Mass Spectrometry Tutorial: How to Tune Your Analytes

  Рет қаралды 104,309

Phenomenex

Phenomenex

Күн бұрын

Why is it important to tune your analytes in house on your mass spectrometer? Danielle Moore, Field Applications Scientist, walks you through the process of tuning your analytes on a SCIEX Triple Quad 4500 mass spectrometer, starting at compound infusion taking you all the way to saving your data.
To read the article visit: phenomenex.blog/2018/01/18/ma...
Any questions, chat with our Technical Experts at www.phenomenex.com/chat.

Пікірлер: 37
@liverpoolfugl
@liverpoolfugl 4 жыл бұрын
" 'Tune' in for the next video". Nice one
@michaelzumpano7318
@michaelzumpano7318 5 жыл бұрын
Well done. Nice workflow and everyday-practical vs exhausting!
@LilGugz
@LilGugz 5 жыл бұрын
This is absolutely fantastic, thankyou so much for putting this together so nicely edited. Even though we use different instrumentation, different samples and analytes and software, the science remains the same. Thanks heaps!
@girishgurbani7395
@girishgurbani7395 4 жыл бұрын
Thank you for explaining basics.
@franciscoleniz6460
@franciscoleniz6460 3 жыл бұрын
Thanks for this great video!
@laboratorylab9214
@laboratorylab9214 3 жыл бұрын
Thanks I just infused Dopamine into my Mass Spec with this video!!!
@dennike2998
@dennike2998 2 жыл бұрын
Cool! Thank you! Very professional! Best regards!
@sonivishalashleshkumar5096
@sonivishalashleshkumar5096 5 жыл бұрын
Very interesting 👌👌
@foc2241
@foc2241 4 жыл бұрын
great Video, could you also Explain the Compund Optimization and FIA? BR
@AbdifetahIOmar-zd6gh
@AbdifetahIOmar-zd6gh 4 жыл бұрын
Nice explanation. could you please show us method validation for LC-MS I want to estimate the concentration of drug in the sample
@asdradiocontrolmodelscafat7533
@asdradiocontrolmodelscafat7533 3 жыл бұрын
thank you
@rajalsanathara6880
@rajalsanathara6880 2 жыл бұрын
Can we optimize the parameters for drug and Internal standard at the same time, using a mix of drug and ISTD at around 100ng/ml..? I really got surprised to see the DP optimization after the CE optimization. Will definitely try this way next time in my lab. Thanks a lot, ma'am. Regards from India 🇮🇳
@prajwalgupta5467
@prajwalgupta5467 2 жыл бұрын
Best video
@MANIKUMAR95950
@MANIKUMAR95950 2 жыл бұрын
Mam there is a caption under your PHENOMENEX logo that is "BREAKING WITH TRADITION" Is there any scientific meaning in that I want to know the meaning of the caption my thought about this caption is "IN LIQUID CHROMATOGRAPHY SEPARATION OF COMPOUNDS BASED ON THE RELATION OF MOLECULES WITH COLUMN MOLECULES ie. RELATIVE AFFINITY" So the compounds present in the sample will break relation with column materials slowly and elute one by one.
@msach4277
@msach4277 2 жыл бұрын
in looking for natural products compounds for specific properties; - even if literature provides possible masses of compounds, there is not enough material to do a tune. What is the best approach for this situation?. Fractions of plant extractions were collected, and would like to analyze these fractions at possible masses found in the literature to start. So do not really know the mass, and volume is approx 50ul or so. Thank you
@smart9924
@smart9924 Жыл бұрын
For every changes you did in the computer sample was being drawn right from the tube? Like it was not used instantly?
@mohammadmufiz1529
@mohammadmufiz1529 5 жыл бұрын
Mam How to identify that Molecules are consist Positive polarity or Negative Polarity??
@SubodhKumar-io3yr
@SubodhKumar-io3yr 2 жыл бұрын
Thank you very much for this usefull video. Declustring potential must be same for all transition.? What is the benifit of multiple channel averaging?
@xtallegacy1183
@xtallegacy1183 2 жыл бұрын
DP will vary from compound to compound. MCA just ensures a good average is obtained and reduces variation in apex of peak
@imsopowerful
@imsopowerful 3 жыл бұрын
Please explain Source gas parameters also
@RAdmJoe
@RAdmJoe Жыл бұрын
When tuning analytes concentration for the API 6500?
@mdlund0
@mdlund0 5 жыл бұрын
What rate are you pumping at (I have a manual syringe pump)? 100 ng/ml @ 5 microliters/min? 20? 200?
@Phenomenex
@Phenomenex 5 жыл бұрын
Hello! Unfortunately, the scientist who starred in that video no longer works in our lab. However, SCIEX does recommend 5-10ul/min. You can find their full manual here sciex.com/x51122. I hope that helps! However, if it doesn't, please reach out to our technical experts at Live Chat at www.phenomenex.com/chat.
@leninjuly8398
@leninjuly8398 5 жыл бұрын
Hi. Could you made other video, explaining how to process using UHPLC HRMS/MS, for give attribution to unknown compounds the formule,retention times, fragment ions, becuase when you run a sample and process the base peak (ms1) you have retention time, but in ms2 you have other rt of the some and not are the same from the chromatogram.I hope you can understand want I can to say. By the way great video:)
@Phenomenex
@Phenomenex 5 жыл бұрын
We are so happy that you found this video helpful! Thank you for that:) I reached out to our partners at SCIEX regarding your question. Here is their reply: "With high res instruments, most people don’t really do tuning in the same way as for QqQ instruments. There are a couple of reasons for this: 1. Usually HR instruments are used for more qualitative work, so the quantitative needs are not as great 2. Generally quant is done from the ToF scan, so fragmentation is not used for quant (although it can be!) If someone wants to do HRMS quant in a way similar to a QqQ, what we call MRM-HR, the tuning process is similar. They need to ramp collision energy to get efficient fragmentation. It is a little different because there will be one CE setting to generate and monitor multiple fragments, not a CE for each MRM. Other parts of the question are a bit confusing, I’m not sure how to interpret." Here’s a video link explaining the scan. sciex.com/community/application-discussions/technology/qtof/fundamentals/multiple-reaction-monitoring-high-resolution-mrm-hr-scan-function Hope this was helpful!
@Phasianidaes
@Phasianidaes 5 ай бұрын
Does anyone know the brand of that column washing machine?
@yusophmanalundong2948
@yusophmanalundong2948 4 жыл бұрын
Hi there! So for unknown compounds, like for natural products. How do run an MS/MS? Thanks...
@AnalystRK
@AnalystRK 5 жыл бұрын
I wanted to learn to how to use it when i was working on my research. My lab attended left me with the machine without any instructions. I ended up jamming all tubing due to solid particles. In the end i had to pay 100$/sample to other lab, to get readings.
@anycolorulik
@anycolorulik 5 жыл бұрын
You must use MS grade solvents only and filter through 0.22um membranes ideally. This avoids particulates. Where is the machine located? People at your lab who know how to run these instruments forget how challenging it can be to become proficient.
@hsdengineering
@hsdengineering 4 жыл бұрын
We offer turbo controller repair for Mass spec systems
@robertlei6112
@robertlei6112 Жыл бұрын
Would you like to sell this used system? I am interesting to buy this used equipment.
@im_so_ronery
@im_so_ronery 4 жыл бұрын
Fentanyl! yummy! Nice demonstration.
@greeleyestateslove
@greeleyestateslove 3 жыл бұрын
Are these things able to be manipulated/hacked to influence the results? I looked at a piece of research that I'm concerned about the origin of the machine....
@bannor216
@bannor216 Жыл бұрын
More like...AB Seinfeld
@marwaabdalla4676
@marwaabdalla4676 2 жыл бұрын
speaks soooo fast
Introduction to Mass Spectrometry
20:04
Knowbee
Рет қаралды 491 М.
50 YouTubers Fight For $1,000,000
41:27
MrBeast
Рет қаралды 198 МЛН
Gym belt !! 😂😂  @kauermtt
00:10
Tibo InShape
Рет қаралды 16 МЛН
Tretyakova Lab • HPLC Mass-Spectrometry Sample Prep
15:28
Natalia Tretyakova
Рет қаралды 5 М.
LC-MS/MS Education Series: Analyte Tuning
16:12
Waters Corporation
Рет қаралды 32 М.
Why Hagoromo Chalk Is So Expensive | So Expensive | Business Insider
16:13
How to use Tune
32:50
Environmental Proteomics Lab Tutorials
Рет қаралды 8 М.
Theory of MALDI-TOF Mass Spectrometry
8:38
ARCC Chem
Рет қаралды 276 М.
Quickly understand various types of LCMS
7:59
Shimadzu Asia Pacific
Рет қаралды 7 М.
Mass Spectrometry
8:20
Bozeman Science
Рет қаралды 487 М.
Quadrupole Ion Trap Mass Spectrometer
15:22
ShortChemistry
Рет қаралды 34 М.
MassHunter GC/MS MRM optimizer
12:39
Agilent Technologies
Рет қаралды 2,9 М.
How to set up MRM method for veterinary drug compounds on LC/MS/MS
6:49
Shimadzu Asia Pacific
Рет қаралды 12 М.
Kumanda İle Bilgisayarı Yönetmek #shorts
0:29
Osman Kabadayı
Рет қаралды 1,8 МЛН
Здесь упор в процессор
18:02
Рома, Просто Рома
Рет қаралды 412 М.
Лазер против камеры смартфона
1:01
NEWTONLABS
Рет қаралды 710 М.
Battery  low 🔋 🪫
0:10
dednahype
Рет қаралды 13 МЛН
Look, this is the 97th generation of the phone?
0:13
Edcers
Рет қаралды 6 МЛН
Какой ноутбук взять для учёбы? #msi #rtx4090 #laptop #юмор #игровой #apple #shorts
0:18
Что делать если в телефон попала вода?
0:17
Лена Тропоцел
Рет қаралды 2,7 МЛН