Hello, how is MSA (Measurement System Analysis) conducted on parts where destructive testing is performed? There are controls where we can’t reinspect the part. What kind of method do you apply?
@knowledgefactory-leansixsi2123 Жыл бұрын
You need to use GR&R nested method for destructive testing
@omerzambak4109 Жыл бұрын
Could you tell us briefly, master?@@knowledgefactory-leansixsi2123
@carlosarmelatrigo81102 жыл бұрын
Thank you for the video. It is great! But how can I evaluate if I have a upper spec only (0-30, roundness)?. There is just Bias value and not capability and %Var. Thanks
@knowledgefactory-leansixsi21232 жыл бұрын
Type 1 gage study only applicable for 2-sided spec limit.
@ዘተርቢኖስ2 жыл бұрын
Thank you much !
@volfsonoleg2 жыл бұрын
Hello How the type one gage calculation is done of the tolerance is one sided
@knowledgefactory-leansixsi21232 жыл бұрын
Type 1 gage study is only for 2 sided tolerance
@deanopenn6 ай бұрын
what happens if bias fails but cgk is good in a type 1 study
@knowledgefactory-leansixsi21235 ай бұрын
Type 1 gage study is to evaluate both effect of bias and repeatability.In this case,the measurement variation or repeatability has better performance.You can further perform bias and linearity study to further confirm the accuracy.