How to install a type 2 surge arrester into a distribution board.
Further details found in the SANS 10142-1:2020 wiring standard - The Wiring of Premises Part1: low voltage installations.

Пікірлер: 40
@BespokeNumberPlates
@BespokeNumberPlates Ай бұрын
You are one of the best ever found in this channel
@user-yv6vx2fd5r
@user-yv6vx2fd5r 11 ай бұрын
very good explanation but we need more
@dulajohnstone5704
@dulajohnstone5704 2 жыл бұрын
Good Day to you Sir. I'm back again after 8 months lol. Thank you for the simple yet very clear explanations. Could you please do a 3 phase surge arrestor installation using the same method as you've shown in the single phase method thank you so much for your valuable time.
@sandhufarm286
@sandhufarm286 Жыл бұрын
🐜🐜
@iLink_LTD
@iLink_LTD 6 ай бұрын
Very helpful and detailed explanation, thank you!
@yaseenbenjamin5197
@yaseenbenjamin5197 Жыл бұрын
Thank you for your detailed explanation. Very useful
@louismathews6831
@louismathews6831 2 жыл бұрын
Awesome Video, thank you
@andrew39454
@andrew39454 Жыл бұрын
I think u get the wrong point about SPD need over current protection device (MCB or fuse). It is to isolate the SPD from the DB system if SPD fail, fault or damage. So you need an extract MCB or fuse as over current protection to connect between the Main MCB and the SPD, not directly connect the SPD to the main 63A MCB. Actually in current situation over current fuse disconnector is prefer than MCB, because you don't want the MCB in between SPD and Main MCB trip during lightning strike , you want the SPD to arrest the lightning to channel it to the ground, so fuse disconnector is prefer, that is why among all the SPD catalogue they normally emphasis fuse disconnector before SPD, not an MCB.
@tonybrock5288
@tonybrock5288 Жыл бұрын
I'm a DIY'er and have always had a preference for building a DB Board from left to right as you show. It's like reading 😀. However I see in some standards that Neutral should always (understandably) be on the "outside". So, a Main Switch with "L" and then "N" on the right, should always be mounted on the right of the DB board. What is the ruling in SA?
@siphokumalo7550
@siphokumalo7550 Ай бұрын
Hi, just a question. If I install a surge arrester in the db board, is it necessary to have protection for individual items
@education9135
@education9135 2 ай бұрын
And I've seen that some or most SPD they don't specify the current, say for example I want to use 63 amps how will I know that it is 63 amps. And also how long can a SPD run before damaged.
@mahlekojoni
@mahlekojoni 10 ай бұрын
THANK YOU SIR 🤓
@mlondenimakhaye8634
@mlondenimakhaye8634 Жыл бұрын
Very useful 👌
@mashundiy
@mashundiy 4 ай бұрын
Will single pole spd on load be enough? Or is it better to use 2 pole on both load and neutral?
@ebrahimseedat5554
@ebrahimseedat5554 2 жыл бұрын
Sir thank you so so much for your videos! Need to ask: If the light on my surge arrester is not completely off but is slightly faded when comparing to my other (same) surge arrestors.... Is it still okay to use or should I replace it?
@education9135
@education9135 2 ай бұрын
Some double poles SPD they connect live and neutral on incoming power then earth on neutral side of outgoing power. Some they put live on both incoming power then earth on outgoing power, what's the difference. And also comparing it with single pole SPD.
@markvanner1110
@markvanner1110 7 ай бұрын
Hi sorry to be negative but is that board wired compleaty backwards. Eg should the main isolator not be on the right and rccd next to it with bus bars feeding the bottom of the mcb s. Like wise the out going cuicuits coming out of the top of the mcb s not the bottom. Look s like a very over complicated solution for a standard instalation to me.
@flinfaraday1821
@flinfaraday1821 Жыл бұрын
If this is a sub-db, and the main db already has overcurrent protection, do I still need to to include an overcurrent protective breaker in this db before the surge arrester?
@sanelengcobo404
@sanelengcobo404 5 ай бұрын
Awesome ❤
@princekhumalo7737
@princekhumalo7737 Жыл бұрын
Hi Anthony. I would love to learn the solar installation, especially the connection to the db box. Do you know any course i can attend or on the job learning program?
@dulajohnstone5704
@dulajohnstone5704 2 жыл бұрын
Does the Surge arrestor on the Main DB also cover the sub DB feeding from the Main DB?
@JAG_UAR
@JAG_UAR 2 жыл бұрын
type1+type2 uc 275v or type1+type2 uc 330v , sir which spd is better, for homes?
@ngocehgayabebas2118
@ngocehgayabebas2118 2 жыл бұрын
Does it protect tv from internal surge, like start-off surge motor dynamo or refrigerator?
@ngocehgayabebas2118
@ngocehgayabebas2118 Жыл бұрын
@hardstyle905 thank you
@itsalive7309
@itsalive7309 2 жыл бұрын
This is probable a stupid question but anyway.... I have a CBI Type 2 Surge arrestor QFL-N-2(13). The diagram printed on the device shows N wired on the top left terminal and L wired on the top right terminal , with Earth bridged across the bottom terminals. However, the electrician has wired it so that Live (Red) is connect to the top left terminal (N in the diagram) and Neutral (black) is connected to top right connector (L in the diagram). According to the diagram, this the wrong way around. My suspicion is confirmed by the fact that the surge arrestor light is off. Am I correct and if the diagram says N is left, then N should be connected on the left? Or doesn't it matter and I need to go back to Reading 101?
@sajidmohammad3190
@sajidmohammad3190 3 ай бұрын
L or N doesn't matter if it has two separate identical blocks. If it is a 1P spd, then L & N will matter.
@SnowyPe
@SnowyPe 2 жыл бұрын
Good info..thanks
@Alec_Aldawg
@Alec_Aldawg Жыл бұрын
Why does it need an over current protector if it’s not drawing current?
@ecologicaltime
@ecologicaltime Жыл бұрын
in case a fault occurs inside.
@royalarmy1837
@royalarmy1837 Жыл бұрын
Good day Sir. What size of Earth cable is suited for a 600vDC SPD 20kA?
@kza691
@kza691 2 жыл бұрын
Are these one time use or can they be reset?
@flinfaraday1821
@flinfaraday1821 Жыл бұрын
They work until the flag/indicator shows red/replace, then you throw it away and install a new one.
@bosuglosalifulongi6406
@bosuglosalifulongi6406 2 жыл бұрын
The bent busbar is not insulated. Is it okay to leave it as it is?
@aphaseelec
@aphaseelec Жыл бұрын
No it needs to be insulated
@ashwinshadygold6277
@ashwinshadygold6277 2 жыл бұрын
Can you do down lights or outside Piller lights
@Charles.parker
@Charles.parker Жыл бұрын
Can we connect output of type 2 spd to neutral instead of earth?
@MuhammadARPeer
@MuhammadARPeer Жыл бұрын
No
@srinivasanragavan5737
@srinivasanragavan5737 Жыл бұрын
Where the surge attestor available
@namzy410
@namzy410 2 жыл бұрын
16mm2 cable?
SPD INSTALLATION IN A CONSUMER UNIT - HOW TO and THE BASICS
11:46
LEARN ELECTRICS
Рет қаралды 95 М.
王子原来是假正经#艾莎
00:39
在逃的公主
Рет қаралды 15 МЛН
Can This Bubble Save My Life? 😱
00:55
Topper Guild
Рет қаралды 86 МЛН
Nurse's Mission: Bringing Joy to Young Lives #shorts
00:17
Fabiosa Stories
Рет қаралды 4,6 МЛН
Люблю детей 💕💕💕🥰 #aminkavitaminka #aminokka #miminka #дети
00:24
Аминка Витаминка
Рет қаралды 499 М.
Which Type of SPD should you use? ⚡
5:41
Axis Electricals
Рет қаралды 6 М.
Surge Protection Devices - Part 1
24:01
John Ward
Рет қаралды 214 М.
The SY2-D surge protector (SPD)
21:52
David Savery Electrical Services
Рет қаралды 139 М.
COMO MONTAR CUADRO DE PROTECCIONES FOTOVOLTAICAS - INVERSORES MONOFÁSICOS
11:22
ENERGY SAVING SOLUTIONS
Рет қаралды 204 М.
王子原来是假正经#艾莎
00:39
在逃的公主
Рет қаралды 15 МЛН