I'm a pipefitter/welder 20 years in the field in Florida, n I'm keeping right up with this stuff,
@abdulhalimmahmood67343 жыл бұрын
API574 Table 1 provide the Outside diameter. Table 3 provide the permissible tolerances. Hence, for SA106 provide the +-12.5% as manufacturing tolerance.
@bhushanjadhav29194 жыл бұрын
I wish my collage tough us this . Awesome teaching .
@ajaygorla22844 жыл бұрын
Very good presentation. Covered the require concepts.
@BalakumaranJ Жыл бұрын
Thanks for this wonderful lecture Just wanted to clarify/get clarified on your explanation of Weld Joint Strength Reduction Factor You mentioned that in CS pipes if temperature is greater than 900deg F, we have to refer to the table. But in general, all CS pipes have W=1.
@i4i-academy Жыл бұрын
That is correct
@nurmohammad-learninghub33904 жыл бұрын
Sir, tm=0.248/0.875, this 0.875 comes from where please can explain here- how you find 0.875? Thanks in advance.
@kunleade-oni21973 жыл бұрын
He mentioned the 12.5% tolerance from b31.3.
@kevinsakitey54283 жыл бұрын
NPS 8, (XXX Strong) = 0.875. from Normal wall thickness table API RP 574 Pipe Schedule table
@tajaulamaofficial30123 жыл бұрын
Pipe tolerance is 12.5%, which 0.125. Then, just minus it with, 1.0 (100%) -0.125 (12.5%) = 0.875 (87.5%)
@suyashhogade69994 ай бұрын
Why it is divided and not done like (tn = tm + 12.5% of tm) i.e. 1.125×tm= 0.279?
@eddysameducators Жыл бұрын
Great explanation well understood
@i4i-academy Жыл бұрын
Glad it was helpful!
@santoshingale89792 жыл бұрын
Thanks a lot sir, it's very helpful
@sachinhumtum6 ай бұрын
What weldung reduction factor in case of wrlded pipe A358 304H
@dineshbabu25672 жыл бұрын
Sir the temperature range is given upto 1500 Fahrenheit only for SS materials. What should i do if I need to calculate the pipe thickness for SS material which has the operating temperature 1000deg Celsius?
@RyanMcWhole3 жыл бұрын
What is the joint quality factor for welded pipes? 26" and above?
@Warriorufa3 жыл бұрын
Hello! Which of the nozzle wall thickness values is the rejection value? Calculated minimum wall thickness from int/ext pressure, or min wall thickness from UG-45? ta or tb?
@omedlpg3 жыл бұрын
ASME II PART A1 16.3; Thickness - The minimum wall thickness at any point shall not be more than 12.5% under the specifie wall thickness.
@amirb3083 Жыл бұрын
Correct, Or in other word: the thickness of the standard pipe after manufacturing tolerances has 87.5% or 0.875 of it's nominal thickness for sure, so you can count od .875 of thickness.
@tayyabali92124 жыл бұрын
plz upload some more videos adout b31.3 calculations
@ferasesmaeel47143 жыл бұрын
dear inspection 4 industry thank lots for your efforts can I ask you a question? when I do piping wall thickness calculation with all B31.3 (last edition) code considerations I get some answers without identified schedule numbers according to B 36.10 M-1015 As example :24" with 20.62 mm wall thickness as you note this wall thickness didn't have a schedule number while (schedule 40 for 17.48 mm ) and (schedule 60 for 24.61 mm) can you kindly provide me with your answer and advise
@e.saravanansaran19854 жыл бұрын
Gratings Good presentation sir, t kindly send external pressure calculation presentation video.
@kevinsakitey54283 жыл бұрын
Table A-1 Basic allowable stresses in tension for metals. shows 750-degree is (17300) but in the solution above its stated 13900. Please any explanation to that. thanks