HVACR Training: How To Wire RANCO Electronic Temperature Control (RANCO ETC111000-000 Wiring)

  Рет қаралды 3,823

Jumper man Tech

Jumper man Tech

Күн бұрын

Пікірлер: 15
@zekenzy6486
@zekenzy6486 9 ай бұрын
Great Video. Thank you for sharing. I'm waiting for watch next video. Have a nice week.
@brandoncorrea511
@brandoncorrea511 9 ай бұрын
Alright can’t wait for the troubleshooting
@sherwinalvarez7365
@sherwinalvarez7365 9 ай бұрын
Or... Or adding a Grasslin 115V or DTAV40.
@stevencossaboon3237
@stevencossaboon3237 9 ай бұрын
Nice work Jumper man. Thank you
@billyhorton5779
@billyhorton5779 9 ай бұрын
Good stuff, thanks JMT!
@briancarlisi2224
@briancarlisi2224 9 ай бұрын
One question is on your last example wired for 120v you showed the orange jumper from 120 to the C terminal with the yellow from the NC terminal to the solenoid. I’m confused about the red coming from C (where the orange jumper terminates) but where does the red terminate? The diagram didn’t show a second wire coming from C. What am I not understanding? Thanks for taking the time to explain.
@barrybroderick5103
@barrybroderick5103 9 ай бұрын
Was wondering the same , I don’t think there should of been a second wire coming out of the c terminal in both examples 🤷🏻‍♂️ as per the diagram
@kennethlobo4420
@kennethlobo4420 9 ай бұрын
Thank U jumper man Tech
@nicolerennie
@nicolerennie 9 ай бұрын
love these training vids!
@harrydickson4575
@harrydickson4575 9 ай бұрын
Awesome 👍👍👍
@artdacunha11
@artdacunha11 7 ай бұрын
HVAC student here from Canada. How would you connect this to a defrost timer? ..or is it odd to wire it up with a defrost timer?
@youtderek
@youtderek 6 ай бұрын
This would be wired on the NC portion of the defrost timer. So when the defrost timer is not in a defrost cycle, it is supplying voltage to this thermostat. When the box temp rises above the thermostat setpoint it will open the solenoid and allow refrigerant from the receiver to feed the evaporator. Once the evaporator picks up enough heat, the liquid refrigerant is boiled to a gas and the low side pressure (back pressure rises). On a separate circuit is the low pressure switch, once the low side pressure exceeds the setpoint of the low pressure switch, it activates the compressor and the refrigeration cycle begins. Once the box temp reaches below the setpoint of the thermostat, the thermostat no longer energizes the solenoid and refrigerant is no longer fed to the evaporator. The low pressure switch continues to energize the compressor until it reaches its low pressure setpoint (usually around 5psi) and the refrigerant is pumped into the receiver (aka pumpdown).
@artdacunha11
@artdacunha11 6 ай бұрын
thanks for the reply, I appreciate it!
@Herewegoagain797
@Herewegoagain797 9 ай бұрын
Looks like according to his schematic, he ran the N back to the Common on the bottom contact instead of back to the Neutral side of the load. Could use some clarification on that cause it looks like he would just be shorting the contacts by sending N back to its hot side.
@ILoveKittys78
@ILoveKittys78 9 ай бұрын
😻💚💜💚
这是自救的好办法 #路飞#海贼王
00:43
路飞与唐舞桐
Рет қаралды 90 МЛН
龟兔赛跑:好可爱的小乌龟#short #angel #clown
01:00
Super Beauty team
Рет қаралды 111 МЛН
Random Emoji Beatbox Challenge #beatbox #tiktok
00:47
BeatboxJCOP
Рет қаралды 45 МЛН
CONTROLES DE TEMPERATURA FUNCIONES BASICAS PARTE 2
25:46
ultra-kold Refrigeracion
Рет қаралды 3,1 М.
Ranco single stage controller setup
2:09
MoreBeer!
Рет қаралды 59 М.
I Travelled 20 Hours to Go Tool Shopping in Japan
16:08
Scott Brown Carpentry
Рет қаралды 74 М.
How to wire a Ranco ETC 111000 Digital Temperature Controller
1:33
这是自救的好办法 #路飞#海贼王
00:43
路飞与唐舞桐
Рет қаралды 90 МЛН