Midnite Solar 600v Solar Surge Protector Install

  Рет қаралды 7,062

Land to House

Land to House

Жыл бұрын

Installing the Midnite Solar [SPD] Surge Protection Device is simple and easy. This is installed to clamp down high voltage from a lightening strike or power surge so that your solar equipment does not become damaged. Match the black wire with the negative of your solar input and the red wire with the positive of the solar input and lastly connect the green wire to earth ground.
This Surge Protector is available on Amazon here:
amzn.to/3HpkBtH
Ram Pumps available on AMAZON
amzn.to/2EWrQHN
Also available on Land To House Website:
www.landtohouse.com/rampumpsales
Help Support land To House by Paypal:
paypal.me/landtohouse
Send Mail to Land To House:
Land To House llc
P.O. Box 323
Micaville, NC 28755
See whats coming up before it hits KZbin on my Facebook Page:
/ landtohouse
Land To House is a participant in the Amazon Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to amazon.com

Пікірлер: 37
@hayderalsalman7984
@hayderalsalman7984 Жыл бұрын
Great work. I think that the boltless should be used when connecting the wires inside the circuit breaker, and not relying on the screw, so that there is no looseness in the future.
@samajier2566
@samajier2566 Жыл бұрын
Great work
@tekki2060
@tekki2060 10 ай бұрын
I have one of these protecting my Midnite Solar controller. Their products are excellent and I'd recommend them to anyone that is seriously considering solar. This device is very easy to install on their controllers.
@LandtoHouse
@LandtoHouse 10 ай бұрын
You are right! Install is very simple.
@jllaine
@jllaine Жыл бұрын
That's a really good idea, surge suppression. It contains 3 Metal Oxide Varistors (MOVs), one between red and ground, one between black and ground, one between red and black. If any pair goes over 600v (ac or dc) the excess is shunted through the MOV to try to keep it down to 600v. If your black (negative) wire has an earth ground, they yes all surges will go to ground.
@LandtoHouse
@LandtoHouse Жыл бұрын
According to midnight solar these are required on PV panels going into a house. Definitely don't want any kind of surges finding their way to the electronics.
@Paul_______
@Paul_______ 11 ай бұрын
I think I have mine wired the same way you do but I wasn't sure if I was right. I have it on the top of my breaker along with the pv feed to the breaker. I wasn't sure which side of the breaker it should go on
@Urge38
@Urge38 3 ай бұрын
can them tiny wires from the spd really cope with a lightning strike. ????
@tjmooney4181
@tjmooney4181 5 ай бұрын
Curious why the spd is wired on the opposite side of the breaker from the pv incoming? Seems like the surge would trip the breaker and the excess power would never make it to the spd 🤔
@DavidHalko
@DavidHalko Жыл бұрын
Is it code to tie that many ground wires together, with a nut? I would think you are hitting the number of wires where a ground bar is needed? Also, is it code to insert 2 wires into a single slot on that circuit breaker? (Some breakers say you can do it, others say no…) I would think you needed to pigtail it?
@LandtoHouse
@LandtoHouse Жыл бұрын
A ground bus bar has now been installed. Much better. As for connecting the spd to the same location as the inverter, it has done fine. But a separate bar would work well.
@gssrustenburg
@gssrustenburg 8 ай бұрын
Great instructional video. One must also bear in mind matching the spd close to the max input of inverter. A 600v spd will not provide protection to inverter with much lower, max input voltage. 600v can still destroy an inverter with max 145v input.
@gssrustenburg
@gssrustenburg 8 ай бұрын
Same goes for the ac side, a 1000v spd will not protect equipment rated for 110v or 220v.
@MichaelCoughlanmusic
@MichaelCoughlanmusic 8 ай бұрын
Will this protect against an EMP event?
@LandtoHouse
@LandtoHouse 8 ай бұрын
No this is simply for high voltage surge from lightning strike or other surge. not for EMP.
@cowboymcq6711
@cowboymcq6711 Жыл бұрын
Where did you get that breaker jumper ? I’ve been looking to do the same thing
@LandtoHouse
@LandtoHouse Жыл бұрын
I am developing them. Working on the CNC to make this a product. Not ready yet but hopefully soon.
@cowboymcq6711
@cowboymcq6711 Жыл бұрын
@@LandtoHouse will be a big help because you can’t find big enough breakers for the solar. I’m running a 2 pole 125 amp for my EG4 6000ex and it’s right close to barely being enough
@LandtoHouse
@LandtoHouse Жыл бұрын
Yes! I thought the same. Otherwise how do you connect multiple breakers! My system needs 500v so had to use the double breaker as well.
@Oneonetwotwos
@Oneonetwotwos Жыл бұрын
Copper bus bars are an off the shelf item for electrical contractors, paralleling up 2 breakers works until 1 pole fails then the 2 pole is left to carry 100% of the FLC. there are a few manufactures of 2 pole breakers up to 250 Amp 1000vdc. I use Beny , maybe consider sizing up your enclosures to suit the application, You need to use Glands on the DC single double insulated to avoid cable movement under high current fault conditions. Ferrules should be used for all flexible conductors to avoid strain from the terminal screws.
@USA-GreedyMenOfNoIntegrity
@USA-GreedyMenOfNoIntegrity 11 ай бұрын
600 VDC is the max nominal voltage of the pv system, not as you suggested. “Clamping” doesn’t begin until 780VDC. 1800VDC is your average voltage limit…three times what you stated. I have 13 MNS SPD’s on my system.
@LandtoHouse
@LandtoHouse 11 ай бұрын
Thank you for the clarification! I will mention that on my next install for the last solar array on the property... well for now. I have another 2kw system planned.
@johnclemont7801
@johnclemont7801 Жыл бұрын
Whole Home Battery? Did I miss a review? What is it?
@LandtoHouse
@LandtoHouse Жыл бұрын
Its coming up soon! Just sitting down to edit this video. Vestwoods 14.336kwh battery with 8kw inverter.
@joshg1244
@joshg1244 Жыл бұрын
Looking forward to the details!
@chichomancho1791
@chichomancho1791 Жыл бұрын
The cables are too weak to use for surge-protector.
@41546able
@41546able Жыл бұрын
What is the difference between the 300 and 600
@LandtoHouse
@LandtoHouse Жыл бұрын
The clamp voltage. Because my solar is 450v the 300v would not work.
@todamnbad
@todamnbad Жыл бұрын
I'm confused on where you put the SPD, is that your PV disconnect?
@LandtoHouse
@LandtoHouse Жыл бұрын
Yes on the pv disconnect breaker.
@todamnbad
@todamnbad Жыл бұрын
@Land to House you have a red and black? Sorry for the questions but I'm confused and trying to also install one
@LandtoHouse
@LandtoHouse Жыл бұрын
@@todamnbad i have a double pole single throw breaker that cuts both the red and black wires on the PV. This allows me to install the spd here.
@todamnbad
@todamnbad Жыл бұрын
@Land to House I was thinking your pv wires were black, so your pv in goes to the top of the breaker and the bottom is the output to the MPPT?
@LandtoHouse
@LandtoHouse Жыл бұрын
The red and black pv wire comes in to the bottom of the breaker and leaves the top towards the mppt.
@lionelcox9119
@lionelcox9119 Жыл бұрын
Come guys you all are close ,put the whole system indoor use two drums, one of which you turn into a Drum pump ,,^ iit must above the other drum which would have both the ram pump and generator above it,, way it should work,, Drum pump should pump the water from the lower drum to the ram pump to generator, having all the water falling back into the lower drum,,,. Or am I just crazy,,. Please fill me in with how it goes,,,.
@user-lo9fe9pt6f
@user-lo9fe9pt6f Жыл бұрын
What is the price for it
@LandtoHouse
@LandtoHouse Жыл бұрын
This one on amazon was $90.
MidNite Solar's Surge Protection Comparison Test
9:28
MidNite Solar Inc.
Рет қаралды 19 М.
MidNite Solar's Secrets to DC Breakers
5:36
MidNite Solar Inc.
Рет қаралды 61 М.
ПРОВЕРИЛ АРБУЗЫ #shorts
00:34
Паша Осадчий
Рет қаралды 1,9 МЛН
HOW DID HE WIN? 😱
00:33
Topper Guild
Рет қаралды 45 МЛН
DEFINITELY NOT HAPPENING ON MY WATCH! 😒
00:12
Laro Benz
Рет қаралды 51 МЛН
3kw solar panels installation and fitting for giud||solar panels install
16:37
Midnite Solar Surge Protection Device SPD [ Full Install ]
6:34
Tools Tech And Gear
Рет қаралды 4,8 М.
MidNite Solar - Introduction to the Surge Protection Device
9:38
MidNite Solar Inc.
Рет қаралды 26 М.
DIY Home Solar System Lightning Protection EMP Shield
18:26
Projects With Everyday Dave
Рет қаралды 33 М.
Grounding & Bonding For Solar Inverters: Part 1: Basics
12:38
Reel Clear Media
Рет қаралды 13 М.
Guy Installs 3KW of Solar in 11 Minutes
11:24
Land to House
Рет қаралды 20 М.