Is The Redundancy Factor 1.0 or 1.3 | Kestava 2022

  Рет қаралды 3,679

Kestävä

Kestävä

Күн бұрын

Seismic Design of structures means determining a redundancy factor for your structure. Is the redundancy factor 1.0 or 1.3? Lets ring in the new year of 2022 with Team Kestava and the pursuit of 5000 subs!
Help Kestava spread the love of structural engineering and subscribe!
👇 SUBSCRIBE TO KESTÄVÄ ENGINEERING’S KZbin CHANNEL 👇
/ @kestava_engineering
For business inquiries email: kestavallc@gmail.com
Connect with me on LinkedIn 👇
/ richard-racz-pe-620b1792
Brave Browser 👇
brave.com/
(I am not affiliated or receive compensation from Brave)
Music I Use 👇
www.epidemicso...
.
.
.
.
.
.
.
.
.
Disclaimers: Richard Racz, P.E. does not hold the title "structural engineer". Any claim of it in the videos or descriptions is unintentional and is superseded by the title "civil engineer" in the states of MA and OR.
The Kestävä KZbin page is intended for informational purposes only. Nothing contained in, or provided through, this KZbin page is intended to constitute advice, or to serve as a substitute for the advice of an engineering professional. Any reliance you place on such information is strictly at your own risk.
Under no circumstances will Kestävä be responsible or liable in any way for any content, including but not limited to, any errors or omissions in the content, or for any loss or damage of any kind incurred as a result of any content communicated on this KZbin page.
#seismic #structuralengineering #kestavaengineering

Пікірлер: 14
@narathipkhanhansuk9469
@narathipkhanhansuk9469 3 жыл бұрын
Thank you Rich. Don’t give up on your hard working for us. You help me a lot. 🙏🙏🙏🙏
@Kestava_Engineering
@Kestava_Engineering 3 жыл бұрын
I got you Narathip!
@SouthBayEngr
@SouthBayEngr 2 жыл бұрын
Love your vids man. Recently got my CA PE license and looking to get more structural work under my belt (Passed the hydrology PM). Keep it up!
@Kestava_Engineering
@Kestava_Engineering 2 жыл бұрын
Good stuff lets keep growing our engineering skills together !
@jonathanmorin1382
@jonathanmorin1382 3 жыл бұрын
Man, you should go through the whole ASCE7 with any building case possible with that kind of video quality 😃 I know it's not possible, but let me dream haha
@Kestava_Engineering
@Kestava_Engineering 3 жыл бұрын
love the compliment Jonathan! thanks for being here!
@ehabaltimimi660
@ehabaltimimi660 3 жыл бұрын
This close to SE than PE, but it so good explanation that you did.
@michel8934
@michel8934 6 ай бұрын
Is it possible to have a 4 story building with rho = 1.0 for upper 3 floors, and rho = 1.3 for the ground floor, must we use 1.3 for all floors when any individual floor does not meet the requirements? Thanks
@ainguyentrong5685
@ainguyentrong5685 2 жыл бұрын
How do you determine redundancy factor when calculating story drift for SDC D? Thank you in advance man, your vids are awesome and helpful much for me!
@FilipiMarcondes-r9q
@FilipiMarcondes-r9q Жыл бұрын
hey rich, so if a structure has more than 2 stories and one of those story take less than 34% of the base shear, does it mean I can ignore this on the check for Rho
@Kestava_Engineering
@Kestava_Engineering Жыл бұрын
its a little more complex than that. check out the description in the ASCE 7 and also the commentary has great information on this subject!
@hawsaromerhama725
@hawsaromerhama725 Жыл бұрын
please if you have for example 10 floors it is clear each floor or diaphragm resist less than 35% base shear for example for simplicity each 10% theses condition satisfy if you have a perfect number of shear wall
@mundingbmw4075
@mundingbmw4075 3 жыл бұрын
What apps are you using? Are you using an iPad?
@Kestava_Engineering
@Kestava_Engineering 3 жыл бұрын
nope just my thinkpad computer from like 10 years ago!
Counter-Strike 2 - Новый кс. Cтарый я
13:10
Marmok
Рет қаралды 2,8 МЛН
«Жат бауыр» телехикаясы І 26-бөлім
52:18
Qazaqstan TV / Қазақстан Ұлттық Арнасы
Рет қаралды 434 М.
Caleb Pressley Shows TSA How It’s Done
0:28
Barstool Sports
Рет қаралды 60 МЛН
Response Reduction Factor (R) in Seismic Analysis
16:06
Jhabindra Poudel
Рет қаралды 3 М.
Inside the V3 Nazi Super Gun
19:52
Blue Paw Print
Рет қаралды 3,2 МЛН
What is a Response Spectrum Analysis? and How to use it in Seismic Design of Structures?
12:59
Dr Nafie - Structural Engineering
Рет қаралды 126 М.
Which Stories Should Be Considered For Redundancy Factor?
7:30
If you can solve this, you can be a mechanical engineer
13:27
Engineering Gone Wild
Рет қаралды 20 М.
Civil PE Exam - Welding - Practice Problem
6:52
Kestävä
Рет қаралды 3 М.
3.2 Key Parameters
6:23
DezignArk
Рет қаралды 1,8 М.
Counter-Strike 2 - Новый кс. Cтарый я
13:10
Marmok
Рет қаралды 2,8 МЛН