Here's an affiliate link to a NVR I would consider using: gosforthhandyman.com/uk-links/nvr-switch
@slugore5 жыл бұрын
That tape trick!!!!!!!! Life changed.
@StephensCustomModels4 жыл бұрын
The compressor part made me chuckle. Very cool video.
@garrysmythe6 жыл бұрын
Cheers mate, this has to be the best video ANYONE ever watches, I'm 65, and try to keep safe and this kinda helpd me make a better job of keeping my fingers on my hand instead of the floor.big thanks mate //..... from Garry at barnsley
@GosforthHandyman6 жыл бұрын
Cheers Garry! 👍🛠
@eversleyowl6 жыл бұрын
Just found your channel and binge watching. You are right of course, by the end of Easter my router table will get an NVR. Thanks for the timely kick up the behind!
@GosforthHandyman6 жыл бұрын
Cheers and welcome to the channel! 👍
@PhilMakesThings7 жыл бұрын
A good workshop saftey tip, and a very good demonstration of what not to do with your router table. "Takes ages to clean up... he's got no hands" 😂
@GosforthHandyman7 жыл бұрын
By popular request I'll be doing the grand tour of my router table v2.0 very soon! 👍😃
@Tocsin-Bang6 жыл бұрын
Great idea, going to order an NVR switch later for my model making workshop.
@GosforthHandyman6 жыл бұрын
👍🛠
@kerry79323 ай бұрын
Though this video describes using an NVR for safety purposes, I came here looking for a way to protect sensitive and expensive electronics when power is restored after a power outage. This might do the trick. Thanks for the demonstration.
@xbullshet4 жыл бұрын
Thank you. This is definitely very good extra safety option and I just accidentally found this video and i am wondering why l never thought in 40 years about it. This cost nothing to peanuts to implement but gives that peace of mind for once ( well... many) in life coincidence of human error or negligence. Thank you!
@markcort16702 жыл бұрын
Very nice description mate. Thank you very much
@almagill6 жыл бұрын
Doing the specs for a new workshop just now and, having seen this, am adding NVR's to the power strips. Besides the safety aspect it'll look class. Cheers!
@GosforthHandyman6 жыл бұрын
Glad you found it useful! 👍🛠
@caskwith5 жыл бұрын
Great idea. Something else that is very useful is a foot switch. I made an extension cord with a foot switch in it and use it mostly on my drill press. So useful when you need to use 2 hands on the tool.
@tony50064 жыл бұрын
My switch arrived and being a 4 pin type I connected both live wires to one side pair of contacts and the two neutrals to the other side pair. Both earth wires joined on a screw in the bottom of the casing. All works as it should. I made mine as a portable extension so I can take it where ever I need it. Thanks.
@mariojhorge233 жыл бұрын
I'm poor in spark (electricity) - the part in this video that I wanted most to see, u made it fast which is the cables connections, where goes blue, where goes green... But yah, great video. Well done
@skoods13 жыл бұрын
Me too!
@briandavis56312 жыл бұрын
That's what spoiled for me, carried out all the work,and cannot get it to go, due to no information as to the connections
@daveprice6870Ай бұрын
I was going to say the exact same thing I also would have liked to see how the connections were made! But great video and I’m going to make tomorrow morning. After trying to watch a video on the connections.
@XCodeHelpHub2 жыл бұрын
I like this especially for safet in the shop. I will be making one. Very nice!
@NickDV0077 жыл бұрын
Nice job and spot on with the importance of using the NVR switch/button 👍👍👍
@GosforthHandyman7 жыл бұрын
Cheers Nick! 👍🛠
@jessemontgomery5184 жыл бұрын
I like the NVR switch idea. I’m an journeyman electrician in US and found it odd that you put all your electrical connections in a wood box. Is that common in the UK? The reason I bring this up is that the most common place for an electrical system to fail is at the connections. When you have an electrical event you create heat and flame that can set the wood on fire. In the US all electrical connections above 60 VDC and 30 VAC are required to be in a listed junction box. Usually a plastic or metal box designed to handle the heat and flames.
@SteveMonk19562 жыл бұрын
What a great video, picked up some tips and I'll be making one of these very soon. Thank you.
@ColinMill15 жыл бұрын
I know it's not as neat but I use in-line non-latching (active) RCDs. They give you the NVR functionality and the protection against electric shock (I'm old enough to remember the tragic case of Lizzie McMullen).
@couplandsj7 жыл бұрын
Looks a great channel, we need more Brits doing great stuff like you (and Peter Millard who I spotted your comments on).
@GosforthHandyman7 жыл бұрын
Cheers Simon! Yes, us Brits are thin on the ground on KZbin! 😃🛠
@benny51906 жыл бұрын
I added these to the start of my socket loop so I can turn off all socket but to be honest I didnt know they turn off I guess like a trip switch if you lose power great video
@russveinot57547 жыл бұрын
brilliant project, really liked the technique to transfer hole template to the board (using tape), great channel :>)
@GosforthHandyman7 жыл бұрын
Cheers for watching and welcome to the channel! 👍🛠
@HODYODesign7 жыл бұрын
smart, actually!
@JimAckroyd6 жыл бұрын
Great video as usual. NVR's next on the list!
@GosforthHandyman6 жыл бұрын
Cheers Jim! 👍
@BigDan11905 жыл бұрын
Love this idea Andy, attaching a 4 gang to an NVR. Similar applies to going on holiday, don't take 4 adaptors... take 1 adaptor and a 4 gang! I find that those keyhole hooks for 4 gangs can be a bit shit, but one tip i've picked up is to use some of that galvanised banding to strap them down to whatever its being mounted too. Really quick and secure solution. Can even get black plastic coated banding from Amazon if you want it to look nice.
@GosforthHandyman5 жыл бұрын
Yup - I do that too. One adapter and a 4-gang... plus a couple of spare adapters 'cause I'm always para I've brought the wrong ones. 😂
@JuiceBanger15 жыл бұрын
Ffs. Anyone want to buy 3 euro adapters....goin cheap
@BigDan11905 жыл бұрын
@@JuiceBanger1 lmao :D Happy to help!
@johnjude26775 жыл бұрын
Never herd of nvr but now I been giving good advice Thanks
@paultay237 жыл бұрын
"Have some bait".... ha ha, memories of working with a load of North East lads down the pit in Nottinghamshire.. Nice Videos marra Cheers Paul
@GosforthHandyman7 жыл бұрын
Pit in Nottinghamshire? They could literally have brought coals to Newcastle! 😃🛠
@BronkBuilt6 жыл бұрын
Great advice. When I build my workbench I'll be sure to include a NVR.
@TheJunkyardgenius6 жыл бұрын
Great one mate. Defford going to do that in my workshop.
@GosforthHandyman6 жыл бұрын
No worries! 👍
@larndavies69546 жыл бұрын
Good thinking, have power cuts from storms here in Aus regularly, though my router table has an NVR switch built in as well as most of big equipment, I will still add this to where I use power boards because you just never know.
@darrellhale38806 жыл бұрын
Nice mains power control project for both convenience and safety. Maybe I missed it, but at the end only the manual On/Off switching functions were demonstrated. The switch's actual internal NVR feature was never shown to work. With the tool on and running, the orange cord should have been unplugged causing the tool to stop running because of the loss of power into the NVR switch. After the orange cord is plugged back in, the tool should continue to remain off until the NVR "On" button is then pressed again after power is restored. Pressing "On" during the power outage will also not reapply tool power when the main power returns. As a side note, when using friction mounted power strips like that the one you have, I like to add another screw or bumper along the side of the strip that needs to move away from the main (hidden) mounting screws before the strip will come loose. This prevents general vibration or tugs on the cables plugged into the strip from pulling the power strip off the main mounting screws by accident.
@tlangdon126 жыл бұрын
Great video, thanks Andy. If you have any trouble with the 4 gang riding up and off its screws when you pull plugs out, a simple strip screwed across the top would keep it in place. I've even consider butchering Aldi's router table for its NVR switch as they often reduce the table down to £15 when they need the space for the next influx of Workzone kit.
@GosforthHandyman6 жыл бұрын
Good tip! No probs with it coming off so far - might be a later addition. 👍
@Woodwork-Learner5 жыл бұрын
Just reran your very useful video . Love the work thanks.
@learningturningmetal5 жыл бұрын
Perfect - just what I was looking for. My next little project! Cheers Andrew
@nevillewebb28562 жыл бұрын
Thought you might show the wiring diagram or did I miss it? My NVR did not come with any terminal descriptions
@monteglover41336 жыл бұрын
Ditto the tape trick, I had never seen that before. Always unplug equipment or lock out when changing blades or bits! Here in the U.S. they are called magnetic starters, and not required on new shop tools only on large industrial tooling. I do like them and should be required. In the final setup of my shop (2 car garage) is done all of the power tools will be on a single mag starter will E-stops around the shop.
@GosforthHandyman6 жыл бұрын
Great stuff - never heard of magnetic starters too so cheers for the info! 👍
@niwty6 жыл бұрын
A very very good tip Andy and folks please remember, it’s not just your household trips that can remove power to your workshop. I work for an electrical distribution company here in the Midlands (like what used to be Norweb up your way Andy) and power cuts are sadly all too common. When we restore power at the substation or via HV (high voltage) switching we don’t check that everybody has turned their stuff off we just “whack it back on again” so to speak. The time it is off could be in excess of an hour or more so it would be very easy to forget what’s on and what’s not.
@GosforthHandyman6 жыл бұрын
Wise words! 👍
@tony50064 жыл бұрын
Great idea. My table saw and router table have these fitted but I have power strip and some (black) cable (sorry) so I will be making this rig up Thank you. Just have to wait for the switch now.
@RobertKza5 жыл бұрын
Thanks for the video. I hadn't thought of the NVR use for hand power tools, will modify my workshop supply for sure. I have a query. My NVR has 5 terminals, 2 IN, 2 OUT and I understood the 5th is for the supply to the 'latching/NVR' contactor in the switch. Am I mistaken because I didn't see you connect a 5th wire
@slyrmoowen20665 жыл бұрын
Hi Andy. Great video please excuse me for how much of a newbie I am. Love the video but did not understand the wiring at all. I am in Malaysia and we use the exact same wiring as the UK. I have an nvr switch from a dust extractor that did not need an nvr and is on a remote and would like to wire my router setup exactly like you did but I have 4 connections in mi nve: 13/14 and 23/24 and the a 5th I/0. And not sure how to do any of the wiring. Our colors are the same. Is there a way we can chat about it ? Michael O
@backyard.craftsman3 жыл бұрын
Thanks for Very helpful tip
@philippendlebury45183 жыл бұрын
Very useful video - thank you! I'm slinging a 1400 watt router under a table. Would the NVR switch you recommend be sufficient for that? Also I understand that some routers require a device to by-pass the switch otherwise you would have to manually turn the machine switch on and off - an obvious drawback.
@renemedcraft30956 жыл бұрын
Did one like that but put it permanent on my circular saw bench. but the portable one you could put it on the floor to knock off with your foot in an emergency.
@GosforthHandyman6 жыл бұрын
👍😀
@GaryThomsonJoinery7 жыл бұрын
Thanks Andy, workshop joiners aren't by nature the most health and safety minded folk so this is a very good tip. Not sure why you painted inside box, is that the OCD thing you mentioned before 😄 and I hope the router was unplugged before you put your tongue on it!!!!!! I had to look away 😂😂 Thank you for sharing 👍
@GosforthHandyman7 жыл бұрын
Ha ha - painting inside was mostly OCD but I justified it to myself since it makes it easier to see the wires! 😆🛠😃
@jimbarchuk7 жыл бұрын
Nope, sorry, those are very brightly colored wires. It's simply OCD. ;) I'm a safety freak too. The old aphorism that the only real craftsman is missing a few fingertips is complete bullshit. Safety is #1. Safety is all. I do electric model airplanes. The previous generation planes with gas motors were OBVIOUSLY dangerous when they were running, and they couldn't start by accident. The newer electrics are -very- easy to start accidentally. There are a couple of important safety steps to prevent 'unintended startups'. I've witnessed about half a dozen! Fortunately no one hurt by any of those but know of half a dozen more that caused fairly serious human damage. I have personally caused -only- -one- unintended startup, and that scared the furry green shit out of me. Before that I thought I was being safe. After that I got truly militant. And I don't hesitate to call anyone out that I think is being unsafe. Not just for their safety but also for mine and anyone else who happens to be nearby. I like this 'default off --two on switches' concept. It affects me very little but I'll keep it in mind.
@GosforthHandyman7 жыл бұрын
I'm just getting into the planes thing with my son! I was in to r/c in a big way when I was a lad. Great stuff! 👍🛠
@andyburns6 жыл бұрын
You appear to use a blue crimp connector on neutral and a red one on live, as though the crimp colours are for that purpose, but the crimp colours are for different cable sizes ...
@tony50064 жыл бұрын
How is the switch wired, you were not clear when making the video. Thank you.
@watchthisspace6882 жыл бұрын
Hi, confused how the four gang works in this application, surely if you have 4 tools plugged in they will all come on with the nvr switch, so my bench mounted router will start up unless I've unplugged it, might as well just have one socket. Please let me know if I've misunderstood.
@felixreali71013 жыл бұрын
Hi Andy, long time fan. I've watched this vid about10 times now and love it. qq though (and anyone can answer :-) ): at the end of the video, where you test it, isn't the tool supposed to stay "off" when you press the green button on the NVR? I thought that was the whole point of this: for the tool not come back on when you press the green button again? I must be missing something here 🤔 lol
@SquareRootOfMinus1 Жыл бұрын
Yes … bump this thread up. I am confused also. I thought the power would remain OFF once the NVR switch was used… Until the user positively reconnects using the green ON switch. Did I miss something ?
@MrEd-fu3dq6 жыл бұрын
Very nice! I never used an NVR switch, but over the years I made a few similar outlet strips that used a toggle switch as the master on/off strip between a pair of retail power strips so I could turn off all power to the workbench where those power strips were mounted. That was years ago, long before the "safety nazi's" stuck their heads into the scene. I also made one that used commercial WireMold surface mounted wiring races (1/2" / 12.5mm thick x 1" / 25mm high and pretty pricey, but limited space offset cost) which had an A-C outlet every 6 inches; mount the back plate to whatever (wall of bench) and snap the front part with the wiring and outlets onto the back plate and connect the power source. I mounted toggle switch box (aluminum hobby box) at one end, which I made for an electronics workbench for the attached shelf 18" above the bench top using 90 degree angle brackets and the bottom of the shelf a few inches from the back of the bench facing the front. Easy access to plug-in soldering irons and other, along with the shop sound system; one switch and everything got turned off at once when I was done for the night. Suggestion: Your switch box sticks out too far from the workbench top. I realize that the NVR switch needed room for the wiring, but I would have routed out a recess in the mounting board for the wires so that the wiring went into the mounting board to use that ~ 25mm and the switch would have been almost flush with bench top with it recessed into the mounting board. The 3-wire cables could go out the side of the "box" & mounting board into grooves cut with a router.
@GosforthHandyman6 жыл бұрын
Great stuff! Wanted it to be as easy to 'hit' as possible when the router table is set-up. The downside is that when it's not set-up it's still just as easy to hit. 😂👍
@richardgregory46405 жыл бұрын
Doesn't having a 4 gang outlet negate the whole benefit of the NVR? I mean, if you have more than one piece of equipment plugged in then you could still have an unexpected 'live' tool.
@brianmogle11215 жыл бұрын
Thats why when changing any blade or bit on any power tool, the cord should be removed from the outlet. Unplug the tool from the power so you don't have that issue. I do like the added safety of these switches though.
@Ournewlife5903 жыл бұрын
Great video could I wire one of these into my router cable if I’m only using the button for that one bench
@londonmaker53476 жыл бұрын
That's hilarious. I was thinking that the orange cable is cool and I'd like to get some of that. Each to is own lol
@GosforthHandyman6 жыл бұрын
Ha - the colour is great but it's just horrible to work with. 👍
@elvisoshaughnessy12555 жыл бұрын
Hello andy, I am a Handyman in my home boundaries area. I have a dewalt DW745 table saw.but some reason I don't get correction measurement after making a cut, now please make a video on dewalt DW 745 Measuring Label or how to get correct measurement. What is the white coulume of measurement represent and what is the yellow measurement represent presented on dewalt DW 745 table saw
@Ravi-or6xc7 жыл бұрын
Great video Andy and I totally agree with you that an NVR is needed. I am contempalting on putting one on my Dewalt DW745 table saw as I think that its dangerous to use it without a descent one, the manufacturers one is PANTS, LoL PS, where did you source it from, do you have a link please?
@GosforthHandyman7 жыл бұрын
I just got the Kedu one off Amazon (just search for NVR switch) - kind of mid price. Didn't want to go for the cheapest lol. I find the switch on my DW745 is in a terrible location - I always have to 'hunt' for it! 👍
@ronh93845 жыл бұрын
Is the NVR you used here a magnetic switch or a relay style switch. A couple of my tools have a magnetic switch on them and the removable on button has a magnet on it and if you pull that on button off no one can start the tool. The magnetic on button acts as a key. If the on button is in your pocket or put on the side of the tool no one can start the tool. And it also shuts the power off and will not start back up if the power is interrupted. You have to hit the on button again. Ron
@allthegearuk4 жыл бұрын
I know you're not an electrician so I will research else where too. But is there any reason you know why I couldn't wire one of these into the ring main for my workshop so all the sockets are connected to it?
@Bear5026 жыл бұрын
Nice except for four gang which causes a hazard. Best practise to have separate NVR for each tool.
@GosforthHandyman6 жыл бұрын
How does it cause a hazard?
@Bear5026 жыл бұрын
You can have multiple tools connected so that you can switch on for one and another will start. Small risk for you as you usually work alone but I have seen it happen
@gmorris89505 жыл бұрын
Can you tell me which terminals in this NVR connect to router and which terminals connect to supply power please
@choiceblade5 жыл бұрын
LMFAO!!! Got my sub when you demonstrate adjusting the router bit with you tongue!! I'm in, dude. Freakin' hilarious. PLUS, good explanation. Lot's of legit injuries in shops that way, eh?
@yousefalhendi26384 жыл бұрын
Thank you , it is perfect
@benjamindebellis66646 жыл бұрын
I have possible a stupid question. I added a magnetic paddle type switch to my table saw. Is a magnetic switch a type of a no volt release switch?
@michaelord80842 жыл бұрын
Groove Armada 👌
@davidurwin44993 жыл бұрын
Hello friend. Do you know of such a fault with this type of switch my switch is the DKLD DZ-6-4 15A 250V . Sounds like the off button when switching the machine off, has a vibration in the switch, like some thing is pushing from the other side. Can you please tell me if this is normal.
@robt21513 жыл бұрын
Bit late now but if you put the nvr right against the other end of the 4gang then you wouldn't need the cable running behind your mounting board
@AndrewMcQuillen6 жыл бұрын
Ok really dumb question but can I have the NVR switching on the whole of my workshop and run tools with a NVR from those. I'm mainly thinking of having an NVR for my Dewalt DW745 table saw where the off switch is really hard to find when switching it off. But with the inline NVR to one side I could find that a lot easier.
@GosforthHandyman6 жыл бұрын
I don't see any reason why not if they're rated appropriately - obviously you'd end up having to switch the first one 'on' first... then the second one, which might be a pain. 👍
@AndrewMcQuillen6 жыл бұрын
I did think about that it's just the switch is hard to find but I'll probably get used to it. Thanks any way. I'm really enjoying your Chanel every time I watch a video I learn something new😀
@jimbo26296 жыл бұрын
I have just subscribed. I chuckled at one stage. Get yourself a sander cleaning stick for that disc sander . Axminster sell them. Also on eBay.
@GosforthHandyman6 жыл бұрын
Welcome to the channel Jim! 👍🛠
@martinmackett27585 жыл бұрын
I just use a screwed up plastic bag to clean up my sanders, since there seems to be no end of waste plastic about!!
@gman76922 жыл бұрын
Good work. However, the plug should have been fitted to the orange flex as the very last task. That way, you avoid any mishaps with your mate coming into the workshop after your phone rings & you've gone to the pub half way through the build.
@Sphyderman6 жыл бұрын
Good vid, just what I was looking for. Could have used a little more info on the actual button wire up though.
@GosforthHandyman6 жыл бұрын
Cheers! Wiring deliberately not shown as specific to switch and not to be touched if folk aren't competent with electrics. 👍
@homewurks13 жыл бұрын
@@GosforthHandyman I have a KJD12 which I believe is the same as the one in this video. Any chance of seeing the wiring diagram?
@haleccles19716 жыл бұрын
Brilliant!
@GosforthHandyman6 жыл бұрын
Cheers! 👍
@jimblack23316 жыл бұрын
Great idea!!!
@GosforthHandyman6 жыл бұрын
Cheers Jim! 👍🛠
@SamValiant5 жыл бұрын
Most of these switches seem to forego the earth contact. Isn't that a bad idea? Or are you meant to wire that directly and bypass the switch?
@GosforthHandyman5 жыл бұрын
Earth isn't switched - you wire directly to ensure continuity of earth. 👍
@SirBenJamin_7 жыл бұрын
Someone clearly didn't read their router manual .....Page 967 - it clearly states NOT to lick your router bits!!!. And just in case, here are some of the other things you shouldn't do. ..... Don't stick them up your nose ....Don't swallow them ... Don't drop them into your bacon sandwich ... Don't rub your willy on them ....
@GosforthHandyman7 жыл бұрын
Lol, yes... I guess they deserved it. 😆👍
@niwty6 жыл бұрын
wforl That willy one is that true? I thought that was just a phallusy! 😉
@barryroberts64707 жыл бұрын
Nice little wire up job and set up there, there's nowt wrong with orange cable, at least you can see it clearly in your workshop. Keep up the good work. Barry (West Kirby, Wirral)
@GosforthHandyman7 жыл бұрын
Cheers buddy! It's just really plastic-y - I want to get some of the rubber sort of stuff you get on Festool tools etc... can't remember what it's called. Costs a fortune though. 👍😆
@tonyprice75444 жыл бұрын
Does the R.A.F square bashing camp still operate in w/k I was there in 1948 . ?Just going down memory lane
@JasonShowell6 жыл бұрын
I wired the entire workshop to an NVR and an emergency stop button. Power goes off with the lights and won't come back on until someone turns it back on.
@GosforthHandyman6 жыл бұрын
Clever! 👍🛠
@mungrus2 жыл бұрын
Would an rcd plug work in place
@taniafrankle74124 жыл бұрын
How do you integrate NVR with an automated vacuum switch?
@frrapp23664 жыл бұрын
i noticed that the plug you put on the cord was fused are all plugs in uk fused like that im from oklahoma usa i have never seen a replacement plug with a fuse in it!!!?? nice vid
@GosforthHandyman4 жыл бұрын
Yeah, all UK plugs are fused. 👍
@frrapp23664 жыл бұрын
@@GosforthHandyman not in US course most are only 120 v but think would be handy sometimes thanks for the info (rod for Wakita OK)
@peckelhaze69345 жыл бұрын
Trying to use a foot pedal with an NVR is a bit of a nuisance. Had to bypass mine on a scroll saw as I wanted a foot pedal to make intricate cuts and keep pressing the on switch was very inconvenient. This will not suit everyone and will probably be frowned upon but since I am the only person here and it has earth leakage protection in works for me. I have NVR's on all of my other power tools, saws, routers etc..
@johnhunter98773 жыл бұрын
Really liked the video, thanks for making this, but I could not get my head around the fact you wired the plug first after your safety comments. What if your phone had rung and your mate plugged it in thinning it was the plug for a tool he was going to use, then realised he had plugged the wrong one in and it didn't start the tool so finds the one he was looking for and plugs that in too, but didn't remove the one you had just wired. You come back from your phone call/lunch what ever and carry on with the swith end, you are now holding a live wire. Sorry 😞 just thought I would point that out, do the plug last, for safety's sake, work safely guys.
@loktom40686 жыл бұрын
I use a portable power bar to plug in all my power tools.
@sparkfishes3 жыл бұрын
But you did not show which wire went where !
@geoffreymaddison64345 жыл бұрын
I'm a bit predantic when it comes to electric, I always solder the wires before fitting to the plugs
@mistermartin825 жыл бұрын
Solder isn't a good idea, as it leads to loose connections, solder is quite soft and it will creep over time causing the connection to be less tight, this won't happen with the bare copper
@geoffreymaddison64345 жыл бұрын
Thanks for this, will keep your advice in mind, appreciate it. Best regards Geoff Maddison
@geoffreymaddison64345 жыл бұрын
Thanks for the tip, I have 4gangs every where.
@bikewreck856 жыл бұрын
which way do the wires go on the switch?
@GosforthHandyman6 жыл бұрын
The switch should come with instructions showing where to connect the wires up. 👍
@bikewreck856 жыл бұрын
They didn't :(
@bikewreck856 жыл бұрын
How do you wire a switch up with no instructions.
@GosforthHandyman6 жыл бұрын
It's normally just L & N IN and L & N OUT (+ earth obviously) - but you need to know which terminal is which.
@markhollingsworth30975 жыл бұрын
If Safety is the name of the game for this video then the last thing you did should've been the wiring to the 13amp plug.... Never put a plug on a length of flex with a bare end 😉
@aleksamaker81187 жыл бұрын
Are you from UK or Australia
@GosforthHandyman7 жыл бұрын
Newcastle, UK! 👍
@willford84756 жыл бұрын
"ASAGEORDIEYAFUKNMONGWHEYAYE"
@Sphyderman6 жыл бұрын
That's a UK accent, and UK plugs...
@Sphyderman6 жыл бұрын
And yes, there is a Newcastle in Australia
@dashaB-sl4pu3 жыл бұрын
By my understanding an NVR is a No Voltage Relay, not release
@sammetcalfe14 жыл бұрын
"and he's got no hands" :D
@gbwildlifeuk82694 жыл бұрын
Your example of the person trapping his fingers in the router, not realising the power is still fed, is why in industry they lock off and tag. For domestic despite the NVR, before changing bits, blades etc, TAKE THE PLUG OUT!
@ben_the_cat_guy6 жыл бұрын
Who cares about the friend that got mangled the blood might of damaged the router
@GosforthHandyman6 жыл бұрын
Exactly! 😂
@MD0MDI6 жыл бұрын
Wow, another person that French kisses his router bits!
@GosforthHandyman6 жыл бұрын
Of course! 😂👍
@fiveeightdrumstudio34993 жыл бұрын
I cringed so hard with that story, your mate kissing the router bit gets his face ripped off.
@WPGinfo4 жыл бұрын
Interesting topic, but wwaaayyy too long introduction....
@KW-ei3pi2 жыл бұрын
Great idea. WAY too much talking. 4-5 sentences would probably have been sufficient.
@rorygray29755 жыл бұрын
Really wanted to see how to wire the nvr switch....sorry but wasted my time.
@GosforthHandyman5 жыл бұрын
You need to check the instructions for your NVR.
@superiorbeing954 жыл бұрын
I'd have though if you can't figure that out yourself you shouldn't be tinkering with this anyway.