Finally a video where someone has a board as old as mine! Most of my house is on only of these old fuse boards with no rcd 😂😂
@Chris-hy6jy Жыл бұрын
Personally I'd have routed the tails into the bottom right of the board to keep them clear of the circuit wiring, but good job all the same!
@basimmaan45492 жыл бұрын
Hi csn you confirm me how much it cost to change the old cunsomer unit very basic one with there or four like one you filmed in lndond eara thanks
@tonyleo75292 жыл бұрын
Does the equipotential bonding on the gas have to be before the tee on the gas outlet pipe? I know nothing about electrical requirements. Not sure how much of a difference it would make on this installation? As a gas engineer, just wondering how much of a difference it would make here? Nice tidy work on the consumer unit.
@letelectricalservices51432 жыл бұрын
Morning, The regulation like the gas bonding to be installed within 600mm from memory as stated here "The main equipotential bonding conductor connection to any gas or other service should be made as near as practicable (preferably within 600mm) to the point of entry to the premises." Hope this helps
@12000gp2 жыл бұрын
Who pulled that main fuse out?
@JohnDundee-el2ro19 күн бұрын
Could the water bonding earth wire not be run in the house theres always a way it's a serious mess how it's done clipped surface round the house don't know how the house owner allowed that also the T&E cables clipped surface in the garage for the switches and sockets should be in plastic trunking or conduit drops into pvc knock out boxes
@keithjackett98952 жыл бұрын
Can you explain to me why there are 3 red 2.5 wires in 2 of the 32 Amp Rings? Are 2 of them for a Ring and the 3rd a fused spur maybe??? Answers Below Please .
@letelectricalservices51432 жыл бұрын
Correct, 3rd is a spur
@Baggiolyful Жыл бұрын
When I did my 18th edition refresher course my teacher pointed out that you are allowed to spur off a ring Mcb with one double socket and there it was in the regs book I didn’t know. This was useful recently when I needed a double socket in a cupboard for a cctv rack but the board was full.
@keithjackett9895 Жыл бұрын
Yes you are correct, i was thinking of an optimal design where one wouldn't require an add-on spur. thankyou for your responce Sir.@@Baggiolyful
@kennyla406011 ай бұрын
Your aloud to fuse spur directly from the mcb
@keithjackett989511 ай бұрын
What about bridging a RCBO cos you can only get 2 x 2.5mm cable in each Live & Neutral terminals? Are Wago blocks aloud??
@dryflyman71212 жыл бұрын
Not advisable to have fridge/freezers in garages. In winter when temperature drops, many stop working as designed to work indoors only. I think there are only one or two makes that will work in garages.
@Splitscreen835 күн бұрын
Gas bond needs to be before the first junction.
@ianmiller31822 жыл бұрын
Nice run through. Was the water supply a metal service ? The gas bond probably should have been before any branches.
@electricalsolutionse4ltd7002 жыл бұрын
Good job brother, love those lewden boards.👍👍👍👍👍👍👍
@Dontmindme__2 жыл бұрын
Is that bonding cable protected against UV?
@letelectricalservices51432 жыл бұрын
It's not the best solution but only solution we had due to tile flooring and bathroom above the kitchen. Alot of Bonding cables are run externally and gas meter are normally situated outside in local area with no near entry.
@Dontmindme__2 жыл бұрын
Think you’re missing the point, should be in conduit or otherwise protected against UV
@AGRElectrics2 жыл бұрын
@@Dontmindme__ give me a reg number that states this? Granted best practice but I can't think of any that would support it 🤔
@James_scott862 жыл бұрын
You think UV is going to degrade a thick insulation and a 10mm copper? Been in the industry 20 years and have never heard that.