You can potentially save someone thousands of dollar. You are an excellent teacher.
@tylerweatherbee9180Ай бұрын
Your explanation of the windings and showing it with the relays was super helpful.
@SimmoR-mr9by22 күн бұрын
Cheers mate...needed to refresh my memory. Good clear explanation unlike some of my bosses!😊
@gregoriocampo14 күн бұрын
Your videos are well explained. Thanks for sharing your knowledge.
@DougGarrett-xb1vhАй бұрын
Great start to basic wiring and troubleshooting. Always double check and trust your test results....Do not keep resetting the breaker once you have seen indications of shorted phases. Keeps from causing more serious damage to your service panel and breaker.
@HVACPioneerControlsАй бұрын
Yes, I definitely agree. There’s a reason why the breaker tripped in the first place.
@DS-fb9teАй бұрын
Learn something new, God bless you sir.
@jrc290527 күн бұрын
Some of the best explanations so far. On your first drawing you show no direct connection between RS, On the second drawing you show a connection between RS. What is the actual path the resistance takes in the compressor?
@HVACPioneerControls27 күн бұрын
The first drawing. The second drawing just shows what you would physically see on the compressor pins
@jrc290526 күн бұрын
I believe I am somewhat dyslexic so I have to be able to trace out a circuit before I can understand it. So, the power comes in at terminal C. R-C has the lowest resistance so what prevents it from going that way? Thanks.
@i-d-m-system.569720 күн бұрын
Great information, 🙏
@elleondejuda4681Ай бұрын
Very nice 👍 Do you have a video on how to properly check amps on compressor and what is it for ? Can you also explain how to check a Fan motor ? Thanks
@HVACPioneerControlsАй бұрын
I can work on that in the future.
@publicmail228 күн бұрын
What causes smoke detector to beep every min?
@HVACPioneerControls27 күн бұрын
My meter was going off because I left it on standby lol
@mattlubbers938321 күн бұрын
What if the system has water vapor and acids form and the compressor still is running fine ? can you tell if the compressor is going bad by these checks or do an acid test and evac the system then dehydrate the system to 500 microns and put in recycled refrigerant or virgin refrigerant ? or if there is a odd smell coming off the compressor?
@alfredhines505Ай бұрын
It is a single phase not a one phase.
@EliasMartinez-d2gАй бұрын
Yes but sometimes the unit specs display " Phase: one"
@30rdmagaАй бұрын
Explain the difference
@stepper_3417Ай бұрын
Already hating
@Mr.Goodguy83525 күн бұрын
😂good for you
@klarnorbert23 күн бұрын
Horseshoe LMAO.The ohm (symbol: Ω, the uppercase Greek letter omega) is the unit of electrical resistance in the International System of Units (SI).
@harryschrysan3183Ай бұрын
Testing continuity on the copper is always the best choice since the paint of the compressor does not make good contact if any.