Discussing Ducts Types and Tips

  Рет қаралды 88,937

HVAC School

HVAC School

Күн бұрын

Пікірлер: 85
@grashoprsmith
@grashoprsmith 2 жыл бұрын
I appreciate the tips. I love adding more knowledge to my arsenal.
@treyfranklin6092
@treyfranklin6092 2 жыл бұрын
Such a legend... When I first started in the trade I credit a lot of what I know to this guy, and to this day he's still putting out great content. Thank you Brian!
@naughtiusmaximus1811
@naughtiusmaximus1811 2 жыл бұрын
Emin HVAC hasn't posted in years but his channel is awesome for the commercial side.
@realSamAndrew
@realSamAndrew 2 жыл бұрын
It's Bryan with a y 😉
@jericosha2842
@jericosha2842 2 жыл бұрын
@@naughtiusmaximus1811 thanks, was wanting to expand my knowledge base
@amohvac27
@amohvac27 2 жыл бұрын
How long have you been in the trade?
@danroot84
@danroot84 2 жыл бұрын
This should be mandatory viewing for all HVAC people. I’m about to go repair a bunch of trunk line leaks by using alcohol and tape and mastic and this video just added days to my job because I can’t unsee all the bends and touch points of duct on trusses. I will happily be resolving all these issues knowing that I did them right, once, and never have to deal with them again. Thank you.
@HVACguy1911
@HVACguy1911 Жыл бұрын
Yeah everytime I see ducts through truces I cringe and pull out the hanging strap
@MAGAMAN
@MAGAMAN Жыл бұрын
This channel is great. I'm trying to improve my airflow and reduce my air leakage from the homeowner-done hvac job and I have learned a ton. Unfortunately, most of my flex duct is resting on the joists in my attic and I'm not sure there is enough slack to lift it off the joists, but I'm going to try. If that doesn't work, I may be replacing all the ducting as time and money allows.
@cyrilasfrenchyaz
@cyrilasfrenchyaz 2 жыл бұрын
Thank you for this great video! When I added straps to my ducts, I put a sleeve underneath the ducts made from cardboard to avoid compression and kinks. Also for each boot, I added some Malco FDS1- Flexible Duct Support to keep a nice curve from the floor. They can be used as well if you have some ducts leaving the plenum at an angle. Also, if the attic has already a radiant barrier, it doesn't matter if your ducts are black or silver, something to consider. While ducts are part of the system, sealing and insulating the plenum is something to do to help against air leaks and temperature swing.
@DonTruman
@DonTruman Жыл бұрын
Appreciate the lesson. I'm just a homeowner, but trying to get educated on how to improve my home's energy efficiency, to lower my painfully increasing electric and gas bills. Seems my situation is different because my A/C and ductwork in all in the basement and it's a conditioned space, therefore leaks and condensation probably aren't as much of a factor as they are as when it's all up in a hot humid unconditioned attic. Still, I can use these techniques for optimizing the system.
@CurtisWhitehead-wn5bs
@CurtisWhitehead-wn5bs 6 ай бұрын
This is mad helpful for me. Answered a few questions that I had.
@muhammadusamakhan5295
@muhammadusamakhan5295 2 жыл бұрын
Nice lecture on conduction convection and exhaustion
@tealkerberus748
@tealkerberus748 11 ай бұрын
Not planning to have any flexible ductwork in my build, and mostly planning the ducts for ventilation because my next home will be in a region that doesn't need much cooling. But best practice is never wasted!
@bikerbobcat
@bikerbobcat 2 жыл бұрын
Very informative as always. Good tips about silver/black duct and best ways to make connections. Really wish there was more about different types than just flex but still good video. I know you have to keep to your market.
@grotowin
@grotowin 6 ай бұрын
I have a question, on round metal duct work return air systems, specifically adjacent pipe connection, does the return air duct have to follow IRC Duct Lap rule. I understand the Supply air needs to follow this principle, but does the return air branch duct connections need to follow this rule as well?
@larainewoodruff3739
@larainewoodruff3739 6 сағат бұрын
What about ducting that’s under the house?
@coldfinger459sub0
@coldfinger459sub0 2 жыл бұрын
I don’t normally do ductwork try to avoid it. But as usual when I watch one of your videos I learn something.
@mattc6532
@mattc6532 Жыл бұрын
I bought a house in 2022. The hvac hadn't been updated since house was built in 1996. The ducts had stinky mold so we decided to have new hvac and all ductwork replaced. Hvac system and box shaped sheet metal duct (with insulation inside) trunklines were in crawlspace with flex ducts running off metal trunk line. We had a small company replace all ducts and complete system. I was kinda surprised after install when I noticed they didn't use any sheetmetal ducts at all... only flex ducts for the entire system... Is that normal? Anything wrong with using all flex ducts to replace old metal trunk line?
@joeshearer1247
@joeshearer1247 2 жыл бұрын
Hey have you ever tested wrapping one pass of mastic tape around the collar which has a little “give” and will act as a seal - and then use the panduit strap which should compress down into the mastic tape. I think I would rather do that then play with mastic inside the collar
@caru3257
@caru3257 2 жыл бұрын
I hate to remove it later
@jaysonhines1
@jaysonhines1 2 жыл бұрын
Yes, I love installing it that way Joe
@samuelsech2278
@samuelsech2278 2 жыл бұрын
That's how I do it
@brianmcdermott1718
@brianmcdermott1718 2 жыл бұрын
Great points Bryan. Thank you.
@fadiabboud9111
@fadiabboud9111 5 ай бұрын
🤔 black vs silver flex. Are you referring to the inside afyer insulation or outside before insulation
@wstt4
@wstt4 10 ай бұрын
How do I know the maximum airflow, CFM, that can be handled by some 6” flex duct I have in my attic, if I put in a booster fan to be able to increase aire flow at certain times? The duct says 4000 FPM maximum, it’s 6” duct and I’ve got about 15’ of duct run before the booster fan and then 15’ after The dan to the vent? Thanks in advance for any help on this.
@famousdude1239
@famousdude1239 2 жыл бұрын
Black flex duct in the attic is "less efficient" in the cooling season, but black flex duct in the attic is "more efficient" in the heating season. Correct? What ACCA approved J-manual software addresses the flex duct covering color, which then includes its heat gains or losses?
@guerrrero1978
@guerrrero1978 Жыл бұрын
hello, can duct asbest be replacing for flexible duct??
@MDuckett9229
@MDuckett9229 2 жыл бұрын
Love the channel👍👍👍 Learned slot watching yall !!! Keep up the great work
@lanceroot520
@lanceroot520 7 ай бұрын
I think you're ready for Ivy League HVAC instruction! Great video!
@KiwiBrowne
@KiwiBrowne 11 ай бұрын
I need to tape up the hole in the top of my furnace which was cut to put the air duct in which goes up into the ceiling and outside. What should I use to tape it up? The duct gets hot. Thank you.
@shinigami2265
@shinigami2265 11 ай бұрын
Use 367 tape it
@shinigami2265
@shinigami2265 11 ай бұрын
And sheet metal
@BrStu-t3l
@BrStu-t3l 10 ай бұрын
If you look closely at the foil you will see good flex has reinforced string every 1/4" instead of every 1/2" that some manufacturers use. Reduces rips when moving it around during installation.
@warenmann1042
@warenmann1042 2 жыл бұрын
So, black flex is less likely to sweat in an attic, seems like it does have a silver lining...
@jericosha2842
@jericosha2842 2 жыл бұрын
I see what you did there
@MrCswan
@MrCswan 2 жыл бұрын
Awesome training. I’d love to see a tutorial for 4 piecing duct board
@robertpeters9438
@robertpeters9438 2 жыл бұрын
How often do flex ducts have to be cleaned with heppa filter
@marcycami
@marcycami 2 жыл бұрын
what are your thoughts of the Rheia system in Florida?
@realSamAndrew
@realSamAndrew 2 жыл бұрын
I don't know, but Rhea Seahorn is great in Better Call Saul.
@RjsEpicAdventures
@RjsEpicAdventures 2 жыл бұрын
Very informative such a great teacher
@jmacorda5786
@jmacorda5786 2 жыл бұрын
Sir how can enroll with your school I want also to learn more about HVAC
@mannyg35
@mannyg35 Жыл бұрын
Good information, thanks
@Gabriel-vz7ml
@Gabriel-vz7ml 2 жыл бұрын
Thank you!
@RickSegui
@RickSegui 2 жыл бұрын
Why would anyone purposely install a unit into a very hot attic (140/150 F) and expect it to be efficient? System spec’s are most likely being violated! Please explain without sarcasm. Thanks!
@bikerbobcat
@bikerbobcat 2 жыл бұрын
Retrofits and remodels. Here in the DC/Baltimore area, brick rowhouses have this all the time, especially high velocity units. It opens the floor/wall space that a closet air handler/furnace takes up. Flippers are mostly about profits more than efficiency. In detached new builds around here with bigger, more open truss attics, that system is usually just for the upper floor zone so any efficiency comes from it not having to condition the entire house, only up there.
@joewilburn2537
@joewilburn2537 2 жыл бұрын
Why should you not use silver duct under a manufactured home?
@jericosha2842
@jericosha2842 2 жыл бұрын
Pretty sure the black stuff for trailers are thicker material that can lay against water and the ground. Silver stuff is more easily torn through by critters and tears more easily when laying against the ground.
@martinmcquaide4807
@martinmcquaide4807 2 жыл бұрын
I never like F/G ductwork. Maybe for a very small systems. I like wrapped metal. In a basement use ridged pipe, then wrapped.
@TheBullboy1
@TheBullboy1 2 жыл бұрын
Great job
@aliyusuf7713
@aliyusuf7713 2 жыл бұрын
Thanks for you work
@channelcatchaser9426
@channelcatchaser9426 2 жыл бұрын
Great content
@martinmcquaide4807
@martinmcquaide4807 2 жыл бұрын
Northeast, land of crawlspace and damp basements. Literally rains off the insulation blanket. Ruins F/G wrap. I love the foil bubble wrap. Now a growing business is crawlspace incapsulation, sealed with dehumidifiers. You can smell the difference in new homes with a incapsulation system installed over homes just a few years old without them sealed and conditioned.
@Sam9wilson9
@Sam9wilson9 11 ай бұрын
Thanks!
@latayknight7788
@latayknight7788 2 жыл бұрын
Thank you
@thecrossroadstavern1447
@thecrossroadstavern1447 2 жыл бұрын
I literally clapped when I heard you say flexduct should only be used for straight runs.
@Respect.The.Grind..
@Respect.The.Grind.. 2 жыл бұрын
Yea nobody does that in the northwest lol. Crazy bends and runs with flex in attics. Kinks all over the place is the norm.
@brianlittle717
@brianlittle717 8 ай бұрын
Bypass dampers for zone systems will make it sweat. I never use bypass dampers.
@HairSandwichTV
@HairSandwichTV 2 жыл бұрын
I couldn't tell if he said Problem Attic or problematic. Both are synonymous lol
@paulgaras2606
@paulgaras2606 2 жыл бұрын
Thank the lord for sheet metal in basements
@richardwagner4668
@richardwagner4668 2 жыл бұрын
Metal ducts are the only way to go, which I found out the hard. First I had flexible ducts installed and they off gassed so bad it made my nose burn severely. After several months of this I concluded it would never end and had it taken out and metal put in. What a financial nightmare.
@joshuaseaton4526
@joshuaseaton4526 2 жыл бұрын
I'm hoping someday (probably after I retire), it will be code to have all ducting within the thermal envelope.
@R6Wick
@R6Wick 2 жыл бұрын
Time stamps would be good
@HVACS
@HVACS 2 жыл бұрын
Time Stamps added!
@GONZOFAM7
@GONZOFAM7 4 ай бұрын
Man I looked in my attic and I saw every "don't " up there.
@tahernabieh6096
@tahernabieh6096 6 ай бұрын
black steel connections
@Workstupidyoutub1000
@Workstupidyoutub1000 Жыл бұрын
👍🏻
@a3agnello
@a3agnello Жыл бұрын
All due respect if you use a panduit gun on the inner and outer it’s not leaking at all….I realize the codes vary in certain markets but if you use a gun properly there’s no way
@rodgraff1782
@rodgraff1782 Жыл бұрын
I agree
@jericosha2842
@jericosha2842 2 жыл бұрын
You mean the HVAC guru himself isn't using concrete duct collars? What they heck man, I'm disappointed.
@jmacorda5786
@jmacorda5786 2 жыл бұрын
I hope you recognize me sir
@rodgraff1782
@rodgraff1782 Жыл бұрын
Flex is all garbage, and is even illegal in some areas. Better not put it under a skylight,because it will blow apart from degrading in the sun. I. Have had numerous calls where rats chewed thru the stuff and peed and pooped inside it. Metal duct is the only way to go. But of course, sadly, standards have changed. Flex duct was designed to be used for short connections to the diffusers. A properly used set of panduit straps is superior, but you have to use the tool to tension them properly. They won’t fall off if you use a collar with a bead. Just examine the labor difference. Two straps, liner and outer jacket, then a wrap of insulation over the top. All that fussing over mastic, tape, etc, etc to seal an inferior duct product just doesn’t make sense. I’m not trashing the instructor here, I think he is great. I am trashing flex duct though, I’ll have to admit.
@johnnygarcia7386
@johnnygarcia7386 2 жыл бұрын
#THEREALHVACMASTER
@Gary-ts6dh
@Gary-ts6dh 2 жыл бұрын
11:21 - A problematic addict in a problem attic (say _that_ three times fast!)
@ericmixer
@ericmixer Жыл бұрын
He would get fired his first day at work , you cant do a lot of what he is advising to do !
@chadwright2024
@chadwright2024 2 жыл бұрын
lots of wanna be comedians in the class
Duct Design for Great Results w/ Ed Janowiak (ACCA)
2:11:16
HVAC School
Рет қаралды 157 М.
Stop Sweaty Ducts, Vents and Systems
23:26
HVAC School
Рет қаралды 274 М.
Try this prank with your friends 😂 @karina-kola
00:18
Andrey Grechka
Рет қаралды 9 МЛН
BAYGUYSTAN | 1 СЕРИЯ | bayGUYS
36:55
bayGUYS
Рет қаралды 1,9 МЛН
So Cute 🥰 who is better?
00:15
dednahype
Рет қаралды 19 МЛН
Better Duct Installation Practices - Kalos Meeting
24:13
HVAC School
Рет қаралды 123 М.
Sizing Ductwork THE CORRECT WAY
1:04:47
SandwellMechanical
Рет қаралды 156 М.
HVAC Ductwork BEST Practices Using SHURTAPE | Part 2
17:42
Quality HVACR
Рет қаралды 133 М.
Flex vs. Metal vs. Duct Board: Differences and Use Cases
5:35
Matt Risinger
Рет қаралды 93 М.
THIS is Why Your Heat Bill is So High
18:21
Home RenoVision DIY
Рет қаралды 2,6 МЛН
IAQ - Humidity and Moisture Control
1:03:03
HVAC School
Рет қаралды 5 М.
How To: Fabricate A Plenum Box With BASIC Hand Tools | HVAC Ductwork
15:54
sizing ductwork, quick and easy shortcut
13:47
Able Distributors - Your HVAC Solutions Delivered!
Рет қаралды 104 М.