Hello friends, this video content is chilled water system issue resolved and identified by Ravishankar in Tamil Lohisya Media
Пікірлер: 75
@sivarenga414110 ай бұрын
தெளிவான விளக்கம் நன்றி அண்ணா.. ❤
@24focusinkeralavlogs7862 ай бұрын
thaks master i working as a big plant supervisior n saudi arabia.. (Zamil cool care) good speech congratulated- very usefully vedio
@balakrishnanramachandran4823 жыл бұрын
Its new and valuable information for me. Thank you so much bro.
@vadivelrock88393 жыл бұрын
Really superb bro 👍..good job..
@sherif84603 жыл бұрын
Excellent ,useful video.
@sankars54083 жыл бұрын
It's like a lot of video post continuous.....thanks
@Davidjebaraj022 жыл бұрын
Spr ji,,,
@guruvendram18443 жыл бұрын
Thank you so much sir....
@perumalrajam48283 жыл бұрын
Super bro ithe mathiri trouble shooting video podunga useful ah irukum
@mraa07rmchannel3 жыл бұрын
Very useful post(video) Sir, Tng
@massvideos87293 жыл бұрын
Super,,,,pls upload more case study....case study neraya upload pannunga ,,,,I am waiting your case study ....pls upload
@Tamilsongs2813 Жыл бұрын
tnx sir good
@coolzonecenter7113 жыл бұрын
Thank u ji..
@senthamilselvan8589 Жыл бұрын
Very useful
@sirajudeen74662 жыл бұрын
Thanks🙏
@mohamedriyasnoor8923 жыл бұрын
Wow super sir ❤️
@thilakt87043 жыл бұрын
Superb bro ❤️
@maranmugilan32452 жыл бұрын
Hi sir thanks for your video. The secondary pump VFD speed manually adjust or Auto adjust ?
@suryapalanivel25803 жыл бұрын
super bro 🎉
@vigneshsrinivasan64303 жыл бұрын
Thanks for video
@kathiravan.k3248 Жыл бұрын
சூப்பரா சொன்னிங்க அண்ணா நன்றி 🙏🙏
@lohisya_media Жыл бұрын
Thankyou
@praveenvenkadachalam31793 жыл бұрын
Bro very useful
@seeniseeni77213 жыл бұрын
Sir nice 👍👍👍👍👍
@divakars74882 жыл бұрын
Best solution for chiller water system ...
@mohamedarshad132 жыл бұрын
Semma
@kskandaraaj46432 жыл бұрын
Actuator: motor drive range could be small. Back flushing: If system installed with two way flow valve around the all chill water system.
@akmkumaran73973 жыл бұрын
Woww
@kskandaraaj46432 жыл бұрын
Hi Sir. I am technician too living in England working in the same industry. AHU Actuator malfunction nothing to do with chiller. What I assume is faulty AHU supply and return air sensor which is operating the chill water flow.
@RaviRavi-pg1iq Жыл бұрын
Bro plate heat exchanger la ethu inlet and ethu outlet eppdi kandupidipathu
@sailokesh54723 жыл бұрын
Sir pls explain chilled water and brine water flow process
@sathishkumar-pc2sm2 жыл бұрын
Sir primary, secondary pump(hp) first eppdi choose pannuvanga? Chiller tonnage vecha epdi nu oru video podunga sir.. Pls......
@kskandaraaj46432 жыл бұрын
What I assume sir. Chill water density could be very high and water not chemically treated well. Also Bottom of the evaporator coil in the chiller blocked with particles not happening normal flow.
@yogeshwarandhamodharan67923 жыл бұрын
But AHU la irukura coilsah yun check pananun la after troubleshooting because control valves vanthruntha ula dust poirukun la
@ravinarasimhan71313 ай бұрын
Why oil level is reducing continuously in macquay chiller
@sureshm9157 Жыл бұрын
Hi anna. HVAC job airportsla entha company contract eduthurukanga, Chennai, kochi, Bangalore airports, airport HVAC job relateda na neraya search panni pathutan, enaku result kedaikamatiku, Ungaluku ethum details therinja sollunga anna
@srinisrini87729 ай бұрын
MUst need motorised bypass valve for two way valve system
@rajphilip43462 жыл бұрын
Anna chiller how change compressor roule
@kskandaraaj46432 жыл бұрын
Sir again another point. Before diagnose the issue . He need to check binder point of inlet and outlet of chill water in the chiller.
@jayaprakashs45872 жыл бұрын
Brother Enakku boiler,chillingplant, ro plant operation theriyum job vacancy irukkuma Iam Be mechanical
@kskandaraaj46432 жыл бұрын
Need to investigate Pressurization system function operating correctly according to pressure differentials..
@arun48463 жыл бұрын
Bro ,we are facing VFD Speed out of range alarm in WCC but we don't the cause
@rameshmuthu22402 жыл бұрын
One vedio full ahu detail solla mudiuma sir
@manimaran-cu3mr3 жыл бұрын
Pls explain the working parameters of decoupler line. its work based on pressure or flow?
@lohisya_media3 жыл бұрын
Working parameters of decoupler line is based on flow
@manimaran-cu3mr3 жыл бұрын
@@lohisya_media thnk U for your response. Your videos was very helpful to our field.
@abouthvac67293 жыл бұрын
Pleased teach heat recovery wheel in FAHU
@kskandaraaj46432 жыл бұрын
Sir ask him to check simple way to investigate the issues. !.Possible Actuator valve motor not installed correctly or small drive range. Chill water air lock .Need back flushing all system ahu and fan coils if two flow valve installed in the plant..
@sherif84603 жыл бұрын
Bro explain gpm
@thakursachin1547 Жыл бұрын
Make vedios in english....so that we can understand too...
@lohisya_media Жыл бұрын
Ok bro
@mohamedsuhaib41193 жыл бұрын
Nanga decoupler with 2 control valve in suction and discharge line and also AHU return line la matum than bypass valve fix aairuku ,,the bypass valve for AHU is connected b/w before and after the control valve in return line only athu yenu solli konjam explain pannunga..in suction header we used airseparator followed by expansion tank after that the return water will go to chiller through primary pumps ,athu yenu nu konjam explain unga WhatsApp number iruntha kudunga nan doubts clarify panna use a irukum I am Mohamed Suhaib currently working in Qatar in O&M. I hope you will reply soon thanks
@lohisya_media3 жыл бұрын
7093786757
@mohamedsuhaib41193 жыл бұрын
@@lohisya_media nandri
@vikiviki62693 жыл бұрын
Bro my question......decoupler line la partial ah open panuna..... AHU's ku flow correct ah kedaikuma....??
@lohisya_media3 жыл бұрын
If your sec pump is in VFD definitely kidaikum
@vikiviki62693 жыл бұрын
@@lohisya_media Hmm correct tha bro... but , If AHU's full load running condition la iruku.. Decoupler line open la iruku.. antha time primary pumps.... chiller outlet la minimum flow of water ah, heat exchange aagaama direct ah inlet la mix pannum pothu..... Chiller cut-off aaga chance irukume..... my question crt ah bro..
@prabakaran952110 ай бұрын
Hardware overload problem solution pls sent me sir
@mohanrajg363 жыл бұрын
Sir please enakku chiller la experience venum job iruntha sollunga sir
@kadharbasha1091 Жыл бұрын
Call IIFM saidapet
@mahendrank97193 жыл бұрын
Sir pls explain Chiller Paramatter pls Sir 🙏
@lohisya_media3 жыл бұрын
Already video available bro
@mahendrank97193 жыл бұрын
@@lohisya_media pls send me link sir
@lohisya_media3 жыл бұрын
kzbin.info/www/bejne/fHawcmiwfJWhiJY
@nanthakumar49303 жыл бұрын
sir pls post Mep Facility Engineer interview questions
@lohisya_media3 жыл бұрын
Tomorrow I will post definitely
@nanthakumar49303 жыл бұрын
@@lohisya_media waiting for the video 🤗 thanks for ur immediate response sir 🙏
@shaikjuned712 Жыл бұрын
Ye video Hindi me banao bhai
@manimanimani7823 жыл бұрын
Hi Anna nan bms irukka enakku oru help venum unga number solluga