Thanks for sharing the video. It gave me insight on how to handle an electrical breakdown involving the safety monitoring relay circuitry of a machine at my place of work.
@josepholuyomi71072 жыл бұрын
Very simple and straight to understand.
@emreaslankara91349 ай бұрын
Very easy to understand some job 🎉Thanks
@stephend Жыл бұрын
Best to add mirrored NC contact from the MCR to the reset circuit so you can check if the MCR is welded shut.
@darreneck37448 ай бұрын
simple and straight forward, thank you
@conradcarter354610 ай бұрын
Very Nice. I understand.
@ishanpatel8788 Жыл бұрын
GREAT WORK. GO LITTLE SLOW. ALSO MENTION USE OF RESET. WHY RESET IS REQUIRED. IF BY SOME REASON SOMEONE OPENS ONE DOOR OF A MACHINE, OR HIT E STOP, THEN THE SUPERVISOR MUST KNOW THE REASON TO OPEN THE DOOR OR HIT E STOP. IF THE RESET BUTTON IS CONNECTED WITH A KEY TYPE PUSH BUTTON, AND IF ONLY SUPERVISOR HAS A KEY FOR RESET BUTTON, THEN IN THIS CASE THE MACHINE OPERATOR CAN NOT START THE MACHINE UNLESS, SUPERVISOR COMES TO MACHINE AND INSERT HIS KEY AND RESET. AND THEN DOCUMENT THE REASON OF HITTING E STOP OR OPENING THE DOOR. HITTING E STOP IS ACTUALLY SERIOUS MATTER. E STOP IS NOT LIKE AN ORDINARY STOP BUTTON. THIS IS A SAFETY. SOMEONE CAN LOSE LIFE. PLEASE EXPLAIN SUCH THINGS ALSO. ONE MORE THING, THERE IS NO USE OF OTHER CHANNEL FOR OUTPUT. GENERALLY TWO CHANNEL WITH TWO MCR IN SERIES ARE USED, REDUDANTLY FOR MORE SAFETY. IF ONE MCR CANT OPEN THEN THE OTHER WILL PROVIDE SAFETY. REST, THE VIDEO IS EXCELLENT.
@autoblipper3546 Жыл бұрын
Great explanation
@KevinHyde-r8m5 ай бұрын
There should be 2 relays both with n/c contacts in series with reset button. This is called reducency so if one relays contacts are welded close the safety relay will not reset.
@waqarulhassanjilani69867 ай бұрын
Thanks for the informative video and please create the next video on CAT-3 safety relay.
@MatXrix2 жыл бұрын
Super easy to understand, great explanation!
@mussabibrahim6203 жыл бұрын
Very helpful thanks bro
@sabiriwayuser13 жыл бұрын
Very knowledgeable video
@abdulgaffarmohammedshafee93333 жыл бұрын
Thank you very much & if it is connected to VFD, as well how to find fault. Appreciated
@GiosueMannino5 ай бұрын
S1 S2 on the VFD
@michaelcostello6991 Жыл бұрын
Good video. You should have explained the purpose of the MCR also as this is an introduction video
@sajinelectro2 жыл бұрын
Thank you very much..you helped me
@londonboy94222 жыл бұрын
Brilliant video!
@JaykeSapalaran-iq3qs Жыл бұрын
Great video tutorial 👍 ,How many stop push botton can install at safety relay?
@EASYPLCTRAINING Жыл бұрын
It depends how many channel relay we are using . Most of the relays have 4 ot 2 channels .
@abhishektiv44003 жыл бұрын
Really I needed this so much Can you please make some more videos on Safety relay?
@EASYPLCTRAINING3 жыл бұрын
kzbin.info/www/bejne/aJCnk6aEl6triZY
@abhishektiv44003 жыл бұрын
@@EASYPLCTRAINING sir I want to know how switching takes place- Like normal relay or PNP switching?
@EASYPLCTRAINING3 жыл бұрын
Normal relay
@abhishektiv44003 жыл бұрын
@@EASYPLCTRAINING Sir Can you give you mail ID- I want to share picture of Safety relay which we use!!!
@abhishektiv44003 жыл бұрын
@@EASYPLCTRAINING Thanks
@B1063N Жыл бұрын
Useful thanks
@highspeedgaz2 жыл бұрын
Well Done ,
@vignesha4507 Жыл бұрын
Please do the same for pheonix contact safety relay material.
@rajeshgaming51602 жыл бұрын
Sir, why are we using contactor in this circuit
@suriyat8773 Жыл бұрын
Thank you
@fatihyilmaz51493 жыл бұрын
Çok teşekkür ederim
@AnilAutomation3 жыл бұрын
#anilautomationhindi Bienvenido
@PTinvest3 жыл бұрын
How to wire Safety relay omron G9SE 221 T30 to E-Stop with a reset switch and VFD + electrics witch on / off + reset switch + emergency stop + contactor
@santiagogomez949 Жыл бұрын
Mejor seria explicarlo con un detector de seguridad, asi podriamos ver que tenga que estar implementado todos los sistemas de seguridad. Una seta de seguridad puede estar conectada sin tener que pasar por el relay de seguridad.
@sujeetkumar-xb1yi2 жыл бұрын
Sir How to Bypass Relay in Circuit....when Relay not working
@ewolnai2 жыл бұрын
Why is a 2NC e-stop needed
@londonboy94222 жыл бұрын
It's needed here in this application for greater redundancy - i.e. if there is a fault in one of the contacts the safety relay will go into fault as it's looking at both NC contacts. You could use a NC emergency stop button with a single channel safety relay, but having a 2NC emergency stop button with a dual-channel safety relay is safer, depends on what your application is.
@eswaresu251 Жыл бұрын
Channel 1 light is not on what is the problem....!? Plz feedback me