I reckon that the owner did all or most of that. He’s so keen that he has a list of circuits etc. and made up that board outside. 😵💫😵💫😵💫
@matthewking84682 жыл бұрын
“It’s failed I’m afraid. Full new install required. No sorry I’m too busy. Thanks, bye”
@schmuuth_dot_com32022 жыл бұрын
Yeah well, that's not an EICR - although it is what many NICEIC and NAPIT yokes do. Feel free not to accept a job - if you accept a job do a freaking EICR as per the guidance. Jeez
@TooMuchInfoSir2 жыл бұрын
This client reminds me of me, definitely works in I.T (infrastructure) OLED, Synology, Ubiquity 👌 - Shame the electrics are bad, but your in there now so right direction haha
@JBE2 жыл бұрын
Lee and Luke, you guys deserve a medal for this one! What a job doing an EICR on all that nonsense 👏 👌🏻
@tobysherring13692 жыл бұрын
re metal box in loft - simple to replace with a CU relocation kit with DIN rail. Often they are put in plastic boxes - so a metal one would be an improvement. Grommets are fine if you can't get a finger in, and through crimps if done properly are perfectly acceptable. If you don't know where to start: switchfuse and sort tails, FCU for tumble dryer, screw kitchen switch board to wall, inspect and test the outdoor kitchen circuit, rewire bell transformer, sort loft and garage jumble of cables. You know you're replacing the DBs.
@NickChristy2 жыл бұрын
Couldn’t Of said it better
@ConanRider Жыл бұрын
You could probably pay for a rewire just by scrapping all that copper
@funkpop-l8o Жыл бұрын
Math isn't mathing 😂 it may get you like 25-50 percent not counting in labour (sadly)
@dannycrooks84622 жыл бұрын
I seen a job a while ago that was done by a so called professional company it was disgraceful worse than an amateur job you can't blame it all on DIY jobs
@AndyHobson2 жыл бұрын
It's the easiest thing to go "looks like a DIY job" yet they've even had on their channel amazing DIY jobs so it's a bit harsh. There's absolutely loads of crap trades in all trades out there. They're there for money not passion. Fortunately these guys are top notch so doesn't matter who did it, they do a great job 👍🏼
@therealdojj2 жыл бұрын
starting at the beginning normally helps lol
@Tryingtimes0072 жыл бұрын
Why is it always a failed (DIY) project? you might have all the qualifications required it doesn’t mean you’ll be any good, conscientiousness is what’s needed 👍
@carlmarquardt9942 жыл бұрын
TOTALLY AGREE
@yrification2 жыл бұрын
I've seen bad work by so called electricians and then bad DIY electrical work. you can tell when its DIY. another give away is if the home owner gives you details in drips and drabs, its a massive red flag. DIY work shouldn't be allowed outside of restricted minor works.
@Alan.Moffat2 жыл бұрын
That might have been a DIY project...... but explain the rest of that garbage 🤣 it was defo one of yous sparks 🤣😂
@AndyHobson2 жыл бұрын
Yeah agree with this, it's usually a crap spark in my experience
@yrification2 жыл бұрын
@@Alan.Moffat people cheap out on electrical work but pay a plumber £1000 labour fit a boiler 🤷🏻♂️
@ianbird69972 жыл бұрын
I am not an electrician and even that stinks of DIY to me 😂 glad they have the A Team on the job 👍👍👍👍
@makg46552 жыл бұрын
Day 2 and 2 men . Wow must be charging a fortune for an EICR. Lucky to get £200 these days esp with all the IN THE VAN TESTERS these days .
@grahamnicholson15532 жыл бұрын
Would love to see a summary of the full report and the C1 rated items. There was a lot and it was overall messy/confusing but only thing I saw very bad were the long tails without fused protection. Maybe the extension box was missing some grommets and in a plastic box but through crimp weren't awful. This is definitely not the worst EICR we have seen on the channel but it is exacerbated by a big board and number of circuits.
@chriscollins17042 жыл бұрын
Mouse scarer? Some people are insane 😄
@artisanelectrics2 жыл бұрын
Study Stickers! The best looking electrical textbook modification in the game - Get 10% off when you use our discount code "Artisan" at checkout here - bit.ly/3uY94dW-StudyStickers Fancy getting 100% off Study Stickers why not enter the Artisan/Study Stickers giveaway! We have 5 complete bundles to give away so head over to our Instagram to find out how to enter! 📕instagram.com/artisanelectrics/
@connect4king2 жыл бұрын
rewire or walk😬
@carlmarquardt9942 жыл бұрын
Pretty much
@goober-ll1wx Жыл бұрын
Ho Lee Ferk some people live in ticking timebombs...
@Wintersky1362 жыл бұрын
I tell you what I would do: Install a proper large distribution board and rewire the cables in there… those „play time“ consumer boards need to go
@adamsmithelec2 жыл бұрын
Size of those kitchen cabinet handles!
@Mark-xr4zt2 жыл бұрын
Definately separate the two circuits onto their own breakers. It is one were it is hard to justify any other approach yo be honest. If for any reason they couldn’t be then you should design for the 0.4 disconnection time for both points of utilisation.
@peterc32282 жыл бұрын
You could put the lights on a fused spur, drop it down to a 3amp fuse. If they don't want to replace the cables
@Mark-xr4zt2 жыл бұрын
@@peterc3228 I probably would shy away from that as there were MCBs installed downstream for the outdoor lighting controls in the IP wall-mounted box, so selectivity would be a possible issue. However, from the limited info, we get on KZbin videos either might be a better solution 😀
@peterc32282 жыл бұрын
Definitely agree separating the two circuits would be the best option. Sorry didn't give any detail where to fit the fused spur. I was thinking to replace the mcbs in the ip box with a fused spur /spurs, and dropped down to a 3amp fuse at that point. Or some manufacturers do a 3amp mcb, if compatible you could swap them out. Even then before touching anything, you would still have the fun job of tracing the whole run of cable back to the board looking for joint boxes where the csa of the cables might change affecting the upstream protection. All the best, Pete 👍 😊
@johnwinters42012 жыл бұрын
The light fitting just dangling from a bit of wire is standard installation in France.
@countesscable Жыл бұрын
This is true! I regularly stay in France and just about everything electrical is loose, wobbly or dangling.
@JensenPGATourDriven2 жыл бұрын
Great content guys & Definitely Awful electric , you can’t believe what you come across, & Yes it would be a good job for Ruben on the junction box to Make safe!! Don’t understand How Someone has done this as electrician, Your work should be A1 and most of all safe !! Well done Luke going that extra mile on the plug behind the TV. Cool !! ⚡️👊
@bells19692 жыл бұрын
Great vid lads what volt stick are you using the green and red led one 👍
@arishem5552 жыл бұрын
the first thing which every construction team should do whenever they arrived: scream "who the heck did all that mess whooooooa" :-D
@rouman72 жыл бұрын
Jeez what a mess the time you spend , fixing all that , I’ll recommend a rewire .. defo a handyman’s work …
@nailgunnercolbeck4 ай бұрын
But it works! 🤔 YES IT WORKS! UNTIL IT DOESN'T!! and the consequences are irreversible! Don't people understand that the regulations change all the time and are there to keep people safe! You guys deserve a medal. Keep up the awesome work 💪💫
@tobysherring13692 жыл бұрын
re 20A radial to garage: 1. no need for board in shed - FCU with 5A fuse for lighting, 20A DP switch to isolate sockets. 2. Outdoor lighting FCU 5A in outdoor box (or put in garage when you split the 20A circuit). 3. Split circuit in garage as now with new terminations and either a 2-circuit CU (OTT in my opinion) or just a FCU for outdoor lighting (metalclad would give you a good box to run armoured from).
@jasonbowe97672 жыл бұрын
These are absolutely nightmare jobs for professional electricians, I feel like crying just watching this 😫
@cbcdesign0012 жыл бұрын
Why would you cry? Its not your house and potentially its work, nothing to cry about.
@jasonbowe97672 жыл бұрын
@@cbcdesign001 I just wanna 😏
@KizakiAyato5 ай бұрын
You are way over reacting
@Shanky_TH9540Ай бұрын
ridiculous over reaction lol
@mitch322 жыл бұрын
I would be quoting a rewire. I don't think it would take that much longer than trying to fix everything. Also I wouldn't want my name evolved with that mess despite how many photos I took prior. Good luck boys
@wizard3z8682 жыл бұрын
That place reminds me of a lot of old 1920's wiring systems of the knob & tube era I've seen in new England USA right down to old service panel as a mess of a j box lol
@richarddavis43782 жыл бұрын
Looks like my loft, I think the previous owner was technically very clever, but very sloppy with his wiring. We have boxes with electronics controlling 12v lights, and sensors everywhere. It's a headache working it all out. I'm not a sparky, but have a good understanding of normal domestic electrics.
@Kalus_Saxon Жыл бұрын
Why you shouldn’t let your cousin Bazjinder from deli wire up your house… 😂
@Damientrades2 жыл бұрын
To.many ads bro had to give up watching 👎👎 to money hungry Jordan
@pgood72662 жыл бұрын
Do electricans in the UK ever get shocked? Seems like you guys don’t really work on anything live from what I’ve seen
@nk600016 күн бұрын
Did this customer end up getting all the extra work done after the inspection?
@diegovd72152 жыл бұрын
I could feel your pain! Bon courage ! :)
@rayg62242 жыл бұрын
You guys do a great job. I'm in Virginia and wondering when and why an EICR is needed? Have a great day!
@TheOmegaRiddler2 жыл бұрын
They have a video explaining why they need to do EICRs if you want to look on their channel.
@AS192832 жыл бұрын
I’m uk based but worked in Oregon. To my knowledge the US doesn’t do any routine testing whatsoever. More physical inspections and building permits etc.
@davidmell17892 жыл бұрын
If a property is rented out, it is required to have an up-to-date EICR by law. In addition, when a property is sold and a mortgage is being used to fund the purchase, the mortgage company's surveyor/valuer will often recommend an EICR is undertaken.
@rayg62242 жыл бұрын
@@davidmell1789 thank you. We have a home inspection at time of sale, but they aren't that extensive.
@joanofarc708 Жыл бұрын
No wonder the previous electrician didn't come back ffs
@Alan.Moffat2 жыл бұрын
That mess appeals to my ocd..... I'd love to get stuck in about that!!!
@calvinford34982 жыл бұрын
rewire throughout for me wouldn't trust any of the eclectic's there even though its beet tasted
@charlfourie8184 Жыл бұрын
Did you fix everything? And wheres the video on that end result?
@samuelseviour89442 жыл бұрын
I'm sorry, I could not watch it all as my eyes and brain were melting
@HATCHETHAS2 жыл бұрын
Lots of DIY stuff there but those 2 fuseboards and extended bodge in the loft smells of a dodgy spark.
@mistymick49052 жыл бұрын
Mate, You had me squirming all the way through. You both have the patience of a saints. That loft is something else. That won’t be a quick fix.
@michaelsglas2 жыл бұрын
Well said Ruben. College or University really don’t teach you what you do when you’re in the field. I’ve experienced that myself. Electrical should have a balance to how it’s being thought. Too much theory and not enough practical
@Dazzy842 жыл бұрын
At last!! Someone who actually speaks sense. Teacher might tell you how to wire a plug etc, but are they actually making you wire one??
@joanofarc708 Жыл бұрын
It takes more 3 months to become competent electrician it takes 4 years
@peter6411 Жыл бұрын
If I brought that house I'd have you guys in to fully re-wire the whole lot, I'm no electrician guys, but to me it's a fire waiting to happen... Love the videos you all take care. Peter
@wolvolad25 Жыл бұрын
I think walkie talkie’s would be a good idea
@tpottrell2 жыл бұрын
Wont a double board get clouted by the door?
@nigellewis8042 жыл бұрын
The cost of qualified electrician Is prohibitiv to most people diy will never stop
@nigellewis8042 жыл бұрын
All the people we see them work with are high end client s When most people struggle to put food on table re wiring is last thing on there mines so are electric cars
@lewis94uk2 жыл бұрын
Most houses if built/rewired(properly) from the 70s are fine cabling wise just will need a board change most people can afford that if people want 20 downlights in their kitchen they should either do without or pay somebody to do it properly.
@robertburrows66122 жыл бұрын
Unless they agree to a full rewire it's a job I would walk away from it , leaving a letter that the full installation is dangerous and should not be used to cover my arse
@SpNick32 жыл бұрын
I’m not electrician enough to do this job, I’ll for sure run away from this job.
@RetiredandLivingthedream2 жыл бұрын
I had my own Electrical business when I lived in the U.K. Living in Thailand now the standard of Electrical work is way way lower than the U.K. Standards. Well done I still love watching these Electrical videos.
@artisanelectrics2 жыл бұрын
Thanks
@OldLordSpeedy2 жыл бұрын
Hmm ... yeah Thailand was never an U.K. colony, but Hongkong, Australia, Philippines, some small island. But only U.K. mainland have so a high standard where no power accidents happend since power lines are born. The standard in the Kingdom of Thailand isn't high but okay. Most foreigners customers want have standard German wall sockets expect the U.K. customer - only U.K. wall sockets. The standard thai wall socket is designed for max. 10 Ampere only. Same the standard CU. But do you can import European technology without problems - Krung Thep city is an international trade cross. Funny are the build-in sockets and lamps, but they put cable direct on the wall. Outside meter normally but I let build a small higher house for them. Good if have flash flood or monsoon here.
@owenbailey54972 жыл бұрын
Hi mate can we borrow Ruben next week
@Jay3692 жыл бұрын
I can C2 that this job is 🤢🤮
@alsanova2 жыл бұрын
This give me a headache. 🤯 What a hot mess! I hope it not just CU change but tidying up all the hot messes, that including loose cables in the loft.
@iantaylor68589 ай бұрын
Go to India!
@kkaiW2 жыл бұрын
hey what g shock are you wearing ? I’m wanting a new gshock and wanna know if it’s good or not. Great video too
@AndrewLumsden Жыл бұрын
That's a can of worms being fed with a tin of spaghetti!! 😂
@hjkglpojh18632 жыл бұрын
13:08 There is NYM cable going out the bottom of the box which is not rated for being in the Dirt not even if it is in Conduit.
@lightecelectricsltd56592 жыл бұрын
take it easy guys it will be fixed by professionals in the end, it becomes a beautiful memory
@stevelawrence71112 жыл бұрын
And that's the stuff you can see
@djquick2 жыл бұрын
Wow… wiring is done much differently there vs here in the US.
@nathanjp962 жыл бұрын
Wow! Rewire? 👍
@bobturner36452 жыл бұрын
What is the model type of the voltage stick being used in this video?
@ConstantijnKool2 жыл бұрын
I want to know that too!
@Mark-xr4zt2 жыл бұрын
They used two. The yellow one was a Fluke and the grey one Lee was using is made by Megger.
@daron89822 жыл бұрын
Kewtech
@inspiringengineer2 жыл бұрын
Wish my work was that good! ;)
@GrenPara2 жыл бұрын
Great Video Thanks for making it. I have a question. When you do testing what is the cable reel you use sometimes? And where can it be purchased?
@daron89822 жыл бұрын
its called R1+R2 lead or wandering lead and its used to test bonding cables. they come in 10, 25, 50 metres length. can be purchased from screwfix, toolstation, etc. at screwfix they have kewtech
@danielelise73482 жыл бұрын
It's a complete sh!tstorm all round,rip it ALL out.
@stenningelectrical12052 жыл бұрын
Scerwfix sparky been there !!😂😂😂
@GaryB19802 жыл бұрын
First video I’ve had anxiety watching 😂.
@DanAuty2 жыл бұрын
7:47 - CAN ANYONE ELSE HERE LEE DO A MASSIVE FART 🤣🤣
@philldaly2510 Жыл бұрын
snakes wedding mate
@TheLastSock2 жыл бұрын
I dont normally do advertising but bizarrely your advert for these stickers was exactly what i have been looking for excellent. I just need to sort out an issue at home now, Heres a question for you, two 30A MCB's (both radial) one is for the cooker & hob, the other is Washing M/C and Dish washer. Both work ok independently, but if I have both on, the RCD trips instantly , any ideas? the RCD doesnt trip if they are on one at a time, when all the other MCB's are off the two being switched on still trip the RCD.
@corymac2 жыл бұрын
That’s most likely a borrowed or mixed up neutral. Are both the MCB’s on the same RCD?
@artisanelectrics2 жыл бұрын
Glad it helped!
@Doyley-is9qq2 жыл бұрын
A lot of modern appliances have quite bad earth leakage due to the electronics inside nowadays. That might not be the case but I feel like if it were a nicked cable such as a screw into a line or neutral cables’ insulation, the RCD would be tripping immediately as soon as you turn on that particular circuit. I also wouldn’t expect it to be a borrowed neutral because that is very rare on anything other than a lighting circuit which was wired before RCDs were being used. The best option to rectify would be to replace the MCBs for RCBOs
@carguillo12 жыл бұрын
NO THATS IS A TYPICAL ELECTRICIAN WORK
@lewisross40442 жыл бұрын
Genuine question. Apart from the fact that you can't disconnect or isolate the appliance easily, why would the tumble drier need to be fused down if that's all that's on the end of the cable? You've got a fixed load with a cable that's designed to take that amperage. Surely if the PFC is high enough it should be fine?
@david292622 жыл бұрын
Because if it fails it will draw more and potentially cause the cable to heat up and catch fire
@lewisross40442 жыл бұрын
Not sure I agree but okay.
@Gazzerdaman Жыл бұрын
It's not though, the cable feeding the appliance is rated for 13amp. If you got a dead short or other fault in the tumble dryer the flex could be subjected to much more than it's rated capacity. It would then melt and potentially start a fire. Plug top fuses are designed to protect the appliance flex.
@mcneillmoss Жыл бұрын
top work
@LJ_DESIGNS2 жыл бұрын
Looking for an apprentice?
@tiarnanclifford88572 жыл бұрын
does anybody know the name of the Voltage Tester Pen that Lee was using with the flashlight on it? really want one now
@daron89822 жыл бұрын
Kewtech but any voltstick will do
@scotty2hottyltd2 жыл бұрын
Think it’s actually a Meggar. Most of their test kit is Meggar
@RichardArblaster2 жыл бұрын
Great video guys 😎
@altubury2 жыл бұрын
Serious question now guys, how do you justify a “day two” on an EICR? Dont get me wrong, its lovely work if you can get that, but to be competitive, who agress to pay two days wages for two guys just for an EICR? I love the videos, perhaps you can give us the secret of how to get customers to pay so much for what is essentially a 100% failed installation? :-)
@samgriffiths76092 жыл бұрын
They’re obviously careful in their pricing. Probably went to have a look first and saw that it wasn’t going to be a quick job. With jobs like these you’ve got to think of the eicr as more of a business opportunity rather than just an legality. Clearly going to be a lot of remedials and if you can be seen giving them a detailed (yet comprehensive) report of the remedials required, chances are the customer will go with you to rectify things.
@altubury2 жыл бұрын
@@samgriffiths7609 Thanks for the helpful reply 👍🏼
@schmuuth_dot_com32022 жыл бұрын
You might typically price per circuit and DB - and there are cr*p-tonne of those here! Also on an initial quote/visual inspection there is plenty to suggest it's going to be a challenge. I imagine also there is some 'content-value' baked in here - it was after all very entertaining! You also can't just 'fail' the installation and say 'job-done'. As a landlord, I've had an EICR where a supposedly reputed electrician wrote me an 'EICR' on the back of an envelope and said 'I don't bother to write out the full report if stuff needs doing, I'll do it once I've fixed it'. Needless to say he didn't get paid for his day's work but NICEIC wasn't interested - said since he hadn't been paid, nothing to take up. Yet wasted my time, I then needed a new electrician to re-do his mess and lost a month's rent as a result. It's people and trade bodies like that that encourage people like me to do a DIY job and do it properly.
@j22_wys512 жыл бұрын
Fuck. That. 🤣
@matthewlizzio74312 жыл бұрын
What a mess 😅
@raymyhill22 жыл бұрын
Walk away.
@christ94602 жыл бұрын
start over
@bradh20662 жыл бұрын
Rewire
@iansampson24772 жыл бұрын
That can't possibly have been wired by an electrician. If it was he needs to hand his licence back.
@AndrewLumsden2 жыл бұрын
Why bother to differentiate any codes for the EICR just condemn it in its entirety!
@barrypritchard23062 жыл бұрын
If that was I take all of it out and replace the DB box
@zach11062 жыл бұрын
Rip it all out and start again. Ban the diy owner from ever buying a cable tie, junction box, cable… The list could go on. You wouldn’t see someone messing around with there boiler, why do they think it’s appropriate to mess around with electrics.
@inspiringengineer2 жыл бұрын
Encourage the owner to install a new gas supply ;) :D
@e.n.l19762 жыл бұрын
Sadly (as a gas engineer) we do see people messing around with their boilers way more than you would think.
@KizakiAyato5 ай бұрын
Just because you suck at wiring electrics does not mean other people do.
@BarneySaysHi Жыл бұрын
I've never understood countries where the house wiring isn't put in pipes. When I was in school I learned that every circuit needs to go into a pvc pipe (I'm from The Netherlands). The only time you'd see a cable is when it's a 4 or a 5 core VMVK (old type of cable nowadays) is going around a corner. And even that would be put in a pipe when going straight. Seeing the absolute mess on the attic just boggles my mind.
@carlrobson57452 жыл бұрын
Challenge accepted
@bikerchrisukk2 жыл бұрын
I know a lot of it was terrible/dangerous, but man you made me laugh not relating to it 😂 Cheers!
@davidcullen21302 жыл бұрын
Wow that is so shocking that's one of the worst houses that I ever seen so far the customer is so lucky that they didn't even have an electrical fire. It's like spaghetti junction. Unless they are going for a full house rewire I would refuse to put my name on network. The whole thing needs ripping out and starting again
@KizakiAyato5 ай бұрын
Messy wiring does not automatically mean it's going to catch on fire. If everything is sized properly, and crimped properly, it's highly unlikely. At least they didn't have anything piled on top of those wires in the attic. That would have been bad.
@aaronmdjones2 жыл бұрын
This has to be way up there with some of the worst stuff I've ever seen. Jesus.
@timkelliher68552 жыл бұрын
Owner done work himself
@terrystephens11022 жыл бұрын
Unbelievable mess, how there hasn’t been a fire or electrocution is amazing. Pretty much a case of rip it out and start again 🤯🤬
@tobysherring13692 жыл бұрын
A mess yes, but tidy up jumbled cables, new CU, switchfuse and rewire tails, FCU for tumble dryer, and relocation kit to replace loft box and it's sorted. Readings were good - not a full rewire.
@andrewpowell64572 жыл бұрын
I'm no electrician & I was cringing at this
@chriscollins17042 жыл бұрын
Mouse scarer? Some people are insane 😄
@NewAge0fAquarius2 жыл бұрын
im just going to nip to the van
@oninbridders2 жыл бұрын
You keep getting these DIY jobs that then want to get the professionals in. I don't understand, unless it's age, why someone would want to change and apply professionalism to their bird's-nest.