Measuring Duct Leakage To Outside

  Рет қаралды 8,127

HVAC School

HVAC School

Күн бұрын

Пікірлер: 15
@coldfinger459sub0
@coldfinger459sub0 Жыл бұрын
Make it so easy to use that even a child can use it. No excuse for the old-timers to say they’re afraid or it’s too complicated. 😂
@carrieresammy
@carrieresammy Жыл бұрын
I’m pretty sure I’ve been to one of his classes here in New Orleans. Great guy
@nappy2720
@nappy2720 Жыл бұрын
That’s always my helper super excited and running to do work. I’m like damn chill for second we will do it all but we have to look at everything first! Love the vids keep it up cuties❤
@timdestasiohvac
@timdestasiohvac Жыл бұрын
Little man knows that blower door better than I do.
@Jon-hx7pe
@Jon-hx7pe Жыл бұрын
how about not putting ductwork in unconditioned attics and crawls in the first place? insulate roof deck or crawlspace walls, close the vents.
@brianmcdermott1718
@brianmcdermott1718 Жыл бұрын
Great video, explains much. Thanks.
@ralphvalente9753
@ralphvalente9753 Жыл бұрын
Interested for feedback from folks who conduct this test. The video noted "outside the thermal envelope" as the lto cfm. If the duct works in the basement, do we mean "leakage in the unconditioned basement" or "leakage" literally outside the home." Also, does anyone open a door or window to connect the basement space to the exterior elemetns.
@kennethdean4349
@kennethdean4349 Жыл бұрын
It appear that two 2-channel manometers are needed, is that right? The test could not be performed with a DG-1000 and a DG-8?
@dustincole2625
@dustincole2625 Жыл бұрын
The 1000 will work, the DG8 will not though
@christopherhughes2482
@christopherhughes2482 Жыл бұрын
The DG-8 in combination with the TEC gauge app will drive the blower door. You will not get a blower door cfm reading, but that is not needed for the DLTO test. You will need a DG-1000 for the DuctBlaster to get a cfm reading.
@bobgreenspun1107
@bobgreenspun1107 Жыл бұрын
How do we know what is an acceptable amount of leakage? For instance, percent of leakage?
@christopherhughes2482
@christopherhughes2482 Жыл бұрын
The best way I think I could answer this would be like this. Most people in a hot humid climate would not dare have a constant volume exhaust fan running with 50 cfm. I think personally keeping it under 25 cfm would be would be a good measure. But this is my opinion based on my own experience in houses in my climate.
@HVASEA
@HVASEA Жыл бұрын
Better break out the mastic!
@billwatcher9321
@billwatcher9321 Жыл бұрын
I have never seen a more convoluted pile of crap than this presentation. IF you seal off EVERY window, ALL bathroom vents, dryer vent, microwave vent, water heater vent, your still going to have some air intrusion. This setup is a great example of "heating contractor overthink sales babble". If your heating contractor suggests you need this done, hire a new contractor. The simple way to check duct leak is seal everything you can, run one of the manometer lines outside, and turn on the furnace . If your ducts are leaking, you will get a negative reading in the house. Simple. BUT, ALL DUCTS LEAK!! So don't fall for the " you need all new duct work right now". The new one's will leak also.
@HVACRTECH-83
@HVACRTECH-83 Жыл бұрын
Problem is the video was way too short to give any kind of valuable info. It is a good test when done correctly.
Discussing Ducts Types and Tips
17:24
HVAC School
Рет қаралды 86 М.
路飞做的坏事被拆穿了 #路飞#海贼王
00:41
路飞与唐舞桐
Рет қаралды 26 МЛН
[BEFORE vs AFTER] Incredibox Sprunki - Freaky Song
00:15
Horror Skunx 2
Рет қаралды 20 МЛН
Beyond Blower Doors: Zonal Pressure Testing
13:38
Home Performance
Рет қаралды 18 М.
Duct Testing Webinar - from The Energy Conservatory (TEC)
55:07
The Energy Conservatory
Рет қаралды 8 М.
Diagnosing Poor Compression
13:53
HVAC School
Рет қаралды 81 М.
Stop Sweaty Ducts, Vents and Systems
23:26
HVAC School
Рет қаралды 271 М.
Measuring duct leakage with a Duct Blaster as required by 2021 IECC - Building Science Series
12:09
TEACH Construction Community Education
Рет қаралды 5 М.
Measuring Static Pressure on an Air Handler for Airflow CFM!
8:08
AC Service Tech LLC
Рет қаралды 267 М.
DIY How To Install A Heat Duct Going To The Floor in Your Basement
10:47
Home RenoVision DIY
Рет қаралды 711 М.
2011 Duct Leakage Testing in Homes
9:34
Southface Institute
Рет қаралды 12 М.
Capacitor and Hard Start Myths Busted
28:41
HVAC School
Рет қаралды 253 М.