HVAC Overloads and Safety Switches Don't Just Fail

  Рет қаралды 31,374

HVAC School

HVAC School

Күн бұрын

Пікірлер: 33
@InsideOfMyOwnMind
@InsideOfMyOwnMind 2 жыл бұрын
As a consumer, thank you for dedicating your career to improving the trade through good knowledge and training. You are making the world a better place for all of us.
@faintsmile3279
@faintsmile3279 2 жыл бұрын
this video talks to my soul. unfortunately i have a colleague who is an old timer whos been in business for 50 years and 20 years in this trade and still doesnt know refrigeration basics and he just replaces the entire unit if he has to so a 5minutes job can take up to 5 days instead
@djfxnc
@djfxnc 2 жыл бұрын
Siempre con muy buena informacion para quienes estamos empezando en la Industria 💯👍
@tobydwyer5602
@tobydwyer5602 2 жыл бұрын
Great lessons. Thanks from Western Australia
@adamradley4407
@adamradley4407 2 жыл бұрын
Up here in Canada an AC manual reset high side pressure safety switch can trip over winter. Not a failure of the system operation but due to temperature fluctuations over winter while the system is not in use. A quick reset and the system will run fine all summer.
@survivor-z3t
@survivor-z3t 2 жыл бұрын
Great explanation. No one tech us that very well in the field. Great job as always 👍👌
@scottallen5182
@scottallen5182 2 жыл бұрын
Great video Bryan!
@Stuart68505
@Stuart68505 2 жыл бұрын
Air at the circulating pump can result in the flow switch opening because the circulator cannot produce water flow if it has air at the impeller.
@rc5869
@rc5869 2 жыл бұрын
Awesome class thanks for posting these!
@brianmcdermott2430
@brianmcdermott2430 2 жыл бұрын
Great video. Thanks Bryan
@jamesmcevoy1274
@jamesmcevoy1274 2 жыл бұрын
Awesome class thank you
@channelcatchaser9426
@channelcatchaser9426 2 жыл бұрын
Great video
@tjyagalla5652
@tjyagalla5652 2 жыл бұрын
I have come across failed open float switch’s due to .. low voltage short .. float switch is rated at 1.25 amp max in a 3 or 5 amp circuit..
@joeshearer1247
@joeshearer1247 2 жыл бұрын
Yes agree
@Stuart68505
@Stuart68505 2 жыл бұрын
If it is a chiller and you bypass the safety flow switch it can result in freezing & breaking the evaporator if other safeties don’t stop the compressor. The low pressure cut out safety switch should stop the compressor if it responds quickly enough to prevent the pipes from freezing. Big compressors may temporarily bypass the low pressure switch on start up and if that bypass stays closed, the low pressure control will not work to open the circuit. This would be a disaster.
@kevinkrug466
@kevinkrug466 2 жыл бұрын
I want that shirt, when you gonna have that for sale?
@ralphnabozny8494
@ralphnabozny8494 2 жыл бұрын
this is fun. I should of been an A/C guy. what about heater boards dirty with dead lizards.
@joeyjustin6895
@joeyjustin6895 2 жыл бұрын
YA THEY DO JUST FAIL. TODAYS SWITCHES ARE MADE TO A MINIMUM SPEC IN. CHINA. AND THEY DO JUST FAIL
@prestigemechanical3600
@prestigemechanical3600 2 жыл бұрын
Agree, have run into plenty switches that are defective. The new gas valves Rheem and Richmond use have pilot safety circuits that just fail “ bad valves”
@newmanair2257
@newmanair2257 2 жыл бұрын
Ya rarely will a manual reset go bad but the thermal limits can be somewhat common I change 5-10 every winter and the new style high and low pressure switches are a joke they go bad quite often
@stephwaylonwells3218
@stephwaylonwells3218 2 жыл бұрын
👍
@muhammadusamakhan5295
@muhammadusamakhan5295 2 жыл бұрын
can we bypass any of these switch
@DOLOONEKRL
@DOLOONEKRL 2 жыл бұрын
For troubleshooting purposes, sure. Never leave a safety bypassed. It’s a safety for a reason.
@d3adp94
@d3adp94 2 жыл бұрын
If you know the switch and bad and don’t have a new one on you, sure. Then follow back with a switch when you get it. I would also tell the customer what you are doing to the system. Some customer may want you to wait to get part.
@InsideOfMyOwnMind
@InsideOfMyOwnMind 2 жыл бұрын
@@d3adp94 tbh I would be that customer. Why risk system/house/life when the part is likely in stock just not on the truck? I probably already waited longer than that for one o' y'all to come out in the first place.
@_n8787
@_n8787 2 жыл бұрын
@@d3adp94 No... You never bypass a high pressure switch, float switch, any high limit on a furnace or a vaccum switch furnace. Period.
@d3adp94
@d3adp94 2 жыл бұрын
@@_n8787 if you know a low or high pressure switch is bad and not actually going out on either high or low. Why not. It’s 90 degrees outside and the house is 80. You might consider it. Lennox is known for this. I would never by pass a high limit or float or roll out. Condenser, I would.
@realestateservicessaleshea99
@realestateservicessaleshea99 2 жыл бұрын
Fundamentals are fun! Thanks again for the videos! 🍺🍺🍺🥃🥃⛳🎳 Stay safe. Retired (werk'n)keyboard super tech. Wear your safety glasses!
Accumulator Facts & Tips
24:44
HVAC School
Рет қаралды 123 М.
Capacitor and Hard Start Myths Busted
28:41
HVAC School
Рет қаралды 253 М.
Мясо вегана? 🧐 @Whatthefshow
01:01
История одного вокалиста
Рет қаралды 7 МЛН
人是不能做到吗?#火影忍者 #家人  #佐助
00:20
火影忍者一家
Рет қаралды 15 МЛН
Мен атып көрмегенмін ! | Qalam | 5 серия
25:41
Residential Low Voltage HVAC Troubleshooting Class P1
30:49
HVAC School
Рет қаралды 161 М.
HVAC  076 Pressure Switch Refrigerant
16:34
Love2HVAC with Ty Branaman
Рет қаралды 46 М.
Refrigerant Overcharge Troubleshooting and Prevention
21:47
HVAC School
Рет қаралды 189 М.
Leak Search Tips From Bert
17:50
HVAC School
Рет қаралды 72 М.
How HVAC Refrigerant Pressure Switches Work & Troubleshooting!
19:13
AC Service Tech LLC
Рет қаралды 172 М.
HVAC - Isolate to Diagnose
17:55
HVAC School
Рет қаралды 27 М.
Class - What Superheat Signifies
17:07
HVAC School
Рет қаралды 249 М.
Diagnosing Poor Compression
13:53
HVAC School
Рет қаралды 81 М.
WHY IS THE COMPRESSOR STEAMING??
18:29
HVACR VIDEOS
Рет қаралды 72 М.