Review/Teardown of a East Tester ET431 LCR Meter

  Рет қаралды 15,789

Kerry Wong

Kerry Wong

Күн бұрын

Пікірлер: 60
@vytautasslenderis2702
@vytautasslenderis2702 Жыл бұрын
I have the ET432. And the hardware seems to be different. The microprocessor in my unit is a Nuvoton chip. I do like this LCR meter, very functional. Especially, the ability to perform measurements at 0.1Vrms levels, which does not turn on any semiconductors and therefore in-board measurement of caps, for example, is a treat.
@pault6533
@pault6533 Жыл бұрын
Thank you, I like your understandable and organized delivery of information!
@romancharak3675
@romancharak3675 Жыл бұрын
Thanks for the review, Kerry! I have been needing an LCR meter for some time now, and today, your review helped me take the plunge !
@AIexanderHartdegen
@AIexanderHartdegen 7 ай бұрын
Hello sir, I have now the East tester ET433. This LCR meter is absolutely incredible. Thanks for all your videos.
@pault6533
@pault6533 Жыл бұрын
Today the ET431 arrived. I found the slots in the front of the unit convenient to use for radial lead components or axial ones with the leads bent, no need to use the clips - the manual lists the notches as the first option. I was wondering why you hadn't used this method? Perhaps just for the way you wanted to demonstrate in the demo. I messed around with the setting including "use last" for "Power on set" and proceeded to make my first DCR measurement. I pressed the SPEED button to change from SLOW to MED and THE UNIT FROZE ON ME! No button presses seemed to be recognized. I could not figure out how to reboot or factory reset the unit, but I could turn it on and off, returning to the same screen in a locked-up state. After an hour or so in futility trying to find how to factory reset from the soft keys, I was able to figure that the buttons did work, but the response to a keypress was about 1 minute each press. With patience, I eventually got back to the setting menu and turned it back to "Default value", left the menu, and cycled the power. My unit was unbricked *whew*. So I strongly advise against having the last mode remembered to avoid this endless lockup loop, unless it's really necessary. I found out how to use the record feature and display the running average. This is extremely useful for getting past the constantly changing value on the screen. The tolerance value is also somewhat useful at seeing how much in % the current reading varies from the average or target value. I could see myself using this when tuning a circuit. As for measurement accuracy, I was surprised to find the bathtub curve is rather steep at higher capacitances. My inexpensive meters do much better at high capacitances. Perhaps those meters are able to measure by integration or by having a built-in compensation table. This is my first LCR meter and I bought it for a reasonable price compared to others on the market, but wonder how much more versatile another brand meter would be, or is it the accuracy bathtub limitation true for all of them? For personal use this is adequate, but I think I would tend to use some other device for high or low ranges, such as millohms or higher capacitances. Why is 120 Hz one of the presets when 100 Hz isn't far away? Is it due to some standardized frequency, or due to differences between mains frequency? Should a bias voltage be applied to tantalum capacitors as well as electrolytics? I have been doing so.
@tiagoferreira086
@tiagoferreira086 11 ай бұрын
Typical software issues and bugs on cheap chinese instruments, i have the ET5410+ dc load (same brand as this lcr) and its full of software issues and bugs not to mention the poor hardware assembly and quality, and completely erroneous readings, very negative experience to me, its pure garbage, i won't buy anything else from "east test" (or rebranded) ever again. Fnirsi dpox180h is another trash with completely buggy software. And the list goes on...
@marvinmartian8746
@marvinmartian8746 10 ай бұрын
Just curious if you ever tested your ET431 in DCR mode, but using all the ranges. There is a recent thread over on the eevBlog testing forum about the ET432 (not much different) and two people had the same weird symptoms - oddly varying (orders of magnitude) DCR readings from a 10K resistor. Was wondering if yours had the same symptoms. Auto range usually chooses the correct (accurate) range but there are usually a couple of the manual ranges that will return crazy results.
@alfonso2ff
@alfonso2ff Ай бұрын
Hello, I really liked your posts about electronic bench instruments, especially the East Tester instruments. I just purchased an Esat Tester ET432 LCR and would like to understand how the connectivity between this instrument and the PC is done with the SCPI protocol. I would really like to see a video on this subject. Congratulations and thank you!
@ganrot
@ganrot Жыл бұрын
I live in Europe, the mains voltage is: 230 v 50 Hz, when designing power supplies it is important for me to have at least 50 Hz, and preferably from 10 Hz > 100 kz in 1 Hz steps (when designing audio structures).
@d32b44
@d32b44 3 ай бұрын
Great News! I just got my 433 today, Aug. 18 2024, and they have changed the charging port to USB-C and included the USB-C charge cable
@biogons14
@biogons14 3 ай бұрын
The same with the ET432.
@grerlab2777
@grerlab2777 Жыл бұрын
Always interesting videos... Thanks for the review of this LCR... ✌
@TradeWorks_Construction
@TradeWorks_Construction 7 ай бұрын
If you’re paying for a dedicated LCR why wouldn’t manufacturers build these devices to do capacitor tests in ranges they are designed to operate in? (i.e. 1-50V or have a handful of switchable values that are commonly found on aluminum caps) I might be wrong but I thought electrolytic aluminum caps (that have reason to be suspect) often can still give passable values when tested at lower voltages.
@AnnaVannieuwenhuyse
@AnnaVannieuwenhuyse 2 ай бұрын
There's dedicated capacitor leakage testers for that :)
@ИгорьЗолов-щ7о
@ИгорьЗолов-щ7о Ай бұрын
Thanks!
@alien8r33d
@alien8r33d Жыл бұрын
17:14 Looks like the clips are incorrectly connected to the cap here, red and black are connected to the incorrect pins, assuming red is positive.
@KerryWongBlog
@KerryWongBlog Жыл бұрын
Here the measurement is done using unbiased AC signal so the polarity doesn't matter. When measuring using the electrolytic mode the polarity will be important as I explained the voltage at the tips will have a DC bias.
@alien8r33d
@alien8r33d Жыл бұрын
@@KerryWongBlog I thought you said you were going to use electrolytic mode at that point. The screen shows no bias.
@KerryWongBlog
@KerryWongBlog Жыл бұрын
@@alien8r33d I first measured using the electrolytic mode (check around 14:35, bias is at 500mV) and later on used the standard mode as a comparison.
@alien8r33d
@alien8r33d Жыл бұрын
@@KerryWongBlog I meant to say standard LCR mode, not electrolytic mode. At 16:58, you switched to LCR mode, after testing in electrolytic mode, so no AC or DC bias. Surely RED should be connected to cap + at this point. You connected red to + at 17:04, then removed it at 17:08 and connected it to the negative side of the cap.
@KerryWongBlog
@KerryWongBlog Жыл бұрын
@@alien8r33d Check out 16:26 I was testing in electrolytic mode and the Kelvin clips polarity was correct. I had to adjust the clips afterwards and when in standard LCR mode the polarity really doesn't matter.
@glasslinger
@glasslinger Жыл бұрын
While this is a better value than the Keysight 1733 it still is expensive considering that a Chinese LCR meter for under 20 bucks on ebay will do as good! For serious work a meter like the HP 4275 LCR meter (oldie but goodie!) is much more accurate.
@cong-organic
@cong-organic 2 ай бұрын
How is a $20 meter with 1% accuracy able to compare to 0.2% here?
@glasslinger
@glasslinger 2 ай бұрын
@@cong-organic Both are measured in basic mode without the kelvin test leads.
@sergiocavazos8963
@sergiocavazos8963 15 сағат бұрын
just received ET430, making first tests, and now it's totally FROZEN, ... took the battery out, put it back again, turned on but all keys are unresponsive... anyone knows a way to have this thing reset ??
@lalzova4487
@lalzova4487 Жыл бұрын
Hi ! I lke your video, your naration is very good to follow. Please add review on ET 433 also.
@jspencerg
@jspencerg Жыл бұрын
Hello, I got the ET432 last year and have been using it mostly for capacitors. A few questions, maybe you have some perspective: Should one just use the 100Hz frequency when in the electrolytic mode for determining esr? I'm thinking maybe since electrolytic cap's are not for large frequencies. I don't always have data sheets for ref. Perhaps I'll study sheets for similar caps. I understand kelvin leads should be used for low resistance values, they are not helpful if resistance is high. Is there a similar impedance and/or frequency guidance for inductance and capacitance measurement? I would think using the unit's socket for components, eliminating all wire length, would be best for measuring capacitance. When would using the alligator clips be best practice? There are so many selectable parameters. Almost need a check list as one switches components! Thanks.
@KerryWongBlog
@KerryWongBlog Жыл бұрын
In this case it's 5-wire (4-wire plus guard) measurements. So it's suitable for both low impedance and high impedance measurements. I had made a video a few years back explaining why you'd need guarding when measuring high impedance component (e.g. caps in the pF range): kzbin.info/www/bejne/d561kKujqZh0eKs. If the footprint of the component can fit into the socket obviously it would be the most accurate way to do the measurement as the sockets are also using 4-wire measurements (without the guard, but guard would not be needed since there's no excessive connections in between). ESR for larger capacitors are usually measured at 120 Hz as they are mainly used for mains frequency filtering. You shouldn't see much difference when using 100 Hz or 120 Hz. But if the manufacturer has a specified frequency then that is the frequency you should use.
@jspencerg
@jspencerg Жыл бұрын
@KerryWongBlog @KerryWongBlog Thanks Kerry. I just watched the review of the agilent lcr meter. I was struck by how full the pcb was compared to the ET meter. That one chip on ET lcr replaces so many. I have learned about kelvin leads using my dmm. I'm learning about using guarded lines using my keithley 236. I had not considered the implications of having both on my et432. I'm used to thinking of a DC guard voltage. I found the 5-wire guarded-kelvin layout in the Keysight Impedance Measurement Handbook. I opened the ET's kelvin plug and verified that the guard wire is the outer shield for the 4 coaxial wires bundled in the kelvin 🔌. I'm going to need to think about the different voltage arrangements a bit. Thanks again for your great videos for repair and review.
@neodimium
@neodimium Жыл бұрын
How it compares to DER EE DE 5000?
@KerryWongBlog
@KerryWongBlog Жыл бұрын
I don't have a DE 5000 to compare it to but judging by the spec sheets they are not exactly the same in terms of ranges. Some of the specs are better on the DE and some are better on the ET.
@neodimium
@neodimium Жыл бұрын
@@KerryWongBlog That's interesting. Thanks for reply.
@alia.salman4815
@alia.salman4815 6 ай бұрын
Very nice review ❤
@kenjikawakami8033
@kenjikawakami8033 8 ай бұрын
Great content. Subscribed.
@ergunguler3981
@ergunguler3981 3 ай бұрын
Merhaba. Video için teşekkür ederim. Aynı cihaz bende de var. "RANGE" Seçeneğini anlayamadım. Ne işe yarıyor?
@ioanginsca2330
@ioanginsca2330 8 ай бұрын
Hi, do you the standby/ operating current for this LCR meter ?
@pdh-tech
@pdh-tech Жыл бұрын
Compare the ET431 LCR with the Hantek 1833c you reviewed before (excluding 10kHz vs 100kHz), which is more stable, accurate and functional? Thanks
@KerryWongBlog
@KerryWongBlog Жыл бұрын
The readings are fairly comparable. One thing stood up is the DCR mode in the ET431.
@TYGAMatt
@TYGAMatt Жыл бұрын
Great review. Will the 4 wire adapter fit the Hantek 1832 LCR meter? I was going to make one for my Hantek but just found the ET adapter on Aliexpress so figured that if it fits then maybe just buy that one
@KerryWongBlog
@KerryWongBlog Жыл бұрын
Thanks! Yes, the adapter fits. I have tested the adapter with my Hantek LCR meter as well.
@TYGAMatt
@TYGAMatt Жыл бұрын
@@KerryWongBlog Many thanks for your reply. That's great news. I'll grab one off Ali and save myself some time.
@TYGAMatt
@TYGAMatt Жыл бұрын
@@KerryWongBlog I'm extremely impatient, and as I bought some cheapo Kelvin clips some time ago, and I have some 28awg 2 core shielded cable, I just knocked up a very basic setup. Chopped up three bits of double sided copper clad and soldered the connections. Looks Neanderthal but the first thing I checked after calibrating was a 0.1 ohm resistor that I was struggling with before.... Bang on the money. Then checked a cap and an inductor. Woohoo... What a great result! Just need to tidy things up now. Took 25 mins start to finish. Thanks Kerry. You inspired me to do this and it was definitely worth doing. Now I'll have to make some 4 wire tweezers :-)
@TYGAMatt
@TYGAMatt Жыл бұрын
@@KerryWongBlog What a great day. Couldn't resist it. Pulled my $2, two wire tweezers apart and made them 4 wire. Gotta be happy with that.
@orfeytrue1704
@orfeytrue1704 Жыл бұрын
У меня ET432 и процессор и все детали на плате те же, что и в видео у ET431.
@nbthanhbk2600
@nbthanhbk2600 Жыл бұрын
Et 430b thì tốt ko
@dipakbhalodia7155
@dipakbhalodia7155 10 ай бұрын
Component test in pcb others wise out side test
@s_amoku
@s_amoku Жыл бұрын
DER-EE DE-5000 LCR meter 100 KHz
@KerryWongBlog
@KerryWongBlog Жыл бұрын
ET432, 433 also go up to 100 kHz.
@s_amoku
@s_amoku Жыл бұрын
@@KerryWongBlog DE-5000 is better and cheaper. ET432 is Chinese rubbish, it does not even specify its accuracy!
@jspencerg
@jspencerg Жыл бұрын
​@s_amoku Have you read it's manual?
@cong-organic
@cong-organic 2 ай бұрын
@@s_amoku well it does specify it 0.2%
@alklapaxida850
@alklapaxida850 Жыл бұрын
i am gonna get me one cleedus..
@R50_J0
@R50_J0 Жыл бұрын
Infomercial.
@waitmetherell6664
@waitmetherell6664 Жыл бұрын
"Promo sm"
@egseysfv8976
@egseysfv8976 Жыл бұрын
7m26s you showed that you have no idea what you are talking about. do you know why one meassures 4 wire?
@KerryWongBlog
@KerryWongBlog Жыл бұрын
Sure, 4-wire measurement should produce exact 0 Ohm when Kelvin clips are shorted. But what's wrong with confirming it?
@stevenbliss989
@stevenbliss989 Жыл бұрын
10kHz may be best bang for buck, UNLES you ARE testing switching power supply components, ...i.e. USELESS!!!!!!!!!!!!!!!!!! 100kHZ is MINIMUM!!!!!!!!!!!!!!!!!!!!!!!!!
@egseysfv8976
@egseysfv8976 Жыл бұрын
he has no clue about the instrument and the abilitys i think
@KerryWongBlog
@KerryWongBlog Жыл бұрын
@stevenbliss989 this is a valid statement. Other models in the series (432, 433) do support up to 100 kHz measurement frequency.
Review/Teardown of a Hantek 1833C LCR Meter
23:01
Kerry Wong
Рет қаралды 17 М.
小路飞和小丑也太帅了#家庭#搞笑 #funny #小丑 #cosplay
00:13
家庭搞笑日记
Рет қаралды 17 МЛН
Quando eu quero Sushi (sem desperdiçar) 🍣
00:26
Los Wagners
Рет қаралды 12 МЛН
Как Я Брата ОБМАНУЛ (смешное видео, прикол, юмор, поржать)
00:59
EEVblog 1473 - How Your LCR Meter Works
19:43
EEVblog
Рет қаралды 80 М.
ZOTEK ZOYI ZT-MD1 LCR Tweezers Review/Teardown
21:22
Kerry Wong
Рет қаралды 8 М.
Soviet Multimeter VS. the BEST of the WEST: Tear down & Smack Down!
27:44
The Doubtful Technician
Рет қаралды 27 М.
EEVblog #229 - IET DE-5000 LCR Meter Teardown
18:15
EEVblog
Рет қаралды 116 М.
Every Type of Capacitor for Power Electronics Compared & Analysed
42:15
Understanding LCR Meters
12:42
Rohde Schwarz
Рет қаралды 34 М.
#675 East Tester ET4401 LCR Meter Review And Teardown
37:48
Defpom's Electronics Repair
Рет қаралды 25 М.
小路飞和小丑也太帅了#家庭#搞笑 #funny #小丑 #cosplay
00:13
家庭搞笑日记
Рет қаралды 17 МЛН