They need the mother of all attic fans to make that setup work.
@uxwbill5 ай бұрын
I once worked on a similar setup...a much smaller old building subdivided into offices and apartments, with mostly abandoned 1960s or early 70s condensing units on the roof, and the new ones in an otherwise disused upstairs room. They had a repurposed wall mounted furnace blower controlled with a temperature and humidity control. This blew the hot air directly outside. It all "worked" until the control burned up. A few weeks later, the motor bearings went. I didn't get there until hours after the condensing units finally tapped out. The heat in that room was still off the chart. The building owner only wanted a repair. It was then that I discovered the failed motor was paired with the wrong (too small) capacitor. It's a wonder the thing worked as long as it did!
@peterfairlie22965 ай бұрын
That's the Adams family house. Only thing missing were the vampire Bats attacking you in the attic and Uncle Fester coming out of the wall.
@brnmcc015 ай бұрын
And Lurch coming to the door when you arrive, "You rang??"
@therealscottyp5 ай бұрын
Would love to see that boiler setup if you head back there! I always enjoy your content!
@danielboulton16925 ай бұрын
This is super common in my area, only on Heritage buildings. They dont want unsightly condensors on the ground near the building, so theyre either in the attic, or the basement. Seen both. 😆
@deanmartin19665 ай бұрын
The only thing missing is a dryer vent next to those condensers. At least they spaced them far enough apart. Lol.
@karlschoen72975 ай бұрын
I'm amazed the compressors haven't cooked yet
@brnmcc015 ай бұрын
Well, the run caps were getting weak and that contactor looked burnt, so they were getting there! The thing that kept the compressor alive is short well insulated lineset, and not run low on charge. Compressors in these type of units get most of their motor cooling from the return gas temperature, which is why it says in the book no return gas temp over 65 degrees. As long as there's sufficient gas flow and the return gas is 65 or less, the motor will survive. On the other hand, pushing against that massive head pressure will eventually take it's toll. If those were 410A units, I'd be shocked if the head pressure was under 450 psi.
@brnmcc015 ай бұрын
A house that size would normally have like a boiler room with chillers, and hot/cold water lines going to small air handlers throughout the space with supplemental radiant heat/in floor heating as needed. It's a lot simpler and cheaper to pump chilled water to where you need the cooling versus spending energy on moving cold air long distances and trying to install ducts in a 90 year old house. They got hot water up to those fan coil units, no reason couldn't also have a cold water coil too. And then have a small cooling tower out behind a wall somewhere hidden out back.
@bruceorourke54325 ай бұрын
Salem some exhaust fans with temperature controls should help solve the problem as long as you got some good fresh air coming in
@JJ-Toreddie5 ай бұрын
That old capacitor would have lasted longer than the new one 😂😂
@DanT2715 ай бұрын
I'm not an HVAC technician but I think that wasn't the installers brightest idea Wouldn't a water source heat pump be the better option in that scenario?
@DabblelyDiddly5 ай бұрын
they got water to the outside they can get the lineset outside. none of this setup makes any sense
@DanT2715 ай бұрын
@@DabblelyDiddly oops, I never thought of that. It would sure be cheaper than a water source heat t pump
@Sctronic2095 ай бұрын
Looks like Radon fan dumping in the attic.
@phaedrus26335 ай бұрын
Ol' Michigan does get hot, and particularly humid, in the summer. And stays like that until the wee hours of the morning. Here, in CA, it cools off quickly as soon as the sun goes down you can open windows and cool down your house.
@brnmcc015 ай бұрын
If converting that system to some sort of water cooled condensing units won't work, because maybe they have a well on the property or the aesthetics of a remote located cooling tower won't work, then what you can do is get a couple more cheap air handlers, and use those for condensers, and install supply/return ducts to get a proper outside airflow to your the air handler coils. Buying a couple of cheap 4 ton like Goodman air handlers with no heat kits would be 1000's of dollars cheaper than going to a split water source heat pump system. It looks like there's plenty of existing openings in that roof to make it work, like that existing roof powered exhaust fan needs to go. That's creating negative static pressure in the attic, and they'll be losing conditioned air from leaking up into that attic. If those are 2 3 ton condensing units, then you'll need like 2 4 ton air handlers, and then just bypass or delete the condenser fan and coil from those existing units. You could even put some kind of low ambient controller on those too, and control the blower speed based on head pressure or whatever. Will need some kind of air filter so those coils won't get plugged with dirt though too, but those existing coils looked pretty decent. Another big benefit of using some air handlers is they'll have a drain, washing out those existing condensing units like that would be an absolute nightmare and risk ruining probably beautiful plasterwork on the ceiling below. Some of those houses have huge plaster designs and crown moldings around all the light fixtures etc, and water damage to that stuff is a massive nightmare.
@LeoLoder5 ай бұрын
These are the types of days when naturally the unit is one of the further away from the access. And you say to yourself when you're sweating buckets....why the hell did I pick this trade. Nice work!
@Jon-hx7pe5 ай бұрын
Keep in mind that the relationship between sq ft and required capacity is not linear - bigger houses need less cooling per sq ft just b/c of perimeter/exterior surface area vs floor area. 4 to 6 ton still sounds lite - i would think 8 to 10 tons.
@mikenovak94255 ай бұрын
Those comfortmakers will have a hard time making comfort 😂
@hkhsm3595 ай бұрын
Nice job.! Thanks for sharing this great HVAC life content.
@watermanone75675 ай бұрын
I had a customer that the condenser was in the attic and she did not want to believe me that it was way to hot for it to be up there. She had two more opinions that tried to come back to me to fix the issue. I declined the job as she only wanted to put a small attic fan in the soffit.
@theairconditioningguy5 ай бұрын
What in tarnation?!
@davidbuchanan19385 ай бұрын
Never seen that before
@throttlebottle59065 ай бұрын
what in the!?!?!? 🤯 now I have seen it all.
@MichiganCustomCraftworksLLC2 ай бұрын
Hey Joe, is that even code anymore? Fire hazard? 🔥
@Yawwee5 ай бұрын
WOW - that sure is a huge house !!!!! The attic was endless !!! They sure do need attic exhaust fans in them attic openings !!! It makes for a good sauna during the day time. You do look a little thinner leaving then when you arrived !!!!! Want to see some video on your return trip. You certainly are the service man for this job !!!!!!!!
@brnmcc015 ай бұрын
Better off to spray foam that roof deck with soft open cell foam, and get rid of all that nasty fiberglass and mouse turds, and completely seal and encapsulate that attic and turn it into at least semi-conditioned space. That whole attic is wasting a giant ton of energy, and heating and cooling a 12000+ sq ft house is not cheap. Nothing wrong with radiant heat, it adds to the authentic old school look of the interior, but a lot can be done with high efficiency boilers with smart controls to change the heat source temperature based on the heating load on the building etc.
@SonicOrbStudios5 ай бұрын
I need his accountant Job lol
@stevef63925 ай бұрын
Gee, think I feel a song coming on! 🎵 Its gettin hot in here, so hot! Those condensers are gettin so hot, they wanna take their clothes off! Mix a little bit a ah, ah With a little bit a ah, ah🎵
@DabblelyDiddly5 ай бұрын
I'd really love to see how they got those condensers up there... I bet that was quite the shit show
@kens.37295 ай бұрын
LMAO 😬👍
@mattthomas12175 ай бұрын
That's what I was thinking lmao
@JamesBrown-db9pk5 ай бұрын
NOT SAFE 2 B UP THERE 2 HOT GET OUT
@aspinthereddragon93025 ай бұрын
what kind of setup is that? why are ducts so small and why tf are condensers in the attic??
@williamserver43325 ай бұрын
Its called a unico system which is a high velocity system. The ducts are much smaller but you have to run a lot more of them. Mostly used in older homes where traditional ductwork is too big.
@aspinthereddragon93025 ай бұрын
@@williamserver4332 I think a ductless split system would be way better then this, or just window AC's, because these cendensors are just going to run 24/7
@throttlebottle59065 ай бұрын
@@aspinthereddragon9302 they clearly "have more money than brains" and do not want to see anything on the walls, have lines ran down the building inside our out, ugly condensers, which of course means no window-rattlers either.
@aspinthereddragon93025 ай бұрын
@@throttlebottle5906 for something like this I would recommend mitsubishi slim ducting or multi zone mini split systems
@travlincub3215 ай бұрын
Uhhhhh i get astetics and all but thats just ridiculous
@kens.37295 ай бұрын
Wouldn’t you Like 🤪 to Meet the Genius who Thought 🤪 it was a Good Idea to Install two (2) Condensers in an Extremely Hot Attic with Very Limited Ventilation ?🤪
@DabblelyDiddly5 ай бұрын
who how and why........
@sanman55015 ай бұрын
Who would do this walkaway
@buffydog215 ай бұрын
Why would he put the condensers inside the house? That's like putting a furnace outside to heat the inside of your house. Did he not want to spend the extra money to run the freon lines outside. Or it's like, having your furnace heat coming outside. He's chasing his own tail and wasting money. Maybe he didn't want to mess with the aesthetics of the outside of the house with air conditioning compressor units? After I see the aesthetics of the house and scenery, I can see, that he wants to keep it as a woodsy look with no modern-day equipment outside.
@brnmcc015 ай бұрын
People put furnaces outside all the time. It works if done properly. The key word there is "properly". People use wood fired outdoor boilers all the time. And millions of commericial buildings and even some houses use gas fired package units on the roof, or sitting outside on a pad with side discharge ducts. Again, not an issue proper internally insulated well sealed duct system is used and sized according to Manual D, and equipment selection made with S, and sized to Manual J. Rules of thumb don't work on huge old houses like this.
@andygulick60855 ай бұрын
WOW
@kens.37295 ай бұрын
One (1) Question, how were you able Stand the Hot 🥵 Temps in that Attic and Not Pass Out. Very Dangerous Conditions in that Ridiculous Attic. Thanks! 🤪👎
@brnmcc015 ай бұрын
Do only short visits, and pop a cover off of an air handler to get some cold air blowing on you is how I've survived attic visits. Take frequent breaks, and drink water during a break as soon as I start feeling dizzy.
@JamesBrown-db9pk5 ай бұрын
THATS THE GUY U NEED 2 ASK 4 MONEY 4 YOUR BILLS AND KID
@greendryerlint5 ай бұрын
Wow, that may be the stupidest setup I've ever seen. There had to be a better way to set that up. How would you go about cleaning that coil?
@weiqianghuang60295 ай бұрын
Can I go work with you every Sunday I want learning the hvac skills please massage me please
@weiqianghuang60295 ай бұрын
It’s for sure I living in Michigan too,may be I can help you to carry things or camera