Introduction to Disconnector or Isolator | Video #5

  Рет қаралды 36,252

Gaurav J - TheElectricalGuy

Gaurav J - TheElectricalGuy

Күн бұрын

Пікірлер: 26
@baqarengr4823
@baqarengr4823 3 жыл бұрын
Doing great job about power system thanks alot sir
@SumitKumar-pf9gr
@SumitKumar-pf9gr 3 жыл бұрын
When Isolator operates or Open on On load, it causes high amount of spark which may cause damage to it parts. Absence of Arc quenching medium unable to extinguish/interrupt the arc while operate on load condition. Hence ensure to operate on No load ensuring CB Open. However, Isolator can interrupt of small amount of inductive/capacitive currents to acceptable design limit corresponds to type and voltage class.
@GauravJ
@GauravJ 3 жыл бұрын
Right !!
@balajiprithviraj5145
@balajiprithviraj5145 3 жыл бұрын
Sir 3d animations r good and visuals also, putting hardwork thanku sir
@rohiths5987
@rohiths5987 3 жыл бұрын
Earth switch is not used for line only .Earth switch is installed in the two ISOLATOR between Breaker and toward breaker side of both isolator
@sachinkharat6848
@sachinkharat6848 Жыл бұрын
If you open (turn off) a non-load break rated disconnect under load, it may get sparky, smoky, or worse.
@giyasuddinansary5332
@giyasuddinansary5332 6 ай бұрын
Very good 👍
@GauravJ
@GauravJ 6 ай бұрын
Thank you 👍
@joshualynch5512
@joshualynch5512 Жыл бұрын
I wish you’d put closed caption on this video!
@nigamsingh8301
@nigamsingh8301 7 ай бұрын
Earth switch operation after opening of Dis-connector switch
@youssofasiry7233
@youssofasiry7233 3 жыл бұрын
Arcing will occur and may damage the contacts of discconector.
@seniorcomputer3292
@seniorcomputer3292 3 жыл бұрын
Was the graphic number system reversed? Will look again. Thank you
@AnilKumar.g63
@AnilKumar.g63 Жыл бұрын
Do you in the session of last question answer is The system will get damaged and interrable
@bilalkakar6620
@bilalkakar6620 3 жыл бұрын
You are doing a great job Sir. I am preperaing for job interview. I have a question regarding the primary and secondary winding configuration for power transformer used in Step up Substation and step down Substation? Thanks in advance. I have a rough idea, delta-star in step-up and star-delta in step-down.
@shkomand
@shkomand Жыл бұрын
I think star delta is for step up
@jijovarghese1987
@jijovarghese1987 3 жыл бұрын
If we operates isolators while on load then heavy spark will occur and can cause problem for the operators and other devices due to switching without arc quenching medium.
@rohiths5987
@rohiths5987 3 жыл бұрын
In practical the isolator can withstand it for some number of times .IPS tube of isolator had rating upto 2400 Amps etc And the copper finger of isolator may ger melted in some cases but not always.
@chinnakarlapraveen9966
@chinnakarlapraveen9966 3 жыл бұрын
If isolator is operated under on load , it produces heavy spark. Am I right sir
@GauravJ
@GauravJ 3 жыл бұрын
Yess 👍🏻
@imeprezime1285
@imeprezime1285 3 жыл бұрын
What happens? The "welding action" 😁
@chinnakarlapraveen9966
@chinnakarlapraveen9966 3 жыл бұрын
@@imeprezime1285(we are creating a short circuit) which use a binder that has a lower melting point, welding joins the two workpieces directly together. Understanding this difference is key to understanding welding
@donberg01
@donberg01 2 жыл бұрын
Why designate phases R-Y-B? Is this a IEC reference? In North America it is labeled phase A-B-C?
@prameelaejju3131
@prameelaejju3131 9 ай бұрын
What happen if we open the disconnect when the current is passing in the line
@nandishks5690
@nandishks5690 3 жыл бұрын
🔥🔥
@energisedengineerguru4418
@energisedengineerguru4418 2 жыл бұрын
Heavy spark.
@balajiprithviraj5145
@balajiprithviraj5145 3 жыл бұрын
Sir 3d animations r good and visuals also, putting hardwork thanku sir
Introduction to Circuit Breaker | Video #6
3:03
Gaurav J - TheElectricalGuy
Рет қаралды 30 М.
Substation equipment and their functions | Quick Revision | TheElectricalGuy
19:59
Gaurav J - TheElectricalGuy
Рет қаралды 160 М.
小路飞还不知道他把路飞给擦没有了 #路飞#海贼王
00:32
路飞与唐舞桐
Рет қаралды 81 МЛН
Haunted House 😰😨 LeoNata family #shorts
00:37
LeoNata Family
Рет қаралды 15 МЛН
How Much Tape To Stop A Lamborghini?
00:15
MrBeast
Рет қаралды 199 МЛН
Disrespect or Respect 💔❤️
00:27
Thiago Productions
Рет қаралды 39 МЛН
What is Switchgear & why we need them? Explained | TheElectricalGuy
10:03
Gaurav J - TheElectricalGuy
Рет қаралды 69 М.
How 3 Phase Power works: why 3 phases?
14:41
The Engineering Mindset
Рет қаралды 1,6 МЛН
Current Transformer vs Voltage Transformer : What’s the Difference ? TheElectricalGuy
12:32
Antipumping in Circuit Breaker | Why it is needed? Explained | TheElectricalGuy
19:04
Gaurav J - TheElectricalGuy
Рет қаралды 22 М.
Overcurrent, Overload, Short Circuit, and Ground Fault
6:54
Dave Gordon
Рет қаралды 916 М.
What is a Gas Insulated Switchgear/GIS | TheElectricalGuy
9:23
Gaurav J - TheElectricalGuy
Рет қаралды 75 М.
What is Earth Switch and why we need them | TheElectricalGuy
14:58
Gaurav J - TheElectricalGuy
Рет қаралды 10 М.
小路飞还不知道他把路飞给擦没有了 #路飞#海贼王
00:32
路飞与唐舞桐
Рет қаралды 81 МЛН