I discovered a new way to do this while watching your video 😊
@TimWilborne2 жыл бұрын
That's great!
@gbengaoyede28772 жыл бұрын
@@TimWilborne pls sir, i have been using ccw for a while, now i need to communicate with another software (excel or scada) and i need the opc/dde function, i just discovered that rslinx classic lite doesn't support this function, i don't have plc, i have been using the simulator only, pls is there anyway to use the opc/dde function without real plc?
@JohnSmith-je8uu3 жыл бұрын
Awesome video! The particular case could also be done on the VFD (just in case you don't have a PLC to use). I had a case where I needed to regulate water level, so I programmed an input to be 20 percent faster than my incoming pump when my water level sensor was false, and 20 percent slower when the water level sensor was true. I love the logic on this project though, super cool!! Thanks Tim for doing these videos.
@TimWilborne3 жыл бұрын
You are welcome John!
@scottmcbride55143 жыл бұрын
Great Video, helped much!
@TimWilborne3 жыл бұрын
Glad to hear it Scott.
@sunilgiri77923 жыл бұрын
Thanks sir ...... From INDIA ❤️
@TimWilborne3 жыл бұрын
You are welcome!
@nematalla13 жыл бұрын
Can we have a video on AB safety relays ?
@TimWilborne3 жыл бұрын
Check out this lesson series on the CR30. twcontrols.com/safety-plc-lessons
@alnaseri36223 жыл бұрын
HI Tim. quick question. is there any way i can get 4-20mA out of Micro820? I'm using 2080-OF2 plug-in module, but the output is 0-65533, tried to scale it but no different. as you know the data type on this module is UINT so I'm not sure if I'm doing something wrong here. Thanks in advance!.
@TimWilborne3 жыл бұрын
Yes, I don't have a video on it but you just need to do some scaling. What is the full range of the module, that is what will equal 0-65533.
@WEENRJ3 жыл бұрын
i like your videos , but i would like to suggest if you could make a tutorial step by step for rslogix 5000 for beginner . thanks
@TimWilborne3 жыл бұрын
We have a whole lesson series on Studio 5000, you can find all of our lesson series at the twcontrols.com/plc-lessons
@Time-Trvlr3 жыл бұрын
with two discrete inputs you could have many step speeds utilizing a step then wait logic and even have a full on 100% with a ramp speed of your choice.
@TimWilborne3 жыл бұрын
Yes you could Joel. Overall I wouldn't be a fan of this without some feedback of the actual speed. We did it in this HMI video though the drive speed was over a network connection. twcontrols.com/lessons/reading-and-writing-analog-values-to-an-allen-bradley-panelview-800-hmi-touchscreen