Installing a 18th Edition RCBO/SPD Consumer unit | Walk through Video

  Рет қаралды 13,499

LET Electrical & Renewables

LET Electrical & Renewables

Күн бұрын

Пікірлер: 31
@LawrenceTimme
@LawrenceTimme 23 күн бұрын
Finally a video where someone has a board as old as mine! Most of my house is on only of these old fuse boards with no rcd 😂😂
@Chris-hy6jy
@Chris-hy6jy Жыл бұрын
Personally I'd have routed the tails into the bottom right of the board to keep them clear of the circuit wiring, but good job all the same!
@basimmaan4549
@basimmaan4549 2 жыл бұрын
Hi csn you confirm me how much it cost to change the old cunsomer unit very basic one with there or four like one you filmed in lndond eara thanks
@tonyleo7529
@tonyleo7529 2 жыл бұрын
Does the equipotential bonding on the gas have to be before the tee on the gas outlet pipe? I know nothing about electrical requirements. Not sure how much of a difference it would make on this installation? As a gas engineer, just wondering how much of a difference it would make here? Nice tidy work on the consumer unit.
@letelectricalservices5143
@letelectricalservices5143 2 жыл бұрын
Morning, The regulation like the gas bonding to be installed within 600mm from memory as stated here "The main equipotential bonding conductor connection to any gas or other service should be made as near as practicable (preferably within 600mm) to the point of entry to the premises." Hope this helps
@12000gp
@12000gp 2 жыл бұрын
Who pulled that main fuse out?
@JohnDundee-el2ro
@JohnDundee-el2ro 19 күн бұрын
Could the water bonding earth wire not be run in the house theres always a way it's a serious mess how it's done clipped surface round the house don't know how the house owner allowed that also the T&E cables clipped surface in the garage for the switches and sockets should be in plastic trunking or conduit drops into pvc knock out boxes
@keithjackett9895
@keithjackett9895 2 жыл бұрын
Can you explain to me why there are 3 red 2.5 wires in 2 of the 32 Amp Rings? Are 2 of them for a Ring and the 3rd a fused spur maybe??? Answers Below Please .
@letelectricalservices5143
@letelectricalservices5143 2 жыл бұрын
Correct, 3rd is a spur
@Baggiolyful
@Baggiolyful Жыл бұрын
When I did my 18th edition refresher course my teacher pointed out that you are allowed to spur off a ring Mcb with one double socket and there it was in the regs book I didn’t know. This was useful recently when I needed a double socket in a cupboard for a cctv rack but the board was full.
@keithjackett9895
@keithjackett9895 Жыл бұрын
Yes you are correct, i was thinking of an optimal design where one wouldn't require an add-on spur. thankyou for your responce Sir.@@Baggiolyful
@kennyla4060
@kennyla4060 11 ай бұрын
Your aloud to fuse spur directly from the mcb
@keithjackett9895
@keithjackett9895 11 ай бұрын
What about bridging a RCBO cos you can only get 2 x 2.5mm cable in each Live & Neutral terminals? Are Wago blocks aloud??
@dryflyman7121
@dryflyman7121 2 жыл бұрын
Not advisable to have fridge/freezers in garages. In winter when temperature drops, many stop working as designed to work indoors only. I think there are only one or two makes that will work in garages.
@Splitscreen83
@Splitscreen83 5 күн бұрын
Gas bond needs to be before the first junction.
@ianmiller3182
@ianmiller3182 2 жыл бұрын
Nice run through. Was the water supply a metal service ? The gas bond probably should have been before any branches.
@electricalsolutionse4ltd700
@electricalsolutionse4ltd700 2 жыл бұрын
Good job brother, love those lewden boards.👍👍👍👍👍👍👍
@Dontmindme__
@Dontmindme__ 2 жыл бұрын
Is that bonding cable protected against UV?
@letelectricalservices5143
@letelectricalservices5143 2 жыл бұрын
It's not the best solution but only solution we had due to tile flooring and bathroom above the kitchen. Alot of Bonding cables are run externally and gas meter are normally situated outside in local area with no near entry.
@Dontmindme__
@Dontmindme__ 2 жыл бұрын
Think you’re missing the point, should be in conduit or otherwise protected against UV
@AGRElectrics
@AGRElectrics 2 жыл бұрын
@@Dontmindme__ give me a reg number that states this? Granted best practice but I can't think of any that would support it 🤔
@James_scott86
@James_scott86 2 жыл бұрын
You think UV is going to degrade a thick insulation and a 10mm copper? Been in the industry 20 years and have never heard that.
@simonmartin3433
@simonmartin3433 2 жыл бұрын
@@smudge0161 What's earth bonding?
@electricalservicesmaroc
@electricalservicesmaroc 2 жыл бұрын
Ok chef
18th edition Fuse board/ consumer unit change walk through, Electrician
18:41
Surge Protection Devices - Part 1
24:01
John Ward (jwflame)
Рет қаралды 220 М.
How Strong Is Tape?
00:24
Stokes Twins
Рет қаралды 96 МЛН
It works #beatbox #tiktok
00:34
BeatboxJCOP
Рет қаралды 41 МЛН
My scorpion was taken away from me 😢
00:55
TyphoonFast 5
Рет қаралды 2,7 МЛН
LEWDEN CONSUMER UNIT with DOUBLE POLE RCBOs
13:42
eFIXX
Рет қаралды 42 М.
The single mod SPD they didn’t tell us about!!!
12:10
CJR ELECTRICAL
Рет қаралды 66 М.
Fitting an RCBO in a Consumer Unit
12:33
John Ward (jwflame)
Рет қаралды 610 М.
HOW I INSTALL A CONSUMER UNIT NEATLY!! (BONUS Q&A)
29:38
Jimbo The Electrician
Рет қаралды 46 М.
18th Edition Consumer Unit Upgrade Glamorous Life Of An Electrician
20:13
Installing a new Fusebox F2010MX consumer unit!
8:27
The Cable Guy
Рет қаралды 23 М.
10 Mistakes EVERYONE Makes When Doing DIY Electrics!💥
11:56
Artisan Electrics
Рет қаралды 254 М.
SPD INSTALLATION IN A CONSUMER UNIT - HOW TO and THE BASICS
11:46
LEARN ELECTRICS
Рет қаралды 103 М.
The BG Consumer Unit Update: What's Changed?
9:51
eFIXX
Рет қаралды 28 М.
How Strong Is Tape?
00:24
Stokes Twins
Рет қаралды 96 МЛН