MOST USEFUL/IMPORTANT PARAMETERS : ABB ACS 800 VFD

  Рет қаралды 16,615

bishant kumar

bishant kumar

Күн бұрын

MOST USEFUL/IMPORTANT PARAMETERS : ABB ACS 800 VFD

Пікірлер: 87
@amirhussain4637
@amirhussain4637 7 ай бұрын
Kys bt hai bht acha Tariqa r zbrdast Information maza agya
@bishantkumar12589
@bishantkumar12589 7 ай бұрын
Sukriya sir. Please share with your electrical team 🙏
@pramodsahoo1375
@pramodsahoo1375 3 жыл бұрын
Thank you sir, valuable video. But it's a standard software. Plz make a video hoist software.
@amitpagare5946
@amitpagare5946 3 жыл бұрын
Very informative video 🙏🙏👍
@bishantkumar12589
@bishantkumar12589 3 жыл бұрын
Thank you sir 😊 please support the channel... subscribe and share
@technogamergaming1504
@technogamergaming1504 Жыл бұрын
thanks sir for your for making this vidio please make more this type of full vidio on all vfd and mainly yaskawa and danfoss and delta
@bishantkumar12589
@bishantkumar12589 Жыл бұрын
Okay sir.
@sujitsutar4953
@sujitsutar4953 3 жыл бұрын
Thank you sir....🙏🙏
@arunvishwakarma6812
@arunvishwakarma6812 3 жыл бұрын
Sir plz make a video over dtc mode selection and parameters for dtc mode and how to set range of torque
@bishantkumar12589
@bishantkumar12589 3 жыл бұрын
Sir. As per my knowledge, DTC mode is selected only for applications where high precision of movement is needed. For general,scalar mode is okay. Torque is generally unchanged : -300 to +300 is set
@arunvishwakarma6812
@arunvishwakarma6812 3 жыл бұрын
@@bishantkumar12589 okay sir
@rakesh78070
@rakesh78070 3 жыл бұрын
Thank you Sir...I have one doubt how can i clear maximum fan running hours alarm in ABB ACS 800 VFD
@bishantkumar12589
@bishantkumar12589 3 жыл бұрын
kzbin.info/www/bejne/laHcdKh8at9_fNE
@bishantkumar12589
@bishantkumar12589 3 жыл бұрын
Sir. Please check this LINK ... Pl support the channel... subscribe and share
@rakesh78070
@rakesh78070 3 жыл бұрын
@@bishantkumar12589 Thank you Sir....Subscribed...expect more useful videos
@rajeshyedla3326
@rajeshyedla3326 2 жыл бұрын
Thanks
@ranjangupta5700
@ranjangupta5700 2 жыл бұрын
Sir How to set minimum speed that motor will achieve while starting VFD? and sir what is "1- 89.1%" written in the Top of the digital display?
@bishantkumar12589
@bishantkumar12589 2 жыл бұрын
In parameter 11.04 - set the minimum speed which is required, in there video, it's 0, set as required. & On HMI - 1-89.1% is the reference given by control room to run the VFD (out of 100%)
@ranjangupta5700
@ranjangupta5700 2 жыл бұрын
Thank You Sir! I have one more doubt ,What is meant by Jog speed or when we select Jog speed ?
@akhtarshamim2424
@akhtarshamim2424 Жыл бұрын
Love brother
@bishantkumar12589
@bishantkumar12589 Жыл бұрын
👍
@kevin00861
@kevin00861 Жыл бұрын
Dear Sir, Thank you for your video, I kindly need your help, ABB VFD ACS800-01 , some parameter groups do not show up on the local control panel, the only parameter groups that show are 10, 11, 14, 16, 33 the rest do not show. And also the language selection which should be in group 99; it shows in group 33. I could not find any related setting in the drive manual. any clarification, please
@bishantkumar12589
@bishantkumar12589 Жыл бұрын
You must speak with your ABB service engineer. I am also a field engineer, do not know that much in details. If you still need help I can talk to my ABB service engineer but he is chargeable.
@kevin00861
@kevin00861 Жыл бұрын
@@bishantkumar12589 Yes please, I would be so grateful to you Sir would you share your email or WhatsApp number so i can send you the photos and video
@veereshh1824
@veereshh1824 8 ай бұрын
Dear Sir Drive is tripping on overcurrent fault. But actually no overcurrent, taking Normal current while tripping. Please suggest how to solve the problem.
@bishantkumar12589
@bishantkumar12589 8 ай бұрын
Put the drive to scalar mode and check veeresh Anna
@veereshh1824
@veereshh1824 8 ай бұрын
@@bishantkumar12589 Sir it is not Tripping immediately, it is tripping after sometime.
@veereshh1824
@veereshh1824 8 ай бұрын
How to set control Board temperature and it can Bypassed?
@sanjaykesarkar1918
@sanjaykesarkar1918 Жыл бұрын
Why can't given information about ID run. Its important Parameter.
@bishantkumar12589
@bishantkumar12589 Жыл бұрын
It's big topic sir and there's a complete separate video on it. U may check my ABB playlist for all the details
@nikhilmishra3951
@nikhilmishra3951 Жыл бұрын
Sir acs800 vfd me encoder ko bypass kaise kre
@bishantkumar12589
@bishantkumar12589 Жыл бұрын
50.06 set internal estimate
@pramodsahoo1375
@pramodsahoo1375 3 жыл бұрын
As I know, torque is different in star and delta but why motor always connect in delta for vfd control.
@bishantkumar12589
@bishantkumar12589 3 жыл бұрын
Sir. It's very thoughtful observation u did. Great. As of now I don't know surely y its VFD motor r connected in delta but... In my observation, I have seen only HT motors (6.6kv) are connected in Star , they need very high torque while starting of equipment. Else all LT motors are connected in delta. Still, I'll check for better results and revert ASAP sir. TQ
@praveenkumar-uu6ht
@praveenkumar-uu6ht 3 жыл бұрын
How to ser drive parameter using vfd drawing
@user-nl4yc5vq3y
@user-nl4yc5vq3y Жыл бұрын
Assalamu alaikum Hamare pas ACS800 drive hay jes may group 99.1 se direct 99.9 pe chala jata hay motor data nahe araha parameter stat group 14 se ho jata please help Younas cherat cement
@bishantkumar12589
@bishantkumar12589 Жыл бұрын
namaste ... aapke drive me kisi ne parameters ko lock kar diya hoga... parameter number - 16.02 PARAMETER LOCK , check karo aap. agar 65535 hai too lock hai, 0 hona chahie.
@user-nl4yc5vq3y
@user-nl4yc5vq3y Жыл бұрын
@@bishantkumar12589 janab shukreya check kar ke aap se contact kar longa. Unlock ka koe pascode hay??
@bishantkumar12589
@bishantkumar12589 Жыл бұрын
@@user-nl4yc5vq3y ye too apke company ka incharge ya abb service engineer wala hi bata sakta hai kya set kiya hua tha
@bishantkumar12589
@bishantkumar12589 Жыл бұрын
agar aapko mere videos saahi lagte hai too please apne electrical dosto k sath v share kare is channel ko. thank you
@user-nl4yc5vq3y
@user-nl4yc5vq3y Жыл бұрын
@@bishantkumar12589 zaroor karonga
@NICE_LIFE1986
@NICE_LIFE1986 2 жыл бұрын
Sir, If I operate drive to MCC panel. Is put same parameters according yo this video pls confirm.
@bishantkumar12589
@bishantkumar12589 2 жыл бұрын
Yes. Parameter remain same mostly
@rishinathreghu579
@rishinathreghu579 2 жыл бұрын
hi sir, my abb acs 600 drive have i/o comm fault.what is the reason and how to troubleshoot and solve.
@omkarkumar5000
@omkarkumar5000 2 жыл бұрын
Sir abb ACS 1000 main water temperature reference setting kon se parameters group main milega please reply
@bishantkumar12589
@bishantkumar12589 2 жыл бұрын
Check kar k reply karta hu
@terus_belajar-
@terus_belajar- 2 жыл бұрын
I have Acs800, I have problem that acs800 have fault BR Wiring (7111), can you tell me how to fix it?
@bishantkumar12589
@bishantkumar12589 2 жыл бұрын
Sure sir. I'll check and let you know
@bishantkumar12589
@bishantkumar12589 2 жыл бұрын
BR WIRING (7111) 3.17 FW 5 bit 1 Wrong connection of brake resistor Check resistor connection. Ensure brake resistor is not damaged.
@durgeshkadu8181
@durgeshkadu8181 2 жыл бұрын
I want 440volt output voltage at 27HZ nominal frequency I have set I have set all parameters as per name plate data in para. 99 ... The voltage is still 415-420 volt output what should be done else for getting 440volt output at 27Hz freq output frequency.
@bishantkumar12589
@bishantkumar12589 2 жыл бұрын
I believe these drives are designed for 0-50hz frequency only with 0 Hz= 0 V and 50 Hz = 415V, But, you can change the minimum and maximum speed in the limit parameter, you will get the desired voltage at 27Hz. Try this, if u don't get, text me back
@durgeshkadu8181
@durgeshkadu8181 2 жыл бұрын
@@bishantkumar12589 I have checked in limit parameter 20 here min freq. I setted 0 hz and maximum 27hz then also output voltage is 415volt as I set 440volt nominal voltage in para 99...here I m not seems minimum and maximum RPM setting
@bishantkumar12589
@bishantkumar12589 2 жыл бұрын
@@durgeshkadu8181 what's the speed at 27Hz. ?
@durgeshkadu8181
@durgeshkadu8181 2 жыл бұрын
@@bishantkumar12589 currently I am testing without load and I seems voltage does not boosted to 440volt and I have tested 4pole motor with this parameter nominal voltage 440volt nominal frequency 27hz and motor design for 415v, 50hz due to motor gets overloaded at this stage even at no load .. It was trial at 4pole motor actually I want to test 440volt , 27hz , 12pole motor which is under production
@9368737888
@9368737888 2 жыл бұрын
How to reset complete parameter
@bishantkumar12589
@bishantkumar12589 2 жыл бұрын
Factory reset can be done 👍
@PintuVerma-cv9uk
@PintuVerma-cv9uk 3 жыл бұрын
सर ACS लिखा हैं मॉडल मे उसका मतलब या फूल फॉर्म क्या होता हैं
@bishantkumar12589
@bishantkumar12589 3 жыл бұрын
ACS bus family group ka naam hai.
@earntechsv5384
@earntechsv5384 2 жыл бұрын
Moter stop hone ke bad reverse aa rha hai ky falt ho skata
@bishantkumar12589
@bishantkumar12589 2 жыл бұрын
Motor reverse run ho raha h kya ?
@earntechsv5384
@earntechsv5384 2 жыл бұрын
Ha sir rukne ke bad thoda reverse ghum rha hai kis parameter ka problem ho skata hai sir please tell us
@bishantkumar12589
@bishantkumar12589 2 жыл бұрын
@@earntechsv5384 pump application hai kya ?
@earntechsv5384
@earntechsv5384 2 жыл бұрын
Nhi sir EOT CRANE ME ABB ACS 800 DRIVE LAGI HAI USKA USE FORWARD REVERSE MOTION HAI USI KI PROBLEM Hai
@bishantkumar12589
@bishantkumar12589 2 жыл бұрын
@@earntechsv5384 okay main check karta hu
@NICE_LIFE1986
@NICE_LIFE1986 2 жыл бұрын
Sir, I have Acs 800 drive how to speed control by Protections meter. Kindly share Basis parameters Acs 800 drive.
@bishantkumar12589
@bishantkumar12589 2 жыл бұрын
Ok sir. I'll in some time
@NICE_LIFE1986
@NICE_LIFE1986 2 жыл бұрын
@@bishantkumar12589 sir, Can your share mobile number? Pls
@vaibhavdave1016
@vaibhavdave1016 2 жыл бұрын
Sir hamare pass ACS 800 hai.. usme fiber optic thi mod bus ke sath hoke PLC ma communication jata hai.. Abhi fiber optic ka light thik hai fir fir bhi communication nhi mil raha or.. Eroor hi ata hai.. communication module 7510 vala
@vaibhavdave1016
@vaibhavdave1016 2 жыл бұрын
Parameters me bahut try kiya pr vo error nhi jaa raha
@bishantkumar12589
@bishantkumar12589 2 жыл бұрын
Check kar k bolta hu sr
@bishantkumar12589
@bishantkumar12589 2 жыл бұрын
ONCE CHANGE THE OPTICAL CABLE AND TRY TO OPERATE THE VFD
@aghashahzad460
@aghashahzad460 2 жыл бұрын
Bro kindly explain master slave parameter of acs800 kindly share
@bishantkumar12589
@bishantkumar12589 2 жыл бұрын
Ok sir. I'll surely try to work on it ASAP
@rashadmuhammad8554
@rashadmuhammad8554 2 жыл бұрын
How I can increase rpm hz settings while drive is running on profibus mode
@bishantkumar12589
@bishantkumar12589 2 жыл бұрын
Sorry, I don't have that information. Pl contact your service engineer
@sujitsutar4953
@sujitsutar4953 3 жыл бұрын
Danfoss drive ka video kijiye.
@bishantkumar12589
@bishantkumar12589 3 жыл бұрын
Okay sir 👍
@user-rj7hs6lm1e
@user-rj7hs6lm1e 27 күн бұрын
Hello sir 🙏 app k what's up number chahe sir Mai Nigeria Mai Job Kar hoo mera question tha Discussion Karn hai plz Sir. From odisha Jay Jagannath 🙏
@bishantkumar12589
@bishantkumar12589 27 күн бұрын
Hello bhai. Kya problem hua h. Batao. Kaun si company me ho waha ? Quantum group?
@Fire_palace
@Fire_palace Жыл бұрын
ABB ACS 800 vfd parameter UPLOAD & DOWNLOAD using Drive 🪟. Please make 🙏 a video please 🙏 Sir.
@bishantkumar12589
@bishantkumar12589 Жыл бұрын
Using HMI/CDP is available
@Fire_palace
@Fire_palace Жыл бұрын
Sir Drive window se kaise karte h uske procedure chahiye
@bishantkumar12589
@bishantkumar12589 Жыл бұрын
@@Fire_palace thode time me upload karta hu
@mdmasumbellah6487
@mdmasumbellah6487 2 жыл бұрын
Sir how to contact with you...plz
@bishantkumar12589
@bishantkumar12589 2 жыл бұрын
Pl ask ur doubt. Here
@shrikantha76
@shrikantha76 2 жыл бұрын
@@bishantkumar12589 in my case I am getting fault in LT drive as ACS800 Temperature fault when we operate above 2nd step speed where as Temperature is normal inside E room. Please suggest what is the remedy? Thank you..
@mdmasumbellah6487
@mdmasumbellah6487 2 жыл бұрын
@@bishantkumar12589 I want to send a problem video clip
ABB ACS 800 DRIVE - MOTOR ID RUN PROCEDURE : HINDI VIDEO
4:36
Bishant Kr: Electrical💡& More
Рет қаралды 27 М.
How to set basic parameter  in ABB Acs880  Drive complete settings..
17:16
Incredible Dog Rescues Kittens from Bus - Inspiring Story #shorts
00:18
Fabiosa Best Lifehacks
Рет қаралды 38 МЛН
escape in roblox in real life
00:13
Kan Andrey
Рет қаралды 38 МЛН
ABB ACS880 VFD - IMPORTANT PARAMETERS : HINDI VIDEO
20:00
Bishant Kr: Electrical💡& More
Рет қаралды 9 М.
Vfd complete parameter setting || ABB ACS560 Parameter Entry
16:39
Electrical with Tech.
Рет қаралды 5 М.
VFD Control Methods | Scalar Mode | Vector Mode
13:35
Instrumentation Unlimited
Рет қаралды 20 М.
19. ABB ACS 800 Drive Basic Startup & commissioning
29:18
Average Engineer
Рет қаралды 14 М.
ABB INVERTER DRIVE ACS800 BASICS
9:31
Electrotype
Рет қаралды 4,1 М.
ABB ACS580 VFD - IMPORTANT PARAMETERS & SETTINGS
21:47
Bishant Kr: Electrical💡& More
Рет қаралды 23 М.
ABB DCS 800 dc drive parameter setting in hindi | abb dc800 ka programing kaise karte hai
12:34
ABB ACS 880 DRIVE - MOTOR ID RUN / IDENTIFICATION RUN STEPS - HINDI ME
4:05
Bishant Kr: Electrical💡& More
Рет қаралды 35 М.
How to operate key pad function of display unit of ABB ACS 800
10:12
Mubashar Electronics Service