sach me mahesh bhai apke jaisa detail me koi nahi samjhata youtube pe... kyunki bahot sare log hai jo chanel chalate hai lekin itna detail me koi nahi jata... bahot log sirf basic me ya defination me lipta dete hai magar apki video sab ke liye sikhne jaisi hoti hai... mai har video dekhta hoon aur samajhta hoon... kyuki mai infra me kam karta ho to mujhe bhi kayi sari problems aati hai magar apke video se problem solve hoti hai... so pls keep doin these videos ... makn ek suggestion dena chahunga ke ho sake to residential ke sath me infra ke components ke upar bhi video banayiye bahot acha hoga...👍👍👍👍
@rajendrakalura.87702 жыл бұрын
सर जी नमस्ते, बहुत ही अच्छी जानकारी दी है आपने, पहली बार ये कपलर मेथड के बारे में पता लगा है, और ये भी पता लगा है वेल्डिंग नुकसान दायक हो सकता है भले ही दिखने में मजबूत हो
@SohanLal-ci3gx3 жыл бұрын
Overlapping provides proper compressive strength in vertical members if laping length is proper.Coupler joints make members in situation but not stand for strength , rebar and coupler bonding may not yield.
@nayanjyotisaharia74203 жыл бұрын
Very Informative Video Sir...Thnxx For The Knowledge....Hamara Ghar Banane Ki Baat Chal raha Hai...Yeh Video Bahut Helpful hoga mere liye
@ankurbhaker7863 жыл бұрын
Precautions while using couplers: • The threads that are being developed on rebars by automatic threading machine must be observed that their length should be appropriate i.e. if the length of rebar coupler is 90 mm so the length of threads should be 45 mm in case of type-1 couplers. For inspection we must deploy an inspector at the steel yard whose duty should be just to inspect the length of the threads in lot of reinforcement before dispatching to the site for installation. • In case of type-1 threaded couplers, the inner threads must be made with a die instead of a lathe as the depth of the cut can be varied by later type of production. • The Contractor may try to hide the excessive threaded portion length on rebar by unacceptable means. Like in one instance, a contractor tried to use cutting disk to grind the excessive threaded portion and then after application of oil used sand to hide the shiny surface. So while inspecting the couplers the excessive length of couplers must be demotivated. • For the quality of reinforcement production at steel yard a full time QC practitioner should be deputed with sufficient experience in terms of reinforcement production for mechanical splices. • The Contractor must evaluate the quotations from different suppliers in terms of cost, quality and timely supply of the product. The approval is granted by the Engineer by thoroughly going through the technical performance certificates or test documentation commenting on the couplers. • The reinforcement bars must be cut by rotatory saw instead of cropping machine. The use of cropping machine results in an inclined end instead of being 90 degree cut therefore in order to engage fully the length of splice coupler the cut angle must be 90 degrees. • For lubrication in the automatic threading machine, only approved lube should be used and no cheap products or water should be used whatsoever. The quality of lubricant would have direct impact on the thread cut otherwise they would be damaged and would be irregular which not a good practice is. • The threads produced on the reinforcing bar must be checked in terms of pitch depth and accuracy. Pitch measuring tool or any other suitable tool might help in determination of suitability of the produced thread.
@Vamshi-k3 жыл бұрын
Io
@engr.asadallahrakha87383 жыл бұрын
Bro if we have to maintain so much things then lapping is best😂
@er.gurlabhsinghgill82542 жыл бұрын
Best explained....please suggest some references to authentic literature/code for future implementations...thanks
@shreekanthraja11332 жыл бұрын
Thks a lot for sharing your experience and me too like you at work place very sincerely as the way you explain above
@rohandoon1235 Жыл бұрын
Can we contact you
@k.p.s.19592 жыл бұрын
बहुत सुंदर जानकारी :- सकलानी बिल्डिंग कन्स्ट्रक्शन
@pravinshaha54752 жыл бұрын
Coupling is the best 👍 as per my 45 years experience in Mega Engineering Structure Pravin Shaha, Chartered Engineer and Government Approved Valuers
@raghubanshprajapati5307 Жыл бұрын
@SP CREATION'S kitna price hota
@BilalAhmad-vl1ozАй бұрын
Main Saudi Arab main kaam karta hou jis building 🏢 main hum kaam karty hai os main Pora Coupler ka System hai Pory 53 chaat bane ge. So i think coupler joint is 100% best than others joints I am from Pakistan and watching your video from Saudi Arabia . Great work 👏👏
@sampathr24 жыл бұрын
Really wonderful explanation. For a layman like me, it is explained in simple and short. Tks for sharing.
@rahibulhoque43973 жыл бұрын
Rahibul
@wajid6994 жыл бұрын
We always do lapping..coupling to pehle bar suna hai...fir bhi good video sir
@ImranSharif-z3t8 ай бұрын
he said lapping is ok till M16 ABOVE M16 BETTER USE COUPLER, WELDING IS NOT GOOD FOR ANY CONDITION. THANKS
@sanjaysrivastav33333 жыл бұрын
Lapping is best. Coupling is very careful work and it needs skilled worker and sincere supervision. Needs threading which will take extra cost. So work may be delayed. More need of coupling is best for complete load transfer without eccentricity.
@lovekeshsanwriya45973 жыл бұрын
वा भाई ...भाई ने कुछ नया किया 👍👍👍
@aishyadavvideos3 жыл бұрын
Always explain in a good manner .
@mokbulhossain59263 жыл бұрын
ঈশ্বর ঈশ্বরকে,
@nagaraj53382 жыл бұрын
Good innovation by using cupling method, super saver
@rahilshaikh4394 жыл бұрын
Sir cupling best option hain you right and thanks
@rameshwarbeldar35342 жыл бұрын
अप्रतिम माहिती सर 🌷🌹🙏🙏
@kanhaiyakumar-ur7rc4 жыл бұрын
Very very important video sir❤️
@ManishPuri3 жыл бұрын
Good information bro
@manits35474 жыл бұрын
Welding is acceptable with both sides welded in double layers duly chipped of. In this case the overlap will be normally 10 X Dia. of Bar or as per Designer's specification. The Weld is further subjected NDT / X-RAY confirmation for perfect welding. But Weldind is not unacceptable under any circumstances.
@Ranjeetkachhwaha Жыл бұрын
First time see its important video Thanx Sir
@shyamchaudhary.33594 жыл бұрын
We are using lapping , in coupler use less steel but lapping is best, more stronger than coupler....
@moharsai5278Ай бұрын
बहुत अच्छा जानकारी है सर
@skumar10144 жыл бұрын
In your next video- 1. Explain cost advantages of handling of heavier bars due to lapping, cost of additional handling due to threading machine. 2. Cost of threading machine, Cost of threading per bar and productivity of machine 3. Labour cost savings if couplers are used
Over lapping is commonly used in building construction. So in my opinion lapping is best to transfer the load one bar to another bar
@motipatel6153 жыл бұрын
Wah news great job sir....
@viralcat-w4x Жыл бұрын
Couplers are the best regarding strength, serviceability, ductility, and stiffness. Past research also shows that the stiffness of the coupler splicing region is even HIGHER than that of a continuous reinforcement due to the cross-section enlargement at the coupler location.
@bk.gyanesh25532 жыл бұрын
Very very nice information thank you sir ji 🙏🙏🙏🙏🙏🙏
@RNGunding4 жыл бұрын
Very informative. Thanks.
@borntoride22094 жыл бұрын
lapping is best because cost is not important than life of people.. lapping has given instructions in is codes 50d for slab , 24 to 40 d for coloumn , for beam tension 45d, compression 24d and the distance center to center of lapping length should be 1.3 times of lapp length
@esportzgaming1140 Жыл бұрын
More than 36 mm ?
@AmanKumar-sf8it Жыл бұрын
WONDERFUL EXPLANATION
@janardhanreddybanala37784 жыл бұрын
Vertical bars coupling is ok what about horizontal bars coupling is acceptable or not ?
@vijaykumhar94034 жыл бұрын
Good question
@Amit-yb4sd4 жыл бұрын
Sir for horizontal joints lapping is recommended
@janardhanreddybanala37784 жыл бұрын
Amit thank you 🙏🏻
@Amit-yb4sd4 жыл бұрын
@@janardhanreddybanala3778 sir lapping for horizontal bars can be done only in columns, other than column, lapping cannot be done in the middle of the beams, so couplers dont work ...
@brijeshsharma43254 жыл бұрын
Yes gud question
@civilengnepal4 ай бұрын
learn everyday ! very good content sirji !
@SohanLal-ci3gx3 жыл бұрын
Only over lapping is effective.other aulternates like welding , coupling,the vertcal element(column) may shear up, horizontal element( beam) may effect tensile strength as well as compressive strength.
@borntoride22094 жыл бұрын
nice video brother good coupling is also good it reduces cost but i cant feel safe
@chttaranjansarkar40983 жыл бұрын
Lapping ache
@ShyamPrasad-A-Love-S Жыл бұрын
So super very nice video 👌❤️🌹👍
@mukuljha8044 жыл бұрын
GREAT INFORMATION.THANK YOU SIR JI.
@lotsofgaming92073 жыл бұрын
Sir very useful good information
@maheshj6604 жыл бұрын
Sir , In case coupler joint came in beam junction or slab area is technically wrong ???
@bikramjit154 жыл бұрын
Thank you very much Sir 👍👍👍👌👌👌😊😊😊
@jaimabharti91824 жыл бұрын
Lapping is best.
@rai_vloger52902 жыл бұрын
Tab shyad apne video nhi dekha
@aamirthesinger00072 жыл бұрын
It depends
@basimmohammad5299 Жыл бұрын
Upto 36dia
@vertexmalakar Жыл бұрын
Tino best hain bash sahi jagah sahi terike se karna chahiye
@ak_homes_design4 жыл бұрын
Useful Video Sir .......
@jaydevmandal44163 жыл бұрын
Coupling is best
@saileshsingh14 жыл бұрын
You always bring practical and great topic! Thank you from Bottom of my heart.. Can you plz bring something on topic FAR.. Jaye Krishna Janma Asthami! Thank You. Shailesh Singh
@LearningCivilTechnology4 жыл бұрын
Sure... Jai Shree Krishna
@ishadulhaque31303 жыл бұрын
1st Lapping is best and strong 2,rd over Steell lapping is good but not using the bending oir the over lapping Steel welding is a very good option and strong 👍 I am Ishadul building construction senior worker from the Kerala 10 20 30 40 floor building overlapping Welding system work
@biswapramanik2214 жыл бұрын
I love you sir ji ❤️ important education
@Merabharat92544 жыл бұрын
Very nice technique
@prabujayk4 жыл бұрын
daily I am watching your videos. I learned lot of information in your chanel. In this video Can u please explain how we can threading for tmt steel ? Threaded steel Is readily available in market with coupling?
@zohebimran75934 жыл бұрын
To use couplers,rebar should be forging and treading. For basic couplers, its 2 type of treading half length of couplers tread in rebar its called type A. Full length of couplers treading in rebar its called type B. Type A for vertical bars n B is for horizontal bars.
@Life_is_Awesome_Civil2 жыл бұрын
Very nice
@LearningCivilTechnology2 жыл бұрын
Thank you sir 😊
@ajayhaldwani58503 жыл бұрын
Coupling available hai market main sir best idea coupling
@kolamallik51854 жыл бұрын
Good explanation. Thank you sir
@rsd63174 жыл бұрын
Coupling- Cost of making threads ? How far it is economical and practical?
@LearningCivilTechnology4 жыл бұрын
Soon video will come
@naukheznomani2792 Жыл бұрын
Case of Heavy dense reinforcement work can use self compacted concrete or smart dinamic concrete (Japan technology based). And in which use hammering instead of vibrator.
@Tour_and_Knowledges3 жыл бұрын
For couple we need to get rod threaded that can also increase cost
@Sneha1235-u2q3 жыл бұрын
And also take time.
@abhishekthakur85732 жыл бұрын
Kya baat hai sir mauj kar di fir se
@Boss-gk8kc4 жыл бұрын
Hi I really enjoy your videos. You explain things very well. I have a question; what if lapping method is used but the bar is not bent to make stagger ie it’s just joined straight , is that safe? Is it ok according to IS code ?
@rahulbadgandi3 жыл бұрын
No boss
@KaushalKaushal-wu9lb9 ай бұрын
Popular ek hi Jagah joint Hota Hai
@SurajKumar-rw7gd3 жыл бұрын
You are great👍
@karthikgowda35304 жыл бұрын
High pressure gas welding is the best and cost-efficient
@हिन्दुराष्ट्र-ङ3ण2 жыл бұрын
बढ़िया जानकारी
@abhikhatri54144 жыл бұрын
Coupling is recommended for column and lapping is recommended for beam but not coupling and also welding is not recommended for either of ...
@sanmukhchauhan16683 жыл бұрын
Very good idea bhai
@henrykharnaior57863 жыл бұрын
Lapping is the best coZ we are in the quake zone 🙏🙏🙏🙏coupling is dangerous
@अजयकुमार-झ7फ4ल3 жыл бұрын
.
@sameerbabu18563 жыл бұрын
Very good video Sir
@taringsanjay98463 жыл бұрын
Make a vedio on estimated comparison on this top
@LearningCivilTechnology3 жыл бұрын
Video banaya hua hain
@aishyadavvideos3 жыл бұрын
Excellent explanation
@simrankaur-nx3wr4 жыл бұрын
Amazing sir 🙏🙏
@davidrajumamilla1254 жыл бұрын
Lapping is Right
@Joker-gh2eh9 ай бұрын
I am Muslim from Bangladesh, you are great explainer
@raushankumarjaisiriram81883 жыл бұрын
सर रड में गुना के लिए बताएं,,👍👍
@FilmiBate_2.13 жыл бұрын
गुना मतलब ??
@RizwanKhan-we9rr3 жыл бұрын
Yes sir coupling is very best option
@virandergoswami18114 жыл бұрын
What if dia of same vertical bar is to be reduced in case of columns for upper storeys....will coupling work?
@LearningCivilTechnology4 жыл бұрын
Yes
@khajaismailmohiuddin29254 жыл бұрын
@@LearningCivilTechnology but it is very complicated and difficult task to make threading for both Lower and upper bars.what is the solution?
@akkatfiresafety85673 жыл бұрын
Very good information .Thanks
@yashaggarwal71052 жыл бұрын
Coupling may be good for column/pillar but not for horizontal beams
@travelguide7862 жыл бұрын
Correct
@Standwiththehindus4 жыл бұрын
Thank you for the valuable information. Jai Shree Krishna
@ArchiDesignHub4 жыл бұрын
Lapping, ❤❤💯
@subhamkundu6204 жыл бұрын
Really good explanation sir, I liked it. But I had a question that does coupler is a good option in terms of stability of the suructure.
@pynzkurbz37963 жыл бұрын
I don't think so
@nanduxyz61692 жыл бұрын
leping is tha best option 👌👌👌👌
@AakashDudwe162 жыл бұрын
Lapping my best👍💯 choice system
@rurutarkar82034 жыл бұрын
क्या सभी साइज की स्टील मैं कपलर use kr सकते है ????
@shuyebsiddiqui87273 жыл бұрын
Good information sir
@samj9234 жыл бұрын
Welding in image is worst and wrong construction.. Lapping is the correct procedure to increase height
@khudirammunda59272 жыл бұрын
Coupling is best 👍👍👍
@arunannamalai70354 жыл бұрын
Welding is not recommended for reinforcement lapping as it alters the material properties of the reinforcement due to heat produced during welding. Also there is reduction in the cross section of the reinforcement
@jahirabbas27323 жыл бұрын
Very good explanation
@satyaallidona4 жыл бұрын
LAPPING IS BEST
@shayekchowdhury81893 ай бұрын
😂
@khawlajamshaid53032 жыл бұрын
Very good sir thank you
@nakulakoushalya69764 жыл бұрын
Lapping is right
@manmohannegi30624 жыл бұрын
coupler is good or no?
@ManishPuri3 жыл бұрын
NYC bro
@borntolive20974 жыл бұрын
Very informative video..will wait for your next video of price comparison between using couplers and providing lapping length for higher diameter steel
@rupinderkaur81642 жыл бұрын
Nice video good knowledge
@faheemahmad9454 жыл бұрын
I hope lapping is best for safety
@suhanisingh37702 жыл бұрын
बहुतअचछीतरहसेसमझाए सर
@sonushahjahan54464 жыл бұрын
Dear Sir 1 Question hai Sir Difference between Pile Foundation And Raft Foundation 2. Question. Pile Foundation And Raft Foundation which Area me karte hai. Please sir Give me Ans.
@vikashkumargupta39554 жыл бұрын
Q1) pile fondation:- below the ground level and used in breeze but Raft or mat foundation both are same used in appartments.it is generally used in that area where soil strata has low bearing capacity.
@q138mahtorahul4 Жыл бұрын
Thanks bhai ❤❤❤❤❤
@shahidulislamshumon43834 жыл бұрын
Thank you. I want to know about DPC. Please do a video on DPC.
@laxmanrajofficial33892 жыл бұрын
Bahut achhi know sir
@manasmohanta73554 жыл бұрын
Drawback in coupling is to makeing thread on steel bar in leathe which is costly
@ImranSharif-z3t8 ай бұрын
very nice explanation keep it up. regards
@Ritesh_kumar_0074 жыл бұрын
Sir, share something related to highway engineering also.