HVAC Full Vacuum Procedure From Start to Finish!

  Рет қаралды 715,735

AC Service Tech LLC

AC Service Tech LLC

6 жыл бұрын

In this HVACR Training Video, I go over how to Perform a Fast and Deep Vacuum for Dehydration of an Air Conditioning System. I go over the Pump, Hose, Valve Core Removal Tool, Micron Gauge Setup, and Step By Step Process to Complete this Procedure Effectively. I go over some hiccups along the way and how to deal with them. Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety.
Tools Used In The Video
CPS 4 CFM Vacuum Pump - amzn.to/2DxgPwY
CPS Vacuum Micron Gauge - amzn.to/2v1nM3O
Appion Valve Core Removal Tool - amzn.to/2uYr8WL
Refrigerant hoses with valves amzn.to/2aBumVI
SDMN5 Dual Digital Water Column Manometer: amzn.to/2x176im
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our Related Videos/Articles
• HVAC Tips to Avoid Vac...
• HVAC Full Vacuum Proce...
• HVAC Vacuum Procedure ...
• Vacuum Pump AC Lines a...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
All Our Educational Products on Our Site: www.acservicetech.com/store
All Our Educational Products on Amazon: amzn.to/48pDd82
Mini Split Book and E-Book on Our Site- www.acservicetech.com/mini-sp...
Mini Split Paperback on Amazon- amzn.to/3ytHJSs
Mini Split Paperback on TruTech Tools- www.trutechtools.com/BooksGui...
Refrigerant Charging Book and E-Book: www.acservicetech.com/ac-book
Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Online Resources!
Our HVAC Calculators: www.acservicetech.com/hvac-ca...
Our Newest Articles: www.acservicetech.com/articles
Try our HVAC/R Quizzes! www.acservicetech.com/quizzes
Our Other Resources: www.acservicetech.com/resources
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Tools Used in Our Videos!
Tool Links on Our Site: www.acservicetech.com/tools
Our Tool List on Amazon: www.amazon.com/shop/acservice...
Support the Channel by purchasing tools through TruTech Tools!
Use this link www.trutechtools.com/?aff=8
Save 8% at checkout using code "acservicetech"
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Follow Us On Our Social Media & Podcasting Channels!
Patreon: / acservicetech
Facebook: / acservicetech
Instagram: / acservicetech
X: / acservicetech
LinkedIn: / ac-service-tech-llc
Tiktok: / acservicetech
Spotify: open.spotify.com/show/74KXLz5...
Apple Podcasts: podcasts.apple.com/us/podcast...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
⚠️ Disclaimer:
Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided. ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
#hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #oil #vacuumpump #2hose #hose #airhandler #heatpump #acunit #airconditioner #vacuum #vacuumprocedure #procedure
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

Пікірлер: 528
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Tool List- www.amazon.com/shop/acservicetech Support- www.patreon.com/acservicetech For those that are looking for the tools used in the videos: (Linked Below) Here is a link to the JB 6 CFM Vacuum Pump amzn.to/2nqbvo8 Here is the link to the Appion Valve Core Removal Tool- amzn.to/2uYr8WL Here is the link to the CPS Vacuum Micron Gauge- amzn.to/2v1nM3O Here is the Link to the Appion Blue 3/8" to 1/4" Vacuum Hose- amzn.to/2uYlVyc Here is the Link to the Appion Red 3/8" to 1/4" Vacuum Hose- amzn.to/2uYg6Ro Here is the link to the Yellow Jacket 1/4" by 1/4" heavy duty hose straight- amzn.to/2umtcod Here is a link for RectorSeal Bubble Gas Leak Detector amzn.to/2ckWACn Here is the link to the pack of 25 C&D valve cores- amzn.to/2J1lurm Here is the link for the C&D Valve Core Wrench, Container, and 3 valve cores- amzn.to/2EVGkps Here is the Link for the newer UEI DL479 Multimeter with temp sensor- amzn.to/2jtsUbJ Here is the Link for the FieldPiece ST4 Dual Temp Meter- amzn.to/2AhR6ph Other tool links can be found in the video description section. Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal- www.amazon.com/shop/acservicetech All of the ACSERVICETECH Playlists- kzbin.info/door/OZR-1IqsAer9wzlvFgb4mAplaylists?view_as=public
@prodjay10
@prodjay10 5 жыл бұрын
I'm about to order the tools to pull a vacuum using your list, but I'm confused as to which hoses I need. You have a red and yellow hose in the video, but a red, blue, and yellow hose listed. The yellow hose is not yellow once I click on the link. This is what I'm ordering: 3)Appion Valve Core Removal Tool- amzn.to/2uYr8WL 1)CPS Vacuum Micron Gauge- amzn.to/2v1nM3O 1)Appion Red 3/8" to 1/4" Vacuum Hose- amzn.to/2uYg6Ro 1)Yellow Jacket 1/4" by 1/4" heavy duty hose straight- amzn.to/2umtcod 1)RectorSeal Bubble Gas Leak Detector amzn.to/2ckWACn 1)www.amazon.com/dp/B00SV8BCB4/?cv_ct_id=amzn1.idea.3TU6QWW7V7OQI&cv_ct_pg=storefront&cv_ct_wn=aip-storefront&ref=exp_cov_acservicetech_lv_dp_vv_d
@prodjay10
@prodjay10 5 жыл бұрын
Should I just buy a manifold gauge set and use it's hoses for a vacuum? I only intend on doing this once.
@MichaelMantion
@MichaelMantion 2 жыл бұрын
You may want to put a comment near the start of the video to remind technicians to use a A2L compatible compressor when using A2L and A3 refrigerants.
@michaelmerryman7806
@michaelmerryman7806 Жыл бұрын
So if my line set broke and dumped everything out, to recharge do I vacuum the new line set and the unit by leaving the valves open? Or do I close then and vacuum just the new lines before adding the 410
@randycapilitan978
@randycapilitan978 9 ай бұрын
Aaaaaaaaàaaaaaàaaaaalpapalp
@bobbigrant9158
@bobbigrant9158 9 ай бұрын
Finally got it up and running. The only delays we had was because we realized we needed some extra parts (I’ll list that below) kzbin.infoUgkxihMYiJNXcHdbH-7ihymsLz61l7jVyb5O . So we have a loft where our current hvac just couldn’t seem to keep cool during the summer. We have been using a window unit since we bought this house over 6 years ago (all the houses in this neighborhood were built in the 80’s and majority of the houses built like ours use a window unit). I hate window units because they are just so noisy and the one we had really only cools one side of the loft. I had contemplated upgrading our current HVAC, but with all the rising prices these days, it would take years before saving up enough to do that. With the advice of my father-in-law (used to run an HVAC business), he recommended we get an inverter instead. We thought we bought everything we needed, but there were just a few other parts we didn’t anticipate needing (which is what caused most of our delay). My friend and father-in-law did all the work to get it installed and running and now we have nice cool air circulating nicely throughout the entire loft. It is very quiet and even the outside unit is much quieter than our main HVAC unit. Saved ourselves thousands getting this.
@joshuacotton8114
@joshuacotton8114 Ай бұрын
You skipped the entire part where you hooked it up!
@Adman0402
@Adman0402 3 жыл бұрын
I've been watching your videos for some time, and I just now got the set up for this vacuum. It's absolutely incredible. Thank you for taking time to teach us newer techs the right way of doing things.
@soukavathkeomisy3858
@soukavathkeomisy3858 3 жыл бұрын
I've been in the commercial kitchen repair industry for 15 years and this is top notch. Awesome job man. Great tip for using that third valve core removal tool! I'm stealing this idea and subscribing.
@jimrika2
@jimrika2 6 жыл бұрын
Excellent, clear explanation. I appreciate the time and effort you are putting into every video. New techs need to subscribe and take notes.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks Jimrika2!
@runwayray
@runwayray 5 жыл бұрын
Excellent explanation and refresher for those of us that has been away from HVAC awhile. What you don’t use, you lose! Thanks
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Thanks Raymond!
@BennyBladez-
@BennyBladez- 21 күн бұрын
That’s a fact! Left for 10 years, went back to school for industrial maintenance mechanic and did that for 8 years. That was enough. I rather deal with a much safer work environment and much less stress
@MC-mq8mh
@MC-mq8mh 6 жыл бұрын
I've learned so from this channel, I literally have a notebook full of notes just from these videos. Keep up the great work 👍🏽👍🏽👍🏽
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks MC!
@user-zd6fv5vx7c
@user-zd6fv5vx7c 6 жыл бұрын
My Brother has his own small A/C company and I help him when he needs help but he doesn't have time to teach me so these videos are Awesome !!!
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks robjoder!
@stestar09
@stestar09 3 жыл бұрын
Well have you asked ?? It's a bad doo if somebody doesn't have time for their family .
@jsmitty4675
@jsmitty4675 2 жыл бұрын
Our company is in ohio Gutridge if you are interested in an apprenticeship
@rickythomasson847
@rickythomasson847 2 жыл бұрын
@@jsmitty4675 I'm near teays valley WV. If this is still avaible message me . I'd be interested
@Stewartplumbinginc
@Stewartplumbinginc 5 жыл бұрын
Great Resource for HVAC Community! Thanks for the hard work in putting these videos out there!
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Thanks Stewart Plumbing!
@mike32oo
@mike32oo 6 жыл бұрын
Excellent video, I didn't know you could pull a vacuum this fast. Most of my vacuums took 1-2 hours because I never took out the schrader valves or uses hoses free of valve core depressors. Thanks man, this should save some time.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
It really does, check out the recovery and pressure testing videos too other processes, thanks
@DayClanTribe
@DayClanTribe 3 жыл бұрын
Old comment I know but wanted to point out that aside from the valve core removal, the key is in those larger hoses and as short as possible. Huge time saver.
@lennyc624
@lennyc624 6 жыл бұрын
I've been watching many of your videos and they are by far the most informative. Thank you.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks Lenny C!
@moisessanchez870
@moisessanchez870 6 жыл бұрын
Excellent videos you have, i always watch them and they have helped me. Thank you
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks Moises!
@IconMaintenance
@IconMaintenance 5 жыл бұрын
Thank you for taking the time to make and share this terrific video...it was informative, brief, to the point and easy to understand...
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Thanks a lot James!
@centerb541
@centerb541 6 жыл бұрын
Same vacuum pump we use at tech school. Great video man!
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks KuatoLives!
@vineetsehgal4738
@vineetsehgal4738 4 жыл бұрын
Why u not vacuum at highest low vacuum level like 15 micron?
@josemj059
@josemj059 6 жыл бұрын
Thanks bro for all the time you take to explain great work.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks for your comment JAMDYAC!
@knockitofff
@knockitofff 5 жыл бұрын
The gas ballast (if equipped) should be left open until 1200 microns, then closed, thereby bypassing the oil in the pump. Another nice trick to clean your oil and reuse it is to simply run the pump with ballast open, you'll actually see, in about 20 minutes, the oil clear right up if it's milky. The oil industry doesn't like this trick to be known.
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
We usually only keep the gas ballast open until around 10,000 to 15,000 microns, thanks!
@dakota7701
@dakota7701 5 жыл бұрын
Excellent video. Thank you for making this informative video.
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Thanks Maurice!
@felipeballi7679
@felipeballi7679 6 жыл бұрын
great video, great job on explaining the whole process.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks Felipe!
@azhvacr2332
@azhvacr2332 6 жыл бұрын
Very nice video, good info. Saves time and vacuum life. 👍🏼
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Yes absolutely, Thanks Manuel Torres!
@davepenprase
@davepenprase 6 жыл бұрын
thank you for sharing your knowledge
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thank you very much David!
@resurgensix
@resurgensix 3 жыл бұрын
Great example in real time. Saving that for review later for sure. Thx as always Craig!
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Glad it was helpful!
@NatureIsMyFriend
@NatureIsMyFriend 5 жыл бұрын
Thanks a lot for these videos, they are really helping me learn
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Thanks Prince!
@mojoemurphy
@mojoemurphy 5 жыл бұрын
Instead of spending all the extra cash on another CRT I just use a yellow jacket 45° all brass ball valve to the micron gauge. Also, I have the same 6 cfm pump and I made my own manifold. 3/8 Tee (NPT) to (2) 3/8 NPT to 3/8 flare. I started using 90° fittings so both flare fittings face forward. Good video.
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Got ya, sounds good! Sometimes in the past I found that the yellow jacket ball valve wouldn't hold at deep vacuum so that is why I switched to the valve core removal tool rated at 20 microns. Glad to hear it is working for you!
@HVACinSC
@HVACinSC 6 жыл бұрын
Enjoyed the video. Keep up the great work!
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks HVAC in SC! You have great work as well!
@jericosha2842
@jericosha2842 3 жыл бұрын
Good idea on core removers as a valve! Thanks for helping.
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
No problem!
@Gameboy_Steve
@Gameboy_Steve 5 жыл бұрын
Thank for all your videos they have helped a lot
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Glad to help Steve!
@emilfalck5470
@emilfalck5470 6 жыл бұрын
Happy Sunday,tks ,,God bless, from the good Land Milwaukee WI
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
May the Lord Bless you too Emil, Thanks!
@timothynovitski9133
@timothynovitski9133 3 жыл бұрын
Love this guys videos
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Thanks Timothy!
@WillianPortela
@WillianPortela 5 жыл бұрын
Thanks for sharing this wonderful video!
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Thanks a lot William!
@mymobilemechanic8896
@mymobilemechanic8896 2 жыл бұрын
Great explanation!!
@4brothers161
@4brothers161 3 жыл бұрын
I bought the Red hose, yellow hose and 1 Appion core remover since I already had 2 and tried this set up today. This works great. I pulled a vacuum down to 363 microns in 10 minutes and I didn't even change the oil on my vacuum pump.
@christophernewman2824
@christophernewman2824 2 жыл бұрын
Was it also a new line set?
@henrykelly7837
@henrykelly7837 2 жыл бұрын
Excellent
@yujen725
@yujen725 4 жыл бұрын
thank you for this good explanation video!! I was wondering, after you remove the core and after you vacuum the system, how do you add refrigerant while the core removal tool connected to the compressor and while the schrader is removed? also, how would you purge the hoses while using the core removal tool?
@cooltime3040
@cooltime3040 Жыл бұрын
Well done - thanks!
@acrepairnearme
@acrepairnearme 6 жыл бұрын
Thank you for the cool video! Very good explanation.)
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks Tapch MC!
@williamserver4332
@williamserver4332 2 жыл бұрын
Great video.
@qomco
@qomco 2 жыл бұрын
So quick. I gotta start doing it this way
@tommyteamer9037
@tommyteamer9037 Жыл бұрын
Thanks for showing how to do vacuum test and a leak check
@WillianPortela
@WillianPortela 6 жыл бұрын
Perfect work!
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks William!
@darrenskinner5928
@darrenskinner5928 6 жыл бұрын
Thanks great video
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks Darren!
@kylepronesti2954
@kylepronesti2954 3 жыл бұрын
great vid thanks for sharing. much more confident on my ac install tomorrow lol
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
You got this!
@johnperez4381
@johnperez4381 5 жыл бұрын
This was an informative video. Love how you made It easy to understand.
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Thanks a lot John!
@vegitoblue7908
@vegitoblue7908 4 жыл бұрын
@@acservicetechchannel Hi there. Is it normal when pulling vacuum. You turn the vacuum off and the vacuum doesnt hold the pressure??
@mikefixac
@mikefixac 2 жыл бұрын
Absolutely love this video and also the comments. This is kind of a physics question: When drawing a vacuum from both ports simultaneously, is it possible the vacuum can work against itself? Hope the question makes sense. Thank you.
@rickrossi7426
@rickrossi7426 5 жыл бұрын
Thank you. Very good video.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Thanks Kenny!
@mikecummings2188
@mikecummings2188 6 жыл бұрын
super video thank you very much
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks Mike!
@brianortiz2200
@brianortiz2200 5 жыл бұрын
Great video thanks for sharing
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Thanks Brian!
@pablorodriguez107
@pablorodriguez107 3 жыл бұрын
Good job!
@jamesrockford5145
@jamesrockford5145 6 жыл бұрын
A true professional.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks James!
@Kommaer
@Kommaer 5 жыл бұрын
..only, if he did'nt use a hammer on that outdoor unit :) (funny) :)
@MrG-hm7xs
@MrG-hm7xs 3 жыл бұрын
Great video thx...
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Glad you enjoyed it
@scotta9114
@scotta9114 2 жыл бұрын
Thank you for this fine video. Can't help but learn from it. I had a misfortune on a Service call. Hard lesson. Vacuum hoses didn't have Check-valves. Started the evacuation process and took a lunch. The Vaccum Pump blew the circuit breaker and the line-set sucked the oil out of my vacuum pump and contaminated the whole system. Was a bitch or flush out and recharge (R-22). Didn't make any money that day. Never gonna do that again! Anyway, thanks for the video.
@phillipjoy8191
@phillipjoy8191 6 жыл бұрын
Great video 😁
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks Phillip!
@fernandojr8436
@fernandojr8436 2 жыл бұрын
Your the man
@HVACRDUDE
@HVACRDUDE 4 жыл бұрын
Love the different service wrench sizes..they have 3
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Ha ha, that was the correct size but didn't quite fit well, the smaller two sizes were certainly too small thanks!
@padilla7019
@padilla7019 5 жыл бұрын
Another great video
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Thanks a lot Luis!
@edwinmillay9976
@edwinmillay9976 Жыл бұрын
Very good instruction. Could this process be done with only 1 valve core removal tool and 1 hose ?
@arturobolanos6061
@arturobolanos6061 3 жыл бұрын
Your video is the bomb.
@AL_ABAAS
@AL_ABAAS 9 ай бұрын
Amazing video, I wish you had your gauges in view when you opened the valve
@hvacguy542
@hvacguy542 4 жыл бұрын
Great video thanks a lot helps when you forget lol also helps for the apprentices
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
Glad to help!
@offthetrail636
@offthetrail636 3 жыл бұрын
4th time I’ve watched this. Thanks man I’m an apartment maint tech so I don’t get to do this very often
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Awesome, I'm glad the videos are being used!
@rip9452
@rip9452 2 жыл бұрын
man you are a BEAST! I watch all your videos and You are making me a better technician. Ac is my passion but i’m really into ice machines…. Do you have any videos on Commercial isomatics or Mitsubishi’s? Contact dealing with harvesting motors or timing relays. I also have really enjoyed learning walk-in freezers in about the defrost termination any kind of information on that we’d love to see it
@dr00andrew
@dr00andrew Жыл бұрын
as far as opening the service valves, if you buy the napa carlyle 3/8 drive 3/16 and 5/16 allen key bits, they will never fail you. the allen key is about 3 inches long and if you use a long handled ratchet, you will always have the proper depth into the service valve and leverage with the ratchet. it helps tremendously opening service valves
@jhonnychingass6252
@jhonnychingass6252 2 жыл бұрын
Best videos out there,,,,I have a question what side you open 1st when you install a condenser..low side or high side?and do you need to break vacuum? Or can I open valves with unit in vacuum?
@hediervarelamedina987
@hediervarelamedina987 Жыл бұрын
The question I have to ask is: is this kind of vacuum produced when the machine is fully charged with freon? when making a vacuum on a repair due to a change of compressor it can be done or in that case if it has to be done with the set of pressure gauges on. I appreciate the attention provided .
@usahoangsatruongsa
@usahoangsatruongsa 4 жыл бұрын
Why did you release the refrigerant by opening the low side first ?? My helper did it once and it made a loud hissing sound like something is leaking. Thank you for sharing your knowledge and experiences.
@erics9213
@erics9213 3 жыл бұрын
Why not 3/8" lines on both the liquid and suction lines. How long for the blowout? Thanks for these videos.
@mark.r8900
@mark.r8900 Жыл бұрын
Hi, after replacing a suction line and liquid line service valve do you perform the vacuum with both valves open? If so, wouldn't the vacuum pump pull compressor oil out of the system? Thanks
@freddyrangel4627
@freddyrangel4627 3 жыл бұрын
One question when doing the vacuum pump pressure test do you also have to take out the piston in the coil or do you leave it in there??
@alfredoandroid357
@alfredoandroid357 3 жыл бұрын
Thanks for the video , Where does the other end of red hose get connected to lol
@toemblem
@toemblem 4 жыл бұрын
Great video, thanks for posting. As far as breaking vacuum goes, I understood it to be a bad thing to open the service valves. I was told this is because the vacuum could pull too much oil out of the compressor. Am I operating on bad information? Also, I've found that the cooler you keep the service valves (while brazing), the easier they are to open.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
It certainly doesn't hurt to break the vacuum with refrigerant from the bottle. The manufacturer will usually say it is ok to open the service valves to break the vacuum. They tell you which one they would like to open first to avoid any oil lost into the tubes and out of the compressor for the initial startup, thanks!
@joeyysossa4144
@joeyysossa4144 Жыл бұрын
You should also mention to recover the refrigerent before dtarting the vacume presses...
@Alex-jo2oi
@Alex-jo2oi 11 ай бұрын
Lol a couple of people might get some refrigerant burns if they think to skip that part…
@andrewbutler1423
@andrewbutler1423 2 жыл бұрын
Would it be best after reinstalling the valve core to pull the stem back and valve off before removing the stem of the tool, just in case the valve core didn’t seat correctly in which case refrigerant would be release from the system. If you valve it off first you have full control of the refrigerant? Hope that made sense.
@Frank289100
@Frank289100 3 жыл бұрын
From your experience. If you have a leaking flare nut on the line sets on the mini split unit that loses gas every season. We're during the upcoming season you fill the system up topping it off, and have done this three years. I've noticed that the system now doesn't cool as well as it did when I first installed it. In your opinion and experience. Could the unit have taken in air affecting the performance of the unit. Where it would be a wise thing to remove all the gas and pull a new vacuum and install new freon to get it to cool the way it did when it was first installed.
@rayeopp8957
@rayeopp8957 3 жыл бұрын
When do you use the clamp meter to measure the "A"
@FlyEaglesFly19111
@FlyEaglesFly19111 5 жыл бұрын
I always use fresh oil on each vacuum. And some systems need the oil changed after 5 min of run time. Apion..they are the best core tools..love them. How about a triple purge? Also I use the t and 3/8 hoses on my REFCO..9cfm.
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
I don't do a triple evac if the standing vacuum holds at the 200 or 300 micron level. This proves the moisture is gone. Yeah those appion's are awesome, thanks David!
@justinblack2984
@justinblack2984 Жыл бұрын
I have a question about the vacuum procedure, when pulling a vacuum and I have a fixed orifice, should I remove the orifice to perform an oil blowout and leave it out during the vacuum pump or just leave it in? Its a R22 and I'm retrofitting for R422B
@Rhythmhousedrums
@Rhythmhousedrums 5 жыл бұрын
Thanks for all your videos. Very helpful! Could I pull a vacuum from just one service valve using one hose? Is it just quicker to use two hoses or is there any other reason. I know smaller mini splits only have one service valve anyways.
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Minisplits have the metering device for the evap at the outdoor unit so there is no restriction halfway down the line like on standard split systems. That is why we pull from both sides and it is faster and you microns readings will be more accurate. No need to on minisplits, thanks
@workinprogress008
@workinprogress008 3 жыл бұрын
Is there a list on which line manufacturers recommend to open first?
@syntaxlies82
@syntaxlies82 4 жыл бұрын
I vacuumed my mini split down to 150. It rises 1 micron about every 10 seconds. Should I just run the vacuum longer or wait and see what it stops at if it stops?
@lopaka79
@lopaka79 2 жыл бұрын
Only thing I do different is adding a wireless transducer on the non-micron gauge core removal reference and only pressurize to 20ish psi. Allows for easier core install and lower de minimis.
@HonestDiner-cz4op
@HonestDiner-cz4op 8 ай бұрын
You opened service valves with wrench to break the vacuum. But I never saw you close them back up. Could you kindly explain!
@peterd6592
@peterd6592 9 ай бұрын
May I ask what is the purpose of opening the gas valve and close it after machine started? Can the gas valve be left open? What is its purpose anyway? Tks
@jonr4721
@jonr4721 3 жыл бұрын
Ok first off great video. But I have a question, it's a 60-65 ft lineset and the outdoor comes orecharged for 15 ft of lineset so 45-50 ft * .6 Oz per foot needed how did you add the 27-30ish ounces of 410?
@davidb2438
@davidb2438 4 жыл бұрын
Are there any problems cross threading a Schrader valve using the valve core removal or does the tool help align the valve properly?
@Josh-px6xb
@Josh-px6xb 4 жыл бұрын
Question. I had two 3/8 hoses hooked up with 3 valve core tools with the micron gauge and I was able to pull to 390 microns but when it was finished & I went to isolate the vacuum and close the shut offs, I was instantly losing like 300 microns then it would hold. it passed nitrogen test also any ideas of what was happening?
@tonyloww281
@tonyloww281 2 жыл бұрын
What if you need to add refrigerant? Can you just use either of the top valves on the Apion Schrader removal tool?
@GurdeepSingh-bu6ee
@GurdeepSingh-bu6ee 2 жыл бұрын
Hello there, I the vacuum on the new system as per this video. Than ready to open service valve on suction side. Open the valve cap to do so. I lost the vacuum in the line set. What I'm doing wrong..? Thanks
@termite2691
@termite2691 4 жыл бұрын
Finally something that explains how you put the valve cores back in without screwing up all your good work.
@16hershey135
@16hershey135 6 жыл бұрын
Thank you . Like being on the job with you .
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks Lent Builders Inc!
@stevengao8345
@stevengao8345 3 жыл бұрын
thanks for the wonderful video, i have a question at the end that is why don't you put the shredder valve in before you break the refrigerant ? thanks
@TheBalterok
@TheBalterok 2 жыл бұрын
Had same question. Did you found an answer to that?
@garrythompson4132
@garrythompson4132 3 жыл бұрын
Am I to understand that the two vertical core valves are closed during these procedures eliminating the compressor? In other words, just the tubing from the valves thru to the evaporating coil are tested?
@rp4323
@rp4323 Жыл бұрын
If there is dye in a system does it evaporate. In other words will it affect getting it to hold a low micron level?
@troymason4799
@troymason4799 3 жыл бұрын
Can you put the Schrader valves back in before breaking the vacuum?
@klanda1095
@klanda1095 3 жыл бұрын
Hi , Do you have a video on vacuuming a 4 zone 36000 BTU mini split , 4 9000 BTU INDOOR UNITS .. Do you have to vacuum line sets individually or is there a way to do it in one shot ? Thanks
@strayhandycat2753
@strayhandycat2753 Жыл бұрын
Fellas! I need an advice. I vacuumed the 16 ft long line. Left the manifold connected. (While having the low pressure blue valve shut). After 1 hour, I could see the needle was going slightly down. (To -29?). After 10 hours, the system pressure goes back to 0. The question is, if this outcome normal? Online I read people say 15 minutes is enough to test lines with vacuum. Does it mean I loose vacuum due to the manifold connections? Or is there a great chance of a leak? Thank you!
@victordock7872
@victordock7872 2 жыл бұрын
great
@gtimikey1
@gtimikey1 2 жыл бұрын
Is it better or recommended to put micron gauge on discharge side of the core remover since its the furthest from the vacuum pump.
@Billpimentel82
@Billpimentel82 3 жыл бұрын
Question, the AC condensing unit is isolated when running a vacuum correct? unless there is no refrigerant at all in condensing unit?
@ranimouf
@ranimouf 2 жыл бұрын
Does the pump also gets rid of any left over freon in the copper lines if you'' re replacing an R22 condenser To a 410A condenser?
@aperlia6603
@aperlia6603 2 жыл бұрын
We pull down through our gauges with the yellow a massive vac hose. Honestly pumps down relatively quickly, generally under 20 minutes. This looks like way more work lol.
Refrigerant RECOVERY Procedure Step by Step! Fully Recovered!
9:32
AC Service Tech LLC
Рет қаралды 121 М.
40 VACUUM PROCEDURE TIPS for HVAC Techs! Avoid Frustration and Save Time!
27:12
Китайка и Пчелка 10 серия😂😆
00:19
KITAYKA
Рет қаралды 1,3 МЛН
1 класс vs 11 класс (неаккуратность)
01:00
Чай будешь? #чайбудешь
00:14
ПАРОДИИ НА ИЗВЕСТНЫЕ ТРЕКИ
Рет қаралды 2,7 МЛН
Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps, Tips!
27:56
AC Service Tech LLC
Рет қаралды 1,3 МЛН
How to Evacuate an AC system, Full Vacuum Procedure
27:35
HVAC School
Рет қаралды 1,1 МЛН
2 Hose Vacuum Pump Procedure VS 1 Hose Vacuum Pump Setup for HVAC!
19:24
AC Service Tech LLC
Рет қаралды 166 М.
ACR 101; Typical Residential Recovery, Evacuation, Charging
10:37
Palomar College; ACR Technology
Рет қаралды 50 М.
How To Use AC Gauges
26:34
Benjamin Sahlstrom
Рет қаралды 1,1 МЛН
How to Pull a Vacuum and Recharge Your AC System - ULTIMATE GUIDE - HVAC
25:45
HVAC Tips to Avoid Vacuum Problems! Top 15!
17:35
AC Service Tech LLC
Рет қаралды 205 М.
Soldering An HVAC Line Set Using Staybrite 8.  STRONGER THAN BRAZING!
29:04
How To Properly Clean An AC Evaporator Coil & Save HUNDREDS!
15:33
The DIY HVAC Guy
Рет қаралды 1 МЛН
Why I Choose A ONE Hose VACUUM Setup | HVAC Installations
12:54
Quality HVACR
Рет қаралды 158 М.
Китайка и Пчелка 10 серия😂😆
00:19
KITAYKA