J & E Hall Cellar Cooling System Install

  Рет қаралды 930

heavydiesel

heavydiesel

Күн бұрын

Пікірлер: 15
@Cosmo95_
@Cosmo95_ 2 жыл бұрын
Always a good idea to bridge the contactor in the evap on these J&E Hall units as they can burn out after a few years. Great vid as always HD 👍
@heavydiesel
@heavydiesel 2 жыл бұрын
Thats a good idea, Its funny I looked at the contactor and thought it was a waste not to use all three contacts but didn't actually do anything about it!
@scottk0623
@scottk0623 2 жыл бұрын
Nice job. That line set has quite the turns in it, looks good. I have bought those rubber mounts to run line set on a roof they aren’t cheap.
@heavydiesel
@heavydiesel 2 жыл бұрын
Yeah the rubber mounts are really expensive for something thats made of recycled tyres!
@sjefoekel6058
@sjefoekel6058 2 жыл бұрын
Those walls are completly rotted out due to moisture ingress, this is crazy. Nice job tho👍
@heavydiesel
@heavydiesel 2 жыл бұрын
Its very damp as its below ground level, plus there is no floor drain.
@FrontSideBus
@FrontSideBus 2 жыл бұрын
Looks good! Vac pump sounds a little unhappy! Do you weigh in the coils and copper from the scrapped units?
@heavydiesel
@heavydiesel 2 жыл бұрын
Yeah thats Daves 'Dosivac' vac pump, must be getting on for 18 years old and still working! I usually take the coils away, some times I weigh them it but more often give them to passing scrap collectors as not really work the hassle unless you've got a lot of them.
@baduk16
@baduk16 2 жыл бұрын
nice job
@heavydiesel
@heavydiesel 2 жыл бұрын
Thanks!
@gerardomireles122
@gerardomireles122 2 жыл бұрын
Thanks again heavydiesel cool I see bottles of to drinking Are you took it to 🍻🍷 Thanks again
@paulsilver1625
@paulsilver1625 2 жыл бұрын
J and E Hall. Best change the dixel controller now or you’ll be changing it in a few months
@robertscott7102
@robertscott7102 2 жыл бұрын
Just installed the smaller model, what controller would you recommend?
@Cosmo95_
@Cosmo95_ 2 жыл бұрын
@@robertscott7102 Dixel controllers aren’t that bad, but can fail sometimes, most I see last for years. If you really wanted to upgrade it, it would be best to keep the digital display and fit a mechanical thermostat like a ‘ranco’ for the control circuit. A common fault you might see with the J&E Hall systems is the contactor in the indoor unit that can burn out, this can be solved by bridging the contactor over it’s 3 channels, as from factory they run it just through just one channel. Also it can be good idea to add PTFE tape to the alan key ports / schrader core threads on the outdoor unit to prevent any refrigerant leaks in the future. Main thing is to keep the outdoor unit condenser coils clean and it will look after itself.
@robertscott7102
@robertscott7102 2 жыл бұрын
@@Cosmo95_ Thanks, that's really good to know especially about the contactor fix
DIY Vapor Compression Refrigeration System
28:06
Hyperspace Pirate
Рет қаралды 1,2 МЛН
CELLAR COOLER
13:56
HarryBrew69
Рет қаралды 2,9 М.
СКОЛЬКО ПАЛЬЦЕВ ТУТ?
00:16
Masomka
Рет қаралды 3,1 МЛН
Who's spending her birthday with Harley Quinn on halloween?#Harley Quinn #joker
01:00
Harley Quinn with the Joker
Рет қаралды 27 МЛН
Data Center HVAC Systems
20:14
MEP Academy
Рет қаралды 135 М.
Walk in Cooler Install
13:19
heavydiesel
Рет қаралды 6 М.
Wine Cellar Cooling System - How It Works
2:44
USCellarSystems
Рет қаралды 12 М.
How does the air conditioner work?
7:26
Mscope
Рет қаралды 3 МЛН
Portable Air Conditioners - Why you shouldn't like them
16:39
Technology Connections
Рет қаралды 8 МЛН
DIY Mini Split Install - All the Things Nobody Shows You
33:25
LRN2DIY
Рет қаралды 2,2 МЛН
Warranty Compressor Failure
11:27
heavydiesel
Рет қаралды 657
Anti-British hater destroyed in colonialism debate.
8:14
The Alternative View
Рет қаралды 2,1 МЛН
СКОЛЬКО ПАЛЬЦЕВ ТУТ?
00:16
Masomka
Рет қаралды 3,1 МЛН