Know More Risk: Four Types of Water Based Sprinkler Systems

  Рет қаралды 153,379

FM

FM

Күн бұрын

In this video from the FM Global Know More Risk series, learn about the basic differences of the four types of water-based sprinkler systems: wet, dry, deluge and preaction.
To learn more about FM Global learning solutions, visit www.fmglobal.com
FM Global clients can access additional online training 24/7 at training.fmglob...

Пікірлер: 49
@Goldiney
@Goldiney 6 жыл бұрын
Infinitely better than my professional training. They could learn something from the way you teach. Thanks!
@Rob_Nasty
@Rob_Nasty 3 жыл бұрын
Sweet Baby jesus.. This is the most simplistic and beautiful break down in 3 minutes I've ever experienced.
@bcolgate7423
@bcolgate7423 6 жыл бұрын
Thanks for clearing up deluge and preaction. The books don't clearly explain it as well as you did.
@jilurosethomas4977
@jilurosethomas4977 5 жыл бұрын
Hai please suggest me best book for sprinkler fitter licencing exam ? Thanks
@fredbarnich8145
@fredbarnich8145 5 жыл бұрын
Short and simple, thank you
@Darth-Nihilus1
@Darth-Nihilus1 4 жыл бұрын
This has helped me with my advanced fire
@bennyturbo1409
@bennyturbo1409 8 жыл бұрын
Awesome! I can't wait to know more about these systems.
@erinfairservice9702
@erinfairservice9702 6 жыл бұрын
Again, you make it easy to understand.
@sherlockholmes60
@sherlockholmes60 Жыл бұрын
Thanks. I'm studying to take my ARE and this is very helpful.
@imtiyazmod8803
@imtiyazmod8803 9 жыл бұрын
great video sir.Can u please upload video regarding breaching inlet.
@overcomerboy4547
@overcomerboy4547 5 жыл бұрын
Thank you very much. I really learned a lot about sprinklers system
@jayeshshah8504
@jayeshshah8504 2 жыл бұрын
Very good short and clear
@mahanteshkedache393
@mahanteshkedache393 3 жыл бұрын
Thank you for your information
@sherwinagbayani2669
@sherwinagbayani2669 7 жыл бұрын
very informative sir! good job!
@shubhamjat9001
@shubhamjat9001 3 жыл бұрын
Very nice explanation
@marysoliv
@marysoliv 3 жыл бұрын
thank you for share this video
@amandaturner2922
@amandaturner2922 5 жыл бұрын
Great video! Really appreciate it!
@kleptospartan6996
@kleptospartan6996 7 жыл бұрын
Really good Video! Please continue with more
@DelroyDennisUCC--ls2tq
@DelroyDennisUCC--ls2tq 7 жыл бұрын
much useful information
@chrisboone3834
@chrisboone3834 8 жыл бұрын
Thanks for the info i know im gonna pass my test now
@jilurosethomas4977
@jilurosethomas4977 5 жыл бұрын
Hai i am writing my sprinkler fitter exam can u suggest me some books and publication or online study please?
@shafeeshafeeq
@shafeeshafeeq 9 жыл бұрын
thank you sir
@rumildaolik4905
@rumildaolik4905 3 жыл бұрын
good explanation. I still have some confusion with dry pipes system and preaction system. Dry pipe system contains compressed air. The air is released then water starts flowing once the system is triggered. With preaction system the pipe is also filled with air, then water comes into the pipe when the system is triggered. So i do not see the difference. what is the main difference?
@shubhamjat9001
@shubhamjat9001 3 жыл бұрын
The main difference is that ,deluge system is usually for multiple hazards.
@ELITHEFIRST12
@ELITHEFIRST12 2 жыл бұрын
Pre action needs an electronic signal from panel to activate the solenoid and a loss of air for it to trip depending if it is a single action or double action (interlock) system. And a dry system w air just needs a loss of air pressure to trip.
@ikennaogwogwo
@ikennaogwogwo 5 жыл бұрын
great video
@patrickharms6747
@patrickharms6747 4 жыл бұрын
explained it better than my professor
@mahfujkhan5639
@mahfujkhan5639 6 жыл бұрын
very good sir think you.
@juanfighter1
@juanfighter1 7 жыл бұрын
Awesome thanks
@Mazinary
@Mazinary 7 жыл бұрын
thx dear, cool way to give the info :)
@RudeMcNasty
@RudeMcNasty 8 жыл бұрын
Could you do what about high pressure foggy fire suppression? Minimize water damage.
@Linux4Ever2011
@Linux4Ever2011 7 жыл бұрын
Thanks a lot :)
@searchranjith278
@searchranjith278 7 жыл бұрын
In dry type sprinkler,If air enter first it leads to increase the fire..then why we want to use these types of sprinkler
@thankwel
@thankwel 3 жыл бұрын
Hi, need some clarification. Does it mean heat element is used as a detection system for wet/dry system whereas Independent means of detection (sensor) is used for deluge/preaction ? And why there is difference between closed and opened sprinklers ? Appreciate your help 😊
@jjd445
@jjd445 3 жыл бұрын
There are no electronic heat detection devices on a wet or dry system. These two are activated by the link of a sprinkler fusing and opening. An open head is one with a deflector but no fusible link stopping water from flowing through it. A closed one has this link, which breaks upon reaching a certain temperature.
@romeroestrella891
@romeroestrella891 Жыл бұрын
Price list pls all parts of fire splinkler
@laxmangottimukkula561
@laxmangottimukkula561 4 жыл бұрын
Sir i need deep explain of deluge system
@williamking3861
@williamking3861 6 жыл бұрын
ur forgetting about the double interlock system
@ronwikeheiser6706
@ronwikeheiser6706 4 жыл бұрын
What about a flow switch on a wet system?? That will give you a indication of flow
@alisterrebelo9013
@alisterrebelo9013 Жыл бұрын
On a wet system, depending on the water supply source, a flow switch is not a good solution. For example, on a town's main supplied wet sprinkler system, water surges on the supply side can cause the clapper to open and a flow to be detected by the flow switch and therefore call the fire brigade and an expensive bill for a spurious alarm call out. In this case, a fall-in-pressure switch is more reliable as the only time that will operate is if the sprinkler bulb has opened. Granted, someone could knock the sprinkler bulb (accidental or malicious) and set of the pressure switch, this same argument could be applied to a flow switch too. Hope this helps.
@ronwikeheiser6706
@ronwikeheiser6706 Жыл бұрын
For one thing you are talking about a wet alsrm value that yes they can bounce in a water surge that why you have a excess water pump.on the system side to pump the pressure up an extra 40 psi . But this is old school way this system is hardle ever use now days. The system am talking about is a riserr manifold (look this up) ware the flow switch has a test and drain the flow can be set up with up to a 60 second delay for water hammer. Up in Canada this is pretty much what we use on wet systems res com and industrial
@alisterrebelo9013
@alisterrebelo9013 Жыл бұрын
@@ronwikeheiser6706 G'day from an Australian sprinkler system designer (everything in the field to consulting) I do happen to know what you're describing as what we call a 'sprinkler control assembly' used as you've said in residential or office buildings for floor by floor control on a common sprinkler (or combined sprinkler/hydrant) riser. Its not the case that these valves are old school as such. The valves shown are THE way to setup sprinkler assemblies in warehouses, manufacturing, and other high hazard occupancies which is a large proportion of facilities that FM Global insures (that's why they are talking about it). You probably know this, for another, flow switches like the Potter PS120 are unreliable, as the paddle get stuck, they leak, and fiddly to adjust and set. Anyways, not here to start an argument, have a good day sir!
@ronwikeheiser6706
@ronwikeheiser6706 Жыл бұрын
Oh yes l do no what you are talking about as l am a consultant contractor and installer as well for 33yrs . Yes Australia does have a very high standard. As many places have higher standards depending on the insurance company that is over and above here in Canada alam values are just not used here for many reason's as are climate is not easy on things thats all . Things have improved alot over my 33yrs in the business. In no way l am arguing even the piping systems coming out so much has changed from when l was in my early 20s
@str8kronic
@str8kronic 25 күн бұрын
So could you say that all deluge systems are dry systems, but not all dry systems are deluge systems ?
@stevedelaney5652
@stevedelaney5652 4 жыл бұрын
Pressure switch on wet system. Why?
@jjd445
@jjd445 3 жыл бұрын
The pressure switch can be used in place of a flow detector. Flow is detected based on a change in pressure from the static (non flowing) pressure to residual (flowing) pressure.
@yeasinarafat2834
@yeasinarafat2834 3 жыл бұрын
I know the work of fire fitting I am in Kuwait
System Reset: Model F Dry Valve - Dry Pipe Fire Sprinkler System
15:05
Viking Sprinkler
Рет қаралды 29 М.
Every parent is like this ❤️💚💚💜💙
00:10
Like Asiya
Рет қаралды 21 МЛН
Man Mocks Wife's Exercise Routine, Faces Embarrassment at Work #shorts
00:32
Fabiosa Best Lifehacks
Рет қаралды 6 МЛН
Win This Dodgeball Game or DIE…
00:36
Alan Chikin Chow
Рет қаралды 44 МЛН
SHAPALAQ 6 серия / 3 часть #aminkavitaminka #aminak #aminokka #расулшоу
00:59
Аминка Витаминка
Рет қаралды 2,7 МЛН
Know More Risk: Wet System -“ Alarm Check Valve
4:37
Tyco® DV-5A Pre-Action Actuation
3:35
Fire Protection Products from Johnson Controls
Рет қаралды 7 М.
Sprinkler Systems for Firefighters
13:09
Bedford Fire Department
Рет қаралды 141 М.
ITM Double Interlock Preaction System
5:49
Northern Illinois Fire Sprinkler Advisory Board
Рет қаралды 60 М.
Fire Sprinkler Systems Explained
11:29
Stuart Lloyd
Рет қаралды 1,3 МЛН
Know More Risk: Wet System -“ Riser Check Valve
3:08
How Does a Hydraulic Ram Pump Work?
8:56
Practical Engineering
Рет қаралды 7 МЛН
Every parent is like this ❤️💚💚💜💙
00:10
Like Asiya
Рет қаралды 21 МЛН