How To Diagnose & Repair Hayward Summit Pool Heater Heat Pump

  Рет қаралды 30,817

Queb

Queb

Күн бұрын

Пікірлер: 150
@SteveDiLoreto
@SteveDiLoreto Жыл бұрын
super informative and helpful! perfect use of the term fuckery also!! thanks
@almatindall1600
@almatindall1600 20 күн бұрын
Great explanation and diagnosis technique. How do you replace the pressure switch hose? Where can you access the other end? Thanks in advance
@justinhussey2376
@justinhussey2376 5 ай бұрын
@QuaabQueb, awesome video dude. My buddy has a similar unit (Hayward Heatmaster) He didn't properly store it during the winter and the cpvc split. Does the whole coil have to be replaced? Worth saving?
@QuaabQueb
@QuaabQueb 5 ай бұрын
@@justinhussey2376 Probably not. I would try the easiest and cheapest thing first. Try and sand down the split. Get a section of 2" pvc pipe, cut a slot on and then warm it with the heat gun to open it up, you are making a sort of "patch" you can slide over the split pipe and glue it on with pvc primer and cement. It may hold for a year or two. You can try and find a donor unit on marketplace. People often give them away for free when they crap out. Keep in mind the titanium heat condenser coil is running through the cpvc coil. You will need an hvac technician to come pull a vacuum on the unit, disconnect the coil, install the new one and recharge. That service call may be worth more than the cost of the unit unless you know a guy in the field
@justinhussey2376
@justinhussey2376 5 ай бұрын
@QuaabQueb thanks man, he decided to get a new one afterward, but when I did look at it, the PCV was totally split apart in a few places. Appreciate your response
@tracikucherry6600
@tracikucherry6600 2 жыл бұрын
Great information video!! My unit is a lot like this one and it will start up, run for about 30 seconds and then shut off. Any idea why it’s doing this and what I can check and troubleshoot on it?
@mosesvani5409
@mosesvani5409 Жыл бұрын
U are either overcharged on refrigeration or a restriction in the txv
@georgesdufresne4544
@georgesdufresne4544 7 ай бұрын
maybe the input and output of water supply are inverted?
@ÉricVigneault-h3k
@ÉricVigneault-h3k 7 ай бұрын
Thanks for the video it was very informative. My question is I would like to run my Sum 4 with a variable speed water pump, but the water pressure switch is triggering a “low flow” error and won’t engage the heat. I’m thinking of replacing it by a digital programmable water pressure switch which would allow me to program a pressure range for it to close and engage the heat. Obviously it can’t be too low ‘cause I don’t it to overheat, but what do you think? Or do you have any suggestions?
@louishildebrand4785
@louishildebrand4785 8 ай бұрын
Thanks! very useful and complete!
@madeleinedelson4109
@madeleinedelson4109 2 жыл бұрын
Amazing video! I've got a Hayward that looks nearly identical to this. Fan works fine, no error codes, but the compressor tries to kick on and it makes a loud buzzing noise for 3 seconds and then nothing. Doesn't sound like the compressor kicks on at all, so no heat. Any ideas? Could it be the compressor capacitor? why wouldn't it have any error codes? TIA
@QuaabQueb
@QuaabQueb 2 жыл бұрын
Yes could be exactly that. Error codes are only thrown by the sensors. The unit is just simply not turning on.
@madeleinedelson4109
@madeleinedelson4109 2 жыл бұрын
@@QuaabQueb Not the capacitor... tested a perfect 79.7 microF... replaced it anyways and didn't solve. Noticed a loud buzz is actually coming from the contactor switch, so now I'm wondering if that's it? I ordered a $12 replacement arriving in 2 days... let's see.
@madeleinedelson4109
@madeleinedelson4109 2 жыл бұрын
Also wasn't the contractor; replaced it, and still no luck. I'm stumped. I check the continuity of all three prongs on the compressor in all combinations... all good. when compressor tried to kick on I get a voltage drop from 246 to 200 or so, but I assumed that is normal for startup... just mine won't start up. any other ideas on what to check?
@stephenremillard9462
@stephenremillard9462 2 жыл бұрын
@@madeleinedelson4109 I have exactly the same issue. Changed capacitor, didn't do the contractor yet. Resistance check gives me around 3 ohms in all combinations. Not sure if it is normal. When compressor try to start, the breaker trips. Do you have any suggestion?
@michaelschwarz5008
@michaelschwarz5008 5 ай бұрын
Great video. Thank you
@cybertech3DStudio
@cybertech3DStudio Жыл бұрын
Great video, my unit can't start the fan alone, I have to help it. Is it possible that the capacitor is the problem?
@jean-francoisfortin710
@jean-francoisfortin710 3 жыл бұрын
Great video, will help me look for the issue on my Summit. Any tips of what I should look at first? I get an F5 error code but it's not cold outside at all. The compressor starts but the fan doesn't?
@MrLuckyLaChance
@MrLuckyLaChance 3 жыл бұрын
you're getting the FS because the compressor is running and the fan is not dissipating the cold out of the unit. It could be a capacitor could be the fan relay in the board or it could be the fan. Since this was from three months ago im assuming youve already made the repair or replacement
@marc-andreodam4034
@marc-andreodam4034 2 жыл бұрын
Bonjour Jean-François, j'ai le même problème actuellement F5 ou FS ... as-tu été en mesure de résoudre ton problème ? Si oui, as-tu un conseil pour moi ? Merci
@angelikamariae
@angelikamariae 3 жыл бұрын
Excelent video!! Thanks for sharing.
@eduardopena3513
@eduardopena3513 Ай бұрын
Hello m'y friend, could you help me with a problem with a Hayward motor pump that has low pressure, we have to put some kind of gas in it, we changed the low pressure switch or valve and it still does not turn on and it indicates low pressure thank you so much
@ceciliamiske8427
@ceciliamiske8427 2 жыл бұрын
The clear tube running from the pressure flow switch came off the end that connects to the pipe in the back…looks like the piece that was connected to the pipe broke off….how would I repair that? It looks like something was kinda just screwed into the pipe with a nipple like thing coming off the top for the tub to slid over….does that sound right?
@QuaabQueb
@QuaabQueb 2 жыл бұрын
Yes it's a small barbed end You would need to get a new pressure switch assembly. The hose is also held on by a crimp clamp.
@St4r_girly
@St4r_girly 2 жыл бұрын
So this happened to me as well yesterday! How do I get to that back pipe? And where can I find the pressure kit assembly I’ve looked all over the internet. I have a Hayward summit xl
@ceciliamiske8427
@ceciliamiske8427 2 жыл бұрын
@@St4r_girly so I was actually able to find everything I needed at Lowes….my switch was still good so I just got the same size clear tubing from plumbing section in Lowes and found a brass barbed fitting in the plumbing section and used epoxy to kinda glue it back into that pipe…drilled out the hole so the brass fitting would push down into it….connected other end to pressure switch fitting….BAM the heater kicked right on!!! Hope this helps ya!! I took the top off where the fan is…got to it that way….definitely a stretch but easier to see everything…
@LutherWikle-w4n
@LutherWikle-w4n 11 ай бұрын
great video......my hay/summit xl140 is not sending signal to contractor coil.....not low on r410a, lp and hp and Flo all ohm out, no codes.....replaced board and contactor, ...when I turn it on, everything seems fine,,,,after 3 min, the flame indicators appear but does not energize the contractor coil......unit is less than 2 years old.....is there anything in the board setup I need to look at? I went through the setup as best I could...is not setup for remote etc. when I manually energize the contractor, comp runs and A/C grades react normally
@andreiispas9938
@andreiispas9938 7 ай бұрын
I have a TTI heater with the exact same control panel and electric components like the summit in the video. I get the FLO code although there is flow and there's no obstruction. I changed the flow switch and is still have the FLO code. I tested the switch with a meter by turning on and off the pump and the switch it works. I even shorted the terminals where the switch goes, and I still get the alarm. Any ideas???
@QuaabQueb
@QuaabQueb 7 ай бұрын
You shorted the terminals on the board where the flow switch connects? If so and the problem persists then there could be an issue with rhe board.
@jimccc9467
@jimccc9467 Жыл бұрын
I have a 3 year old just out of warranty Hayward HP21404T that has an issue. The other day it was not heating and panel read “Lo Flo”. It was shut off until today and when I turned it on it is now reading “HP”. I have read what the code means but didn’t know if you might have an idea based on age of unit. So far every Hayward component has failed and this was the last item with a problem but sadly now it’s out of warranty.
@moniquemiller2402
@moniquemiller2402 Жыл бұрын
Hi, the flexible piping on mine has leaks. Tried to put epoxy, silucone, flex tape ect...nothing holds. Can I just cut the leaking portion of piping and replace it with new one and fitings
@QuaabQueb
@QuaabQueb Жыл бұрын
If it is the main coil no, there is a tube that runs inside that where the refrigerant gas passed through. You cannot cut it.
@richie_waverider
@richie_waverider 2 жыл бұрын
I've got a a unit with no error codes, the fan is spinning, the water flow is good but it is not heating the water. I noticed there is no condensation water at the base on the concrete slab it sits on. it's 5 years old. I have just opened the unit to take a look but have not diagnosed anything and I'm not educated at all in this stuff. Any suggestions before the service technician gets here in 4 days?
@QuaabQueb
@QuaabQueb 2 жыл бұрын
Compressor is not coming on. Check all the common issues, contactor, capacitor etc..
@autismhelpinformationchann8351
@autismhelpinformationchann8351 3 жыл бұрын
Very helpful information
@josephwashington2125
@josephwashington2125 10 ай бұрын
I have a leak in the cpvc on the back side near the inlet and outlet, can i buy that type of pipe and repair it myself?
@QuaabQueb
@QuaabQueb 10 ай бұрын
Yes if you have enough room to cut it out and glue in a new section
@foxzpaws
@foxzpaws 6 ай бұрын
I have the same heater and it will shut off after around 3 minutes and it trips the breaker on my panel. I took it apart and nothing looked bad, can you provide any help? Thanks
@QuaabQueb
@QuaabQueb 6 ай бұрын
@@foxzpaws If it's setting the breaker then something is shorting. I would recommend using a clamp style meter to monitor the current and see if and where it's rising. You say it "runs" for 3 minutes. Is the compressor on for 3 minutes? Or is it setting the breaker as soon as the compressor kicks on.
@foxzpaws
@foxzpaws 6 ай бұрын
@@QuaabQueb I think it's kicking out when the compressor kicks in, because the fan and screen are operating fine but I'm not positive when the compressor is supposed to kick in. I appreciate the help, I have an old multi meter, maybe I will dust it off to see if there's a short.
@QuaabQueb
@QuaabQueb 6 ай бұрын
@@foxzpaws You would need a clamp style multimeter that you can clamp on the wires. If it's setting the breaker as soon as the compressor kicks on then it could be a seized compressor. It's possible it could also be a defective breaker
@neilgeens7052
@neilgeens7052 2 жыл бұрын
very good video i have a dream 12.5kw unit its has no display compressor fan running , copper pipe hot up to the heat exchange , i am gussing it may be the pcb because i have changed the display for a new device and still not working , water outlet to pool cold
@JP_Ross
@JP_Ross Жыл бұрын
@Instucablanator I also have the same problem here. Any clue on what it could be?
@pedrolavalable
@pedrolavalable 2 жыл бұрын
Great Video, I have to replace my sensor water temperature in my summit Pool Heater heat Pump. I buy the part SMX306000024 but i can't find where is it in the pump. Can you know where is it 6 thank you.
@QuaabQueb
@QuaabQueb Жыл бұрын
Just follow the wire from the controller.
@rodmzn007
@rodmzn007 3 жыл бұрын
very helpful and easy to understand ...
@dannelson7534
@dannelson7534 3 жыл бұрын
@ 9:14 in the video what psi of compressed air are you blowing into the LP switch??
@garyhall1035
@garyhall1035 3 жыл бұрын
How do I replace the master switch on a Hayward HP50-TA? Switch works, but is very hard to move. I suspect it's probably corrosion because it doesn't appear to be weather sealed in any way. I believe the newer ones have a clear flexible cover built in.
@QuaabQueb
@QuaabQueb 3 жыл бұрын
Just pushes out from the back side of the panel with some retention clips on the back side of the switch it self. The contacts inside may have melted. You can use any switch the same size and current rating. You can find them at local electronics stores. Just make sure the dimensions are the same.
@garyhall1035
@garyhall1035 3 жыл бұрын
@@QuaabQueb Thank you! I also posed the same question to Hayward on their official website over three weeks ago. Never got a reply, but today I received a new switch from Hayward with the notation, "warranty replacement." Life is good! Thanks again for your help regarding installation. I
@ronciccone7624
@ronciccone7624 3 жыл бұрын
Great Video: I have a Hayward Summit XL, entering 2 season of use. Fan runs but not getting at heat output at the inlet. Fan blowing cold air BUT I have not measure the delta T yet. Any suggestions?
@QuaabQueb
@QuaabQueb 3 жыл бұрын
If the fan is blowing cold air then the condenser coil must be pumping out heat to the water... These thermopump units are slow and can take a good week to get a large size pool up to temp. Especially at the beginning of the season.
@ronciccone7624
@ronciccone7624 3 жыл бұрын
@@QuaabQueb It actually was working. I realized later that the air was to dry to facilitate a good heat exchange. As humidity increased so did heat pump efficiency. Thank you for the help. Great Channel - shoot the bird ;)
@GabrielKolendrekaj
@GabrielKolendrekaj Жыл бұрын
So I had the white pvc pipe in the back of this unit explode, after the company opening the pool for me didn't open he valves and ran the pump causing a buildup of pressure. Is there a way to lift the copper surround on this unit to be able to get to the pvc pipe in the back and replace them? I'll pay for guidance not looking to get something free out of you, I know it's your job.
@danielherron3
@danielherron3 8 ай бұрын
Hi, I have a Summit_XL_Hayward, when I turn on the breaker the fan works, but the screen doesn't show anything and the water doesn't go warm. Does someone know what could be?
@QuaabQueb
@QuaabQueb 8 ай бұрын
The power supply to the control board. It could also be the display is not working or the board is defective.
@timdogsprincess
@timdogsprincess 2 жыл бұрын
I have a Hayward electric heat pump. It was tripping the breaker once in a while I would reset the breaker and it would heat and work with no problem. It did that a couple times and now the fan won't come on. I replaced the fan and the capisitors and it still won't come on any idea what it could be.
@QuaabQueb
@QuaabQueb 2 жыл бұрын
Something is shorting or pulling toomuch current.
@timdogsprincess
@timdogsprincess 2 жыл бұрын
@@QuaabQueb any idea where to start, I pushed coil contactor in and the compressor gets super hot really quick. I have checked all wiring and it looks good. I have power going to the fan.
@QuaabQueb
@QuaabQueb 2 жыл бұрын
@@timdogsprincess check the compressor windings with a multimeter. I have seen the pins blow out so look at them carefully to see if thru look burnt or damaged. Always be careful poking around in there as the capacitors can hold a charge for some time.
@timdogsprincess
@timdogsprincess 2 жыл бұрын
@@QuaabQueb will do I have checked the ones at the capacitors and the contact switch, they look good. I will check the wire connector right at the compressor.
@QuaabQueb
@QuaabQueb 2 жыл бұрын
@@timdogsprincess yes look up how to test compressor winding resistance. You can also use a clamp type multimeter to check the current draw of the unit. If it is pulling abnormally high current you know there is a problem. Remember the circuit breaker is an overcurrent protection device. It's function is to open the circuit if something is abnormal. Ex.: A direct short back to the source (not ground!!) , or an overloaded piece of equipment.
@waynelynds4355
@waynelynds4355 Жыл бұрын
I have no power to the front control board when I turned it on power is coming in but nothing on the control board
@caragannon2648
@caragannon2648 2 жыл бұрын
hey, so I have a Hayward heat pump. The fan runs., but when the condenser kicks on runs for about 30 seconds then bogs out. and then the lp come code comes on, tries all over again. Any ideas on what it could be? I changed the capacitor already.
@QuaabQueb
@QuaabQueb 2 жыл бұрын
Yes that is the low pressure error code. The causes are listed in the manual. Usually it is because it is too cold outside.
@caragannon2648
@caragannon2648 2 жыл бұрын
@@QuaabQueb yeah i looked at them but too cold isn't a problem because I live in Florida . i am thinking that I might have to bite the bullet and get a new heater
@caragannon2648
@caragannon2648 2 жыл бұрын
thank you
@QuaabQueb
@QuaabQueb 2 жыл бұрын
@@caragannon2648 page 10: hayward-pool-assets.com/assets/documents/pools/pdf/troubleshooting-guides/HeatPump-troubleshooting-guide.pdf
@guilannieraymond3956
@guilannieraymond3956 5 ай бұрын
bonne video! j’ai apris plein de truc! j’aurais aimé voir comment reparer le petit tuyau qui donne le flow. le mien a lchaet coté sensor
@QuaabQueb
@QuaabQueb 5 ай бұрын
@@guilannieraymond3956 Vous pouvez le remplacer par un tuyau du même diamètre
@geolopez4375
@geolopez4375 3 жыл бұрын
Question for you my unit it's reading high pressure and stopped working. What do you suggest I check in order to fix the problem?
@QuaabQueb
@QuaabQueb 3 жыл бұрын
Check the service manual it lists all the possibilities for high pressure fault. In a rare case it could be a bad switch, or it can be over charged
@geolopez4375
@geolopez4375 3 жыл бұрын
Thank you
@gbanks
@gbanks 3 жыл бұрын
@Chargero wonder if you can help me trouble shoot? My heat pump will not turn on at all. I have power. My display will not turn on and if I press the bypass coil to give power directly to compressor and fan nothing happens. I can see that power makes it across when I press the coil in.
@QuaabQueb
@QuaabQueb 3 жыл бұрын
Might be bad contactor.
@gbanks
@gbanks 3 жыл бұрын
@@QuaabQueb You think so even if I get a reading once I press the bypass coil in? Wouldn't that mean it is getting power? Although it does not turn on the compressor or fan.
@QuaabQueb
@QuaabQueb 3 жыл бұрын
@@gbanks The contactor is the only thing between the mains lines coming in to the unit and the compressor/fan. The Control circuits are powered by a transformer that drops 120V to 24V
@gbanks
@gbanks 3 жыл бұрын
@@QuaabQueb Replaced the contactor. Still no display and compressor/fan not turning on. Thinking to replace the transformer next.
@QuaabQueb
@QuaabQueb 3 жыл бұрын
@@gbanks Test it. Check voltage output on the secondary. Follow the terminals from the transformer to the board. But when you depress the contactor it should kick on the fan/compressor. You are effectively bypassing the control circuit that energizes the contactor coil. Are your fan/compressor capacitors good? I have seen power surges blow these units. Typically a ruptured capacitor is a sign.
@stevegingras1625
@stevegingras1625 2 жыл бұрын
Today, the same unit gave me a dsd ou d5d code. The display light up and shows the water temp for 5 seconds than I get this code and nothing works. I can't find anything related to this error code anywhere. Any ideas ? Thanks
@QuaabQueb
@QuaabQueb 2 жыл бұрын
The error codes and their meanings are listed in the manual if I remember correctly, did you check there? You can google the model number and should be able to find the manual.
@stevegingras1625
@stevegingras1625 2 жыл бұрын
@@QuaabQueb Thank you ! No, it's not in the manual. But I finally found the info. It means "defrost sensor defect". I ordered this part and I am going to replace it. We will see ...
@QuaabQueb
@QuaabQueb 2 жыл бұрын
@@stevegingras1625 interesting where did you find the code meaning?
@stevegingras1625
@stevegingras1625 2 жыл бұрын
@@QuaabQueb I search so hard that I can't find back from where. It was in a forum I think. I already got the part yesterday. Will try to install shortly. I will tell you if it solved the issue
@romant1703
@romant1703 3 жыл бұрын
I have an issue. I have an HP error which means waterflow is low. The system cycles off within a few second of cycling on. The flow is fine, The pressure switch is fine but I ran out of things to look for. I got taken last year on a repair and would really like to do what I can prior to calling a tech. I've been looking for a water flow sensor in the unit but can not find it. It is the same system as the one in this video. It is a salt water pool. Any recommendations would be appreciated. Thanks
@QuaabQueb
@QuaabQueb 3 жыл бұрын
Could be a band switch, or an issue with the refrigerant charge. Flow issues I have only seen with variable speed pumps when they are set to run at low RPM.
@romant1703
@romant1703 3 жыл бұрын
@@QuaabQueb You mean the water pressure switch? I checked it and even changed it out and it still does it. Is there a flow switch anywhere in that unit? I know there's one in the piping for the salt water.
@mosesvani5409
@mosesvani5409 Жыл бұрын
U have a restriction in the txv
@mariorodriguez653
@mariorodriguez653 3 жыл бұрын
I have a Hayward HP50HA and it’s tripping my breaker open when in Auto mode (not during Heat/Cold). Have an idea of what it could be?
@QuaabQueb
@QuaabQueb 3 жыл бұрын
There is a short somewhere
@billneurohr2904
@billneurohr2904 3 жыл бұрын
@@QuaabQueb me too. 20amp breaker blows after a few min run time. Did you find cause?
@stephenremillard9462
@stephenremillard9462 2 жыл бұрын
@@QuaabQueb What should be the resistance between each combinations (common, run, start) of a good compressor? I am getting about 3 ohms for all, is it normal. Mine too tripps the breaker :-(
@alexandteresalandestoy234
@alexandteresalandestoy234 2 жыл бұрын
Great video! Thought the effing bird was outside my window for a second. Is the flow switch tube supposed to have water flowing through it ? I see air bubbles and a bit of water in mine and am wondering if Its air locked and simply needs the air bled out of tube Thanks again for the great video
@QuaabQueb
@QuaabQueb 2 жыл бұрын
Flowing, no I don't believe so. If there is pressure in the system it should activate the switch
@alexandteresalandestoy234
@alexandteresalandestoy234 2 жыл бұрын
@@QuaabQueb thank you. I’m going to pull the tube off and drain it. Thank you!
@geolopez4375
@geolopez4375 3 жыл бұрын
How to trouble shoot high pressure reading on a summit unit?
@Bottlejack1
@Bottlejack1 3 жыл бұрын
I have a new just installed raypack. Never run. Trips on high pressure. I checked the water flow. Well above 40gpm. Coil temp drops on start up gets to about 35f. Then compressor shuts down. Ambient temp is 53-55. Water temp 49f. Kinda head scratching my head. I have no bypasses. Possible to much refrigerant from factory? Trips in less the 2min
@QuaabQueb
@QuaabQueb 3 жыл бұрын
Yes that is possible. Geographic elevation is also a factor.
@Bottlejack1
@Bottlejack1 3 жыл бұрын
@@QuaabQueb 597ft. About the same as Detroit. Any other possibilities?
@QuaabQueb
@QuaabQueb 3 жыл бұрын
@@Bottlejack1 I'm not an hvac technician so my experience is limited with with refrigeration. If the unit is brand new something is likely not hooked up right. Try and find the manual for your particular model of unit. All of the operating specifications will be listed and you can begin to troubleshoot from there.
@Bottlejack1
@Bottlejack1 3 жыл бұрын
@@QuaabQueb thanks. I dig into it a bit more.
@QuaabQueb
@QuaabQueb 3 жыл бұрын
@@Bottlejack1 if you do end up calling an hvac guy to check it out make certain they are well versed with pool heaters.
@4hernan
@4hernan 3 жыл бұрын
Any idea how to fix an LP3 error
@moebee3882
@moebee3882 2 жыл бұрын
trying hard not to smash this thing but anyways. New capacitor, new contactor ..not starting up. Shows the pool light and current temp of water but...le sigh nothing happening. The ole' push on the contactor with a screwdriver turns it on though...maybe I'll just keep the position. I'll try the water pressure switch trick tomorrow. What is that black part called that I'll be hitting up the electronic store for please and thank you.
@QuaabQueb
@QuaabQueb 2 жыл бұрын
Try and jump the water pressure switch to see if that is the problem, if not maybe the contactor is not getting power
@moebee3882
@moebee3882 2 жыл бұрын
@@QuaabQueb tried that today too..nada.
@QuaabQueb
@QuaabQueb 2 жыл бұрын
@@moebee3882 check high and low pressure switches?
@moebee3882
@moebee3882 2 жыл бұрын
@@QuaabQueb if I'm doing this right, the LP has continuity but the HP shows a big fat OL.
@QuaabQueb
@QuaabQueb 2 жыл бұрын
@@moebee3882 I believe it should also show continuity
@TrishZenCorner
@TrishZenCorner 2 жыл бұрын
How do you address a code of " FS" ? For this model?
@chizzlemo3094
@chizzlemo3094 4 жыл бұрын
sniffer: $23.... replace the system $2,600, replace the whole unit $5,000. Funny how all repair guys are reluctant to repair it. Do it yourself.
@AdeleGammiero
@AdeleGammiero Жыл бұрын
My pump shows F5 what do i do
@rosarioachi4816
@rosarioachi4816 Жыл бұрын
Quanto gas R410 prende una macchina come questa?
@Freedomyota
@Freedomyota 3 жыл бұрын
I need the fan motor, blade and the top panel from this unit - wanna sell it?
@QuaabQueb
@QuaabQueb 3 жыл бұрын
I had scraped the unit. Parts are pretty standard. Check ebay.
@Freedomyota
@Freedomyota 3 жыл бұрын
@@QuaabQueb thanks for the reply - already did - the top panel is on global back order. Have had one on order for the last 3 months. Good video though!
@chrismason193
@chrismason193 3 жыл бұрын
How to I replace cracked pvc on the back side?
@QuaabQueb
@QuaabQueb 3 жыл бұрын
The inlet connector or the coil ?
@andrewmac8097
@andrewmac8097 2 жыл бұрын
@@QuaabQueb inlet connector y pipe one cracked hard to get access to
@andrewmac8097
@andrewmac8097 2 жыл бұрын
How to get access to the back portion does the bottom disconnect
@2MUCHPWR
@2MUCHPWR 2 жыл бұрын
@@QuaabQueb same question. the pvc pipe is leaking. the side opposite from where the electrical box is... the white PVC on the bottom horizontal to ground. its got a split and i don't know how to get access over there.
@QuaabQueb
@QuaabQueb 2 жыл бұрын
@@2MUCHPWR sounds like freeze damage.
@tonyblanco4631
@tonyblanco4631 9 ай бұрын
Mine shows LP but that means
@JasonJohnson-ke2pr
@JasonJohnson-ke2pr 3 жыл бұрын
Haha...control box with all the " fuckery "
@jaredmallett6091
@jaredmallett6091 2 жыл бұрын
I have this same shitbox and after a dozen uses the low pressure switch died. One year old unit. I had an AC company come out and put gauges on it, full charged. Bought another LP switch that lasted 2 days. Had to hotwire it to run, which it did fine for 2-3 uses. Ice built up on the last use. Now, no heat output. I want to punt this pile of shit through the goalposts of life. Nobody services these in my area. I guess I need to buy gauges now.
@QuaabQueb
@QuaabQueb 2 жыл бұрын
They are pretty good units compared to a lot of the crap on the market. It sounds like you may have other issues. I would start by checking the charge once again and make sure it is within manufacturer specs. It may be over charged. If you have a residential HVAC guy who is not familiar with pool heaters specifically he may have fucked it up. If you keep popping LP switches that hints me that the unit may be over charged. Good luck...
@astroboy3791
@astroboy3791 10 ай бұрын
I have LP error code
@QuaabQueb
@QuaabQueb 10 ай бұрын
LP is low pressure I believe. You can look it up in the manual
@joenwc
@joenwc 3 жыл бұрын
Apparently youtube needs a rating system, you made it less than a minute without using the F word. There are still people in this world that are bothered by this, I am one of them. Too bad for me I guess, but I won't watch farther.
@QuaabQueb
@QuaabQueb 3 жыл бұрын
Go find another video then
@nateatonu
@nateatonu 3 жыл бұрын
BOOOOOOOOOOOOOOOOOOOOOOOOOOOOO
@deank2191
@deank2191 3 жыл бұрын
❄️❄️❄️
@TrishZenCorner
@TrishZenCorner 3 жыл бұрын
How do i replace a hayward pool heater fan motor part #303088001 ?
@QuaabQueb
@QuaabQueb 3 жыл бұрын
Top grille comes off. Simply remove the screws around the sides. Trace the wires back in to the cabinet and disconnect them. Take pictures before unplugging anything so you can see how it goes back together.
@TrishZenCorner
@TrishZenCorner 3 жыл бұрын
Thankkkk youuuuuu🙌🙌🙌🙌👍👍👍👍 @@QuaabQueb
@TrishZenCorner
@TrishZenCorner 2 жыл бұрын
@@QuaabQueb I did it you are amazing thank you!!!!! Now time to figure out what the heck is a FS error I'm golden lol 😆 have a great one thank you for the help again !
@QuaabQueb
@QuaabQueb 2 жыл бұрын
@@TrishZenCorner Google the manual and go to the error codes list, all the error codes and their explanations are listed as well as a brief troubleshooting tip
Pentair Ultratemp Pool Heater Maintenance and Repair
26:44
Retro Tech & Electronics
Рет қаралды 2,2 М.
How to fix a heat pump that won't start
8:36
spelunkerd
Рет қаралды 31 М.
Хаги Ваги говорит разными голосами
0:22
Фани Хани
Рет қаралды 2,2 МЛН
БОЙКАЛАР| bayGUYS | 27 шығарылым
28:49
bayGUYS
Рет қаралды 1,1 МЛН
How To Install a Hayward HeatPro Heat Pump
9:14
Inyo Pools
Рет қаралды 131 М.
Heat Pump Pool Heater Raypak Repair Bad Display & Dual Capacitor Replaced
15:12
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 7 М.
Pool Heat Pump Kalos Meeting w/ Bert
21:09
HVAC School
Рет қаралды 4,5 М.
Swimming Pool Heat Pumps - How they Work
2:47
Luxury Pools and Living
Рет қаралды 265 М.
Heat Pump tripping breaker, Repaired!
13:25
Jeff’s HVAC Adventures
Рет қаралды 7 М.
AquaPro 1100e Pool Heater Heat Pump Not Heating - No Error Code - Compressor Not Powering Up
5:14
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 12 М.
Cleaning a Hayward DE6020 Pool Filter
10:10
Fix It Fox, Inc.
Рет қаралды 11 М.
Pool Heat Pump Calibration Explained (Madimack)
14:12
EEVblog2
Рет қаралды 24 М.
ICP Heat Pump tripping breaker
13:52
Anti DIY HVAC
Рет қаралды 15 М.
Step by Step Heat Pump Maintenance & Cleaning Raypak Pool Heater Instructional Video
12:44
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 21 М.
Хаги Ваги говорит разными голосами
0:22
Фани Хани
Рет қаралды 2,2 МЛН