Love the overview! Currently doing a protein purification using an AKTA system for a rotation I'm doing so this has been super helpful. If you're reading this now, it means you have already successfully defended--Congratulations!!
@thebumblingbiochemist Жыл бұрын
Great to hear. Thank you and best of luck with your purificcations!
@nicholaskampa29932 жыл бұрын
Very good and informative! I'm still learning how to use the machine, but videos like this help me figure it out
@thebumblingbiochemist2 жыл бұрын
So happy I could help! Have fun purifying!
@sakitlaatigue2 жыл бұрын
Thank you for the elaborate information on FPLC AKTA. Currently I'm using a much simpler FPLC which is AKTAprime plus. However, the principle is still the same and so many tips and tricks I've learnt from your video.
@thebumblingbiochemist2 жыл бұрын
Happy I could help! Good luck with your purifications!
@JackieLiu0406 Жыл бұрын
Not one, not two...but four AKTA. I am amazed. 👍
@thebumblingbiochemist Жыл бұрын
HHMI structural biology lab - definitely was spoiled!
@aruyukimayu11992 жыл бұрын
I envy you! I am trying to get a column selection valve V9-Cm for 3 columns and you have the one for up to 5 columns (V9-C) :)
@thebumblingbiochemist2 жыл бұрын
I miss it!
@tmanbravo3 жыл бұрын
Those Aktas are sweet! So cool CSH has a Titan Krios!
@thebumblingbiochemist3 жыл бұрын
:)
@שגיתזיוספר4 ай бұрын
Great explanation! Loved it, thank you!
@thebumblingbiochemist4 ай бұрын
Glad it was helpful!
@056vatsalapandey32 ай бұрын
What college did you record this
@thebumblingbiochemist2 ай бұрын
Cold Spring Harbor Laboratory
@halilojaallways72042 жыл бұрын
You Rock!! Very useful Information
@thebumblingbiochemist2 жыл бұрын
Thank you! So glad it was helpful!
@naba0993 жыл бұрын
I am having this problem.... When I take the sample by hamilton syringe, sample tends to leak without pushing the plunger. The plunger automatically goes downwards and leaks out my sample. So I have to put the syringe always at vertical position.. which is quite problematic. Do you face this issue too? Also please make a video on how to set the methods. I am basically a molecular biologist but as a part of the project, need to confirm interaction of some proteins.
@thebumblingbiochemist3 жыл бұрын
Hi. Could it be you're pulling to quickly maybe? Sounds like you have pressure build-up in the syringe. Sorry but the methods really vary for different things so I'm not sure I can help with that but good luck!
@ishakgun2 жыл бұрын
Probably piston of the syringe is a little bit heavy. There are air tight syringes of Hamilton which is suitable for gas sample. You might ise these syringes
@gopalra9040 Жыл бұрын
great
@SteSews2 жыл бұрын
Hello, I do have a probleme with my Akta system, the UV sensor doesn't work, I can't obtain a graph with UV variation. I do see the UV variation in the little screen wich is on the machine, but there is nothing on the graph so it's very hard to know where my samples are...Does anyone have an idea on how I can fix this please let me know ! thanks
@thebumblingbiochemist2 жыл бұрын
I don't know sorry! Did you try restarting the machine? and software
@SteSews2 жыл бұрын
@@thebumblingbiochemist thank you for your answer :) ! I did try to restart everything..but nothing change unfortunately
@thebumblingbiochemist2 жыл бұрын
@@SteSews Really sorry to hear that. They have really great customer support though so hope they can help!
@shm6897 Жыл бұрын
The UV modules on these instruments are notoriously prone to failure over time. Usually it’s related to a breaking of the beampath or a lamp dying. They sadly are also $$$$