElectrical Жыл бұрын
This should help for my other KZbin channel 👍🏻 GENIUS 🛁 - Bathroom fan isolator in a SINGLE module grid - clever thinking from Knightsbridge kzbin.info/www/bejne/h5m6n2x3is9jfbc
@AndrewStrydomBRP
@AndrewStrydomBRP Жыл бұрын
I specially avoid fans that have that requirement, completely idiotic design when they know that the fan will come off a 6a circuit.
@andysims4906
@andysims4906 Жыл бұрын
I was working in a house less than 5 years old . The so called electrician used the black in the triple as the neutral and the grey as the switch live. On the bathroom fan .Checked the smoke alarms and yes black used for neutral. Moral of the story is double check and don’t assume Some fan manufacturers specify a 3 amp fuse. What’s the view on that .
@Dog-whisperer7494
@Dog-whisperer7494 Жыл бұрын
A bathroom fan is unlikely to have a power rating more than about 15 watts so 3amp fuse is fine if the fan is fed from a fused connection unit, 15w /230v = 0.065 amps. but in Gary’s video he is talking about feeding the fan from the lighting circuit therefore it is protected by the 6amp MCB/ RCBO for the lighting circuit.
@GSHElectrical
@GSHElectrical Жыл бұрын
Alway look at the manufacturers instructions Note you don’t necessarily need an isolator but it’s stated in the instructions 👍🏻
@GSHElectrical
@GSHElectrical Жыл бұрын
Alway look at the manufacturers instructions Note you don’t necessarily need an isolator but it’s stated in the instructions 👍🏻
@intercity125
@intercity125 Жыл бұрын
Crystal clear - BS7671 says you need to install to manufacturer's instructions. 3 amp fuse in a fused spur off you go. (Have a look at the wiring gauge inside the product, soon see why...)
@gibberingidiot
@gibberingidiot Жыл бұрын
Most (decent) fan suppliers (Envirovent are the ones I use) seem to have updated their instructions recently to say that it's fine if run from a local lighting circuit protected by 6A (It's not that uncommon to find lighting circuits on 10A). I refuse to use a brand that doesn't say that now, though I've also used the Click range to make up an isolation switch with fuse carrier in a single plate. Does beg the question whether you fuse the permanent live or the switched live, or both though!
@gazz9995
@gazz9995 5 ай бұрын
i thought having an extractor fan in the bathroom you'd have to make it 12v no ?
@GSHElectrical
@GSHElectrical 5 ай бұрын
No 👍🏻
@gazz9995
@gazz9995 5 ай бұрын
@@GSHElectrical Extractor fan in shower cubicle would have to be an extra low voltage unit 12Volts with a separate transformer mounted away from the shower in a safe zone these units are made for Showers -Bathrooms
@davidclarke2513
@davidclarke2513 7 ай бұрын
Why aren't you suggesting that a double pole switch fused spur to downgrade the fuse to suit the fan installed as most fan manufacturers put in the instructions that you install one ,in fact one electrical manufacturer sells a a double pole grid switch which is a fuse
@eicrcomplianceltd7590
@eicrcomplianceltd7590 Жыл бұрын
I've watched your videos from time to time while I'm on KZbin tho it's more for trainees. But today you says something that over the years I'm puzzled with. There's nothing wrong with it, but, why on earth every where you goes, doing work on site it is the black they wants you to use for the permanent? My argument is at all times, if you comes out a DB to supply an equipment 9.999999 times out of ten you comes out with brown. So why not keep brown permanent? Instead of switching over to black if using a 3 core? If you can't identify the cable throughout the installation you shouldn't be doing it then, I know some will say if I use black I know that's the permanent you don't get mixed up.
@GSHElectrical
@GSHElectrical Жыл бұрын
Thanks for your input and continued support. It will be interesting to see if others comment on this post. All the best Gaz
@UnimportantAcc
@UnimportantAcc Жыл бұрын
Imo using black as switch makes sense too since you can slap a bit of brown sleeving on it, identifying it as a switch line the same way you would /w a blue
@eicrcomplianceltd7590
@eicrcomplianceltd7590 Жыл бұрын
@@UnimportantAcc of course it does, but everyone seems to bent on black benn you for permanent on every installation. Like I've said nothing wrong with using it, but don't see the sense of not wanting to use brown throughout.
@gibberingidiot
@gibberingidiot Жыл бұрын
I agree that using black as switched live (with brown sleeving) makes the most logical sense. In a light switch using switch drops, the switched live core (blue or black depending on age) has brown (or red) oversleeving to show that it's a switched live - so seeing a cable with brown oversleeving would mean switched live in both situations rather than having to work out which is which. Never assume though, given how rarely I find sleeving actually in place.
@Klberts1234
@Klberts1234 9 ай бұрын
I was always shown to use a fcu/ fan isolator to 3a fuse. Also fan isolator only needed if no window in bathroom i believe You can get a fan isolator with a fuse holder in also
@chequers5187
@chequers5187 4 ай бұрын
In a domestic install in NZ & Aussie this method is considered bad practice,the feeds can only come into the switch plate.
@kingcobrauk
@kingcobrauk 9 ай бұрын
Yet another youtuber person not installing a fuse inline for the fan, don't you youtubes ever read the instructions that are supplied? Come on if m8 if you are going to make a how to video don't you think it should be correctly done?
@scott4shell
@scott4shell 8 ай бұрын
Your first mistake was using a greenwood fan
ЧУТЬ НЕ УТОНУЛ #shorts
00:27
Паша Осадчий
Рет қаралды 9 МЛН
Iron Chin ✅ Isaih made this look too easy
00:13
Power Slap
Рет қаралды 35 МЛН
Beautiful gymnastics 😍☺️
00:15
Lexa_Merin
Рет қаралды 15 МЛН
How to Wire a Ceiling Rose | One Way Lighting Explained
13:15
The DIY Guy
Рет қаралды 116 М.
How to wire an extractor fan
17:07
Office Boy Builder
Рет қаралды 41 М.
Fault finding on a S plan wiring system
4:48
Ian Hall
Рет қаралды 12 М.