Possibly one of the best videos ever. Great explanation you nailed it. “To teach is to learn again”
@jhoney23462 жыл бұрын
Good work dude thanks for the refresher course
@bsahale3 жыл бұрын
Love your work.
@ledepart.design Жыл бұрын
Wonderful clean job! Greetings from eastern Arabia
@Soldier_4_Christ3 жыл бұрын
This dude is an animal he’s over here promoting dewalt while humbly admitting Milwaukee is good as he drinks a body armor and throws it on the ground this dude is a savage.
@mingliao43123 жыл бұрын
Cool dude done a excellent job!
@rippleaffect16983 жыл бұрын
Thank you
@SuperGurumoorthy3 жыл бұрын
Cool video, thanks for sharing
@rippleaffect16983 жыл бұрын
Hope it was useful and thanks for watching
@Doughboyz4122 жыл бұрын
great video
@leegordon80343 жыл бұрын
I like your work man keep it up 🖒hope one day I can be among u guys working
@rippleaffect16983 жыл бұрын
Thank you man I appreciate that, if your ever in tn we hire green and train you up so you can turn that hope into a goal and make it happen!
@joedmillermiller3 жыл бұрын
I was sitting here eating my sugarless gummy bears. The flavor was a tad off but I thought maybe I was losing my tastebuds because of the 'Rona. Suddenly, I had a massive case of BG's. For you that don't know. Thats the bubble guts. I rushed to the closest restroom to relieve myself, unable to make it in time. With liquid doo-doo oozing out of my pant legs I finished the last 40 yards to the restroom, at a speed that I could qualify for the NFL. As I sat here crying internally in quite shame and pain, I suddenly came across this video. Thank you. Thank you for making me forget that I dont have a change of underwear and am no where close to my house.
@rippleaffect16983 жыл бұрын
😂 your welcome
@nicholasaguilar62853 жыл бұрын
sum suslinz
@tebbink3 жыл бұрын
Becarefull Boss... 👍👍
@rippleaffect16983 жыл бұрын
Always! Thank you.
@matthewellis30044 ай бұрын
Nice work
@inquisitive9805 ай бұрын
I always use plastic bushings on connectors.
@wuukaa90793 жыл бұрын
This is so interresting!
@rippleaffect16983 жыл бұрын
Thank you.
@joedmillermiller3 жыл бұрын
Electricians are always so handsome and manly
@robertmartin5167 Жыл бұрын
I like your video every much , it is very informative to me .where the disconnect is install on strut ,do you bolt it to the roof . Can you make more video like this
@rippleaffect1698 Жыл бұрын
It's sitting on roof boots so it doesn't damage the roof membrane.
@adriansangerman34912 жыл бұрын
Is a grounding bushing required?
@nobodydummy123453 жыл бұрын
Of your using reducing washers you need bonding bushings on your seal tight connections yo!
@rippleaffect16983 жыл бұрын
Hey David thanks for your response, You have a great point but in this instance in this location I am code compliant the reducing washers we used were ul listed and we had no concentric rings. 250.97 EX. 4 From UL GROUNDING Metal reducing washers are considered suitable for grounding for use in circuits over and under 250 V and where installed in accordance with ANSI/NFPA 70, "National Electrical Code." Reducing washers are intended for use with metal enclosures having a minimum thickness of 0.053 in. for non-service conductors only. Reducing washers may be installed in enclosures provided with concentric or eccentric knockouts, only after all of the concentric and eccentric rings have been removed. However, those enclosures containing concentric and eccentric knockouts that have been Listed for bonding purposes may be used with reducing washers without all knockouts being removed. But it is a good practice to put them on everything when dealing with 480V especially when outdoors.
@mylestaylor98772 ай бұрын
👀👀9:40 ” I’ll stick it in”
@anthonyesparsen9453 Жыл бұрын
Guys don't cut towards yourself because if you slip you get cut, better to cut away from yourself
@AlexMartinez-dc4pe3 жыл бұрын
Plastci bushings missing at connectors, everything else good.
@rippleaffect16983 жыл бұрын
Nec. Section 300.4(f) only needs bushings for wire 4 awg and larger but it doesn't hurt to put them on all the time good catch but my wire size is in the parameters to not require one.
@willengram7091 Жыл бұрын
Must’ve missed the 1” and larger pipe.
@tonyn71683 жыл бұрын
im from Canada and its exactly the same way we do it, except our colours for the 3 phases are different
@rippleaffect16983 жыл бұрын
Thanks for the comment! Is your voltage the same 277..480
@tonyn71683 жыл бұрын
Nope, it’s typically 347/600 and 120/208
@rippleaffect16983 жыл бұрын
So 120 208 is common here but I'm interested on how your working with 347/600 is that considered your industrial type panels for factories and plants?
@tonyn71683 жыл бұрын
@@rippleaffect1698 yep our warehouses, factories, oil refineries, even some office towers are all 347/600. I have yet to seen 277/480
@rippleaffect16983 жыл бұрын
So can you explain it a little like from the transformer to the panel you dont have to but I'm curious
@nathanbecker22229 ай бұрын
Shout out to Body Armor! 💯
@JoseOPerezRuiz2 жыл бұрын
Did you have any Problem connecting a 480 WYE Hi to a 208 WYE Lo color code?
@sylvesterstewart8683 жыл бұрын
How is your Unislut racking secured to the roof? Would love to see the transformer.
@rippleaffect16983 жыл бұрын
Its built on roof boots.. Heavy rubber with strut bolted to the top
@sylvesterstewart8683 жыл бұрын
@@rippleaffect1698 Interesting, I really enjoyed watching you wire that AC unit. You remind me of a dude I did solar with.
@rippleaffect16983 жыл бұрын
Thank you
@nomadismileseeker66113 жыл бұрын
Could you adapt this to interrupt for a 240v 4 wire plug? Like from a generator?
@rippleaffect16983 жыл бұрын
Not for this application because it is 480v
@mv877111 ай бұрын
If the source wiring is coming from the panel with a breaker, then the disconnect would be non-fused for a 220v, single phase system for an HVAC unit?
@henryhenry2712 ай бұрын
no torquing?
@ehongrobles9159 Жыл бұрын
DeWalt baby
@Gamer-Family763 жыл бұрын
Hi there I was wondering if you could give me some info How can you take a 3 phase meter Box remove it and replace it with a single phase meter Box
@rippleaffect16983 жыл бұрын
Need some more info are you replacing a panel from 3 phase to single phase? Or just replacing a meter but keeping the 3 phase panel
@nicholasaguilar62853 жыл бұрын
FOUND YOU BOI
@rippleaffect16983 жыл бұрын
😂
@Flipping_Assets Жыл бұрын
How do I ground a wire on a 3 phase 3 fuse electrical disconnect box if I'm hooking up a 3 wire welder outlet?
@rippleaffect1698 Жыл бұрын
Look Into the NEC code book section 250
@errinwright8 ай бұрын
Berry Lemonade Bodyarmor
@anthonypicozzi4414 Жыл бұрын
You don't need to pull a neutral ??
@rippleaffect1698 Жыл бұрын
No sir, it's not required for this air unit.
@robanderson41373 жыл бұрын
I don't understand why there's no neutral white wire? Ya I'm a newb, just tryin to understand 3 phase
@rippleaffect16983 жыл бұрын
It's a 480v motor that is being powered so it doesn't require a neutral.. Also if a 277v 480v system did need a neutral it would be grey, white is standard in the u.s. for low voltage systems such as 120v 208v
@robanderson41373 жыл бұрын
@@rippleaffect1698 Thanks for the info...I work in an office building with three phase 277 and 120 possibly 480...not sure. I'm just working with LED lights and stuff but it's all different from residential.