@rodeliorivera4947
@rodeliorivera4947 2 жыл бұрын
I am sorry sir, but I have ti disagree with you in some procedures, statements and explanations that you have mentioned in your video. I will save the other matters for the meantime, considering that your work in the video is pretty well appreciated by the viewers including me. First, the refrigerant condition in the evaporator (freezer) is at low-pressure, low-temperaure state. Not low-pressure, high temperature. Second, you did not mention if the compressor should be working or not if you are to re-charging a refrigerant in its vapor-state or liquid state. Another thing is, where do you tap the hose when you will do the liquid charging? This is supposedly a very imprtant part of your video. Third, vacuum pressures are not mentioned as negative if you are using inches of mercury units. They are plainly measured from o to 29.92 or practically 30.0 in. Hg. If you use inch Hg unit in vacuum pressures, it is understood to be partially vacuum . Negative numbers in partial vacuum are used as layman's terms if they are referring to SI units. Oftentimes they use 0.10 to 0.99 bar, indicating that it is below 1-bar absolute pressure. Fourth and final hopefully, in all aspects of analyzing the condition of a refrigeration system, it is always the pressure that we depend upon. Not the temperature, and not the amperage. Temperature and amperage readings only come handy as secondary to the working pressure. What do I mean by these? You should be using apressure-temperature table or chart to better understand if the system is operating normally or not. I would like to mention also as to how do you remove the charging hoses - the low side and the high side; is it while the motor is operating still or when it is turned off and wait for some more minutes? If you ought to teach other technicians the step-by-step procedures of charging a refrigerant system, I suggest that you please include them in your next video or if you will edit your video. I a m a person who appreciate people like you who put some efforts, time, and money to educate other people in technical areas like refrigeration. That is why I am giving comments such as these. Deep in my heart, my comments are well meant. Thank you.
@KALECKYTV
@KALECKYTV 2 жыл бұрын
wow thank you for sharing..
@alfeodemate8122
@alfeodemate8122 2 жыл бұрын
Hala! nayari na sa panelist.
@arielmera342
@arielmera342 Жыл бұрын
pls do your share educate us by making a tutorial video.. tnx..
@nickboniel1756
@nickboniel1756 5 ай бұрын
Tama po kayo sir.. baliktad po sa kanya..paano naging low temperature ang high pressure.. at high pressure naging low temperature.. .. dapat high pressure high temperature at low pressure low temperature.
@jrpalacio2448
@jrpalacio2448 3 жыл бұрын
Napaka galing mag explain sobrang nakaka tulong .. magaling mag turo kumbaga pulido at madaling maintindihan sa mga nakaka relate na nag aaral plang ng technician.. good job idol ..
@reynaldobatiduan5514
@reynaldobatiduan5514 Жыл бұрын
ayos sir marami akong natutunan sa iyong vlog about refrigeration.. thanks
@Ibanez25145
@Ibanez25145 Жыл бұрын
Sunog .halatng .bgauhan pa.....sa sususnod ..mg iingat kna sir...experince is the best techer.....
@arielmera342
@arielmera342 Жыл бұрын
salamat po dami ko natutunan.. hirap na magtiwala sa ibang aircon tech. 2x na din ako nadenggoy 8700 yung una. 2700 yung pangalawa. ang resulta hilaw parin ang aircon ng kotse.. buti oo may ganito tuturial mag diy na lang ako.. bili nalang din ako gamit. tnx po at mabuhay kayo..
@musikoakotv9225
@musikoakotv9225 3 жыл бұрын
ang lupit nyo tlga mag paliwanag..first time ko lng manood sa tutorial nyo nawili nako manood..dami ko nattunan sa inyo..sinubscribe ko kaagad at alam ko maraming mattunan sa inyo..
@zovekmalonzo1934
@zovekmalonzo1934 2 жыл бұрын
lods maraming maraming salamat.. sa tutorial.. Godbless.. hayahan lang po mas marunong pa sila.. pero i know hindi po yun ang sukatan.. ang sukatan po jan ay. kung sino mas mabebless.. kung sino po pinepersecute.. ay siya lalo ang itataas ni lord.. kaya kampay lods.. More more blessing pa po darating sa inyo.. marami salamat po.. ulit hanggang sa muli..
@salvadorcastanosjr2050
@salvadorcastanosjr2050 3 жыл бұрын
Sir napakagaling at mahusay Kang magturo ,,👍👍 ,nag aral din ako sa non formal educ, maayos Naman magturo Ang instructor namin ,,pero iba ka sir .mabilis matututo Ang studyante mo 👍👍
@joseelmarjuanico5181
@joseelmarjuanico5181 3 жыл бұрын
Salamat po sr sa kaalaman na eshare nyo . Ingat kayo lagi at pagpalain kayo ng boong maykapal upang marami pa ksyong matulungan
@AimGobalWorldBibleSchool
@AimGobalWorldBibleSchool 9 ай бұрын
ayos! quality and safey!......attention to details...Good Job..Thank you...
@lhorhenzchasthillo565
@lhorhenzchasthillo565 3 жыл бұрын
Sir...lahat ng content ng videos npka informative at napakalinaw ng paliwanag...thank you for sharing
@benjaminmelgar9327
@benjaminmelgar9327 2 жыл бұрын
Thank sir, malinaw complete with diagram..kay sa inaral ko noon sa school. Sana magpatuloy pa tutorial mo, salamat ulit 😀 :)
@israelbunda5158
@israelbunda5158 Жыл бұрын
One of the best.Good video tutorial from start to finish
@leonsosa4377
@leonsosa4377 Жыл бұрын
Ayos sir nadagdagan na naman ang aking kaalaman thank you sir napakaliwanag ang iyong turo
@prettycute5582
@prettycute5582 3 жыл бұрын
Kudos migo.. nice n fully explained...
@jackpega5740
@jackpega5740 2 жыл бұрын
Sir ung ref. Po. Samsung na inventer pinagawa q po dhil di na magyelo tpos ung gumawa ngkarga lng sya ng freon tpos ayaw na po umandar ng motor ng ref q.
@artistahinsam3766
@artistahinsam3766 3 жыл бұрын
Kung Ganito Teacher ko Malamang malilipat ako sa Row 1...lagi ako row 4 kasi😂😂✌️✌️ joob job Sir Lecky👏👍👌😁🇵🇭
@joelraquiza2795
@joelraquiza2795 2 жыл бұрын
wow thank you sir ganda ng paga explain sa tutorial✌️
@miguelbalmores9717
@miguelbalmores9717 Жыл бұрын
ang ganda ng paliwanag mo sir . naiintindihan ko na di tulad sa iba wala ko maintindihan.
@jhunecollado7519
@jhunecollado7519 3 жыл бұрын
ito ang tutorial...napaka linaw...tnx sir sa dagdag kaalaman
@laagangtechniciam
@laagangtechniciam 3 жыл бұрын
RAC tech peru nood pa din..thumbs up idol..god bless
@gwapitomojica384
@gwapitomojica384 3 жыл бұрын
Subscribed nako sir maganda ang topic mo eh sana meron pang interesting topic next
@edmondmangalino
@edmondmangalino 3 жыл бұрын
ang linaw ng explanations.thank u engineer!
@teddycontalba8595
@teddycontalba8595 3 жыл бұрын
Nice video well explained goodjob..
@jerwinlopez6895
@jerwinlopez6895 9 ай бұрын
bro kung wala ka leather pwde mo gamitin yun hardiflex gawa sa asbestos yun hindi iinit at masusunog.
@michikoandfriends835
@michikoandfriends835 Жыл бұрын
ito yong dapat panoorin , ito yong saktong process sa reprocess medyo na kulangan lng ako sa vacumm part yung e open yung high side 1st to determine if barado ba ang system o hindi then yung initial charging sa highside na pwede liquid hehe pero goods parin kay sa ibang tut more power
@toolboxbymark8692
@toolboxbymark8692 3 жыл бұрын
Ayus sir informative po,pa shout out naman po,God bless
@hvanmagno9633
@hvanmagno9633 3 жыл бұрын
Magaling ka idol salamat sa mga idea at info mu..
@jacquesrobert159
@jacquesrobert159 3 жыл бұрын
Salamat. Can we charge it with 134a instead of R600a?
@kevinhanerjr7134
@kevinhanerjr7134 3 жыл бұрын
Sempre idol lagi ako nag aantay sa new vidio mo pag walang magawa eh un mga dati mo vidio ang pinapanood ko sau ko nlng kasi nakikita ung panagarap ko mag seaman ee
@lilymoreno394
@lilymoreno394 3 жыл бұрын
thanks boss sa tutorial maynatutunan kami gdbless
@oseng0010
@oseng0010 3 жыл бұрын
Bagong Refrigerant na ata si r600a... kakabili ko lang ng personal 3.5k cubic na ref. R600 din siya at di siya inverter... salamat dito pinaplano ko din sa ref ko kapag nawalan ng refrigerant ako na magkarga.. same procedure lang din pala sa mga a/c sa work ko sa hotel..
@chemaerezeachesingson3623
@chemaerezeachesingson3623 Жыл бұрын
nice tutorial galing saludo po ako sa inyo
@markvillanueva2938
@markvillanueva2938 3 жыл бұрын
Sir, meron kbang videos about sa refrigeration plant onboard ship? Any troubleshooting or even charging ng refrigerant sa refrigeration sa barko? Thanks Boss 😊
@reyjongeroy1409
@reyjongeroy1409 3 жыл бұрын
Salamat sa kaalaman sir nice sa turo mo
@salvadorcastanosjr2050
@salvadorcastanosjr2050 3 жыл бұрын
Watching here in butuan city sir ,,
@matlesterdivinagracia6528
@matlesterdivinagracia6528 3 жыл бұрын
nice explaination Sir👍
@poncianoespiritu6527
@poncianoespiritu6527 3 жыл бұрын
You explained very well.
@tiktokmashup4840
@tiktokmashup4840 3 жыл бұрын
Nice malinaw sa pag turo sir tnx
@Lecmar1991
@Lecmar1991 7 ай бұрын
Sir ask lang.. ngayun kulang alam to.. sir sabi daw nila pag nag karga ng refrigerant sa suction kailangan daw i taub yung tangki para makapasok c liguid...taz ngayun sa video mo bawal pala ang liquid sa suction dapat pala gas lang papasok? Puede parin ba itaub ang tanki mag charge nag refrigerant? Sana masagut commet mo sir.. salamat
@renatobraganza3180
@renatobraganza3180 2 жыл бұрын
Ibig bang sabihin master kahit anong refregerant ang ikarga, sa ref man o sa aircon, laging gas sa low side o sucktion valve?
@joeycrisostomo5910
@joeycrisostomo5910 2 жыл бұрын
sir yun high side po ba dapat open yun valve during charging process kc yun low side mo lng ino open dimo ipina liwanag slmt.
@mr.jimboy6563
@mr.jimboy6563 5 ай бұрын
Sir, yung charge ba sa compressor ay always low pressure side, gas state refrigerant???
@AldrinAlbano
@AldrinAlbano 2 жыл бұрын
Ayos!! Salamat Sir!! Aprobado na 👍🏼👍🏼🙂
@quintozj10
@quintozj10 9 ай бұрын
Mga magkanu po ang tancha niyo na price kapag parefill ng refrigirant na r600a and filter replacement?slmat sa sagot sir...
@kapadjakbibichannel5237
@kapadjakbibichannel5237 3 жыл бұрын
Nice video master! Pavisit naman dn at papajak narin kasisimula palang 😊
@bulakboleros9300
@bulakboleros9300 3 жыл бұрын
nice sir.galing..godbless u!
@froylightsandsounds6990
@froylightsandsounds6990 3 жыл бұрын
Sir pag bagong compressor ba kilangan lagyan Ng freon? O di na .at pg ngkkrga ka dapat b nakaswitch ref? Tnks kung mssgot mo sir
@litomendiola3165
@litomendiola3165 11 ай бұрын
Galing mo ma-2-2-to ako syo mag-ayos ng ref at aircon
@jobertpage-et1349
@jobertpage-et1349 3 жыл бұрын
Number twenty-eight...👏🕊👍 Two-one-seven viewed po kalecky...😉 Nice demo, informazyuniz tipz... 04:43 - anung refrigerant use nyu po jan sir? Phaze-out na po now c R-12 sir, hehe... Hindi nyu po yata na kabitan ng clamp-ammeter while nag karga po keu huh...😉💥✌
@kuyawintvtech8931
@kuyawintvtech8931 3 жыл бұрын
Watching here boss thanks for sharing the video.
@antonioumali4640
@antonioumali4640 Жыл бұрын
Ok sir malinaw ang turo mo
@obenskisvlog2115
@obenskisvlog2115 3 жыл бұрын
Nice, thks very informative. Nag subs na rin ko sayo. Ang Kelvinator namin ay hindi rin lumalamig pinalitan ko na ng starter relay and overload, hindi parin mag start ang compressor, and suspetsa ko ay kulang ng refrigerant. May napanood ako at doon ako mag add ng refrigerant sa suction line gamit ang piercing valve with adapter. Tama ba ito Tol? Thks
@obenskisvlog2115
@obenskisvlog2115 3 жыл бұрын
any suggestion Tol? salamat
@obenskisvlog2115
@obenskisvlog2115 3 жыл бұрын
Buo naman ang compressor at may contuinity.
@00ffccadobongsili
@00ffccadobongsili 3 жыл бұрын
Kalecky 2:30 correction low temp kapa din remember compressor SH. yun lang overall 💯 💪
@rasssike5941
@rasssike5941 3 жыл бұрын
ANONG MALI SA 2:30 WLA NMAN KSE HIGH TEMP PDIN KSI HINDI PA NAG BOBOIL ANG REFRIGERANT BANDANG GITNA NA MAG LOW TEMP ANG REFRIGERANT. CORRECT ME IF IM WRONG
@00ffccadobongsili
@00ffccadobongsili 3 жыл бұрын
@@rasssike5941 panuodin mo ulit kung paano nya I explain yung part ng evaporator, Never ka magkaka high temperature sa evaporator nasa part ka ng saturation or latent heat baka Superheated refrigerant pa pwd. Pwd mo din i search ito Superheat Subcooling Latent Heat Sensible Heat Saturation refrigeration cycle na yan =)
@avelinobelga6019
@avelinobelga6019 3 жыл бұрын
Ok yan sir,meron ako natutunan sau .
@joelcaballero664
@joelcaballero664 Жыл бұрын
sir ang pagkakaintindi ko sa refrigeration cycle pag nasa(condenser) discharge line o high side ang refrigerant,automatic magiging liquid form na sya then papasok ng capillary tube para macontrol ang refrigerant na maging gas form pag pasok nya ng (evaporator)low side at pag may nakalusot na liquid form refrigerant dun naman sya maiimbak sa accumulator para maging gas pag pasok nya sa suction ng compressor para hindi masira at mahirapan ang compressor na icompress ang refrigerant then another cycle na naman same process.thank you.
@cjl2396
@cjl2396 3 жыл бұрын
Boss, Always directly proportional ang temperature and pressure. If high pressure high temperature sya.
@johnericksiosana1843
@johnericksiosana1843 3 жыл бұрын
Yes tama, unless gagamit ka ng any device to change either pressure or temperature while maintaining the temperature or pressure.
@johnericksiosana1843
@johnericksiosana1843 3 жыл бұрын
Isang example jan is ung expansion valve, nirereduce nya ang pressure while maintaining the temperature.
@musikoakotv9225
@musikoakotv9225 3 жыл бұрын
Pa shout out po sa next tutorial nyo..
@naturetvph331
@naturetvph331 2 жыл бұрын
Sir possible ba na may leak kapag vacuume pressurized, pero kapag high pressurized wala naman leak? Anu kea nangyayari sa car aircon system ng advi ko? Ganyan kasi nangyayari, nung nag vaccume na ko at observe ko for 5 minutes pa lang may bawas na vaccume pressure. Pero kapag naman kinargahan ko compressed air up to 50 psi sa low side wala naman leak kahit 15mins. Baka may malupit kang idea sir na lumusot sa kin hehe
@edithovergara5257
@edithovergara5257 6 ай бұрын
Sir paano po kong ang ginamit na filter drier ay flare nut? paano magagamit gauge sa high side? Salamat po sa response.
@nhelcadz6599
@nhelcadz6599 3 жыл бұрын
Ayos yan sir.. ano nga pla brand ng vacuim pump gamit mo?
@alexandriaquinnescape1035
@alexandriaquinnescape1035 13 күн бұрын
Ano po ba dapat ang need ikarga liquid or gas?
@edwinvillaceran245
@edwinvillaceran245 3 жыл бұрын
Sir tanong ko lang anong gamit mong pang hinang ng copper pipe
@marlonjamesbayaras8981
@marlonjamesbayaras8981 7 ай бұрын
Sobrang volatile daw ng r600A o mabilis lumiyab, parang butane din
@alexsup5237
@alexsup5237 2 жыл бұрын
Sir ilang psi sa inverter ref lg 1.3amp ang current at hindi daw puede gumamit ng141b pag flushing sa evaporator
@royfrancisco5584
@royfrancisco5584 3 жыл бұрын
Nice bos.
@jonathanclores4892
@jonathanclores4892 3 жыл бұрын
Salamat ulit sir. God Bless u more!
@John-yd5ve
@John-yd5ve 2 жыл бұрын
Salamat bossing. 👍🏻👍🏻
@jojotech4615
@jojotech4615 3 жыл бұрын
Nice tutorial sir
@clodimirsantos2279
@clodimirsantos2279 3 жыл бұрын
Watching sir KALECKY.
@abcdefghijklmnopqrstuvwxyz6686
@abcdefghijklmnopqrstuvwxyz6686 3 жыл бұрын
sir pwedi kayu mag topic about chiller a.c or domestic reef
@jilllumandos4808
@jilllumandos4808 Жыл бұрын
Good s detailed
@ernestoongat4596
@ernestoongat4596 3 жыл бұрын
Ang ganda ng tutorial mo dto sir ah, sakto dto sa ref namin na nagleak samsung din inverter, my tanong lng ako sir kung tanggalin ko yung filter drier hinangin ko siya, diba sasabog yung compresor sir kc R600a nga yung freon niya pls sir sana mabasa muto at masagot tanong ko salamat ng marami, marami ako natutunan
@Solnet29
@Solnet29 3 жыл бұрын
very good journey....
@monraxtv5539
@monraxtv5539 Жыл бұрын
Maganda pagkakagawa mo sir. Pero hindi ako sang ayon sa pagka explain mo sa refrigerant cycle dapat kapag pumasok sa low side ang state ng refrigerant ay magiging low presure low, low temp. Vapor gas hindi low pressure high temp. Gas.
@andresvargas8306
@andresvargas8306 3 жыл бұрын
Sir pagnag karga ba ng refrigerant bale ang sinusunod ay yong rated current s Specs ng compressor n nakasulat Thank you sir
@richardsonrazo1575
@richardsonrazo1575 3 жыл бұрын
Kabaro ang gamit mong pressure gauge pagkarga sa refregerator ay parehas ba sa mga ginagamit sa barko?
@ranjaygernale3243
@ranjaygernale3243 3 жыл бұрын
SALAMAT. TANONG KO PO.LUMAMIG PO SIYA KASO YUNG AUTOMATION OFF SYSTEM DDI NAGOOFF.. SIRA BA YUNG SENSOR SA COLD ?
@ranniebase1634
@ranniebase1634 3 жыл бұрын
Mgandang hapon ayos idol..
@JohnTv03
@JohnTv03 3 жыл бұрын
Kalecky may part 5 paba? Hehe good job 👏
@dantetadoy8982
@dantetadoy8982 3 жыл бұрын
Boss pano po malalaman kong need n kargahan ng refrigerant ang isang compressor? 3HP ang rated ng condenser/compresaor s pag gawa ng ICE BLOCK., salamat Boss...
@royalebusiness225
@royalebusiness225 3 жыл бұрын
pag tinanggal po b ung mga hose after mag charge di po b sisingaw ang refrigerant?
@markcarino489
@markcarino489 3 жыл бұрын
salamat sir sa mga videos mo, new sub here..
@allaroundchannel9947
@allaroundchannel9947 3 жыл бұрын
Dami matutunan dito
@Perazuu
@Perazuu 3 жыл бұрын
Sir pag converter ba gaya din ng ibang design ng old model na ref na yung capillary tube naka ikot sa low side ng system
@felipedapucanta5345
@felipedapucanta5345 3 жыл бұрын
Last segment boss malalaman na kun nagyeyelo?😍😍😍
@marlonsaludo6097
@marlonsaludo6097 3 жыл бұрын
Sir tanong tamang pressure sa manifold guage pag gamit ay r404A?
@gregoryocampo3852
@gregoryocampo3852 3 жыл бұрын
Good day po sir, thanks sa tutorials. 1st time ko po maka encounter ng r600 fridge, nakakuha aq ng idea dito sa inyong video na negative pressure sya. After ko mag hinang sa evaporator, nagflushing, palit filter. Nag initial charge po after ng vacum hanggang itinama ko na po sir sa (-1psi). Ok po sya hanggang almost 2hrs, bigla po nag (-20)?
@vincentacunatv..2776
@vincentacunatv..2776 2 жыл бұрын
Sir, ano po bang magandang manifold?
@sheikhemirsilvestre9796
@sheikhemirsilvestre9796 3 жыл бұрын
kalecky, pwede ba mahingi value ng hitachi refrigerator inverter thermistor?
@manuelramosjr.4193
@manuelramosjr.4193 2 жыл бұрын
Galing mo sir
@UB2KTV
@UB2KTV 3 жыл бұрын
Good info thank you very much
@johnclemente7082
@johnclemente7082 5 ай бұрын
Ayos sir.
@boyetski071
@boyetski071 3 жыл бұрын
Sir tanong lang po bakit yung ref compressor ko na panasonic ay 4 ang line bukod pa yung service valve d66c12gax6 model ng compressor diko ko po ma gets new lang nag aaral
@johnmichaelpatena6056
@johnmichaelpatena6056 3 жыл бұрын
Correction lang po, after po ng capillary tube/expansion valve, ang state po ni refrigerant is low pressure low temperature liquid po. After compressor/discharge linr pa po ulit siya magiging high temp/high pressure vapor.
@ELECTRONICWARFAREMASTER
@ELECTRONICWARFAREMASTER 3 жыл бұрын
What idiom it is . ? It is idiom mix english and Brasil.
@joelcaballero664
@joelcaballero664 Жыл бұрын
baliktad yata sir,pls read books about refrigeration cycle.
@uvl1734
@uvl1734 3 жыл бұрын
Haha ako na una idol.hehe
@KALECKYTV
@KALECKYTV 3 жыл бұрын
Salamat hehe. Apir
@reymondabayon8656
@reymondabayon8656 6 ай бұрын
I want to know kung ilan yung Pressure na Ilalagay during pre charging, and Kung after pre charging ay pagaganahjn naba Ang Unit? Also for Checking lang Po ba ng Pressure yung Sa High side Guage? No need napo ba Mag charge ng liquid? Kung sino po makakasagot napakalaking Thank you po agad,😊
@ahmed73909
@ahmed73909 3 жыл бұрын
Niceo
@gregoryocampo3852
@gregoryocampo3852 3 жыл бұрын
Rest ko po ng 15mins, restart ko sya, same ulit sa -1psi. Nababa po sya pag mainit na sa -20 pero drtso nman andar ng motor nia. Slmat po sa advise!
@seamantv6182
@seamantv6182 3 жыл бұрын
Very nice video kalecky big help sa mga nais matuto keep safe kabaro
@zyrusmandovlogs1345
@zyrusmandovlogs1345 3 жыл бұрын
Nice boss
HOW TO CHARGE REFRIGERANT R32 | REPLACEMENT COMPRESSOR
39:51
JDL ELECTRONICS SERVICE CENTER
Рет қаралды 45 М.
Synyptas 4 | Арамызда бір сатқын бар ! | 4 Bolim
17:24
REAL 3D brush can draw grass Life Hack #shorts #lifehacks
00:42
MrMaximus
Рет қаралды 11 МЛН
버블티로 부자 구별하는법4
00:11
진영민yeongmin
Рет қаралды 22 МЛН
Osman Kalyoncu Sonu Üzücü Saddest Videos Dream Engine 262 #shorts
00:20
Brilliant technique of lead acid battery restoration
11:23
Evidz
Рет қаралды 12 МЛН
How To Charge Gas/Refrigerant In A Refrigerator - R134A Freon
10:21
Forever Tech English
Рет қаралды 848 М.
How to Charge Refrigerant (Gas) in an AC unit?
3:00
Zebra Learnings
Рет қаралды 195 М.
REFRIGERATION MANIFOLD TUTORIAL
12:43
BAHAY IMPROVEMENTS
Рет қаралды 41 М.
How To Charge Refrigerator with R600A Freon/Refrigerant
8:49
Forever Tech English
Рет қаралды 170 М.
HOW TO CHARGE R410 IN SPLIT TYPE AIRCON  // TRICIA 2021
12:59
Tutorials in Ref and Air Con / Joyjob 2020
Рет қаралды 123 М.
Synyptas 4 | Арамызда бір сатқын бар ! | 4 Bolim
17:24