Anna 35mfd capacitor irukkaa vendiya edaththulaa 50mfd capacitor irundhaa enna aagum pls sollungaa anna
@yuvapandiyans85733 жыл бұрын
Enaku lg 1 ton compressor over heat aguthu capacitor 30+2 irunthathu, and capacitor heat achu so na vera capacitor change panna but compressor on aguthu 5 minite run aguthu apro over heat Ala trip aguthu what problem iruku bro... ithula na new capacitor vangi pota so athuvu heat aguthu bro... connection la correct, condenser block ila, high amps hu ila and fan mattu run aguthu, compressor trip aiduthu, ithu ena problem nu bro please sollunga... capacitor venuna 36+2 try senji pakava...
@kasinathan308 Жыл бұрын
Nice explain
@vigneshwarg30 Жыл бұрын
Split AC motor mattum run panna vaika mudiyungala
@kealsmbalistic34998 ай бұрын
Even if it's not in English, it's very simplistic to grasp. Thank you. Let me see if I can have mine fixed since my technician messed things up with a lame capacitor that has the neutral to the compressor burning all the time.
@theloanranger6689 Жыл бұрын
Tooo good bro very use ful
@sankarsmav2 жыл бұрын
Good Information. But the problem is that you must explain with correct colour code. You have told as GRAY WHEREVER THE CABLE IS BROWN. Please correct. Otherwise, it will be confusing for the people.
@r2_tech_tamil2 жыл бұрын
Yes.. your correct.. but video la drawing potu explain paniruken..
@sankarsmav2 жыл бұрын
Explanation of the drawing which does not match with the physical content will be confusing. It’s like adding black pepper and explaining that chilly powder is added. Please don’t mistake me. My point is that clear presentation will help those who want to learn. Thanks for understanding.
@r2_tech_tamil2 жыл бұрын
Ok.. next time I will try much better'
@santhakumar43782 жыл бұрын
Thank u brother
@thennarasumalar45614 жыл бұрын
Bro,ஒருவுரு ton a/c ku எவ்வளவு gas nu list குடுத்து ஒரு வீடியோ போடுங்க bro
@nesajack2273 жыл бұрын
Very useful video bro
@muthumarees13143 жыл бұрын
Bro capacitor line neutral la atukalam and phase la atugalam mo
@ARMANI-gr2fb3 жыл бұрын
Phase and neutral mathi kodutha motor reverse running
Bro invetar ac R32 and 410 gas how to charging video poduga bro
@rishiganesan12712 жыл бұрын
ஸ்பிலிட் ac lg ல்.1.5டன் சர்வீஸ் பண்ணி ஓடியது indoor unit ஒருவாரம் 10நாட்களுக்கு பிறகு ac போட்டவுடன் 5மினிட்ஸ் ஓடிய பிறகு tripar கீழே இறங்கி off ஆகிவிடுகிறது falt என்ன
@r2_tech_tamil2 жыл бұрын
Ena brand ac.. 5 minutes run agurapo cooling varutha..?
@mohamedbilal61643 жыл бұрын
Brother Keep it up
@vickneshb38419 ай бұрын
Compressor and fan ku common line neutral thana varanum. capacitor input compressor and fan running line ku phase line la poganum nega yan mathe sollureigga 🤔 why?
@r2_tech_tamil9 ай бұрын
Correct bro.. But antha ac la common line la phase kuduthu irunthanga.. Athan apdiye drawing potruken. But common la neutral matum thaan kudukanunu yentha avasiyamum illa.. Phase kodukalam
@vickneshb38419 ай бұрын
@@r2_tech_tamil okay aippo phase and neutral mathe kudutha compressor and fan motor ku problem varaathaa bro
@vickneshb38419 ай бұрын
@@r2_tech_tamilhow do you identify AC fan motor c,s,R terminal. Next, another model fan motor capacitor and phase and neutral ( totally 4 wires) how do you identify Please send your contact number
@Jids284543 жыл бұрын
Thanks
@mohansackthi11694 жыл бұрын
bro "comman"-ல் neutral தானே கனக்ட் பண்ண வேண்டும் என்று சொல்வாங்க இல்லை "phase" வருமா? கப்பாசிட்டாரில் "phase" கனக்ட் பண்ண தேவையில்லையா?
@r2_tech_tamil4 жыл бұрын
no problem bro.. single phase motor ceiling fan ithukelam phase neutral check pani kudukarathila.. athu mathirithan ithuvum.
@mohansackthi11694 жыл бұрын
@@r2_tech_tamil ப்ரோ கப்பாசிட்டருக்கு phase கொடுக்க வேண்டுமா இல்லை neutrala?
@ranjithnatesan98763 жыл бұрын
@@r2_tech_tamil intha Mari connection kuduthu than thappunu soli ena reject panitanga bro
@r2_tech_tamil3 жыл бұрын
intha connection na kudukala.. new Ac la ipdi than wiring irunthaththu.. y ena problem nu sonanga..??
@vadivelmgood68313 жыл бұрын
good explan bro
@kalaiarasansmart14274 жыл бұрын
Super bro
@kothermydeen11903 жыл бұрын
Thank you
@ravfamily86243 жыл бұрын
Anna Duble door fridge wiring pls sollunga
@r2_tech_tamil3 жыл бұрын
upload soon..
@titussays4 жыл бұрын
Nice bro
@surenpeter2563 жыл бұрын
Super
@godwinrajraj91212 жыл бұрын
👌🏻
@prathapkumar20802 жыл бұрын
Hi sir
@prathapkumar20802 жыл бұрын
I am ac fridge iti corse complete sir
@rathinammi58783 жыл бұрын
Bro enga vetu Ac la outdoor unit start aga romba time edukuthu bro apporom start aagura correct time la one second current and voltage low aguthu ithu enna fault bro and yeppadi intha fault rectify pannalam?? Some time compressor start ah aga matikithu pls sollunga bro enna pannalam??
@r2_tech_tamil3 жыл бұрын
EB neutral kedaikama iruntha ipdi problem varaum. EB check paniparunga
@rathinammi58783 жыл бұрын
@@r2_tech_tamiloh ok thanks bro , capacitor weak ahh irutha intha fault vara chance iruka bro??
@r2_tech_tamil3 жыл бұрын
Yes kandipa capacitor weak anulum ipdi agalam.
@rathinammi58783 жыл бұрын
@@r2_tech_tamil oh Okk bro romba thanks bro
@prathapkumar20802 жыл бұрын
Any vagency
@blacktiger95653 жыл бұрын
🙏🙏
@thanustanthanu70363 жыл бұрын
Ellam tanittanija kaladdi lain kuduttu kaddugko
@r2_tech_tamil3 жыл бұрын
Next video la remove pani explain panren
@t.ajithkumart.ajithkumar53332 жыл бұрын
Bro Enkku Oru Duoft
@abuthulsaleemm5753 жыл бұрын
நம்பர் என்னெ
@nationvoice32423 жыл бұрын
Ipadi kolaprhinga please be simple
@r2_tech_tamil3 жыл бұрын
Drawing kooda puriyalaya. ?
@nationvoice32423 жыл бұрын
@@r2_tech_tamil i am electrcian simple a sollama oru single p hase rendu motorku poguthu rendu motor starting coil running coil wire ku nuaduvula capcitor irkum simple la sonna tha namba jankaluku puriyum