That is how my father tests gas lines back in the day, matches
@kirbypmorris23 күн бұрын
Eastman 3/4 in. FIP X 3/4 in. D FIP 24 in. Stainless Steel Gas Connector. Epoxy Coating provides extra protection from corrosion, chemical stains from common household products, and UV rays and is approved for indoor/outdoor use.
@johnphillipsplumbing714823 күн бұрын
@@kirbypmorris thank you!
@davidrosenberger340020 күн бұрын
John , when using pipe dope on the flex connector threads , make sure you don’t get any on the sealing flanges. I used to get so many gas leak calls from people doing there own flex connectors and pipe doping the whole connector including the flanges . I know you know better but maybe stress that to others to keep the sealing flanges clean . Also , those fittings were so loose , I might have done a 5 min. shadow test on the meter before lighting anything back up ,just to make sure no other leaks inside . Keep on piping brother 😎
@davidrosenberger340020 күн бұрын
Also ,up here in mi , new construction uses flex line for most of the houses here ,from inside to the meter connection
@ResidentialRepairs23 күн бұрын
Wow! I thought that was going to turn into a can of worms but you whipped it into shape fast. Great job John.
@TLboston.323 күн бұрын
No code book in Florida needed I guess
@johnphillipsplumbing714823 күн бұрын
@@TLboston.3 so,I've attached the Florida gas code. Find a specific violation and open up the conversation, otherwisestfu
Its called an appliance connector for a reason you hack, take the extra 5 minutes to hard pipe it. It may not be wrong in the book but it looks like shit
@johnphillipsplumbing714823 күн бұрын
@nhhvac2167 so it's up to code,but it doesn't look pretty? Are you kidding me ,go find somewhere else to play,troll
@wrkhrdplyhrdr22 күн бұрын
Those connectors were designed for stoves and dryers because they need to be moved to access them. I get it's a Saturday but damn man don't post a video for everyone to see if you're gonna do some shit like that. I think you're funny as hell but I'm gonna bust your balls for something like that
@briansheridan631523 күн бұрын
Not even mickey would put a flex on! Wtf
@coreyk299821 күн бұрын
Great content thanks for sharing!! Subscribed
@timothyglasscock164322 күн бұрын
You can use a flex on an outside meter if you wrap the flex line in some kind of weathering tape or wrap . It is supposed to be protected from the elements.
@johnphillipsplumbing714822 күн бұрын
@timothyglasscock1643 I believe the yellow sheathing is rated for exterior use,but you are correct about the protective tape,thanks for you Comment and sharing your knowledge
@brendangill6509 thanks brother 🙏 We look ahead to next year!
@coolmandude100022 күн бұрын
Gray PRO DOPE for the Win. Does not drip like Soup lol. Love your Vids Johnny Sunshine 😊😊
@antzag218822 күн бұрын
Scooby dooby doo
@johnphillipsplumbing714822 күн бұрын
@@antzag2188 tony!
@lets-relax542823 күн бұрын
Thanks a lot. I watch your videos all the time, and I woke up in the middle of the night to take a piss and the Carpenters song was in my head.
@johnphillipsplumbing714823 күн бұрын
@lets-relax5428 Tony's singing too,lol It contagious, 😆 🤣 😂
@isabelfam22 күн бұрын
I’am NO plumber but even I know that does look right 🤷🏻♂️
@petroman-cg8tt22 күн бұрын
John how was the equipment, boilers and pipe on a US Navy Ship, they use to transport me over seas on a Helicopter Carrier, out of Norfolk Virginia back in the late 70's never got to see the boiler room. Great job Joe H Navy SeaBee
@brianmohammed179022 күн бұрын
Hey Johnny cool video and have more video to come next week Monday I will be coming to fl
@anthonyzarcone869623 күн бұрын
Nice save jp . Baaaboom do the guy a solid check the inside piping loosey goosee . Who ever set up that tree was drinking the grey goose 😂😂😂😂😂😂
@johnphillipsplumbing714823 күн бұрын
@@anthonyzarcone8696 exactly 💯 BFMESS
@roberttraylor139223 күн бұрын
good job you did john again you are the master plumber
@GaryBondi23 күн бұрын
Are you allowed to use that flex gas pipe in this situation
@johnphillipsplumbing714823 күн бұрын
@@GaryBondi you tell me!
@GaryBondi23 күн бұрын
@johnphillipsplumbing7148 you are doing the work,you should know....I am not sure
@johnphillipsplumbing714823 күн бұрын
@@GaryBondi read the chapter on gas pipe installation i pinned,then let me know,thanks
@GaryBondi23 күн бұрын
Okay I will read it
@GaryBondi23 күн бұрын
Too technical for me...however if it is stainless steel,it may be used????
@billmonroe882623 күн бұрын
"Something stinks. Must be a lift station or something". As he drives by the outhouse. 🤣
@petroman-cg8tt22 күн бұрын
Thank You John, Joe H Navy SeaBee
@ManonSanchez-j1h23 күн бұрын
Seen same crazy but wow..
@petroman-cg8tt22 күн бұрын
John what brand are the work boots you wear. looking for a good comfortable pair of work boots, I know wear Meindl hiking water proof boots, Which are very expensive but really good boots. I work on oil and propane boilers. furnaces. dig trenches to run lines for the propane in New Jersey. will be relocating to Saint Augustine Florida in the summer my daughter went to flagger college 10 years ago and never came back, Now she teaches there. my wife and i fell in love with it. Thank You Joe H Navy SeaBee
@johnphillipsplumbing714822 күн бұрын
@@petroman-cg8tt WOLVERINE BOOTS,8" MY GO TO!
@robbwallace703423 күн бұрын
Hey Johnny, isn’t that supposed to be black pipe?
@johnphillipsplumbing714823 күн бұрын
@robbwallace7034 no,not in Florida, most supply houses don't even sell black pipe in Florida
@johnphillipsplumbing714823 күн бұрын
@robbwallace7034 I have never seen black pipe in a house in Florida, I have piped many new houses in Sarasota, we only use galvanized, period. You research it if you don't believe me. I was working on an existing system on a new house and it passed final inspection and got a certificate of occupancy. What you do,where you live,does not apply in Florida
@robbwallace703423 күн бұрын
I believe you, just wondering.thanks
@Pipesolutionsinc23 күн бұрын
It needs to be hard pipe, going to the regulator the gas company’s gonna turn it off and lock it when they come to read the meter you should know better than that Johnny✌️
@johnphillipsplumbing714823 күн бұрын
@Pipesolutionsinc the main regulator off of the meter is hard piped,I don't believe it will be an issue, if they have a problem, 2 nipples and a union, do you wanna bet?