🔋Lithium vs. Lead Acid: Voltage vs. State of Charge (SOC)

  Рет қаралды 60,334

Current Connected

Current Connected

Күн бұрын

Пікірлер: 70
@reginaldpotts2037
@reginaldpotts2037 Ай бұрын
No matter what chemistry a voltage chart won't be accurate when a load is being applied to the battery, you have to let the battery rest a while with zero charge/ discharge. Even so, it is more difficult with LFP to ascertain SOC by voltage because the curve is so flat compared to FLA.
@bearchow1929
@bearchow1929 2 жыл бұрын
Your title is wrong. You didn't discuss lead acid at all.
@thomashardin911
@thomashardin911 Жыл бұрын
He is also wrong about the voltages, you can discharge a lfp4 battery to 11v and there is data to prove that, if you’d like…
@boklingvicente1460
@boklingvicente1460 4 ай бұрын
Right, no lead acid battery tested
@philbrooke-little7082
@philbrooke-little7082 8 ай бұрын
The chart is a rested and stable voltage chart it isn’t claimed to be able to give SOC when charging or discharging. BMVs are renowned for being incorrectly set up and for ruining lead acid batteries by people believing them. The problem is them not being synched correctly, having the wrong percentage efficiency set, the wrong tail current, the wrong charged voltage, particularly where solar is part of the mix. The best SOC meters use a combination of coulomb counting and rested voltage as rested voltage can be used to correct the SOC indication when he coulomb counter isn’t being regularly synched with a full charge. Resting voltage charts are actually very useful for showing when BMVs are out of sync and I would say they are an essential check against being misled. You just need to know what they are intended for and use them as such.
@kpd3308
@kpd3308 5 ай бұрын
You are entirely correct. This video is misleading. Anybody should know that battery voltage will be depressed during discharge and elevated during charging. Resting voltage is the key.
@Z-add
@Z-add Ай бұрын
Can you point to a video that explains this correctly
@MrHugemoth
@MrHugemoth 10 ай бұрын
30 years ago I installed a Bogart Engineering cumulative amper hour meter and 500 amp shunt. Its still working after 30 years of 24/7 use. That was on a lead acid battery bank. Just switched to lifepo4 where it also works well at showing state of charge.
@dantronics1682
@dantronics1682 4 ай бұрын
Now considering that a shunt is just a piece of metal, what could go wrong with it?
@Andy-df5fj
@Andy-df5fj 2 жыл бұрын
Isn't that chart resting voltage, not under load voltage?
@JonathanWinterflood
@JonathanWinterflood Жыл бұрын
yes, yes it is...
@freelectron2029
@freelectron2029 8 ай бұрын
yup. this guy has all the gear and no idea. welcome to the internet.
@robertmuster1350
@robertmuster1350 5 ай бұрын
So many people purchase and install LiFePO4 (LFP( batteries and use Lead Acid battery gauges to meter capacity by voltage. The voltage curve of LFP batteries variation is so small, that even at rest, does not give a true indication of capacity. The best capacity measure is using a meter (that is set at full capacity) and a shunt to measure amp hours extracted from and added to the battery.
@Andy-df5fj
@Andy-df5fj 5 ай бұрын
@@robertmuster1350 I agree. The best test being a loaded test is actually true for lead acid batteries as well, at least for general battery health. The issue with loaded tests is that the voltage chart would only be at a very specific load (1C, 2C etc) and with the wide variety of battery capacities, would require a variable load tester and more knowledge/skill to perform the measurements. A simple voltage reading is quick and easy, albeit not the most accurate.
@dantronics1682
@dantronics1682 4 ай бұрын
@@freelectron2029 We'll never know if he has any idea or not but I think he was just trying to sell a named product
@loganv0410
@loganv0410 2 жыл бұрын
WHOA Big Fella. The chart, though horribly wrong as you say, is based on resting voltage. Neither of your curves are, nor can be by the nature of charging and discharging, at resting voltage. I heard you say that you discharged at 50A. What was your charge current? Ah - you're selling coulomb counters.
@HighTechLab
@HighTechLab 2 жыл бұрын
Who, in the middle of using their batteries, shuts everything off for hours "to rest" to figure out how full they are?
@Andy-df5fj
@Andy-df5fj 2 жыл бұрын
@@HighTechLab No one. But many will measure a resting battery to determine its state of charge before using it.
@curtchase3730
@curtchase3730 Жыл бұрын
@@Andy-df5fj That's one thing about lead/acid batteries. Voltage droop is a big thing. The harder the load, the lower the voltage. It sounds crazy, but, yes, in order to get some idea of the SOC of a Lead/acid battery, the load must be disconnected for several minutes at least, then measure the terminal voltage.
@goodman854
@goodman854 Жыл бұрын
yeah sales pitch, lol.
@michaelmedicworldoftanks33fps
@michaelmedicworldoftanks33fps Жыл бұрын
​@@Andy-df5fj exactly
@Sylvan_dB
@Sylvan_dB 2 жыл бұрын
Problem is there are at a minimum 3 voltage:state curves: Under charge, under discharge, at rest for at least 30 minutes. In reality, LiFePO4 voltage is nearly uncorrelated with state of charge.
@josepeixoto3384
@josepeixoto3384 2 ай бұрын
i find Lifepo4's Voltage to represent their SOC with precision; i have 40 lifepo4s(old, CHEAP, 20 of them donnated from non use etc...,some bought USED...) arranged in a 48 volt system working off grid for 2 years nowm i build my own LOW FREQUENCY inverters using the MODDED EGS002 famous control board, only 5 or 6 euros; oh.. and a 3000 watt 23 kg toroidal trafo and the 47microHenry coil of course the voltage is WITHOUT FAIL the SOC, because i KNOW my batteries by now; they are Amazingly Very Consistent.... what a chemistry!!! i just look at the current, in or out, or near zero, and go from there; i know them all, immagine you have 5 or 6 dogs for a while, you´d know them too.
@Sylvan_dB
@Sylvan_dB 2 ай бұрын
@@josepeixoto3384 Nonsense. If you give you a battery there is no way you can measure the voltage and know the state of charge. You cannot change physics. I've had LiFePO4 batteries for 10 years (and lead acid for decades before that). A 100% full charge on LiFePO4 can be anywhere from 13.5 to 14.6 volts, depending on how long the charger has been turned off. If you are currently charging or discharging the curve is entirely different from each other and from an idle battery. While charging or discharging there is only 0.1v difference from 20% to 80% and less than that if the battery is idle.
@ruan2587
@ruan2587 2 жыл бұрын
uhm..so where is the lead acid comparison as per your title?
@50kArchipelagos
@50kArchipelagos 11 ай бұрын
Very helpful. Thx. New owner here. Odd observations explained in that vid. Charger vs. voltmeter vs. display vs. blabla. I'll feel better with the right compensatory readouts. Will do.
@jasonbroom7147
@jasonbroom7147 9 ай бұрын
I have not used either of these Victron shunts, but the problem I've run into with some of the other products is they do not measure smaller draws very well, especially the current an inverter draws while it's on but not powering a load. The end result is you think you have close to 100% SOC, but as soon as you start powering an actual load, that percentage drops very quickly. Do the Victron shunts handle this any better? The problem with what is shown in this video is you're only showing the voltage of the battery while under load. While that is probably a good real-world demonstration, it's somewhat disingenuous because LFP batteries DO show a gradual voltage drop at lower SOC, but you're obfuscating that by having it under a load. Also not mentioned is your 100AH battery won't be a 100AH battery forever...which means if you want an accurate reading from the shunt, you'll have to capacity test and recalibrate the shunt periodically. Most people get way too hung up on knowing the exact SOC of their LFP batteries. Keep them charged up to 80 or 90% and add more capacity, as you are able.
@josephhartman2343
@josephhartman2343 Жыл бұрын
Thanks. Very helpful. I have a an expion battery monitor with expion 360 lithium lithiums and was concerned as my voltage was moving from 13.3 down to 12.5 and still showing plenty of amp hours and 100-90 SOC. This makes total sense.
@chris_mk5supra
@chris_mk5supra Ай бұрын
these voltage are for the battery resting, not when it's drawing energie ... witch WILL make the voltage drop. i mean ... DUHHH
@vevenaneathna
@vevenaneathna 4 ай бұрын
ugh victron. i love how viction charge controllers require you to destroy them if you want to open and replace a fuse or capacitor thats blown.
@SoutheastOhioSolarHaven
@SoutheastOhioSolarHaven 2 жыл бұрын
100 % You have no Idea how many people have argued Battery Voltage is right for Lithium. Lithium Batteries are a different chemistry and monstrous Storage !
@jimhanty8149
@jimhanty8149 7 ай бұрын
Good vid… I don’t see how anyone gets by without a good shunt .. I love my V- 712…
@50kArchipelagos
@50kArchipelagos 11 ай бұрын
It looks like a LiFePO4 can last twice as long if you don't run it below 50%. Is that true?
@louf7178
@louf7178 24 күн бұрын
I take the chart to be for resting voltage, which is after 2 hours, which is a big condition.
@WG7D
@WG7D 2 жыл бұрын
Isn't that chart just for lead acid?
@chadjones99
@chadjones99 2 жыл бұрын
yes
@CurrentConnected
@CurrentConnected 2 жыл бұрын
No it is shared on many websites, forums and Facebook groups as for lithium. With lead acid resting full charge is at 12.8v
@WG7D
@WG7D 2 жыл бұрын
@@CurrentConnected Thanks for clarifying!
@Sylvan_dB
@Sylvan_dB 2 жыл бұрын
@@CurrentConnected With lead-acid the resting full charge is 12.6v. This is a major reason why you cannot parallel lead acid with any lithium chemistry.
@JonathanDFielding
@JonathanDFielding 26 күн бұрын
This is SO MISLEADING! Electrical engineer here. you cannot take your measurement UNDER LOAD (charge or discharge)! Redo your test but when you periodically take voltage measurements, you need to rest the battery for several minutes first before measuring. While discharging it will settle higher, and while charging it will settle lower. This effect is even worse with lead acid batteries. This is called internal resistance and let acid batteries have very high internal resistance.
@last2minutes587
@last2minutes587 10 ай бұрын
where is the lead acid? subject says lithium vs lead acid.
@josepeixoto3384
@josepeixoto3384 2 ай бұрын
Not so with me; you may read my (reply to comment below); from 3.200 to 3.330 you have 130 points to id the SOC,and that is enough; i disregard all methods, except the VOLTS; of course, i correlate to the amps (in ,or out, or near 0), and then, Volts are SOC; i am so used to my 40 cells, on a 48 volt setup, all used, mix and match!!! working well for 2 years, i kind of know them all 16 arrays,one by one now.
@neail5466
@neail5466 Жыл бұрын
Man you are focusing that much on charge voltage but taking the capacity rating as granted !! The device should see some charge and discharge cycles and determine the true capacity. Plus you have plotted the graph on a discharge cycle, that obviously drops the voltage but when you charge the (considering its not floating then the charger will be supplying the power needed, and voltage will not drop, considering provision overhead in that in the charger) but at the charging cycle the voltage shall rise in ball park of that charge. Your point is right when calculating the backup time but probably not when considering charging, still, in that device capacity should be varified through the program.
@erictstahl
@erictstahl 2 жыл бұрын
Great video. Thank you.
@silverismoney
@silverismoney 18 күн бұрын
Sales pitch video that taught me nothing, was technically wrong, and didn't compare lead acids as per the title.
@50kArchipelagos
@50kArchipelagos 11 ай бұрын
So I guess you want an led readout never letting it go below 12.9? if you can't afford the 130.00 shunt.
@landonferguson7282
@landonferguson7282 2 жыл бұрын
What shunt do you recommend for budget builds? Is there one that's cheaper than the 130 dollar victron smart shunt, or is that the cheapest reliable option.
@CurrentConnected
@CurrentConnected 2 жыл бұрын
Victron SmartShunt is the lowest cost & most reliable option we suggest. While some cheaper ones do exist, they certainly are doing it at the sacrifice of accuracy and features.
@landonferguson7282
@landonferguson7282 2 жыл бұрын
@@CurrentConnected I'm very happy with my smart shunt, just wondered about other options. I wish the smart shunt had a simple and low cost screen that connected to the 4 pin port on the shunt, to display the information. The cheapest option for a display I've found is to use a used tablet as a screen for it.
@CurrentConnected
@CurrentConnected 2 жыл бұрын
That tablet is a very expensive screen! For this use case, we have the BMV-712 that only a few bucks more, but it has its own screen you can mount up to 25 feet away for viewing at a quick glance.
@landonferguson7282
@landonferguson7282 2 жыл бұрын
@@CurrentConnected I got the tablet for free, otherwise I wouldn't get one.
@Noah-qt3rq
@Noah-qt3rq Жыл бұрын
The Bogart Engineering trimetric shunt is also quite good, just doesn't have bluetooth. I used it before I got the Victron
@NigelM18
@NigelM18 Жыл бұрын
Interesting, i have a 24v 50ah battery i setup with the infamous chinese shunt and i wanted my battery resting at 80% thats supposed to be 26.65v and the shunt was telling me i was only at 72.6%....... this vid is making sense of it now. I just upped my chage to 26.7v I'll see where the shunt settles now and keep adjusting till i hit 80%
@vroor32
@vroor32 Жыл бұрын
What shunt is that? My shunt won't show the SOC on lithium...😢
@dantronics1682
@dantronics1682 4 ай бұрын
Did anyone explain that a shunt is just a piece of metal? It doesnt matter if its chinese vietnamese or indian. its just a bit of metal with a known resistance
@NigelM18
@NigelM18 4 ай бұрын
@dantronics1682 yeah sure the shunt is just metal but not the electronic controller that's supposed to monitor that piece of metal. Victron vs Chinese..... big difference.
@dantronics1682
@dantronics1682 4 ай бұрын
@@NigelM18 Yep Big difference £200:£40
@Science-Vlog
@Science-Vlog Жыл бұрын
thanks for this nice tutorial
@bwigmytch
@bwigmytch 22 күн бұрын
Lead acid on the title
@gerrymcerlean8432
@gerrymcerlean8432 Жыл бұрын
That shunt must waste a lot of battery capacity. It is constantly converting electrical energy into heat. Doesn't seem like a great idea to me.
@CurrentConnected
@CurrentConnected Жыл бұрын
Not at all. At 100A load it's less than a watt.
@MrTyroneweaver
@MrTyroneweaver 6 ай бұрын
Go Burley Bobcats
@cowboymcq6711
@cowboymcq6711 Жыл бұрын
I’d love to hear a tech from signature solar explain 100 ah batteries LMAO That company is an absolute joke steer clear of them ‼️‼️‼️
@rondhole
@rondhole Жыл бұрын
ONe thing that is very important. Lead acid battery must be above 11.7V all the time before it start degrading from sulphation problems. The Lithium is the other way around, it degrades rapidly if it is close to fully charged.
@CurrentConnected
@CurrentConnected Жыл бұрын
For lead-acid, yes, you are correct. For lithium, not so much. With NMC and NCA chemistry, they do have additional internal stress and degradation when at high state of charge, but for LiFePO4 (LFP), they do not have this issue! In fact, most LFP BMS modules only balance when the battery is at 100%, so by not charging to 100% you get additional degradation and capacity loss from cells being out of balance.
@thedolphin5428
@thedolphin5428 10 ай бұрын
​​@@CurrentConnected Nonsense. "Most Lithium BMSs" (with active balance) can be programmed to balance at any value, but 13.4v is considered good. I recently discharged mine to 10.5v whereupon cells were way out of balance. So I set it to active balance ALL THE WAY UP to 100%. What is the point in ONLY top balancing?
@bethalpha
@bethalpha 3 ай бұрын
. Amazon chargers will destroy lead acid
How To Wire & Program a Victron SmartShunt for LiFePO4 Batteries 🔋
7:29
Current Connected
Рет қаралды 146 М.
🍉😋 #shorts
00:24
Денис Кукояка
Рет қаралды 3 МЛН
Will A Guitar Boat Hold My Weight?
00:20
MrBeast
Рет қаралды 221 МЛН
Шок. Никокадо Авокадо похудел на 110 кг
00:44
What is the best MAX charge voltage for LiFePo4? Tested!
11:42
SolarEngineering
Рет қаралды 88 М.
Victron 500A SmartShunt Battery Monitor Install, Walkthrough & Review
15:08
DEEP CYCLE BATTERY COMPARISON - Is Lithium really worth it?
20:13
Disproving LiFePO4 Battery Misconceptions in my Latest Video's Comment Section
10:03
DIY Solar Power with Will Prowse
Рет қаралды 138 М.
DCS battery! Youtuber Sued for Reviewing this Battery?! Let's Test It!
19:44
DIY Solar Power with Will Prowse
Рет қаралды 656 М.
Lithium Cells in Float Charge. Will it destroy your battery?
20:39
Off-Grid Garage
Рет қаралды 263 М.
🍉😋 #shorts
00:24
Денис Кукояка
Рет қаралды 3 МЛН