As far as the Inrush goes on the sc480..... for 80A and below hit the Inrush button 1 time For larger units (4 & 5 tons) that will pull over a 100 amps, you need to push the Inrush button 2 times and this will move the decimal point all the way to the right. Then you will have no problem capturing your higher Inrush readings. And as far as using the magnetic strap on the sc480, it's better to take it loose and slap it on top of the unit on the fan grill and then the meter will hang on the side of the unit perfectly without spinning around. That's really how it's designed to be used. Folding it down into the meter is just a nice way to store it. But the second magnet on the sc680 does add extra strength. You can also use the round hole in the end of the strap to hang it on something. Try the Inrush again on the sc480 and see how it works for you now 😎👍
@HVACGUY2 жыл бұрын
Thanks. I didn’t know that about the inrush on the 480. I kept trying to change the range on the front of the meter.
@sknight03912 жыл бұрын
@@HVACGUY now maybe that will change your mind back to the sc480. 😉👌
@SombraLocs2 жыл бұрын
I love my sc480 meter.
@sknight03912 жыл бұрын
@@SombraLocs FamSan 😎👍😎👍😎👍
@Ricoswavaey2 жыл бұрын
Do you have to do that with the sc680 press it 2 times to capture higher amps? Or does it automatically capture the higher amps?
@RPHDWideGlide2 жыл бұрын
I carry the 480 due to size.Great meter,does all I need it to do.I chose the 480 over the 680 due to price and size,if I ever upgrade my bag from the MB3 I may go 680.Great video though,very informative!!!
@josejulian51162 жыл бұрын
I have had the SC660 for years and no issues with it at all, love the leads
@dbmail5452 жыл бұрын
I used to work for a manufacturer of traffic light controllers and signal monitors. We used several different models of Flukes, and discovered that some models would fail a device when others would not. Our lead engineer looked into the issue and found that different model meters computed RMS A/C voltage differently.
@HVACGUY2 жыл бұрын
RMS can be quite important in some instances, and I prefer meters like these that are TRMS. But, I guess I’ve never asked how it’s calculated cause it would appear that it is straight forward - as it implies a mathematical formula they all follow.
@gregmercil39682 жыл бұрын
I used an SC480 (courtesy of HVACR Videos) for about a year, until it it became demon possessed or self aware and started giving me all kinds of false readings. I was in the middle of trying to diagnose a furnace low voltage issue when the meter finally crapped out on me. I had to rush to a supply house in the middle of the job before they closed to pick up a new one, and since they only had the SC440 I had to get that one. The 440 is ok and does most of what I need it to do, but my 480 was much better. One thing I really liked about my 480 was that it could test phase rotation. My 440 doesn’t have this feature. I’m planning to eventually get a new 680.
@Austin23191 Жыл бұрын
Great video Curtis. I just picked up the 680 yesterday and today is my first day using it. Fits a little tighter in my bag. Maybe next month I'll get a slightly larger veto
@nosnim22072 жыл бұрын
Nice! Was waiting for this upload!
@Silky_boi2 жыл бұрын
I’m considering the 680 more and more. I do primarily installs and like to be thorough on startup especially on those 3 phase RTU’s
@EverythingHVACR2 жыл бұрын
Nicely done! I've been looking at both these meters and I'm set on the 680 as well, too many features to go with the 480, I love fieldpiece
@tylarcole38282 жыл бұрын
I actually used my inrush today on the 480 no issue with a 4 ton compressor and caught the 147amp start up. You have to change the decimal point by pressing the button twice.
@MrMultitool2 жыл бұрын
I have an SC56 with the swivel head that I like a lot. After looking at the SC440 i decided it was a pretty good step up with the inrush feature. You do have to move the decimal to catch the inrush. I'm thinking of going back to my Fluke 16 for most troubleshooting and if I need an amp clamp use the 440.I came along when analog meters were what we used. How things have changed.
@Paulie12322 жыл бұрын
Really good information, thanks for sharing
@EverythingHVACR2 жыл бұрын
Just got my 680, check out the manual, you do have to calibrate the sensors, great job
@GARGOLASPERFORMANCECOATINGS Жыл бұрын
Good video and explanation 👍
@pavelspilberg93104 ай бұрын
Thanks for video! Why you use flue leads except fieldpiece?
@VoiD1x Жыл бұрын
Which one should I get
@Sal_needs_Salt2 жыл бұрын
I have a question, so I’m an electrical student and I was wondering if I would need a meter like this or I’d be fine with say a klein tools or Ideal brand. I noticed those don’t have magnets, and the field piece seems more versatile. Let’s say money isn’t a factor.
@JSATI2 жыл бұрын
Is there much of a difference between the 440 and the 480? I'm a student in refrigeration/heating classes. Instructor suggested the 440 as our first meter. I want to make an informed purchasing decision. Any feedback appreciated
@ishalljr2 жыл бұрын
The 480 is Bluetooth and can be use with measure quick, the 440 can not. I don't believe 3 phase rotation is available either.
@bryansimon40722 жыл бұрын
Have both. Like both. Still using an old hs33 until it dies.
@adamdeckard4897 Жыл бұрын
Im worried about my own smaller veto pro pac being able to handle the sheer girth of the sc680, let alone 12 inches. That is a lot of meter. Maybe if I just start by putting it in halfway the first couple times I use it…
@lillyinthefield27872 ай бұрын
did you do a whole tool bag pack out video so we can see what tools we need ?????
@TheMinecraftACMan2 жыл бұрын
So the 680 is the "everything and the kitchen sink" meter. I don't have a 480, but I do own a 260 as well. It's just my basic backup meter that I use if I need to.
@hvacblogger9 ай бұрын
Do they check millivolts dc?
@donaldgeter76572 жыл бұрын
So you are able to use the fluke test leads on a fieldpiece multimeter?
@brianporter43522 жыл бұрын
I had an SC440 meter that I liked a lot, but I mainly work in residential HVAC and never really used the inrush, the diode setting, the Hz feature and the duty cycle. I currently have an HS36 from FP. A very nice meter, but really thinking of going back to a clamp meter. Was thinking the SC640 would be ok, but also considering the SC260 as well. Again a lot of those features I never use(d). Anyway thanks for the comparison. By the way what does the power factor feature tell you?
@HVACGUY2 жыл бұрын
Power factor tells you how efficient a system is. Basically how much power is being converted into actual work. The closer the power factor is to 1, the better.
@johnhintz26942 жыл бұрын
What's a mini split?
@thomasmann35605 ай бұрын
I prefer the 480, cause it fits in my bag. Problem is when it died cause I got it wet the supply house only had the 680
@identifiesas65.wheresmyche954 ай бұрын
I'm a new tech and need to upgrade my meter to one with inrush. I see some of you are contemplating upgrading from 480 to 680; may I ask what functions you're missing on the 480? Is it just the swivel or electrical capabilities as well?
@HVACGUY4 ай бұрын
I think you lose the dc amps on the 480.
@anthonybernier99522 жыл бұрын
Can you post a video or a link to how to check micro amp dc and the difference in volts amps dc and amps dc. im not sure what the function you mentioned would be used on. You said "the SC 680 has volts and amps dc and that the 480 only reads micro amps dc." someone please help me out with this I'm very interested.
@billj48592 жыл бұрын
Will the fieldpiece app allow you to read borh meters at the same time?
@HVACGUY2 жыл бұрын
I haven’t tried that
@schalachi2 жыл бұрын
sis you get k type thermistor with this? and is it accurate?
@stephwaylonwells32182 жыл бұрын
👍
@johngallati81642 жыл бұрын
GREAT VIDEO THANKU
@realSamAndrew2 жыл бұрын
What have you done with/ how do you use your Ames meter?
@HVACGUY2 жыл бұрын
That little Ames Fork Meter is a fantastic meter for the price. I keep it in my truck, but it’s not my daily.
@jesusmeda73822 жыл бұрын
Do you buy you tool, or the company you work buy it .
@KB-wq5bb2 жыл бұрын
Question? So the main difference is if I'm working on mini splits the 680 is the one for that. So the 480 will not troubleshoot mini splits. Is that the only main difference besides the head rotation on 680.
@HVACGUY2 жыл бұрын
Most mini-splits, and higher efficiency systems use variable frequency drives. For some of those the 480 should work fine. But, others have what’s called a square DC wave form, which means the wave never goes below 0, like standard 60Hz supplied electricity - So, it’s technically a DC drive, even though it goes up and down. And the 480 can’t check DC amps, and would likely not be able to check Hz through the amp clamp either because of this. So, yes, that’s one of the big differences.
@KB-wq5bb2 жыл бұрын
Ok thanks great explanation for me. I'm determining which one to get to add to my joblink items. I really appreciate your help. Also ur vids/ work ethic I enjoy watching.
@RicardoLopez-vn6cn Жыл бұрын
Does anyone get the issue when you expose the meter screen to the sun it creates some black marks on it. If so what did you guys do to fix it?
@rdrgz228 Жыл бұрын
That’s a normal side effect. No fix to it. The sun is toxic to the displays on our tools. Will eventually make your screen die.
@hvacwiz7877 Жыл бұрын
to get higher amperage on the 440/480 you need to push the inrush button again.
@bowmag803 Жыл бұрын
I finally upgraded my sc420 to a 480
@zacharyreed452 жыл бұрын
I carry the sc680, it does it all.
@Ricoswavaey2 жыл бұрын
Does the sc680 measure inrush amps?
@HVACGUY2 жыл бұрын
Yes, it does. They both do
@Ricoswavaey2 жыл бұрын
@@HVACGUY ok great i saw you mentioned towards the end of the video lol thanks for the review I’ll be getting the sc680 by the end of this week I’m excited 😁
@matthewclemons15742 жыл бұрын
Fluke twistgaurd are awesome test leads. Have had lots of issues with the Fieldpiece test leads. Looking for a meter to check vfd on large air handlers.
@HVACGUY2 жыл бұрын
The 680 is a great meter for VFD’s, even if they have a DC output.
@Sctronic2092 жыл бұрын
The inrush on both meters seem to be specked the same.
@HVACGUY2 жыл бұрын
You’re right. Shannon’s comments at the top explain why I was not getting the desired results
@fernandofhernandez8992 жыл бұрын
weakest point on those Fieldpiece meters, is the Selector Knob, those break, i have two broken FP meters , have seen other techs using theirs turning the selector with a Flat screwdriver, just not me to do that, reason for me in replacing them wit TESTO 770-3, same with Sman Gauges have three of those leak ...that they took care and replace em, but also got myself the Testo set instead which also i like em more than FP
@tonyrhoton6613 Жыл бұрын
480 will get u thru 99 percent of jobs its small size is good 4 tool bag
@joemartinez-6739 ай бұрын
Thank you 🤟😎
@HVACTechKnowledgy2 жыл бұрын
Nice review - thanks! I would have never considered that magnet issue....I would have thought the smaller 480 would have held up stronger. I'm definitely enjoying my 680 for the second try. What happened to your first 680? I know you mentioned in your video this was your second one.
@HVACGUY2 жыл бұрын
The inrush button quit working. Fieldpiece replaced it immediately though.
@roberttruesdell61518 ай бұрын
lol your supposed to flip the strap out to use the magnet so it doesn’t flop over.
@BridgeWater94 Жыл бұрын
I know your a busy guy but a great video idea would be simply walking through each feature of this sc680 and saying what you use it for. The manual for this thing is garbage and doesn’t really tell you how it’s better then it’s cheaper alternatives imo.