ME C Electronic Engine Reversal Hydraulics | What happens to Swash Plates during Reversing ?|

  Рет қаралды 12,183

Chief Engineers TeaTimeTalk | Marine Engineering

Chief Engineers TeaTimeTalk | Marine Engineering

Жыл бұрын

In this video you can learn about the Hydraulic Principles behind the Reversal of the Engine. What happens to the Variable Delivery Pumps when #Astern Movement is given ?? | # ME C Engines | #Reversing in Electronic Engine ME C type | Ramesh |RMETCvideos

Пікірлер: 42
@raushankumar3379
@raushankumar3379 Жыл бұрын
THANK U SIR FOR SUCH A INFORMATIVE VIDEO
@user-np4vq8er9c
@user-np4vq8er9c 11 ай бұрын
Thanks a lot sir for your honest efforts behind such informative videos, Keep sharing !!
@dinulmanjitha5854
@dinulmanjitha5854 Жыл бұрын
informative video, thank you sir!
@kappalraja
@kappalraja Жыл бұрын
Much useful video sir !! Please post more videos
@ismaelpabillaran6384
@ismaelpabillaran6384 10 ай бұрын
Thank you sir very informative
@Jahajee_At_Home
@Jahajee_At_Home Жыл бұрын
i am preparing for my class 2 Sir ,.,every single video of your channel is making all the complicated subjects so simple that m sure Ecdt pyarelal after sign off can clear his oral in first attempt :) thanks you sir and waiting for many more such videos to come regarding that question what i could interpret Sir usually 3 pumps are there 1 is control and other 2 are follower,controller swash plate is set to 50% and follower will have B/W 10-100% depending on the RPM of the Engine,. so if the controller pump failed to reverse one of the followers will act as a controller,. and it also has a provision in case of control failure swash plate will be set to 100% ahead direction. and since all pumps are equipped with suc pr sensor if pr is too low for all pumps it ll initiate a Shut Down., ### As you said there are many intelligent people sitting there and coming up with complicated ideas, So to avoid that pump running dry(which dint reverse) they provided v/v 215,. 😊
@kirtikumar8220
@kirtikumar8220 Жыл бұрын
Kay baat hai, pyare Laal, Gangadhar hi shaktimaan hai 😅😅😅😅😅 samje pyarelaal
@Jahajee_At_Home
@Jahajee_At_Home Жыл бұрын
@@kirtikumar8220 Sahi pakde hein...
@wrishabkashyap6102
@wrishabkashyap6102 9 ай бұрын
Thank you sir for your contribution in our learning..pls do post some more videos on ME-C engines,alpha lubricators,feedback signals of cylinder lubrication etc..🙏..
@1612harmish
@1612harmish Жыл бұрын
Thank you very much sir
@srinivasanthayyil4836
@srinivasanthayyil4836 Жыл бұрын
Well explained, dear Ramesh.
@rmetcvideos
@rmetcvideos Жыл бұрын
So nice of you
@rasinthaadhikari
@rasinthaadhikari 5 ай бұрын
Thank you
@manojgk8433
@manojgk8433 Жыл бұрын
Sir make some videos on reflex icu and vcu arrangement
@anandashok4444
@anandashok4444 Жыл бұрын
Always waiting for your videos sir
@arvindkumarsingh1099
@arvindkumarsingh1099 Жыл бұрын
Sir please make vedio on the working of super vit air actuator operated rack how is transmission the air pre to rotate the fuel rack and vit rack at same time
@vikrammgokhale
@vikrammgokhale Жыл бұрын
If reversal of the swash plate does not happen for any one of the pumps, the swash plate could be brought to zero angle (idle). Other pumps will increase their pumping rate to compensate. Also, as already mentioned by Manjit, in case of complete failure, swash plate is set to Ahead ('limp home' mode) 😇
@AmitKumar-ic6dd
@AmitKumar-ic6dd 11 ай бұрын
in case of complete failure , plate is SET TO AHEAD? can you elaborate on that
@vikrammgokhale
@vikrammgokhale 9 ай бұрын
@@AmitKumar-ic6dd in case of emergency (failure), you only need to run the engine in ahead to reach the nearest port...
@rmetcvideos
@rmetcvideos 9 ай бұрын
Ok..lets get this sorted out...in case of failure...of one pump...remember that the signal cannot be received...so the pump cannot be set to zero angle....the faulty pump goes to FULL angle position. . The other pumps compensate...Everything is as normal as possible...No need to use words like LIMP ahead etc🤣can reverse and be as normal ad possible🤣🤣
@Surendhar2002
@Surendhar2002 Жыл бұрын
Sir please make video about jerk type fuel pump working and fuel recirculation upto fuel injector please chief
@ayishak16
@ayishak16 8 ай бұрын
Which book is good for under standing electrical control system of marine engine?
@ojesvisharma1168
@ojesvisharma1168 8 ай бұрын
dear sir, well explained. However to your interesting query in the end of the video - when the engine is astern then as we know during start up or reversing when rpm is low then the hydraulic system is run by the electronic pumps and not by swash pumps ( in the diagram the right side , 2 pumps are located to supply hydraulic oil from sump) swash pumps are isolated during low rpm or reversing at low speed. so we can manage to do astern without any problem but the only thing is we cannot reverse at high rpm. Correct me if I am wrong.....Thanks a ton for the explanation again.
@rmetcvideos
@rmetcvideos 8 ай бұрын
I request you to consider the following points you have said....swash plate pumps are engine driven....so how can you ISOLATE???The question was ..when the swash plate cannot be reversed and also cannot be isolated how a engine can run in full astern direction...if you think on these lines...you will get the correct answer yourself👍
@ojesvisharma1168
@ojesvisharma1168 8 ай бұрын
Okay sir understood. If swash plate angle is not changed and shaft direction is reversed then there will not be any suction from that indivisual pump and other pumps will compensate. Right?
@chiefengineerviraldungrani9581
@chiefengineerviraldungrani9581 6 ай бұрын
On discharge side there is a Check Valve before accumulator connected to A line on which the relief valves are also connected to deliver oil back to Suction side. If I am right, if the swash plates do not reverse, ofcourse we will have alarm in MOP, but the check valves will open and the pump will take suction from B side and deliver to A Side. Thats a Failsafe Mechanism i guess.
@AvinashChaurasia-zn8yj
@AvinashChaurasia-zn8yj Жыл бұрын
@rmetcvideos sir pls explain how the objective of VIT and Super VIT is achieved in ME engine...
@rmetcvideos
@rmetcvideos 10 ай бұрын
All requirements are fed in the software or ECU and CCU which Takes care of these.
@deone786
@deone786 10 ай бұрын
There is a non return valve provided 215 (which will save the pump from running dry by providing oil), in case it doesn't reverse. Pressure compensated by other variable delivery pumps. I guess. Am I right?
@rmetcvideos
@rmetcvideos 3 ай бұрын
you are correct
@sathiskumar3775
@sathiskumar3775 6 ай бұрын
Sir pls explain fuel oil recirculation,secodary injection? What is carbon pipe? Diff between schedule and carbon pipe? Intermediate bearing overhaul? Egb fin tube leak finding ?
@rmetcvideos
@rmetcvideos 23 күн бұрын
:-) all put in queue..Hope I get the time to tackle all these
@abhirajsingh987
@abhirajsingh987 10 ай бұрын
Sir, can you explain more on how when shaft rotation is changed in swash plate pump the suction and discharge CHANGES? According to me the suction and discharge should remain same after changing rotation of the shaft, BECAUSE since the angle is same even after change of rotation and suction of the piston depends on the length of stroke (piston draws liquid in larger length and pushes out as the length of stoke decreases ) which in turn depend on angle of swash plate. The suction and discharge will change only when the angle of the swash plate is changed. Please correct me if I am wrong.
@rmetcvideos
@rmetcvideos 10 ай бұрын
Ha Ha... Imagine a turning gear .shaft turning clockwise--piston goes up..if you turn the shaft anti clockwise..the piston goes down..same logic....
@abhirajsingh987
@abhirajsingh987 10 ай бұрын
@@rmetcvideos yes sir absolutely, but again the suction will only take place in the same region as the angle of the plate has not changed. For example if the suction in the pump was from bottom half of the plate then even after changing the direction of rotation the suction will take place in the bottom half of the plate only. Just that if 1,2,3 piston were in line to take suction and after no.1, no. 2 piston was in line then by changing the rotation again no. 1 piston will take suction and then no. 3 piston and not no. 2. But the suction will be in the same part or from the same port only if the plate angle has not been changed.
@rmetcvideos
@rmetcvideos 10 ай бұрын
If bottom was suction..then it will become discharge when shaft rot changes..for the same angle..Again think hard with the same Turning gear as an analogy.if clockwise rot can make piston go frd ..which is discharge..then anticlockwiase rotation at the same spot will cause piston to retract which is ...suction
@abhirajsingh987
@abhirajsingh987 10 ай бұрын
Yes Sir I agree with bottom half of your reply but, again sir please forgive my audacity to ask you to rethink. If suppose the shaft is rotating clockwise and suction and discharge port are at the bottom and top respectively. Now imagine a clock and piston is to deliver at 12 o clock then after 12 till 6 (bottom ,where suction is) the region is suction build up region as the piston retracts and at 6 o clock suction is complete now the piston starts to push out and build discharge pressure so from 6 to 12 (clockwise direction) is pressure build up region right?! So now at this point if you change the direction of rotation and maintain the SAME angle of plate then the suction and pressure build up region will change i.e now from 12 to 6 ( anticlockwise) it would be suction build up region and from 6 to 12 (anticlockwise) it would pressure build up region but the point or port of delivery would be same i.e 12 for discharge and 6 for suction. These will only change in case the ANGLE of the plate is changed.
@rmetcvideos
@rmetcvideos 3 ай бұрын
@@abhirajsingh987 ..Your logic is correct but I guess smewhere you are missing the point. Maybe bcoz you are --I am simply guessing based on your choice of words like--pressure buid up and suction buid up . there is no such thing called pressure buildup and suction buildup.....It is as simple---as---from 6 to 12 --the entire region is Pipe A and From 12 to 6--entire region is PIpeB ...There is continous discharge or suction of oil all along deoending upon direction of rotation
@JaikumarCNair
@JaikumarCNair Жыл бұрын
Thank you sir
Fundamental Principles of #ELFI |#ELVA |#FIVA |Electronic Engine Combustion components| ME-C|Ramesh
10:22
Chief Engineers TeaTimeTalk | Marine Engineering
Рет қаралды 26 М.
ME-C Electronic Engine Angle encoder|Tacho system working principle |Truth Table| Ramesh Subramanian
12:19
Chief Engineers TeaTimeTalk | Marine Engineering
Рет қаралды 2,9 М.
路飞被小孩吓到了#海贼王#路飞
00:41
路飞与唐舞桐
Рет қаралды 71 МЛН
KINDNESS ALWAYS COME BACK
00:59
dednahype
Рет қаралды 151 МЛН
Incredible magic 🤯✨
00:53
America's Got Talent
Рет қаралды 77 МЛН
DO YOU HAVE FRIENDS LIKE THIS?
00:17
dednahype
Рет қаралды 103 МЛН
How do they do... How to overhaul accumulator onboard ship for ME engines...
19:37
Marine engineering basics by sailor basha
Рет қаралды 9 М.
What is Significance of K Value in Turbocharger??
16:28
Chief Engineers TeaTimeTalk | Marine Engineering
Рет қаралды 30 М.
Me engine HPS AXIAL piston pump OVERHAULING PROCEDURE
18:53
LSB Mariner
Рет қаралды 1,7 М.
Electronically controlled big diesel
6:32
Viktor Knyazyev
Рет қаралды 24 М.
What is #NPSH?? How does NPSH affect #Cavitation??Does NPSH affect Positive displacement Pumps??
23:58
Chief Engineers TeaTimeTalk | Marine Engineering
Рет қаралды 16 М.
Working of Expansion Valve , Defective expansion valve , Liquid return to compressor
16:48
Chief Engineers TeaTimeTalk | Marine Engineering
Рет қаралды 11 М.
ME ENGINE CONTROL SYSTEM
8:23
Sea Legend
Рет қаралды 23 М.
ME Engine Fuel Control and unit Cut out -New Age Online Marine Academy
22:53
New Age Online Marine Academy
Рет қаралды 1,1 М.
Nitrogen  Charging into Accumulator of ME Engine
5:09
Mariner Sizu
Рет қаралды 8 М.
路飞被小孩吓到了#海贼王#路飞
00:41
路飞与唐舞桐
Рет қаралды 71 МЛН