God bless po kuya... Salamat sa mga turo mo.. sana dika po magsawa mag turo ng marami kapang maturoan. Gusto ko yong mga vedio mo panuorin kasi naka detalye lahat walang cut cut. Di kagaya ng ibang vloggers pinuputol pera lang habol.. ayaw e turo lahat step by step.....
@JMTUTORIAL5 ай бұрын
salamat po bossing
@kakosa18665 ай бұрын
Sir JM salamat sa pag tuturo mo Sana wag k magsawa ng gumawa ng tutorial at Sana wag k magsawa Na ituro ng step by step ung IBA kc hindi step by step sau lng aq natuto dahil malinaw ang pg turo mo LAlo pg gamit Jan sa manifold Guage. Salamat ng marami boss
@norielflores34025 ай бұрын
Pareho kau ni master lhon .. verry good ...❤❤
@NelsonPalos-ev2iz3 ай бұрын
Maraming salamat po 🙏 guro
@celsoalcantara89105 ай бұрын
Ok lods slmat sa pagtuturo mo,god bless
@danilosoltura28403 ай бұрын
Thanks for sharing
@MarlonMateo-zy7li4 ай бұрын
Good job
@reyrey5202 ай бұрын
Galing
@felixmediana68675 ай бұрын
Saan Ang pwesto nyo sir jm,,,
@jlson125 ай бұрын
boss my board ba kayo ng ctd250mni condura
@ArtSagucio5 ай бұрын
Brod ganyan sin problema chest freezer ko pwedi mo b ayusin bos.loc.mexico pampanga
@magalingmagdebate5 ай бұрын
Magkano ang singilan pag ganyan idol
@margieroseagustines30255 ай бұрын
Freezer na mamatay pag 20 minutes. .tapos d na babalik. ?ei unplug Muna Bago andar ulit
@Ibanez251455 ай бұрын
Gaya ..moves..
@danilovigan4233 ай бұрын
I watch your YT tutorial about R600 Refrigerant I’m Certified HVAC Technician with Lic# ending 38D0 EPA 608 Universal at D2 po ako sa USA as HVAC Tech and working as Generalist Service technician on all brands and kinds of Appliances. With due respect po the best practice po to remove system moisture by using Dry nitrogen that is According to EPA by using nitro regulator you can apply up to not more than 120 PSIG both low and high side that will be Flushing system and use also Nitrogen as leak system method Up to not more than 120 psig liquid detecting agent or leak detector. According to EPA and by the Book you can’t charge more than specific amount of grams since R600 is a low boiling point refrigerant so you can’t charge more the the specific amount @ 125 psi at 90F and low side operating pressure of -5 to -18 Vacuum in the long run it may choke your Compressor and back frost your Suction line which may result breaking your compressor mechanical and flooding your system, best tool weighing scale for R600 refrigerant to be charge after system vacuuming and always Safety First when Removing R600 make sure your area is a well ventilated space so it will not accumulate R600 on your work place avoiding Fire Hazard and always have Fire Extinguisher with you in case of unexpected Fire occur as per EPA regulations as always Safety Comes First thanks FYI lang po🙏🏼