LG multi v 5 gas charging vrf vrv system how to gas charging R 410a Refrigetion ac me gas charging k

  Рет қаралды 2,115

Royal technical

Royal technical

Күн бұрын

VRF System gas charging kaise kare
VRF VRV gas charging karne ka tarika
HVAC gas charging
how to charging R 410a Refrigetion
how to gas charging R 410a vrv vrf system
how to gas Relief
#how to gas charging air conditioner
vrv air-conditioning gas charging
vrf airconditioning system gas charging

Пікірлер: 30
@royalservice9423
@royalservice9423 Жыл бұрын
👍
@prakashgotame8875
@prakashgotame8875 10 ай бұрын
Sir kyu one indoor control 2 remote controller se one master one salve remote controller aiisa kyu karna padega
@prakashgotame8875
@prakashgotame8875 10 ай бұрын
Sir manlijiya hamara 20 indoor connected haii vrf me 20 me 4 indoor power supply off hoga tyo baki 16 indoor run hoga ki naii sir first me 20 indoor ka system me address garethe aba 16 indoor ka fir address karna pathaya ki naii sir
@royaltechnical5748
@royaltechnical5748 10 ай бұрын
OK 20 indoor hai jis me 16 milgya 4 nahi milraha hai to 16 ko chalu karo bad me 4 indoor chek karo keya problems hai power nahi aarha hai ki commnicetion wiring galat hai keya agra fir 4 indoor me power aagay to thermostat se chalu karo o bhi chalu hojayega addressing nahi karna padega
@prakashgotame8875
@prakashgotame8875 10 ай бұрын
Sir mai bora hu ki 20 indoor me 16 indoor ka ac on haii bt 4 indoor same time me on karne ki jarurrat naii haii fir 16 indoor chalega ki naii ki fir 16 indoor ka liya address karna padega bolra hu
@prakashgotame8875
@prakashgotame8875 10 ай бұрын
Ki 4 indoor ka thermostat tak line paucha rahe bt on karne ki jarurat nai haii
@royaltechnical5748
@royaltechnical5748 10 ай бұрын
Yes
@royaltechnical5748
@royaltechnical5748 10 ай бұрын
@@prakashgotame88754 indoor ka power band kardo chalega
@amitkumarmalhotra2406
@amitkumarmalhotra2406 Жыл бұрын
Hi brother LG multi 5 heat recovery system vaccum karke gas valve open kar diya hai par additional gas nahi dala Kya valve open condition me additional gas daal sakte hai ?
@royaltechnical5748
@royaltechnical5748 Жыл бұрын
Ha
@royaltechnical5748
@royaltechnical5748 Жыл бұрын
Section pipe se dalna liquid line band kardena
@royaltechnical5748
@royaltechnical5748 Жыл бұрын
Machhin chalu kar ke dalna
@amitkumarmalhotra2406
@amitkumarmalhotra2406 Жыл бұрын
@@royaltechnical5748 thanks
@prakashgotame8875
@prakashgotame8875 10 ай бұрын
Sir vrf unit me 20 indoor me 4 indoor ka power supply banda haii vrf me outdoor unit chalaya tyo aur 16 indoor unit run hoga ki naii sir first me 20 indoor connected tha so
@renzogonzalez9068
@renzogonzalez9068 4 ай бұрын
ENGLISH….
How To Replace Air Conditioner Condenser Fan Motor
25:25
Word of Advice TV
Рет қаралды 229 М.
LG vrf multi V4 Error c1,29 Information Step By Step
6:56
Technical adda
Рет қаралды 2,2 М.
龟兔赛跑:好可爱的小乌龟#short #angel #clown
01:00
Super Beauty team
Рет қаралды 56 МЛН
Ouch.. 🤕⚽️
00:25
Celine Dept
Рет қаралды 14 МЛН
Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps, Tips!
27:56
AC Service Tech LLC
Рет қаралды 1,5 МЛН
LGMV HAVC TROUBLESHOOTING LOW REFRIGERANT
30:31
D2D NY Real World HVAC Simplified
Рет қаралды 6 М.
Auto Address LG Multi V 3 (solo) VRF Sistem
10:13
S_Budiyono
Рет қаралды 800
Multi-zone split type Air Conditioner installation
16:49
craftsman tv
Рет қаралды 441 М.
Pump Down - Pump Out, MultiV LG
6:16
PIPSA HUB
Рет қаралды 15 М.
Navegando num Condensador VRF Lg MULTI V IV!
11:17
Anderson Barão VRF - ÁRTICOAR
Рет қаралды 30 М.
Technically Speaking: LG Multi V - Part 1 - Auto Addressing
4:09
Meier Supply
Рет қаралды 42 М.