How to wire and configure a Hikvision Access Controller

  Рет қаралды 38,873

COP UK

COP UK

Күн бұрын

Пікірлер: 41
@mitkotomov2532
@mitkotomov2532 Жыл бұрын
Really found this video to be incredibly helpful! Looking forward to more content like this in the future.
@COPLtd
@COPLtd Жыл бұрын
Glad it was helpful!
@farmo26
@farmo26 9 ай бұрын
Very good. How do you add a user PIN instead of a card?
@remimercier19
@remimercier19 9 ай бұрын
Same question here!
@odysseus4101
@odysseus4101 Ай бұрын
What terminals are used in the controller and the actual settings for combining several controllers into one (if the system operates autonomously, that is, without connecting to a local network)? Perhaps UP-link RS-485... The dip switch is used to set the device number, by default it is 0
@mohssineelbakalikassimi7909
@mohssineelbakalikassimi7909 2 ай бұрын
Hi there, I followed all the steps in video which is very easy and well made (thanks) the problem I encountered is when I scan the fob to add a user I can hear the beep but nothing happens. Please help
@Raul-mb2sm
@Raul-mb2sm 5 күн бұрын
Hello. When I try to add a device, I get this error, hcnetsdk.dll 7.Can you help me?Thanks.
@mohssineelbakalikassimi7909
@mohssineelbakalikassimi7909 2 ай бұрын
Hi there, Any instructions about powering the panel? Thx
@napocensis8323
@napocensis8323 8 ай бұрын
Hello. Any idea why card reader (DS-K1107A), connected to a DS-K2602-G controller will not read HID Proximity 1346 ProxKey III H10301 key fobs? The reader does not even detect the key fob, does not beep. The reader is set to Wiegand 26 and is able to register other card types. Hikvision tech support were unable to figure it out. Thank you.
@AnjaniShukla-yc9vs
@AnjaniShukla-yc9vs 5 ай бұрын
Great video
@ted0beats-remixes56
@ted0beats-remixes56 Жыл бұрын
May I ask if you know - can a Paradox Reader work with Hikvision Controller?
@COPLtd
@COPLtd Жыл бұрын
Yes, you can! You would need to use Weigand wiring protocol for any third-party reader into the Hikvision Controller.
@dani290488
@dani290488 29 күн бұрын
cool Video. i have a question: is it possible to add a DS-KV9503-WBE1 with DS-K2604T? How can i do it?
@kayodeajibade1820
@kayodeajibade1820 2 ай бұрын
I also want to know if the DS K2604T is a reader in reader out ( I don't want to use exit button)
@COPLtd
@COPLtd 2 ай бұрын
Hi, the DS-K2604 is a 4 door controller that supports 8 readers via RS485 for read in and read out.
@Сергей-у7у4ч
@Сергей-у7у4ч 3 ай бұрын
Can you tell me how to change the lock types? magnetic and non-magnetic ones are installed - NO and NC
@COPLtd
@COPLtd 2 ай бұрын
Hi, In the controller, underneith each white relay, there is a jumper. Move the jumper over to change between NC and NO.
@mohammadalmanasrh134
@mohammadalmanasrh134 Жыл бұрын
Very useful ❤
@COPLtd
@COPLtd Жыл бұрын
Thanks 😊
@liamhannan9374
@liamhannan9374 6 ай бұрын
Hi Oliver, Thanks for Great video. Would this system work with a pulse door lock motor? Including a break glass to allow the door to be open when the power drops out? Many Thanks Liam
@COPLtd
@COPLtd 4 ай бұрын
Yes, absolutely
@yasirmydeen7845
@yasirmydeen7845 Жыл бұрын
Can you put one video for intercom using hikcentral professional
@COPLtd
@COPLtd Жыл бұрын
Thank you for your comment. A video of this will be available soon
@dagmawimessele1761
@dagmawimessele1761 Ай бұрын
tanks bro
@amuwastephen771
@amuwastephen771 4 ай бұрын
Is there a controller for more than 4 doors, say 40 doors like an office building
@COPLtd
@COPLtd 4 ай бұрын
Hello, The 2700 series controller allows you to manage upto 128 doors from a single controller when using with the 2 door modules. kzbin.info/www/bejne/npmTXmSIfLeKarssi=7tEou0SA-Uw_8z6h
@cjkokay
@cjkokay 10 ай бұрын
Here a clue, at 1118 you show resistors then at 1128 you show VarResistors, two different things. Also thos should ne at the lock end so the fly wheel effect gets absorbed into the coil of the device not the contact of the controller end.
@COPLtd
@COPLtd 10 ай бұрын
Hello, Thank you for the interaction, the resistors shown at out of the box and also in the wiring example are actually both types Piezoresistors. Piezoresistors are designed to protect the relay in the controller as well as to prevent maglock burn-in when a change in resistance when it is strained. This is demonstrated as bridging across the Lock+ and Lock- which wires to V+ and V- on the maglock and not across the relay. This is as per the manufacture CE approved guides. Whether these are wired on the maglock, halfway down the V+ and V- cable or at the controller end does not make a difference, so long as this is before the relay, in which case this is.
@mohssineelbakalikassimi7909
@mohssineelbakalikassimi7909 Жыл бұрын
Hi there, Is the software free when you buy the equipment? Link where I can buy the system?
@COPLtd
@COPLtd Жыл бұрын
The software is free to download from the Hikvision website: www.hikvision.com/uk/support/download/software/hikcentral-access-control-v2-0-1/
@kayodeajibade1820
@kayodeajibade1820 2 ай бұрын
I have 10 doors which panel do I go for?
@COPLtd
@COPLtd 2 ай бұрын
Hi, You will either need 2X DS-K2604 and 1x DS-K2602. Alternativley, you could opt for the Ultra Series controller, DS-K2704 with 3X 2 door modules DS-K2M002X kzbin.info/www/bejne/npmTXmSIfLeKarssi=L2iuQSOfrZjX8oyi
@yasirmydeen7845
@yasirmydeen7845 Жыл бұрын
Very nice
@COPLtd
@COPLtd Жыл бұрын
Thank you for your comment!
@yasirmydeen7845
@yasirmydeen7845 Жыл бұрын
How to add third party finger terminal with hikvision 4 door controller
@yasirmydeen7845
@yasirmydeen7845 Жыл бұрын
Can you share your mail id for technical support
@COPLtd
@COPLtd Жыл бұрын
@@yasirmydeen7845 Hi, the fingerprint reader takes a fingerprint read, and then uploads a card number to the controller to open the door. Due to the fact it requires a half-duplex protocol, this needs to be RS485 wiring which is reserved for Hikvision readers only.
@MertNazmiSerin
@MertNazmiSerin 5 ай бұрын
i am getting crazy everthinh ok , but on realtime monitoring it says " Card No. Does Not Exist and invalid "
@MuhammadIkhlaq-l7u
@MuhammadIkhlaq-l7u 6 ай бұрын
Good
@MrAlauddin95
@MrAlauddin95 10 ай бұрын
W
@dagmawimessele1761
@dagmawimessele1761 Ай бұрын
more bro
How to setup an access control system using zkteco f18 device
13:41
Tech Inside Out
Рет қаралды 21 М.
Lamborghini vs Smoke 😱
00:38
Topper Guild
Рет қаралды 49 МЛН
coco在求救? #小丑 #天使 #shorts
00:29
好人小丑
Рет қаралды 76 МЛН
How Access Control Systems Work | Point Monitor Corporation
5:41
Point Monitor Corporation
Рет қаралды 38 М.
Basics of Access Control
4:08
Kantech Support
Рет қаралды 309 М.
Hikvision NVR Setup with PoE Switch
17:32
Best Security Devices
Рет қаралды 59 М.