My father installed 4 rods himself right on top of the house, cable is through exterior too and grounded several feet below. We get a lot of lighting & T-Storms during summer. So, we're blessed, there has never been any issues.
@JP-rf7px3 жыл бұрын
Speaking as a retired electrical engineer; When a lightning strike occurs, the bolt creates a path of ionized air from cloud to ground. That's why you see the flash. That path conducts really well. The idea is two fold. The rods on the roof will leak off charge from the air over the house so it doesn't build up there as much. That's why more than one rod on the roof. Hopefully it will hit your neighbors house or the tall tree nearby, or the utility pole on the street that is taller and has a grounded conductor. Then if it does build up too much or too quickly and hits your house,, the ground wire will "guide" the ionized path to follow it to ground as it is the lowest resistance path. But that ionized air is several thousand degrees hot! Conductor in attic is a very bad idea, should be on exterior. Sorry about that "wife acceptance factor". I would drive the ground rod several feet from the house, not next to it. Several on 6ft centers would be even better. And I wouldn't tie it to the electrical service ground as that can be a path for the surge right back into your house wiring. And the lightning ground system should be better than your service panel ground anyway as it needs to handle thousands of volts, not just 120 or240 volt faults.
@networkingdude2 жыл бұрын
All ground rods must be bonded together to meet code. Also the energy will not make it back into the house as the ground is a conductor, not your electrical panel.
@JP-rf7px2 жыл бұрын
@@networkingdude The ground bar in your electrical panel is connected to the rod outside. Sometimes this goes thru the electrical meter socket. However, code also requires that at the main panel, the NEUTRAL bar is "bonded" (by a screw) to the ground bar. This means the Neutral on everything in your house (one side of each receptacle) is also effectively connected to ground and the house ground rod. At a lightning strike the main part of the strike hopefully goes to ground via the lightning rod ground if the connection is low enough resistance. But the ground can only absorb so much current at a time and for a fraction of a second the area around the rod for several feet will be charged with thousands of volts. This why it's best for the lightning system to be away from the building with several rods spaced several feet apart to spread out the charge. Also lightning is NOT direct current. Once the strike begins it oscillates at a high frequency, which is why you hear it on radios, particularly AM. Any sharp bend in the grounding system wires forms an inductor which is like resistance at high frequencies and reduces the ability of the ground system to take the charge to ground. So all bends should be gradual, maybe 6 inch radius minimum.
@abrandpluckedoutofthefire80432 жыл бұрын
@JP Hello. May I ask under what circumstances should lightning protection be installed at a normal house ? I have a three-story house with an attic , no basement, and there is a house of the same height next to it. It often rains where the house is located
@JP-rf7px2 жыл бұрын
@@abrandpluckedoutofthefire8043 If your area has a high incidence of lightning storms, or if you are on a high piece of ground without taller things around you makes you especially vulnerable. But it can hit most anywhere. If you have metal on your roof, like a chimney cap or antenna, it should be grounded at minimum.
@abrandpluckedoutofthefire80432 жыл бұрын
@JP Thank you for reply
@nonyadamnbusiness9887 Жыл бұрын
Sometimes I think "This Old House" should be called something like "Numbskull Renovations". As if running a lightning rod ground cable through the attic wasn't bad enough, they screw it down to the pine framing with copper tabs. Then they don't mention the necessity of bonding the lightning rod ground to the electrical system ground. They've built a system to transfer lightning from outside to inside the house.
@josephmauldin36 жыл бұрын
That is a great setup! I never thought about protecting my home like that. I have had lightening hit just a few feet away from the house a couple of times and it has really done some damage to everything inside.
@dennismcandless32762 жыл бұрын
But the cable inside the attic attached to bare framing. Wouldn't that cause a fire if you had a lightning strike.
@NSMike876 жыл бұрын
While lightning rods CAN ground a lightning strike, that's not the goal. Lightning rods ground the charge buildup that causes lightning strikes to happen in the first place.
@tonythetiger98396 жыл бұрын
I'm glad someone already said this... 95% of commenters don't realize it's for leaching charge from the local atmosphere...
@bum-edwhu664 жыл бұрын
some of the time, not all the time
@bum-edwhu664 жыл бұрын
@Fact Checker total and utter rubish
@scotts61512 жыл бұрын
"some of the time, not all of the time". what are you talking about? You think there is lightning occuring without electricity? Your comment makes no sense. When a cloud builds up a charge strong enough for it to discharge to the earth, the electrical field from that cloud extends well down below the surface of the earth. It has to, by definition. Else how else do you think the lightning bolt knows where the closest conductor is? Electricity doesnt peek out from the cloud and look for the tallest tree, it doesnt have eyes or yardsticks or testing equipment to find the best way to go. It knows that from the electrical field it generates. The huge number of electrons on the bottom of the cloud push down on the electrons on everything below it, which push back just as strong if they are in nonconductors like a fiberglass pole, but in the case of a conductor, like a wet tree or a lightning rod, the electric field slides through the conductor, and lets the charge bleed off. Now a metal rod conducts better than a tree, so more charge is allowed to bleed off and hopefully the total charge in the cloud isnt allowed to build up enough to cause a lightning bolt. A tall wet tree isnt as good at conducting, so more often enough charge builds up to cause a lightning bolt when then shoots down the same path to ground, i e., through the tree. Lightning rods dont sometimes conduct electrical charges and sometimes not. This happens everytime, not just "some of the time, not all of the time.". why would you even think that?!!
@SYLperc2 жыл бұрын
there's a reason capacitors are flat. pokey things leech voltage way easier, which lowers the capacitance to the ground helping the lightning choose somewhere else to go.
@coleve85966 жыл бұрын
What stops the threaded bolt on the roof from rusting out. Why is the through the roof bolt not copper or brass. Why change to steel when it does not have the same conductivity as brass or copper, I would have thought dissimilar metals so far apart on the noble scale would encourage electrolysis in damp conditions.
@chandler19685 жыл бұрын
Stainless which is compatible with copper or brass.
@Efferheim3 жыл бұрын
Why yes, the galvanic corrosion is a concern, especially on the copper parts; but why would you put the least conductive part of the entire system intentionally being surrounded by the flammable wood and asphalt of the roof when you are attempting to shunt huge amounts of electricity to ground.
@villayatMuhammad4 ай бұрын
Can I run the lightning protection naked copper wire through the attic and through the wall and cover it with the foam insulation. I read the 780 SPEC and according to it I can.. could you please verify my understanding as someone told me that, the heavy current when run trghough the conductor, may burn the trusses or foam insulation. My understanding is, teh copper wire will not get that hot when lightning current passes through in case of lightning strike. Appreciate your help and support. Thanks Villayat
@PlayRightParent2 жыл бұрын
When you put the rod into the ground, how do you know your not going to hit any utilities?
@coleve85966 жыл бұрын
Notice no topography mentioned before hammering ground bar into ground. Ie checking for other utilities that may be buried
@rawmilkmike5 ай бұрын
This used to happen to me when I changed the streetlight bulbs under transmission line. It's capacitive reactance.
@LVang1526 жыл бұрын
Will the copper burn the wood?
@SkillT3K3 жыл бұрын
the video is interesting and informative , I've been installing lightning arrester across saudi arabia, the video didn't show how you connected the surge device in relation with the grounding and lightning aerial.
@gregbernard4466 Жыл бұрын
The surge device goes to a 2 pole breaker in the electrical breaker box. In Residential dwellings in the USA we have two hots of 120v so a double pole breaker goes to those two hot legs in the breaker panel. There are neutral and ground wires on the surge device and they are connected in the panel as well. Usually the electrician tries to place the double pole breaker for the surge protector close to the main breaker (usually at the top of the circuit panel). That may involve relocating another breaker to another spot in the panel. So the surge device is just connected to a two pole breaker in the electrical panel.
@jcusak6 жыл бұрын
Copper and brass is used for the whole install, then the main rod on the roof is connected with a piece of steel all thread. Doesn't seem to make sense, or am I wrong? @ 1:10
@maxchartier6 жыл бұрын
i didnt understand that either. they also didnt use any corrosion inhibiting compounds in between the dissimilar metals. i do not think this will work long term because of that steel all-thread..
@bum-edwhu664 жыл бұрын
@@maxchartier there WILL be some bi-metallic reaction there for sure
@Efferheim3 жыл бұрын
Also, huge amounts of power are going through it, which is why you want to use copper. But hey, let’s put steel through the part that is going THROUGH the wood of the roof. Steel, the metal known for conducting electricity better than copper. Also for cooling back down after being heated up faster than copper... oh wait, no; it stays hotter and conducts worse.
@robertotrinanes17446 ай бұрын
you should test the thermal resistivity of the grounding rod.
@WrenchAddiction6 жыл бұрын
Man that’s a lot of copper 😲
@TOPmusicman86 жыл бұрын
"coppah"
@WrenchAddiction6 жыл бұрын
TOPmusicman8 😂
@Bank2BankBassfishing6 жыл бұрын
You getting ideas? Metal prices are kinda low right now lmao
@LIGamingTV6 жыл бұрын
copper aint worth shit tho
@afh76896 жыл бұрын
Maybe that's the real reason they ran the copper through the attic and enclosed it in a pipe on side of house.
@BonnieKay13Ай бұрын
I'm an engineer also, do NOT have cable in attic, this needs to lay on the roof near the peak, taller those rods are the better, do not need to be copper,, even re-rod will work, sharpen to a point, I have rods 3 ft. tall, ten feet apart. This drains off the buildup above in a storm, the idea is to not get hit by a strike, prevention is the keyword. JP is correct, don't ground phone or electric to your lightning setup. My rods are from 1914, the real thing, our house is from 1899 and still here, that says it all. I've also installed a metal roof, that's grounded as well. Get rid of those asphalt shingles, metal means fire and lightning protection, also means you will never have to re-roof the house again. Also, do not put your down cables thru' the roof, they need to go around the roof edge in the open. Do NOT depend on taller things around to protect your home, lightning can strike anything it cares to hit. Up-strikes tend to be cold lightning, down's tend to be the hot ones but don'''t depend on that either. Rods will protect outward also, but do not walk around your house in a storm to test this, rubber shoes do not help, little does.
@jimh4167 Жыл бұрын
What size was the grounding conductor. (Cable)
@frequencywatchers Жыл бұрын
1:24 He Did Secured The Cable Wrong, It Shopuld Loop Around And He Should Secure It With Equal Pressure To The Plate, Now Its Not Like That !
@Cityboy412952 жыл бұрын
Does the lightning rod also pull electrons from the air aswell???
@iowaunemployment2 жыл бұрын
Do you bury the top of the ground rod or leave it uncovered?
@bagofchicken2 жыл бұрын
You sink the rod below ground level so no one trips on it or hits it with the mower. But If you're area requires inspection then you leave the connection exposed until it's checked. Then you can cover it.
@DylanBegazo5 жыл бұрын
By 0:20 you already know it won’t protect you from lightening surges that come through telephone poles or power lines cause those rods only provide a path for the lightening from the sky via the rods. Not via power lines or cables like telephone cables for example. Hence this video’s Flag ship device is only one part of total house protection
@craigstephens88454 жыл бұрын
Wrong..
@TaylorHockeyVideo4 жыл бұрын
At about 3:20 they install a breaker box surge protector. The principle on this is that any surge that comes in on the main line or any other circuit due to an indirect strike, will cause the protection device to route to ground and blow a dual 50 amp breaker. The 50 amp breaker is actually protecting the protection device from taking a sustained flow. The device has to be as close to the incoming AC lines as possible so that it forms the shortest possible path for the surge. Shorter than any other circuit in the house. There are a number of more thorough videos about these devices, their function and installation.
@guywebster80186 ай бұрын
I had lightning strike the roof of my home. Fried thousands of dollars in equipment. Just set up a smart home system and I'm always paranoid about it. Matter of fact aside from surge protection I flat out unplug everything. 😂😂😂
@dumpsterjason6 жыл бұрын
Came here after the livestream. Great job!
@TedSchoenling9 ай бұрын
So how the rods actually work is they bleed off charge slowly in order to actually prevent lightning.. but in the event of a strike yes it does disperse the hit.. but the idea is that it bleeds off the charge so there is no lightening to your house
@marriagepartnersministry5942 Жыл бұрын
Wouldnt it be better to run a thick copper wire up a tall tree right next to the home and ground that wire? It would be taller and would keep burning away from the home. If there isnt a tall tree close to the home then maybe a metal tower for a wind turbine or ham radio tower would be a good location for a lightning rod?
@ericr2zz6 жыл бұрын
The copper cable connected to the ground rod will eventually oxidize and turn green. This most likely will cause the "wire to rod" connection to fail. This connection should have been protected from moisture and the elements. With the connection buried underground, one will never notice the oxidation.
@sinista65366 жыл бұрын
Eric R Dont talk rubbish, by your logic, overhead busbars in outdoor substation compounds will fail and copper transformer tails on overhead power lines will fail too. The oxidisation is a thin layer on the outside of the copper. The connection between joints will be mechanically sound whether green or not
@10Flat3 жыл бұрын
In many neighborhoods that copper would be vandalized and scrapped
@michaellim41656 жыл бұрын
Why a reupload?
@Techmatt167Official6 жыл бұрын
Michael Lim it’s a shortened version
@frequencywatchers Жыл бұрын
My "Good Practice" Is To Just Spray Salt Around TThe Grounding Rod. IDo That For My Areals And Antenna Grounds
@ArmandoRamirez-j7w23 күн бұрын
In running the cable thru the attic pose a fire hazard when the cable is electrified by a lightning strike.
@justin09576 жыл бұрын
Good thing this smart homeowner put a lock on his panel/main disconnect to the house in case of an emergency
@afh76896 жыл бұрын
Well 1) the real question is why is the panel outside and 2) this is a reupload and was probably filmed years ago when metal prices were higher and metal theft more common...could be to deter theft.
@JP-rf7px2 жыл бұрын
The 2020 NEC requires a service disconnect OUTSIDE the home. This is so the Fide dept can shut off in case of a fire before they put water on it. Not sure if they can prevent you from locking it tho. FD should have bolt cutters on the truck if needed.
@supersparksbros3 жыл бұрын
What happened to bonding lightning ground to electrical ground and incoming gas. And was there any metal within 6ft of the cable in the attic area. Cause if so it will need bonded as well. Pretty sure I saw the name Maxwell on the equipment. Big outfit out of OHIO.
@apkasidar6333 жыл бұрын
Good eye, typical for big outfits - screw up the highest number of homes, opening a market in the future for further upgrades/fixes, which they are already way ahead of you on and will see you in the future for again lol. From concrete, stucco, to lightning rods, never trust a big name that is always looking for new employee's
@magsasaka10273 жыл бұрын
The NEC states that the ground and the neutral buss must be bonded. Here in the Philippines we had problems with the ground conductor
@magsasaka10273 жыл бұрын
ground conductor of the utilities company had problems reaching the ground sometimes. I had to run a neutral to a good grounding conductor so that we will have power. (We have 240-0 line, single phase 13.8 KV feeding the XFMR) One big problem we experienced with bonding the neutral bus and my ground bus is that when that situation happen, the neutral load of the XFMR will be coursed thru my neutral conductor into my grounding system and burn it up.
@apkasidar6333 жыл бұрын
@@magsasaka1027 Very interesting, thanks for sharing that!
@RobertLeBlancPhoto6 жыл бұрын
I'm not impressed with how they seal the holes they made at the roof peak with just blobs of caulk.
@teodelfuego3 жыл бұрын
Roofing asphalt, not caulk
@Efferheim3 жыл бұрын
Flammable stuff. Right on the least conductive part of the “system” they have.
@stephenshelton426711 ай бұрын
Generally lightning is accompanied by rain, so wouldnt that help the grounding rods in dissipating that power?
@anorthosite9 ай бұрын
Depending on the soil. It could percolate through sandy soil fairly quickly but clay would not perk well. And T-storms generally last a several minutes to an hour, but it would likely take much longer for the subsoil to be wetted down 10-20 feet by the accompanying rain.
@rodparker45145 жыл бұрын
The rods charge the passing rain clouds to prevent a strike , believe it or not .
@KamenKr2 жыл бұрын
Well, if a lighting hits the rod, the copper cable will get hot and it can couse a fire because it has a close contact to the wood. Is this true?
@rolfsinkgraven6 жыл бұрын
Why inside? that sounds like a fire hazard too me if it strikes.
@STXVIEC6 жыл бұрын
how? its simply a ground wire that sends the lighting to earth
@veggiejacksgarden26306 жыл бұрын
I'm thinking the same thing. It's unsheilded copper against wood. With a billion volts passing through it, that copper is bound to get hot. I've also wondered why churches put rods on steeples. Total lack of faith if you ask me ;)
@MsUltrafox6 жыл бұрын
That has never been proven to be dangerous. All the houses that had it were burned down so no evidence remains. . High voltage and high wattage in a wire will heat it up so yeah having that inside your house is stupid AF.
@tresslerj19855 жыл бұрын
You are talking a fractions of a milliseconds. There will be hardly any resistance or time to heat up that conductor.
@bum-edwhu664 жыл бұрын
@@STXVIEC unless if finds a path of lesser resistance within your property, totally dangerous
@mohinderkaur66712 жыл бұрын
why stop at 20 ft? go the full 100ft!
@kd5j6 жыл бұрын
There are so many things wrong with this video. If lightning hit the rod on the roof there is no guarantee the strike will follow the ground line in the attic and it could jump to a lower impedance path in the house and cause greater damage. The two grounds used to make a 20 ft rod MUST be welded. The ground line MUST be welded to the ground rod. All ground rods MUST be connected together and in turn be connected to the ground at the service entrance of the house. He said cable, tv, phone, etc has surge protectors but those must be grounded at the service entrance also. I bet they weren’t. I don’t see how this installation passes NEC.
@angelabenschop14636 жыл бұрын
Welded AY LMAO
@erictold5 жыл бұрын
Sorry. I stopped reading at "ground at the service entrance". omg. It will fry computers, tv, frig, a/c. There is also guarantee that the lightning will follow the ground line as it has lower impedance than anything else.
@monkeyhead43155 жыл бұрын
Local code supersedes the NEC
@markwarrington27886 жыл бұрын
12 inches is a small one.
@frequencywatchers Жыл бұрын
That Copper Will Be Stolen The Next Day ! :D
@curiosity23146 жыл бұрын
I would be happier with a glass / combo insulator myself. You would in my mind have to be careful about what this wire in the attic gets close to that is grounded. Nails or screws should not be an issue as they should not be ground potential. It's all about attraction here, wood should not provide that but it's all about the ground potential. Better to have the wire in the attic encased and also grounded.
@jasonmorehouse37566 жыл бұрын
that wire is the ground, and the path of least resistance
@ThePhilandPam6 жыл бұрын
Interesting, might sound like a daft question but is there a very high incidence of strikes in your area of the US, we’re in the UK and have never come across a domestic property strike although they must happen. Thanks for sharing 👍
@TaylorHockeyVideo4 жыл бұрын
I can't speak to whether they are direct strikes but here in Atlanta, GA we do see a lot of device damage as a result of lightning during storms. I do IT and other technology consulting so I am called in to replace equipment damaged during thunderstorms. I have an electrical\electronic\scientific background but I can't speak to the pathways involved by the lightning, maybe through the power transformers, or wet ground and wet homes, I'll have to think about that, but the result is pretty clear. Lots of damaged computers, routers, TVs, audio amplifiers, whole house audio components and so on. The guys touch on indirect hits just slightly at about 3:20 when they do the Breaker box surge protection device. A friend of mine lives in a wooded area and has seen a receiver, TV, DVD player, and a multichannel amp (twice) get hit from two storms within roughly the last year. We're about to do some serious prevention work in the near future.
@magsasaka10273 жыл бұрын
My wife's parents house is on a mountain top, and everytime there is a thunderstorm, they had to turn off their main switch (30 amp fusible switch) otherwise, the fuses will be busted, and also bust up their TV receiver.
@Ruffbone853 жыл бұрын
I live near the Tallahassee Florida area and it's definitely one of the worst places in the US for lighting strikes but I only recall a couple houses being destroyed by lightning over the years.
@jackiesauter22 жыл бұрын
I live in Oklahoma (tornado alley) and we had an indirect strike around 2015 at our house. Fried several electronics and we had a hefty repair bill for our air conditioning unit. Just saw on the news that lightning struck an apartment building through an air vent and busted a toilet into smithereens! Luckily there was no fire!
@dharam1082 жыл бұрын
Florida is constantly getting strikes!
@larryy6467 Жыл бұрын
How much would this cost?
@rodneysammons5544 Жыл бұрын
Today the copper is more than the labor.
@sokkimsan5794 жыл бұрын
Hello could you explain me about how we calculate conductor size for lightning ?
@waynet83273 ай бұрын
They use a PVC pipe ouside of the house to put the copper wire inside of it. My question is, why not use a PVC pipe to put the copper wire inside of it in the attic also?
@UltraSwift4 жыл бұрын
Netflix: Are you still watching? Someones Daughter: 2:57
@phoenixlovell5594 жыл бұрын
Yep
@Skammerd6 жыл бұрын
Was the electrician off today? Why's Roger there?
@garyp02086 жыл бұрын
S Rx The fact checker was off
@xarptwin2 жыл бұрын
What is the tool used to cut the threaded rod? at 1:30
@bagofchicken2 жыл бұрын
Cordless bandsaw. Very handy for cutting rod and conduit in the field when an extension cord is impractical.
@WiSeNhEiMeR-1369 Жыл бұрын
HOWdy T-O-H, ... Thanks COOP the WiSeNhEiMeR from Richmond, INDIANA ...
@peterbrookman41342 жыл бұрын
In reality having a lightning protection system on a structure does attract lightning strikes due to the air terminations creating a larger streamer compared to a structure that is non-conducting. the step leader from the cloud is looking for a ground streamer to make a connection. it would be interesting to see if the spacings of the air terminations comply to the correct rolling sphere protection radius.
@siriosstar47896 жыл бұрын
Piercing the ridge is a really bad idea. I would be more concerned about the roofing cement failing and causing a leak ,than a one in a million chance of a lightning strike.
@tarkiss4 жыл бұрын
I thought the protection consisted and driving lightning away from your house, no making it run right through it. 🤔
@Wc_Ritchie3 жыл бұрын
It's to drive lightening to the ground thru the shortest route possible
@Efferheim3 жыл бұрын
This is a horrible system. It’s absolutely atrocious.
@alamgirparvez78583 жыл бұрын
How many misters this device cover??
@benguythomas3 жыл бұрын
It might be cheaper to build another bigger house next door!
@kamilkuzmicki16876 жыл бұрын
Isn’t this a re upload?
@willrich64502 жыл бұрын
Unfortunately Bens house was struck by lightning and burned to the ground.
@armando926 жыл бұрын
Why the wire inside the attic doesnt have any insulation? I mean there is like zero chances to have someone touching the wire when a lighting hits but its there
@RedBullishTrading6 жыл бұрын
It’s lightning cable. Do you think thin insulation will protect you if you’re grabbing it? Probably not. Lightning will go right through it. Tens to hundreds of millions of volts.
@brunonegraozica54593 жыл бұрын
What happens if someone touches the rod cable while a lightning is passing through it?
@Wc_Ritchie3 жыл бұрын
It's rip for them
@nathandesormiers70053 жыл бұрын
Just don’t do it
@carlossaroufim2 жыл бұрын
You see your creator sooner than planned.
@JP-rf7px2 жыл бұрын
Someone will say "Oh look, Bruno's extra crispy today"!
@smileydavis73 Жыл бұрын
Curtains. Curtains I tell ya. Curtains.
@tomkeating656 жыл бұрын
Lightning ever hit twice in the same spot?
@Casey_Jones6 жыл бұрын
Yes, it is possible. The "lightning doesn't strike twice" saying isn't accurate
@JP-rf7px Жыл бұрын
Hits the Empire State building all the time!
@JP-rf7px Жыл бұрын
Not in this case because after the first strike, this house will burn down and not be there for the second strike!
@TheStandardBearer4 жыл бұрын
Very informative, thank you. #LoveIsNotTourism
@arthurmead53413 жыл бұрын
What?
@derekjp60439 ай бұрын
Nice - it felt so scripted. I suppose it's easier for them to move the video forward with super short, scripted scenes. Effective video!
@edwardsandoval521 Жыл бұрын
How about replacing that old air conditioner!
@Boeing767DriverAA3 жыл бұрын
Running the cable inside the house ridiculous
@teodelfuego3 жыл бұрын
No, but your strong opinion coupled with your scientific illiteracy is pretty funny, and sad
@frequencywatchers Жыл бұрын
Why People Don`t Use Diodes To Put The Electricity Into Ground And Not From Ground? A Lot of People Get Sensetive Devices Killed By The Static Electricity That Comes From ground And Thats Why I put In parallel so all the unwanted electiricty goes into the ground and not the other way around, i put few diodes with diferent values in paralell so if one blows, the another one will work and if lighttning strikes , they will be fine i guess. or am i wrong? it works good for the computer because without grounding diodes, the computer froze many many times a month, now when i made the diodes to ground from pc, it have never hapened not even once.
@seawcia3925Ай бұрын
Hi I would like to know is it due to devices still plugged on and not unplugged and switched off that static electricity destroys them?
@smileydavis73 Жыл бұрын
oh my.......🤣 ...this old house.
@MetroDET20116 жыл бұрын
Make sure to also draw your anti seabear circles. What a waste of money lol
@wrenchdoozer6 жыл бұрын
My anti-sea-bear circle works great. I believe everything I read in Fake Science Monthly. lol
@ericspda6 жыл бұрын
Houses burn down all the time from lightning. It’s super unlikely, but it’s not like it’s some made up thing. Some people worry about things that are statistically outrageously unlikely.
@Pie4life1236 жыл бұрын
Ur dumb it hit his house already should have had it done before he moved in would have paid off already with that 1 strike
@edancummings77384 жыл бұрын
I've seen strikes in two different homes in my life, and resulting sensitive electronic damage both times. It's not made up and isn't as rare as you think, especially if in the Southern states.
@bob-ny6kn6 жыл бұрын
Where is technology? Why aren't HUGE, fast-charging (the speed of lightning) capacitors in every house? Imagine: one lightning strike and never another electric bill… for the entire street.
@10Flat3 жыл бұрын
Nice job but theoretically a waste of money in this case. What are the odds of lightning striking twice.
@SteveBueche10276 жыл бұрын
I thought the idea was to shed the lightning away from your house? This appears to bring it into your attic before disbursement to the ground. (?)
@ClicketyClack6 жыл бұрын
Lightning will strike where it wants. It is not possible to redirect it away from a structure. Unless you live next to the Eiffel Tower perhaps.
@bum-edwhu664 жыл бұрын
@@ClicketyClack no you redirect it AROUND the structure, not through it
@JP-rf7px3 жыл бұрын
@@ClicketyClack Sure it is. By providing a more attractive (lower resistance) path to ground. If you want to see real lightning protection, look at a space launch pad at Cape Kennedy. See those four towers around and higher than the vehicle. With wires run between them.That's how it is protected in Florida.
@jimmyjayant80722 жыл бұрын
Excellent Video. Extremely helpful.
@eduardovieira52925 жыл бұрын
Good Job. There are many people here that doesn't have knowledge about electricity and standards and writes a lot of bullshit...
@bennywolf21696 жыл бұрын
The guy @ 1:00 is doing a bad job of hiding the fact he is reading a script lol
@dcentral5 жыл бұрын
They say lightning rods don’t attract lightening and it’s an old myth but if these rods don’t attract lightening then how are they expected to always work? What’s the guarantee that lightening will hit a rod in a specific place on the roof and not the rood in between the rods if they don’t attract? Logic dictates that for this system to always work, it must attract lightening to eliminate randomness of the strikes on the roof.
@portaadonai6 жыл бұрын
Keep in mind that while this makes a strike on your house safer, it also increases the chance of lightning striking your house in the first place. This system is probably more important if your roof is higher than most other objects anywhere nearby, like if your house is on a hill or a two story among single story homes.
@reactionsb12 жыл бұрын
Those aren’t actors, it’s a real interaction. 🙄
@MrRW883 ай бұрын
All the morons in the comment section if wood was conductive the entire house would catch fire when lighting strikes. The conductor is mounted on wood conductor being a conductor will carry the charge. And send it to earth hence the grounding electrode system. Excellent video
@oby-160711 ай бұрын
I think this was mislabelled. This should have called Everything Wrong With This Type of Lightning Protection. Routing a cable through the attic-wrong. Steel threaded rod connecting the point on the roof-wrong. Ground rod only 8 feet in length -wrong. No checking for utility lines before driving rods into the ground-wrong. No series of lightning rods in the ground connected with copper cable-wrong. etc., etc. .
@spartan150x3 ай бұрын
I really dont like this install Taking down old barns with lightning rods everywhere the cable mounted it was done with porcelain
@jcschwarb Жыл бұрын
Terrible idea to place high current and high voltage inside the house. This is against NEC best practices. That company should be fined. Great way to burn your house down.
@jonathancabreragauto14075 жыл бұрын
#cmcesertec
@billyandjohnny77346 жыл бұрын
P
@billyandjohnny77346 жыл бұрын
P
@purpleidea6 жыл бұрын
This is a repost.
@maakjar6 жыл бұрын
Someone should tell him that a lighting rod prevents lighting. It’s primary function is not to “disperse the lightning into the ground”
@jej34516 жыл бұрын
A lightning rod doesn't prevent lightning. It can attract it, though, if it was going to strike nearby. So he's wrong, but not for the reason you think.
@augustreil6 жыл бұрын
@@jej3451, maakjar, You both are wrong. Lightening rods do not prevent lightening strikes. The wire just gives it a direct path to earth. Also, the rods only attract a strike if it is close enough to hit the ridge of your building, and it's much better to direct it to earth, which is a natural ground.
@jej34516 жыл бұрын
@@augustreil You said nothing that contradicted me.
@SSMJWolf6 жыл бұрын
Waste of money
@SSMJWolf6 жыл бұрын
@@theclueguy3388 and the chance of getting hit by lightning is very very very very low
@STXVIEC6 жыл бұрын
a cheaper alternative is to just install whole house surge protector
@AndreasKoepkeAU6 жыл бұрын
@@STXVIEC did you watch until the end? They installed a whole house surge protector as well as the rods
@pilotguy11416 жыл бұрын
When your house is struck by lightning and it's burning down can you post a video of it so we can laugh.Report highlights. During 2007-2011, U.S. local fire departments responded to an estimated average of 22,600 fires per year that were started by lightning. These fires caused an average of nine civilian deaths, 53 civilian injuries, and $451 million in direct property damage per year
@theclueguy33886 жыл бұрын
JC_wolf 64 He made it apparent that it’s happened to him before
@tjam42296 жыл бұрын
He said adding the rods won’t increase lightning strikes to his house...that it doesn’t “attract” lightning....Then why does a tower get struck more than anything around it? It’s the same principle...I think the odds are greater that his house will get struck more “with” the rods than “without” the rods. The lightning is looking for the easiest way to get into the earth. I think the guy is lying so his business doesn’t get struck.
@qwerdssa48056 жыл бұрын
T Jam it’s more about height instead of material, a tower attracts lighting because it’s the highest point of that area. In this case I don’t think the extra feet would significantly attract more lightning to his house
@xvx48486 жыл бұрын
Why do you need lighting protection? Wood is a horrible conductor of electricity. Lighting striking houses is extremely rare.
@ClicketyClack6 жыл бұрын
Everything is a conductor if you push enough voltage through it. The guy in this vid already had one strike that fried all his appliances.
@MiguelVicoR6 жыл бұрын
Dude use isolated cable! don't press the raw copper into the wooden beams! Also, considering lightning rod mechanics, why not put it away from the house!?
@RedBullishTrading6 жыл бұрын
Miquel Vico why not? What do you mean isolated cable? Do you mean use insulated cable? If you put the rods away from the house. Then the lightning may still strike your house and not the rods.
@Fusiongearz6 жыл бұрын
Insulated cable would melt and be a higher fire hazered than bare wire.
@augustreil6 жыл бұрын
Insulated, Non-insulated, makes no difference.
@MiguelVicoR6 жыл бұрын
@@Fusiongearz Melting rubber is a barrier between white-hot copper and dry wood, not a perfect barrier, but at least the heat sorce ain't being mechanically pressed against the fuel sorce.
@StoneE46 жыл бұрын
_Better to remain silent and be thought a fool than to speak out and remove all doubt._