SHARED NEUTRALS The Dangers of borrowed neutrals, the problems they can cause and some solutions

  Рет қаралды 42,301

LEARN ELECTRICS

LEARN ELECTRICS

Күн бұрын

Пікірлер: 109
@learnelectrics4402
@learnelectrics4402 3 жыл бұрын
SEE ALL OUR VIDEOS To view a list of all our LearnElectrics videos, click on the link below. There are many videos on many electrical topics including Installation, Part P, 18th Edition, Testing, Certification, Lighting, Sockets, Ring Circuits, Calculations and much more. kzbin.info/door/YaJQnpO4XAp0yCgqzMkmfA
@Harold_Shand
@Harold_Shand 3 жыл бұрын
Excellent series. So clear and concise. I'm not even an electrician, just a DIYer with an interest in electrics, so these are very on point. Thank you.
@learnelectrics4402
@learnelectrics4402 3 жыл бұрын
Glad they are useful Gary. Thanks for watching. Lots more to come. Dave.
@bashiruosman473
@bashiruosman473 Жыл бұрын
I am an electrician n from Ghana. I learn more about electricity from you through your KZbin page.
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
That's good to know Bashiru. Keep learning, lots more videos to come. Dave.
@chrissykes7223
@chrissykes7223 3 жыл бұрын
So informative. Plain english. Nothing much like it on KZbin. Keep em coming 👍🏼👍🏼
@learnelectrics4402
@learnelectrics4402 3 жыл бұрын
Thanks for the great feedback. Very much appreciated. Dave.
@johnplummer5139
@johnplummer5139 3 жыл бұрын
Thankyou for taking time to do these excellent video's, the information is super useful and you make it very easy to understand
@learnelectrics4402
@learnelectrics4402 3 жыл бұрын
Thank you John. lots more to come. Dave.
@apackwestbound5946
@apackwestbound5946 Жыл бұрын
Excellent educational material, thank you for producing this material for the rest of us.
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
Glad you enjoyed it, lots more to come and thanks for watching. Dave.
@altuber99_athlete
@altuber99_athlete Жыл бұрын
Hi, excellent explanation and diagrams! Really helpful. However, @ 4:25, I don’t think the problem is the shared neutral, but the open neutral, because if we implement the solution in option #1 (@ 5:34), and the main neutral is still disconnected, then still all of the wires will be energized. What do you think?
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
The open neutral is going to try andffind a path back by sharing with others Thanks for your input and thanks for watching. Dave.
@Dads_reclaimed_his_google
@Dads_reclaimed_his_google Жыл бұрын
You’re a brilliant teacher. Thank you
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
You're very welcome, thank you for watching. Lots more to come.
@isaiahb.5868
@isaiahb.5868 2 жыл бұрын
In america u can share a neutral in some cases. Its called a multi wire branch circuit. If u have a multiwire branch circuit it is required that both circuits disconnect simultaneously. You do this by using a double pole single throw breaker. Where both breakers are connected together at the throw. Thus u cut one off the other automatically cuts off aswell. Only used on equipment though. And if 2 circuits feeding equipment share a neutral one piece of equipment cannot consume more than half of the ampacity of the multi wire branch circuit.
@learnelectrics4402
@learnelectrics4402 2 жыл бұрын
That's different and interesting. Thanks for the input. Dave.
@LarsDennert
@LarsDennert 2 жыл бұрын
That seems to be an danger of shared neutrals as well. Feeding the load of two 20amp breakers on to one 12AWG neutral for instance. Seems you could exceed the capacity of the wire.
@isaiahb.5868
@isaiahb.5868 2 жыл бұрын
@@LarsDennert read the full message again. I explained that part in the last sentence...
@LarsDennert
@LarsDennert 2 жыл бұрын
@@isaiahb.5868 I'm agreeing with you but most people won't notice the danger
@francoisloriot2674
@francoisloriot2674 Жыл бұрын
cannot consume more than half?? how if it's common trip? what will limit the current at half the breaker rating?
@bashiruosman473
@bashiruosman473 Жыл бұрын
Good lecturer. May God increase your knowledge.
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
I hope he does Bashiru. Every day is a learning day for all of us. Dave.
@user-qi8tv2sj4m
@user-qi8tv2sj4m 11 ай бұрын
Thanks mate. Learning this helped today. Your a star.
@learnelectrics4402
@learnelectrics4402 11 ай бұрын
Glad it helped, keep watching. Dave.
@no_short_circuit
@no_short_circuit 3 жыл бұрын
Thanks again for sharing your knowledge. As an adult learner I've never understood why this situation is created in the first place. At 3.50 in the video you say the live feed to the upstairs light is taken from the downstairs lounge lighting. What I don't understand is, if you're running a cable upstairs to the light why don't you run 3-core in the first place. Is it as simple as running in singles to save a bit of cable or did 3 core not exist at that time in the electrical industry?
@learnelectrics4402
@learnelectrics4402 3 жыл бұрын
Old methods and working practices, plus they used the two plate method a lot. looping the live between switches and the neutral between ceiling roses. I just used the lounge switch as an example, it could have come from anywhere. Methods are always changing. Now we are installing smart switches, another change. Thanks for watching, appreciated.
@elitorres1192
@elitorres1192 4 ай бұрын
Excellent sir, thank you for what you do.
@learnelectrics4402
@learnelectrics4402 4 ай бұрын
You are very welcome and thank you for watching. Dave.
@currentsolutions8467
@currentsolutions8467 3 жыл бұрын
Hi Dave. Just would like to thankyou for taking out the time in creating such fantastic videos. Really appreciate it. Can you guide me to the video which you speak about basic and fault protection. Thanks again
@learnelectrics4402
@learnelectrics4402 3 жыл бұрын
There is a section on Basic/fault protection in our exam help video number 10 about Protection for Safety and is on this link ... kzbin.info/www/bejne/m4DWq2mvjLSMp7c Thanks, Dave.
@powerhouse2854
@powerhouse2854 11 ай бұрын
thank you very much now i can send this vid link to explane this problem ...great stuff
@learnelectrics4402
@learnelectrics4402 11 ай бұрын
Glad it helped and thanks for watching. Dave.
@brianmurphy4121
@brianmurphy4121 Ай бұрын
Very helpful. Thank you.
@learnelectrics4402
@learnelectrics4402 Ай бұрын
You're welcome and thanks for watching.
@vince6829
@vince6829 2 жыл бұрын
Nice job explaining this. Thank you.
@learnelectrics4402
@learnelectrics4402 2 жыл бұрын
Glad it was helpful Vince. Thanks.
@dave0smeg
@dave0smeg Жыл бұрын
Had an electrician change the plug in fuse distribution board where we live with a modern RCD board. The single hall light where the board is tripped the breakers, and not the stair lights with changeover switches. To solve it the electrician had to put both lighting circuits onto the same breaker.
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
If the circuits are sharing neutrals this will happen. The RCDs will not see a balanced input and output. Glad its sorted and thanks for watching.
@raymondgarafano8604
@raymondgarafano8604 2 жыл бұрын
Yup, that can be dangerous, say the sparky is on a ladder, the surprise jolt could knock him off the ladder and cause some real pain, however, what if loads were greater than a few lamps? say a vacuum cleaner and an electric skillet and a hair dryer, the overcurrent device may be carrying close to its rated capacity on both circuits but the neutral of one ckt could be carrying a lot more than what its fuse is rated for and the only time a fuse will blow or a breaker trip is when the wire heats up enough to cause a fire, then when neutral touches HOT the breaker trips but the fire has already started.. .
@learnelectrics4402
@learnelectrics4402 2 жыл бұрын
Absolutely. Apparently there are several deaths every year from what happens after the electric shock. The poor guy survives the electric shock part but breaks his neck when he lands on the floor.
@raymondgarafano8604
@raymondgarafano8604 2 жыл бұрын
@@learnelectrics4402 It is not just about shocks, if you share a neutral with another circuit off or of the same phase leg, the currents will add up, say u have 2 15 amp circuits, that would be a 14 gage wire here in the states. the wire is good for 15 amps and is protected by an over-current device for 15 amps. BUT if u share that with another 15 amp circuit neutral on the same phase, (even though the black wire is protected) The current will be doubled on the neutral wire and the heat will be quadrupled 4 times even and THAT will start a fire.
@adamcroft8228
@adamcroft8228 3 жыл бұрын
Great videos and really easy it understand. Thank you
@learnelectrics4402
@learnelectrics4402 3 жыл бұрын
You are very welcome, glad they were useful. Appreciated comments, thank you. Dave.
@vahitatl7933
@vahitatl7933 3 жыл бұрын
Really nice and full of knowledge. Thank you Teacher
@learnelectrics4402
@learnelectrics4402 3 жыл бұрын
Very welcome. Glad you enjoyed it.
@dizzybee7386
@dizzybee7386 Жыл бұрын
Always hit the main switch before undertaking DIY electrical work in an undetermined system.
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
Thanks for watching.
@henrybartlett1986
@henrybartlett1986 3 жыл бұрын
As usual. Really well explained.
@learnelectrics4402
@learnelectrics4402 3 жыл бұрын
thank you. Great comments. Dave.
@electricalstuff259
@electricalstuff259 3 жыл бұрын
Man i love this channel.
@learnelectrics4402
@learnelectrics4402 3 жыл бұрын
Great comment, appreciated. Thank you. Dave.
@krazylad84
@krazylad84 3 жыл бұрын
excellent video as always. hopefully you can create more content on fault finding
@learnelectrics4402
@learnelectrics4402 3 жыл бұрын
Fault finding is on the list. Thanks. Dave.
@raymondgarafano8604
@raymondgarafano8604 2 жыл бұрын
This is for here in the states but there is a so called Chicago3-way for turning a light on from 2 places. it involves putting the hot and neutral on the travelers and light on the commons or poles of the switches, one way is safe as the screwshell is at ground but the other way puts 120 v live on the screwshell of lamp and the NEC prohibits that as of 1923, another style is the Hollywood or California 3-way weird it is but at least the screwshell is on the neutral side.
@learnelectrics4402
@learnelectrics4402 2 жыл бұрын
I like the names Raymond. Thanks for the info and thanks for watching. Dave.
@jeroboamkimtai2099
@jeroboamkimtai2099 3 жыл бұрын
Great illustration.
@learnelectrics4402
@learnelectrics4402 3 жыл бұрын
Thank you, appreciated. Thanks for watching. Dave.
@jeroboamkimtai2099
@jeroboamkimtai2099 3 жыл бұрын
Thanks Dave.
@paborlouise319
@paborlouise319 3 жыл бұрын
Great.... Good job 👍
@learnelectrics4402
@learnelectrics4402 3 жыл бұрын
Thank you Pabor. Thanks for watching. Dave.
@linossinkala7840
@linossinkala7840 Жыл бұрын
Thankyou for the knowledge
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
Thank you, glad you enjoyed it.
@Dr.Stacker
@Dr.Stacker 9 ай бұрын
I found one of my living room lights had its neutral shared with a ring socket circuit, was renovating and had access to move the neutral to a junction box with the kitchen lights, sadly all the lights are on one mcb, but it now works when socket ring mcb is off yey :)
@learnelectrics4402
@learnelectrics4402 8 ай бұрын
Glad to hear that.Thanks for watching. Dave.
@peanutpotion
@peanutpotion 3 жыл бұрын
once again, great video but i have a question. Would you say its worth testing for a borrowed neutral before a board change to save the headache of finding the fault, if so how would you go about this?
@learnelectrics4402
@learnelectrics4402 3 жыл бұрын
It always helps to know the installation before a board change so that you know what to expect. More on fault finding in a soon to be video. Thanks. Dave.
@muniramani
@muniramani 2 жыл бұрын
Meaning to say the diagram at 5.22, the flow can be both ways even though the light is off?
@learnelectrics4402
@learnelectrics4402 2 жыл бұрын
This is the danger with shared neutrals, you think the power is off but parts are still energised. Thanks for watching. Dave.
@DavidBerquist334
@DavidBerquist334 2 жыл бұрын
Is it code along as they are put on opposite legs of the 240
@learnelectrics4402
@learnelectrics4402 2 жыл бұрын
Each circuit should have its own L+N+E conductors. Thanks for watching.
@joshb9657
@joshb9657 Жыл бұрын
Do you have any vids on when the light is switched via the neutral?
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
Take a look at this video on 2 and 3 plate lighting. Switching via neutral is a new one on me, it will leave most of the circuit live. Thanks for the question and thanks for watching. Follow this link ... kzbin.info/www/bejne/hHbNdIuFlL92a8U
@joshb9657
@joshb9657 Жыл бұрын
@@learnelectrics4402 thanks, was on a job today and it had my brain boggled, I sorted it in the end but I don't know how it was blowing up
@Sparky-ww5re
@Sparky-ww5re Жыл бұрын
​​​​​@@learnelectrics4402 Here in the U.S.A, in homes built before WWII typically used knob and tube wiring, and switches were sometimes placed on the neutral side rather than the hot like is required for safety in modern practice. Homes from this era could have dangerous 3 way switches, known as the Carter or Chicago 3 way, the hot and neutral connect to the travellers and the light is switched between on the commons, in one of the 4 switch positions the light is live on both terminals but is not lit. This method was prohibited in the US in 1923 but was used sporadically for many years afterwards , as late as the 1960s in rural areas for switching a yardlight from the house and barn, with receptacles in the barn hot all the time and powered by the house, with only three wires in between, excluding the ground.
@michaelcostello6991
@michaelcostello6991 2 жыл бұрын
Can shared neutrals cause too much current in the neutral. I mean 2 different circuit breakers are supplying that part of the circuit. I know it would be rare but could it happen depending on loads ? Could it be a fire hazard
@learnelectrics4402
@learnelectrics4402 2 жыл бұрын
I suppose if it was 1mm T/E and both breakers were 10A and running at max load. Good point, thanks for the comment. Dave.
@michaelcostello6991
@michaelcostello6991 2 жыл бұрын
Would you suggest not disconnecting the neutral than in case it is shared. That way it is kept at 0 Volts ?
@learnelectrics4402
@learnelectrics4402 2 жыл бұрын
Michael, sometimes you need to disconnect the neutral. We shouldn't be fearful of every neutral being shared. But it does show the importance of proper safe isolation checks.
@currentsolutions8467
@currentsolutions8467 3 жыл бұрын
Hi Dave. Just wanted to know, something regarding extraneous conductive parts. How does an extraneous conductive part become live during a fault. The only item I can think of to make the exposed conductive parts become live is if there is a earth fault on the boiler, which would potentially make the heating system, water and gas pipes to become live. Can you please clarify this. Thanks
@learnelectrics4402
@learnelectrics4402 3 жыл бұрын
good question, have at look at our video - Exposed and extraneous electrical parts - on this link kzbin.info/www/bejne/g6HMqIeFiL5kndk Until the fuse blows, any connected metalwork will become live. If the cooker casing becomes live and that is connected to a metal light fitting through the bonding then that is also at 230 volts until the fuse disconnects. That is what we want to happen for safety. If everything is the same voltage you can't get an electric shock because there is no potential difference to give you one. that is why birds can sit on power lines. Both feet are at 400,000 volts. No difference, no shock.
@currentsolutions8467
@currentsolutions8467 3 жыл бұрын
@@learnelectrics4402 just a minute ago I came across your video which cleared up any of my doubts etc. Again Thanks Dave.
@learnelectrics4402
@learnelectrics4402 3 жыл бұрын
Excellent.
@paulhayles6947
@paulhayles6947 3 жыл бұрын
Anytime I change a consumer unit, 70% of the time the RCD trips when the landing light is switched on. This is because of a borrowed neutral. The only way around it without altering wiring, lifting carpets, chasing, is to put both circuits on the same RCD. This then defeats the original objective of having the lighting circuits on different RCDs. In the event of a fault the property will loose all lighting.
@learnelectrics4402
@learnelectrics4402 3 жыл бұрын
Sometimes we have to make them choices Paul. Make a note of this and if you do a rewire you can sweep this problem up. Thanks for watching and thanks for the useful comment. Dave.
@sunnyhossain3194
@sunnyhossain3194 3 жыл бұрын
Great 👍
@learnelectrics4402
@learnelectrics4402 3 жыл бұрын
Thank you Sunny.
@matthewfewings6023
@matthewfewings6023 3 жыл бұрын
Top video.
@learnelectrics4402
@learnelectrics4402 3 жыл бұрын
Thank you Matthew, appreciated. Dave.
@matthewfewings6023
@matthewfewings6023 3 жыл бұрын
@@learnelectrics4402 no issues I know all about borrowed neutrals but to be fair never crossed my mind it would go live. Common sense when explained. 😀
@learnelectrics4402
@learnelectrics4402 3 жыл бұрын
That's what catches a lot of people out Matthew. Thanks for watching.
@synthwave7
@synthwave7 2 жыл бұрын
I wire my house myself. Add MCB's and wiring, switches etc. DIY
@learnelectrics4402
@learnelectrics4402 2 жыл бұрын
Good luck and stay safe.
@jonesgang
@jonesgang Жыл бұрын
America here where we use split phase 120V circuits for regular outlet and lights for some background. I see a lot of people doing this when they add two separate outlets to their garage and they use 12/3 Romex and 1 20A tandem breaker. They will connect the black and red wire to the breaker, 1 for each half of the tandem breaker, and the single white wire to the neutral bar. This creates a huge imbalance in those circuits. If they are pulling 15A on one of the outlets and 15A on the other that is a total of 30A on the single neutral going back to the panel. 10A higher than the wire is rated for. So not only can it be a shock hazard but also a fire hazard. Now in theory it will balance itself out. The real problem is you can turn off one half of that tandem while keeping the other half energized. So now you have a potential of return power on the neutral. Not sure how many people are aware of just how bad a shock you can get from a shared neutral. It will definitely get your attention.
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
Absolutely right. Thanks for the comments for all to read. Appreciated.
@garyplant487
@garyplant487 3 жыл бұрын
Another M* Presentation Dave, well done...keep them coming...👍
@learnelectrics4402
@learnelectrics4402 3 жыл бұрын
Super feedback. Thanks Gary. How's the house sale coming along.
@tedlahm5740
@tedlahm5740 2 жыл бұрын
The drawing shows the hot of the second (additional) lamp connected to the WRONG SIDE of the switch.
@learnelectrics4402
@learnelectrics4402 2 жыл бұрын
Thanks for your input.
@imevbore
@imevbore Жыл бұрын
I don't share neutral because it gives room to leakage
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
Excellent. Thanks for watching. Dave.
@PR-fk5yb
@PR-fk5yb Жыл бұрын
It seems to me one major problem that is not discussed is the fact that given two branches with 15A each sharing a common neutral would need twice the capacity ie 30A. Given a feed with #14 would require a neutral of #10. Why is not mention as the #1 safety issue? Edit @learnelectrics4402 I am being told that on a common return the feed has to come from a tandem breaker one on each side A and B of the panel. Given this for example 15 A on side A + 15 A on the other side B would cancel out as 0 A phase wise. So the worst case will always be 15 A on the return.
@learnelectrics4402
@learnelectrics4402 Жыл бұрын
Great input. Thanks for watching.
@ifyougetstucklookitup237
@ifyougetstucklookitup237 3 жыл бұрын
Thank you for your efforts again. Really informative video .
@learnelectrics4402
@learnelectrics4402 3 жыл бұрын
Thank you so much. Great feedback.
Branch Circuit, Multiwire, NEC 2020 - [210.4], (19min:38sec)
19:38
MikeHoltNEC
Рет қаралды 247 М.
Жездуха 41-серия
36:26
Million Show
Рет қаралды 5 МЛН
ВЛОГ ДИАНА В ТУРЦИИ
1:31:22
Lady Diana VLOG
Рет қаралды 1,2 МЛН
Почему Катар богатый? #shorts
0:45
Послезавтра
Рет қаралды 2 МЛН
Losing or "Dropping" a Neutral on a 120/240V System
10:28
Taking Measure
Рет қаралды 56 М.
Neutral Imbalance in Multiwire Branch Circuits (Two Hots, One Neutral)
16:41
You CAN Get SHOCKED by a Neutral Wire! This is How...
14:49
Stud Pack
Рет қаралды 853 М.
What is a Lost Neutral? Lost Neutrals demonstrated
12:21
Morgan Inspection Services
Рет қаралды 118 М.
Shared or Borrowed Neutrals on Mains Electricity Circuits
18:15
John Ward (jwflame)
Рет қаралды 374 М.
RCD - RCCB and RCBO Differences explained
10:16
LEARN ELECTRICS
Рет қаралды 67 М.
Does Current Flow Through The Neutral Wire?
7:41
eFIXX
Рет қаралды 342 М.