Magnetic balance test of transformer

  Рет қаралды 40,452

Electrical and Electronic tech

Electrical and Electronic tech

Күн бұрын

We learn in this video, magnetic balance test of transformer and calculation

Пікірлер
@khannaushad9177
@khannaushad9177 3 жыл бұрын
Very good video and other transformer maintenance. full details ir test winding resistance test ke sath
@navanee6563
@navanee6563 5 жыл бұрын
Dear Sir, Your way of teaching is easily understandable and practically what we are doing same you are showing. Please share remaining transformer test also
@jacobephraim6920
@jacobephraim6920 3 жыл бұрын
instablaster...
@raghupathim9691
@raghupathim9691 Жыл бұрын
Thanks and appreciation your efforts. I Could understand easily. Pls make more useful videos like this..
@kamleshmaheriya2366
@kamleshmaheriya2366 7 ай бұрын
Very nice explanation sir
@amitpagare5946
@amitpagare5946 2 жыл бұрын
Very useful video 🙏🙏🙏
@arunjoshi8619
@arunjoshi8619 3 жыл бұрын
Nice
@akashmaity794
@akashmaity794 3 жыл бұрын
sir thank u ap bohot aache se samjhaye
@parmodyadav9966
@parmodyadav9966 3 ай бұрын
Sir kyaa single phase bhi supply lekar checking kar sakte hai
@omyadav9280
@omyadav9280 5 жыл бұрын
Very nice vdo sir
@washimakram8152
@washimakram8152 3 жыл бұрын
Upload video of all testing of transformer..
@ashoktiwari2159
@ashoktiwari2159 9 ай бұрын
Sir open circuit and short circuit ka practical karaye
@moharsingh7256
@moharsingh7256 4 жыл бұрын
Megar motor konsa lena chahiye
@memsadda9705
@memsadda9705 2 ай бұрын
Sir kitna percent voltage unbalance acceptebale hai.
@odiamediumclass1565
@odiamediumclass1565 Жыл бұрын
Thank you sir...
@ZYXYZLF
@ZYXYZLF 2 жыл бұрын
Hi, 1. During the test can we use single phase supply behalf of three phase? 2. During the testing are we taking secondary side LV side readings ? THANKS 😊
@merajislam54
@merajislam54 11 ай бұрын
Sir, Assalamualaikum Your teaching technique is so easy & different to each others. I am from Bangladesh. I am a big fan of you & your youtube page EET. #respect🥰
@ElectricalandElectronictech
@ElectricalandElectronictech 11 ай бұрын
Thank you,🤝
@kushwaharaj3577
@kushwaharaj3577 2 жыл бұрын
Sir voltage & current check q nhi kiye ek hi sath me dono ho jata n
@mdshahidanwar6443
@mdshahidanwar6443 3 жыл бұрын
How many test can we perform for our Annual Maintenance for TR
@giasuddinchowdhury4248
@giasuddinchowdhury4248 3 жыл бұрын
sir thank you
@arifpathan7787
@arifpathan7787 4 жыл бұрын
Sir, induction motor overhauling ka video upload kijiye with full explains.
@kalaiselvanp9180
@kalaiselvanp9180 4 жыл бұрын
Dear Sir Your videos are super and easy understandable. In case of single phase supply how to test Magnetic balance test.
@ElectricalandElectronictech
@ElectricalandElectronictech 4 жыл бұрын
Thank you, I will publish video about it
@tube007007007
@tube007007007 Жыл бұрын
What is the current rating of the 1 pole MCb connected to each phase of the HV side ?
@ElectricalandElectronictech
@ElectricalandElectronictech Жыл бұрын
6 amp MCB or 4 amp
@shantapriyajena606
@shantapriyajena606 4 жыл бұрын
Can we do the testing for secondary side also???
@parmodyadav9966
@parmodyadav9966 13 күн бұрын
Value kitne aani chahiye.
@adarshenterprise5987
@adarshenterprise5987 3 жыл бұрын
Sir , kindly do testing and analysis for star connection
@ElectricalandElectronictech
@ElectricalandElectronictech 3 жыл бұрын
Transformer magnetic balance test in star connection, click link 👇 kzbin.info/www/bejne/hGOTnZWke8eHibc
@mkanish0001
@mkanish0001 4 жыл бұрын
Thanks sir
@manishsingh6130
@manishsingh6130 4 жыл бұрын
Sir this magnetic balance varies with voltage ration of transformer. In higher rating tranformer like 33/400 kV transformers voltage applied in one limb will not be equal to voltage induced in other two limbs. Infact for these high rating transformers voltages will be high on adding
@atulchaturvedi3616
@atulchaturvedi3616 3 жыл бұрын
How to perform meganetisng current test on single phase transformer
@ElectricalandElectronictech
@ElectricalandElectronictech 3 жыл бұрын
Magnetic balance test is conducted only in three phase transformer. because to know three phase winding balance is ok or not. The test not required for single phase transformer.
@ManmeetSingh-mk1ds
@ManmeetSingh-mk1ds 3 жыл бұрын
What is the maximum discrepancy which can be acceptable. Here it's 1 to 2 volt . If it is range of 7 to 8 volt then is it ok
@ElectricalandElectronictech
@ElectricalandElectronictech 3 жыл бұрын
No,if it is above 2 volt ,some problem in winding .it may be unbalance no of turn ,core problem etc.
@rajvaghadiya8814
@rajvaghadiya8814 4 жыл бұрын
Sir eesme tap change jab 3no MCB ek ek baar bandh ho jaye tab change karne hai naa
@ElectricalandElectronictech
@ElectricalandElectronictech 4 жыл бұрын
No need to change tap, you complete this three mcb in one tap only, if you want to check another tap ,you do same procedure in another tap also
@nikhilduggani3766
@nikhilduggani3766 4 жыл бұрын
Sir, we have not taken into consideration about the lv side in this process....what will happen on lv side during this ....if I measure line voltage
@ElectricalandElectronictech
@ElectricalandElectronictech 4 жыл бұрын
The test conduct for ,is the transformer magnetically balance or not. If any turn to turn short or other any disturbance,the balance voltage also changed. The test conduct in any one side.if we make test at LT side,high voltage induced in primary side that's why the test conduct in HT side
@mitubarik3361
@mitubarik3361 3 жыл бұрын
@@ElectricalandElectronictech phir sir LV side ka magnetic balance test kese hota hai
@atulchaturvedi3616
@atulchaturvedi3616 3 жыл бұрын
What is the difference between magnetic balance test and meganetising current test
@ElectricalandElectronictech
@ElectricalandElectronictech 3 жыл бұрын
To know magnetic circuit balance of three winding by magnetic balance test. To know defects core,turn to turn short, winding shifting,tap changer problem by magnetizing current test
@pradipgajbhiye6910
@pradipgajbhiye6910 6 ай бұрын
What happened when voltage in any phase came 10% less
@ElectricalandElectronictech
@ElectricalandElectronictech 4 ай бұрын
If voltage unbalanced, current also will be unbalanced So chance to trip in earth fault
@praveenkumarpalaparthi8124
@praveenkumarpalaparthi8124 3 жыл бұрын
It's a star or Delta connection?..
@ElectricalandElectronictech
@ElectricalandElectronictech 3 жыл бұрын
It is Delta connection,if star connection, you can see my star connection magnetic balance test video,it was already published .
@ElectricalandElectronictech
@ElectricalandElectronictech 3 жыл бұрын
Please click link 👇 to watch star connection magnetic balance test kzbin.info/www/bejne/hGOTnZWke8eHibc
@arjalavamsi7669
@arjalavamsi7669 5 жыл бұрын
Sir LT winding open or not... I won't get point video How to connect neutral ....
@ElectricalandElectronictech
@ElectricalandElectronictech 5 жыл бұрын
Thanks for your comment, all connections are open in L. T&neutral side and H. T side also, only 420volt apply in H. T side through mcb.
@arjalavamsi7669
@arjalavamsi7669 5 жыл бұрын
@@ElectricalandElectronictech Thanks for response... Now i have clear my doubt
@pateljay9011
@pateljay9011 4 жыл бұрын
Mcb kitne amp ki leni hai?
@ElectricalandElectronictech
@ElectricalandElectronictech 4 жыл бұрын
4 Amp can use
@harpreetsharma7070
@harpreetsharma7070 2 жыл бұрын
Turn ratio test performed
@atharpasha3013
@atharpasha3013 5 жыл бұрын
Lv side kar sakte hain kya
@ElectricalandElectronictech
@ElectricalandElectronictech 5 жыл бұрын
L. V side me bhi Kar sakta hai ,lekin H. V side me high voltage produce hoga, safety se karna hoga.
@anilkumarshah4523
@anilkumarshah4523 4 жыл бұрын
Sir LV side me kaise magnetic balance test karenge please sir batane ki kirpa kare
@ElectricalandElectronictech
@ElectricalandElectronictech 4 жыл бұрын
Apply voltage 440 v 3 phase on LV side,and do same procedure as a video.but carefully, because HV side induce high voltage. If any doubt send WhatsApp 8248719700
@ElectricalandElectronictech
@ElectricalandElectronictech 4 жыл бұрын
Open neutral connection from earthing
@MsAns24
@MsAns24 5 жыл бұрын
Dear Sir what if voltage sum across two pair of phases is equal to applied voltage across one pair of phase but across one pair of phase voltage is zero.
@vivekpatni709
@vivekpatni709 4 жыл бұрын
Sir मेगर testing के लिए कौन सा digital मेगर लेना चाहिए, जिससे power & distribution दोनों transformer test हो जाये Plz बताये...
@mohammedsharukh3428
@mohammedsharukh3428 5 жыл бұрын
What if the voltage difference is 30 - 40 volts, and reason for difference.
@kalimkhan4248
@kalimkhan4248 3 жыл бұрын
Bhai starting me bataya to hai ki turn's short hai
@mdsen4103
@mdsen4103 2 жыл бұрын
Voltage add karna solution nahi hai.aapne galat bataya hai.. voltage should be as it is RY 415,.(100PC) YB 300,(70 PC) BR 115(30 PC). while YB voltage applied 415 it should be equally devide.center limb .BR will show apposite of RY because of magnetic field distances di.
@aateshshivsharan2884
@aateshshivsharan2884 5 жыл бұрын
Tr vector group ( Dyn11) video
@ElectricalandElectronictech
@ElectricalandElectronictech 5 жыл бұрын
Please click link below for vector group video kzbin.info/www/bejne/kJaxnnqJj7tmfJY
HV Magnetizing Current Test || Transformer Low voltage testing
8:40
Turns Ratio Test (TTR ) of Transformer
6:31
The Engineering Power
Рет қаралды 63 М.
Mom Hack for Cooking Solo with a Little One! 🍳👶
00:15
5-Minute Crafts HOUSE
Рет қаралды 23 МЛН
UFC 310 : Рахмонов VS Мачадо Гэрри
05:00
Setanta Sports UFC
Рет қаралды 1,2 МЛН
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 36 МЛН
6.6 KV/415 V Dry type Transformer Testing ? IR value | Voltage Ratio | Magnetising Current Test |
17:11
MAGNETIZING CURRENT TEST OF TRANSFORMER IN HINDI/TRANSFORMER TESTING
4:29
Transformer SFRA test
4:27
Electrical and Electronic tech
Рет қаралды 24 М.
Voltage Ratio Test || Low voltage testing of transformer ||Hindi
9:41
Mom Hack for Cooking Solo with a Little One! 🍳👶
00:15
5-Minute Crafts HOUSE
Рет қаралды 23 МЛН